Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Ancillary services management policies in India: an overview and Key issues

For a restructuring Indian power sector, a preliminary structure of the market and power exchange has already been proposed by Central Electricity Regulatory Commission. The success of this market will be strongly tied to the proper provision of ancillary services, particularly frequency and voltage control. The authors describe the current status of ancillary services mechanisms and key issues that need to be addressed. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Active control of turbomachine discrete tones

This paper was directed at active control of discrete frequency noise generated by subsonic blade rows through cancellation of the blade row interaction generated propagating acoustic waves. First discrete frequency noise generated by a rotor and stator in a duct was analyzed to determine the propagating acoustic pressure waves. Then a mathematical model was developed to analyze and predict the active control of discrete frequency noise generated by subsonic blade rows through cancellation of the propagating acoustic waves, accomplished by utilizing oscillating airfoil surfaces to generate additional control propagating pressure waves. These control waves interact with the propagating acoustic waves, thereby, in principle, canceling the acoustic waves and thus, the far field discrete frequency tones. This model was then applied to a fan exit guide vane to investigate active airfoil surface techniques for control of the propagating acoustic waves, and thus the far field discrete frequency tones, generated by blade row interactions.

Fleeter, Sanford↗

Space and phase resolved ion energy and angular distributions in single- and dual-frequency capacitively coupled plasmas

The control of ion energy and angular distributions (IEADs) is critically important for anisotropic etching or deposition in microelectronic fabrication processes. With single frequency capacitively coupled plasmas (CCPs), the narrowing in angle and spread in energy of ions as they cross the sheath are definable functions of frequency, sheath width, and mean free path. With increases in wafer size, single frequency CCPs are finding difficulty in meeting the requirement of simultaneously controlling plasma densities, ion fluxes, and ion energies. Dual-frequency CCPs are being investigated to provide this flexible control. The high frequency (HF) is intended to control the plasma density and ion fluxes, while the ion energies are intended to be controlled by the low frequency (LF). However, recent research has shown that the LF can also influence the magnitude of ion fluxes and that IEADs are determined by both frequencies. Hence, separate control of fluxes and IEADs is complex. In this paper, results from a two-dimensional computational investigation of Ar/O{sub 2} plasma properties in an industrial reactor are discussed. The IEADs are tracked as a function of height above the substrate and phase within the rf cycles from the bulk plasma to the presheath and through the sheath with the goal of providing insights to this complexity. Comparison is made to laser-induced fluorescence experiments. The authors found that the ratios of HF/LF voltage and driving frequency are critical parameters in determining the shape of the IEADs, both during the transit of the ion through the sheath and when ions are incident onto the substrate. To the degree that contributions from the HF can modify plasma density, sheath potential, and sheath thickness, this may provide additional control for the IEADs.

36 MATERIALS SCIENCE↗

Ares I-X Flight Test Validation of Control Design Tools in the Frequency-Domain

A major motivation of the Ares I-X flight test program was to Design for Data, in order to maximize the usefulness of the data recorded in support of Ares I modeling and validation of design and analysis tools. The Design for Data effort was intended to enable good post-flight characterizations of the flight control system, the vehicle structural dynamics, and also the aerodynamic characteristics of the vehicle. To extract the necessary data from the system during flight, a set of small predetermined Programmed Test Inputs (PTIs) was injected directly into the TVC signal. These PTIs were designed to excite the necessary vehicle dynamics while exhibiting a minimal impact on loads. The method is similar to common approaches in aircraft flight test programs, but with unique launch vehicle challenges due to rapidly changing states, short duration of flight, a tight flight envelope, and an inability to repeat any test. This paper documents the validation effort of the stability analysis tools to the flight data which was performed by comparing the post-flight calculated frequency response of the vehicle to the frequency response calculated by the stability analysis tools used to design and analyze the preflight models during the control design effort. The comparison between flight day frequency response and stability tool analysis for flight of the simulated vehicle shows good agreement and provides a high level of confidence in the stability analysis tools for use in any future program. This is true for both a nominal model as well as for dispersed analysis, which shows that the flight day frequency response is enveloped by the vehicle s preflight uncertainty models.

Johnson, Matthew↗

Adaptive precompensators for flexible-link manipulator control

The application of input precompensators to flexible manipulators is considered. Frequency domain compensators color the input around the flexible mode locations, resulting in a bandstop or notch filter in cascade with the system. Time domain compensators apply a sequence of impulses at prespecified times related to the modal frequencies. The resulting control corresponds to a feedforward term that convolves in real-time the desired reference input with a sequence of impulses and produces a vibration-free output. An adaptive precompensator can be implemented by combining a frequency domain identification scheme which is used to estimate online the modal frequencies and subsequently update the bandstop interval or the spacing between the impulses. The combined adaptive input preshaping scheme provides the most rapid slew that results in a vibration-free output. Experimental results are presented to verify the results.

Tzes, Anthony P.↗

Executive Summary: Concentrating Solar Power Impact on Grid Reliability

This study examines the impact of concentrating solar power (CSP) on grid reliability by investigating the dynamic behavior of the Western Interconnection under conditions of high solar and wind generation. Reliability in this case refers to the somewhat narrow context of stability: transient stability and frequency response; and control stability, especially that associated with weak grids. The objectives of this study were to identify renewable energy penetration levels and mixes, severe disturbances, and load conditions where grid performance and reliability could be enhanced with CSP plants. Instantaneous penetrations of wind and solar - both photovoltaics (PV) and CSP - up to approximately 60% were considered. The focus is on situations in the Western Interconnection bulk power system during which variable renewable generation has displaced other (non-CSP) synchronous thermal generation under highly stressed, weak system conditions. Particular attention was given to impacts of frequency-responsive controls and synchronous generation characteristics.

14 SOLAR ENERGY↗

Concentrating Solar Power Impact on Grid Reliability

This study examines the impact of concentrating solar power (CSP) on grid reliability by investigating the dynamic behavior of the Western Interconnection under conditions of high solar and wind generation. Reliability in this case refers to the somewhat narrow context of stability: transient stability and frequency response; and control stability, especially that associated with weak grids. The objectives of this study were to identify renewable energy penetration levels and mixes, severe disturbances, and load conditions where grid performance and reliability could be enhanced with CSP plants. Instantaneous penetrations of wind and solar - both photovoltaics (PV) and CSP - up to approximately 60% were considered. The focus is on situations in the Western Interconnection bulk power system during which variable renewable generation has displaced other (non-CSP) synchronous thermal generation under highly stressed, weak system conditions. Particular attention was given to impacts of frequency-responsive controls and synchronous generation characteristics.

14 SOLAR ENERGY↗

Coordination and Control of Building HVAC Systems to Provide Frequency Regulation to the Electric Grid

Buildings consume 73% of electricity produced in the United States and, currently, they are largely passive participants in the electric grid. However, the flexibility in building loads can be exploited to provide ancillary services to enhance the grid reliability. In this paper, we investigate two control strategies that allow Heating, Ventilation and Air-Conditioning (HVAC) systems in commercial and residential buildings to provide frequency regulation services to the grid while maintaining occupants comfort. The first optimal control strategy is based on model predictive control acting on a variable air volume HVAC system (continuously variable HVAC load), which is available in large commercial buildings. The second strategy is rule-based control acting on an aggregate of on/off HVAC systems, which are available in residential buildings in addition to many small to medium size commercial buildings. Hardware constraints that include limiting the switching between the different states for on/off HVAC units to maintain their lifetimes are considered. Furthermore, simulations illustrate that the proposed control strategies provide frequency regulation to the grid, without affecting the indoor climate significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adapting the monitoring and control systems on the 300 MW power generation units at the Iriklinskaya GRES to modern operational requirements

Work done by JSC 'Interavtomatika' and the Iriklinskaya GRES (State Regional Electric Power Plant) to create automatic frequency and power control systems is reported. This involved reconstructing the turbine regulator systems and modernizing all the regulators for the power generator unit (those coupled to and those not coupled to the automatic frequency and power control systems) and the automatic burner control systems on the basis of a unified Simatic PCS7 PS controller system for the four 300 MW power generation units at the Iriklinskaya GRES.

13 HYDRO ENERGY↗

Controllable Single-Molecule Light Emission by Selective Charge Injection in Scanning Tunneling Microscopy

Tunneling electron-induced light emission in scanning tunneling microscopy (STM) has recently been explored as a novel light source with tunable properties. In this work, using first-principles-based atomistic simulations, we study the STM-induced luminescence of a single free-base phthalocyanine (H 2 Pc) molecule and present a way to control the emission frequency of the STM molecular junction by precisely controlling the charge injection at different molecular positions. The luminescence is found to be directly related to the spatial distribution of the molecular states and thus depends sensitively on the tip position. Through careful refinement of the chemical structures, devices with desirable frequencies at different parts of the emitting unit can be designed. Our report has profound implications for applications in nanoscale optoelectronics and future hybrid electronic-photonic circuits.

36 MATERIALS SCIENCE↗

Vortex control for rotor blade devices

To control vortices originating at the tips of a rotor's blades rotating through the air at a revolution frequency f, separation control device(s) are actuated to periodically introduce perturbations into the airflow moving over the blades. The periodic introduction of perturbations is controlled in accordance with a periodic modulating frequency of introduction f.sub.0 while the frequency of the perturbations so-introduced is designated as f.sub.e. Vortex control is achieved when the periodic modulating frequency of introduction f.sub.0 satisfies the relationship nf.ltoreq.f.sub.0.ltoreq.f.sub.e where n is the number of blades.

Greenblatt, David↗

Interaction of feel system and flight control system dynamics on lateral flying qualities

An investigation of feel system and flight control system dynamics on lateral flying qualities was conducted using the variable stability USAF NT-33 aircraft. Experimental variations in feel system natural frequency, force-deflection gradient, control system command architecture type, flight control system filter frequency, and control system delay were made. The experiment data include pilot ratings using the Cooper-Harper (1969) rating scale, pilot comments, and tracking performance statistic. Three test pilots served as evaluators. The data indicate that as the feel system natural frequency is reduced lateral flying qualities degrade. At the slowest feel system frequency, the closed-loop response becomes nonlinear with a 'bobweight' effect apparent in the feel system. Feel system influences were essentially independent of the control system architecture. The flying qualities influence due to the feel system was different than when the identical dynamic systenm was used as a flight control system element.

Bailey, Randall E.↗

Impacts of Inverter-Based Advanced Grid Support Functions on Islanding Detection

A long-standing requirement for inverters paired with distributed energy resources is that they are required to disconnect from the electrical power system (EPS) when an electrical island is formed. In recent years, advanced grid support controls have been developed for inverters to provide voltage and frequency support by integrating functions such as voltage and frequency ride-through, volt-VAr control, and frequency-Watt control. With these new capabilities integrated into the inverter, additional examination is needed to determine how voltage and frequency support will impact pre-existing inverter functions like island detection. This paper inspects how advanced inverter functions will impact its ability to detect the formation of an electrical island. Results are presented for the unintentional islanding laboratory tests of three common residential-scale photovoltaic inverters performing various combinations of grid support functions. For the inverters tested, grid support functions prolonged island disconnection times slightly; however, it was found that in all scenarios the inverters disconnected well within two seconds, the limit imposed by IEEE Std 1547-2003.

14 SOLAR ENERGY↗

Identifying Urban Pluvial Frequency Flooding Hotspots Using the Topographic Control Index and Remote Sensing Radar Images for Early Warning Systems

Identifying areas that frequently experience post-rainfall ponding is essential for effective flood mitigation and planning. This study integrates Sentinel-1 radar imagery and the Topographic Control Index (TCI) to identify 378 flood-prone urban depressions in Beaumont, Texas. Out of 159 major rainfall events, only six had Sentinel-1 radar imagery acquired within six hours of peak rainfall, and these were used to generate the flood frequency map; the ground-based flood sensor data were used to verify that these selected events corresponded to actual peak rainfall and to validate radar-detected water pixels. Validation results showed 100% precision, 70.87% recall, an F1-score of 82.95%, and 71.32% overall accuracy. Approximately 84% of medium-to-high TCI depressions overlapped with Beaumont’s two-year inundation map, confirming a strong relationship between TCI and observed flooding. A total of 124 depressions retained significant water, and after excluding 25 engineered detention ponds, 99 natural depressions remained flood vulnerable. Among these, 74 depressions with medium or high TCI were identified as the highest-priority nuisance flooding hotspots. The results demonstrate that combining TCI with radar imagery provides a reliable and cost-effective approach for identifying areas prone to frequent urban ponding. This framework supports practical decision-making for drainage improvements, hotspot identification, and early-warning system development in urban flood-prone regions.

Sentinel-1 radar imagery↗

A stochastic operational model for controlling electric vehicle charging to provide frequency regulation

The charging of battery electric vehicles (BEVs) is a potential source of flexibility and ancillary services to power systems. Herein this paper proposes a two-stage stochastic problem that can be used to optimize the charging of BEVs in a public charging station to provide frequency regulation and energy arbitrage. The model also co-optimizes the use of distributed energy resources, including battery energy storage and photovoltaic solar panels. We demonstrate the performance of the proposed model using a case study based on the Central-Ohio region. The case study shows that proper management of flexibility in BEV charging can provide high-quality frequency regulation services, which is also of significant financial value to the station operator. As such, the modeling methodology that we propose here can further accelerate the adoption of BEVs. This is because the value streams generated by the provision of frequency regulation can reduce the cost of BEV ownership and the net cost of owning and operating a public BEV-charging station.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High frequency drive mechanism for an active controls systems aircraft control surface

The mechanism was successfully utilized on a wind tunnel model tested in the transonic blow down tunnel. The mechanism is also applicable to a flying aircraft. Several interrelated mechanical subsystems were utilized, including a low inertia antibacklash drive mechanism for high frequency oscillation and a compact antibacklash drive mechanism for conversion of rotary motion to linear motion.

Smith, H. E.↗