Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Control Limits for Building Energy End Use Based on Engineering Judgment, Frequency Analysis, and Quantile Regression

Approaches are needed to continuously characterize the energy performance of commercial buildings to allow for (1) timely response to excess energy use by building operators; and (2) building occupants to develop energy awareness and to actively engage in reducing energy use. Energy information systems, often involving graphical dashboards, are gaining popularity in presenting energy performance metrics to occupants and operators in a (near) real-time fashion. Such an energy information system, called Building Agent, has been developed at NREL and incorporates a dashboard for public display. Each building is, by virtue of its purpose, location, and construction, unique. Thus, assessing building energy performance is possible only in a relative sense, as comparison of absolute energy use out of context is not meaningful. In some cases, performance can be judged relative to average performance of comparable buildings. However, in cases of high-performance building designs, such as NREL's Research Support Facility (RSF) discussed in this report, relative performance is meaningful only when compared to historical performance of the facility or to a theoretical maximum performance of the facility as estimated through detailed building energy modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Optimal Flexibility in Ensemble of Frequency Responsive Loads

Potential of electrical loads in providing grid ancillary services is often limited due to the uncertainties associated with the load behavior. A knowledge of the expected uncertainties with a load control program would invariably yield to better informed control policies, opening up the possibility of extracting the maximal load control potential without affecting grid operations. In the context of frequency responsive load control, a probabilistic uncertainty analysis framework is presented to quantify the expected error between the target and actual load response, under uncertainties in the load dynamics. A closed-form expression of an optimal demand flexibility, minimizing the expected error in actual and committed flexibility, is provided. Analytical results are validated through Monte Carlo simulations of ensembles of electric water heaters.

Kundu, Soumya↗

System Modeling and Simulation of In-Stream Hydrokinetic Turbines for Power Management and Control

Electricity generation from moving currents without using dams (i.e., in-stream hydrokinetic electricity) has the potential to introduce multiple GW of renewable power to U.S. grids. Here this study evaluates a control system designed to regulate the generator rotor rate (rpm) to improve power production from in-stream hydrokinetic turbines. The control algorithm is evaluated using numerical models of both a rigidly mounted tidal turbine (TT) and a moored ocean current turbine (OCT) coupled to an induction electric machine model. The moored simulation utilizes an innovative approach for coupling a multiple degrees-of-freedom (DOF) nonlinear hydrodynamic/mechanical turbine model with a nonlinear electromechanical generator model. Based on the turbine torque-speed characteristic, as well as the asynchronous machine features, a proportional–integral (PI) controller is used to generate a correction term for the frequency of the three-phase sinusoidal voltages that are supplied to the asynchronous generator. The speed control of the induction generator through the supply frequency is accomplished by a simplified voltage source inverter (VSI). The simplified VSI consists of control voltage sources (CVSs), while the comparison with a real VSI using diodes and transistors, which are controlled by pulse width modulation (PWM) technique, is also presented. Simulations are used to evaluate the developed algorithms showing that rpm fluctuations are around 0.02 for a tidal turbine operating in a wave field with a 6 m significant wave height and around 0.005 for a moored ocean current turbine operating in a wave field with a 2 m significant wave height.

16 TIDAL AND WAVE POWER↗

Improving Primary Frequency Response in Networked Microgrid Operations using Multilayer Perceptron-Driven Reinforcement Learning

Individual microgrids can improve the reliability of power grids during extreme events, and networked microgrids can further improve efficiency through resource sharing and increase the resilience of critical end-use loads. However, networked microgrid operations are subject to large switching transients, which can cause dynamic instability and lead to system collapse. These transients are especially prevalent in microgrids with high penetrations of inverter-connected renewable energy resources, which do not provide the system inertia needed to mitigate the transients. Existing generator controls can be modified to invoke a drop in terminal voltage in response to a frequency deviation, thereby reducing load and improving frequency response. This paper investigates the use of a reinforcement-learning--based controller trained over several switching transient scenarios to modify generator controls during large frequency deviations. Compared to previously used proportional integral controllers, the proposed controller can improve primary frequency response while adapting to changes in system topologies and events.

Radhakrishnan, Nikitha↗

Frequency-independent approach to calculate physical optics radiations with the quadratic concave phase variations

In this work, we develop the numerical steepest descent path (NSDP) method to calculate the physical optics (PO) radiations with the quadratic concave phase variations. With the surface integral equation method, the physical optics (PO) scattered fields are formulated and further reduced to the surface integrals. The high frequency physical critical points contributions, including the stationary phase points, the boundary resonance points and the vertex points are comprehensively studied via the proposed NSDP method. The key contributions of this work are twofold. One is that together with the PO integrals taking the quadratic parabolic and hyperbolic phase terms, this work makes the NSDP theory be complete for treating the PO integrals with quadratic phase variations. Another is that, in order to illustrate the transition effect of the high frequency physical critical points, in this work, we consider and further extend the NSDP method to calculate the PO integrals with the coalescence of the high frequency critical points. Numerical results for the highly oscillatory PO integral with the coalescence of the critical points are given to verify the efficiency of the proposed NSDP method. The NSDP method could achieve the frequency independent computational workload and error controllable accuracy in all the numerical experiments, especially for the case of the coalescence of the high frequency critical points.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simple-design ultra-low phase noise microwave frequency synthesizers for high-performing Cs and Rb vapor-cell atomic clocks

We report on the development and characterization of novel 4.596 GHz and 6.834 GHz microwave frequency synthesizers devoted to be used as local oscillators in high-performance Cs and Rb vapor-cell atomic clocks. The key element of the synthesizers is a custom module that integrates a high spectral purity 100 MHz oven controlled quartz crystal oscillator frequency-multiplied to 1.6 GHz with minor excess noise. Frequency multiplication, division, and mixing stages are then implemented to generate the exact output atomic resonance frequencies. Absolute phase noise performances of the output 4.596 GHz signal are measured to be −109 and −141 dB rad{sup 2}/Hz at 100 Hz and 10 kHz Fourier frequencies, respectively. The phase noise of the 6.834 GHz signal is −105 and −138 dB rad{sup 2}/Hz at 100 Hz and 10 kHz offset frequencies, respectively. The performances of the synthesis chains contribute to the atomic clock short term fractional frequency stability at a level of 3.1 × 10{sup −14} for the Cs cell clock and 2 × 10{sup −14} for the Rb clock at 1 s averaging time. This value is comparable with the clock shot noise limit. We describe the residual phase noise measurements of key components and stages to identify the main limitations of the synthesis chains. The residual frequency stability of synthesis chains is measured to be at the 10{sup −15} level for 1 s integration time. Relevant advantages of the synthesis design, using only commercially available components, are to combine excellent phase noise performances, simple-architecture, low-cost, and to be easily customized for signal output generation at 4.596 GHz or 6.834 GHz for applications to Cs or Rb vapor-cell frequency standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed Secondary Control of Grid-Forming Inverters and AC Microgrids: Impacts of Voltage Feedback Choices

In this paper, the operational choices in distributed secondary control are examined, and their impacts on grid-forming (GFM) inverters and grid operation are investigated. In particular, the effects of feedback voltage choices, either average voltage feedback (AVF) or terminal voltage feedback (TVF), are studied with respect to reactive power sharing, voltage regulation, and grid-forming operation during black start. The secondary control used is a subgradient-based distributed cooperative control, and it provides the voltage, angle, and frequency references to the GFM inverters and their primary tracking controls. The overall control architecture employs multi-rate sampling such that the secondary control is slower than the primary control. The operational choices and their control performance are illustrated using a four-GFM-inverter microgrid in MATLAB/SIMULINK. Furthermore, the results show the effectiveness of the secondary controller, and several conclusions are drawn on the voltage feedback signals as the design choices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of dynamic testing of full-scale wind turbine drivetrains with hardware-in-the-loop

Dynamometer testing of full-scale wind turbine drivetrains involves subjecting integrated components to extreme static loads, fatigue loads, or dynamic loads to replicate field conditions. This paper provides a detailed evaluation of the uncertainty and errors in applied loads and measured responses, and their magnitude relative to established repeatability bounds for a drivetrain subjected to static and dynamic loads on the 7.5 MW test bench at the Clemson University Wind Turbine Drivetrain Testing Facility. An ideal drivetrain simulation model is utilized to isolate the influence of load tracking errors on test article responses. It is shown that the test article response variations are mainly driven by run out and clearances inherent to the drivetrain. For the dynamic profiles, the load tracking errors are within acceptable limits. Furthermore, a frequency analysis is used to show that the test bench controller tracking performance is acceptable for profiles with frequency content up to 1.5 Hz.

17 WIND ENERGY↗

Open-Loop Control of Adjustable Tuned Mass Dampers for Floating Wind Turbine Platforms

In this study, we demonstrate the ability of adjustable tuned mass dampers (TMDs) to reduce the platform motion of floating offshore wind turbines (FOWTs). The TMDs are located in the hull and provide control authority by varying the amount of water ballast and compressed air in a reservoir over time. The optimal TMD settings depend on the wind and wave conditions of the FOWT. We present an open-loop control scheme that changes the TMD natural frequency based on sea state and a simple method for estimating the peak wave period and significant wave height. The performance of this open-loop control is compared to ideal control of the TMDs (set knowing the exact sea state), a TMD with a constant natural frequency targeting the design load case with the greatest platform motion, and a baseline set of simulations of the platform without TMDs. The constant natural frequency case performs nearly as effectively as the actively controlled case, suggesting that the TMDs can be simply designed for extreme load conditions and provide consistent control over a range of environments; however, the methods used to find the optimal TMD parameters and estimate sea state statistics could be used in other aspects of FOWT control and design.

artificial intelligence↗

Optimal Modulation and DM Filter Design for a High Switching Frequency Single-Stage Microinverter

This paper presents an optimal modulation and systematic filter design approach for a single-stage dual-active-bridge (DAB) based dc-ac microinverter to achieve improved differential-mode (DM) noise performance for electromagnetic interference (EMI) tests. As DM filters contribute significantly to the overall converter volume, the main objective of this work is to leverage the degrees of freedom in the DAB converters to effectively attenuate the EMI noise. In addition, the DM filter design method needs to ensure near unity power factor converter operation. To achieve these targets, this paper analyzes three modulation strategies based on fixed or variable switching frequency operation where the different control modulation variables are varied to find the simulated DM noise spectrum. Based on the required DM attenuation, a constrained optimization problem is formulated to determine minimal DM filter parameters. Simulation results show that a spread spectrum approach with variable switching frequency is shown to minimize the DM EMI attenuation effort by spreading the noise profile. A fully GaN 400 W hardware prototype demonstrated the spread-sprectrum approach.

14 SOLAR ENERGY↗

Tailored Frequency Conversion in Nonlinear Subwavelength Grating Metaslabs

The use of metaslab waveguides consisting of subwavelength gratings (SWGs) is proposed as a highly flexible approach to obtain phase‐matched frequency conversion in nonlinear integrated devices. Control over the phase matching (PM) condition is achieved through modification of the linear modal propagation constants by the SWG. The method is experimentally demonstrated by fabrication of 0.4 mm‐long GaAs metaslabs designed for second harmonic generation of near‐infrared light. A controlled spectral shift of up to 100 nm in the PM condition, relative to a uniform slab is observed. Excellent agreement is found between the experimental results and finite‐difference eigenmode simulations, which predict a tunable frequency conversion bandwidth of ∼300 nm for the design parameters. The different regimes of PM control supported by the structure are discussed. This work highlights the potential of SWGs as building blocks for tailored frequency conversion in nonlinear integrated devices.

Form birefringence↗

Open-Loop Control of Adjustable Tuned Mass Dampers for Floating Wind Turbine Platforms: Preprint

Floating offshore wind turbines have several advantages over their land-based counterparts, including access to stronger, more consistent winds and proximity to population centers. However, increased costs from the platform have been a challenge inhibiting their widespread adoption. New damping technologies with tunable target frequencies and damping ratios promise a greater degree of control over platform motions, allowing hulls to be designed smaller and reducing the overall cost of the turbines. In this work, a control strategy is proposed for these adjustable tuned mass dampers (TMDs). A frequency-domain model of the system is developed, from which response amplitude operators (RAOs) for the platform's rigid-body modes can be obtained for different natural frequencies and damping ratios of the dampers. Using these RAOs, and JONSWAP spectrums of operational and extreme sea states, the performance of the various damper settings are compared by evaluating the standard deviation of a rigid-body motion of interest (platform pitch or heave). By finding the optimal damper setting for a range of representative design load cases (DLCs), a lookup function is made to return the damper target frequency given the peak period of the sea state. To determine the current sea state, we propose a simple estimator that uses wave measurements (e.g., from a measurement buoy) to determine the peak period and significant wave height. The significant wave height is determined using the statistics of the past 100 seconds of wave elevation information and the peak period is computed using a frequency locked loop. Initial results show that we can use these estimated values to control the TMD natural frequency with an open loop controller. The controlled system is tested in a range of environmental conditions determined by the International Electrotechnical Commission design load cases (DLCs), which include normal and extreme wind and wave models. In these tests, we compare the performance of 4 cases: (1) no TMD, (2) a constant TMD based on the worst case DLC, (3) a controlled TMD based on known wind and wave environments, and (4) a real-time controlled TMD using estimated wind and wave environments. The effect of hull-based TMD control is also compared to changes in traditional wind turbine control via blade pitch.

control↗

Laser frequency stabilization by dual arm locking for LISA

The Laser Interferometer Space Antenna (LISA) will be the first dedicated space based gravitational wave detector. LISA will consist of a triangular formation of spacecraft, forming an interferometer with 5x10{sup 6} km long arms. Annual length variations of the interferometer arms prevent exact laser frequency noise cancellation. Despite prestabilization to an optical cavity the expected frequency noise is many orders of magnitude larger than the required levels. Arm locking is a feedback control method that will further stabilize the laser frequency by referencing it to the 5x10{sup 6} km arms. Although the original arm locking scheme produced a substantial noise reduction, the technique suffered from slowly decaying start-up transients and excess noise at harmonic frequencies of the inverse round-trip time. Dual arm locking, presented here, improves on the original scheme by combining information from two interferometer arms for feedback control. Compared to conventional arm locking, dual arm locking exhibits significantly reduced start-up transients, no noise amplification at frequencies within the LISA signal band, and more than 50 fold improvement in noise suppression at low frequencies. In this article we present a detailed analysis of the dual arm locking control system and present simulation results showing a noise reduction of 10 000 at a frequency of 10 mHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of DER Communication Delay in AGC: Cyber-Physical Dynamic Co-Simulation: Preprint

Distributed energy resource (DER) frequency regulations are promising technologies for future grid operation. Unlike conventional generators, DERs might require open communication networks to exchange signals with control centers, possibly through DER aggregators; therefore, the impacts of the communication variations including the latency on the system frequency stability need to be investigated. This paper develops a cyber-physical dynamic simulation (CPDS) model based on the Hierarchical Engine for Large-Scale Co-Simulation (HELICS) to evaluate the impact of the communication variations, such as delays in DER frequency regulations. The feasible delay range can be obtained under different AGC parameter settings. The results show that the risk of instability generally increases with the communication delay and that the difference of AGC provided from DER and conventional generation units should be recognized when designing frequency regulation controllers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Phase-Locked Loop Noise Reduction via Phase Detector Implementation for Single-Phase Systems

A crucial component of grid-connected converters is the phase-locked loop (PLL) control subsystem that tracks the grid voltage's frequency and phase angle. Therefore, accurate fast-responding PLLs for control and protection purposes are required to provide these measurements. This paper proposes a novel feedback mechanism for single-phase PLL phase detectors using the estimated phase angle. Ripple noise appearing in the estimated frequency, most commonly the second harmonic under phase-lock conditions, is reduced or eliminated without the use of low-pass filters, which can cause delays to occur and limits the overall performance of the PLL response to dynamic changes in the system. The proposed method has the capability to eliminate the noise ripple entirely and, under extreme line distortion conditions, can reduce the ripple by at least half. Other modifications implemented through frequency feedback are shown to decrease the settling time of the PLL up to 50%. Mathematical analyses with the simulated and experimental results are provided to confirm the validity of the proposed methods.

42 ENGINEERING↗

Constant Frequency ZVS PWM Converter

In this paper, a simple yet novel buck or boost adaptive zero-voltage switching (ZVS) converter topology is proposed for soft switching pulse-width modulation (PWM) dc / dc converters. The converter is designed for the high switching frequency that can achieve high efficiency by reducing switching losses for the entire load range at low and high power. Besides, the output at the load terminals is maintained by a PWM signal at a fixed switching frequency, a phase shift signal between converter ports (legs) controls the system circulating current in order to provide the ZVS condition in all load conditions. With the proposed controller, the converter, thus, is suitable for high switching frequency and high-power applications with the small volume. The proposed dc / dc converter operation is analyzed, designed, and confirmed by simulation results for 240 V input, 400 V / 5 A output, and 200 kHz operating frequency at full load.

Asa, Erdem↗

Enabling DER Participation in Frequency Regulation Markets

Distributed energy resources (DERs) are playing an increasing role in ancillary services for the bulk grid, particularly in frequency regulation. In this article, we propose a framework for collections of DERs, combined to form microgrids and controlled by aggregators, to participate in frequency regulation markets. Our approach covers both the identification of bids for the market clearing stage and the mechanisms for the real-time allocation of the regulation signal. The proposed framework is hierarchical, consisting of a top layer and a bottom layer. The top layer consists of the aggregators communicating in a distributed fashion to optimally disaggregate the regulation signal requested by the system operator. The bottom layer consists of the DERs inside each microgrid whose power levels are adjusted so that the tie line power matches the output of the corresponding aggregator in the top layer. The coordination at the top layer requires the knowledge of cost functions, ramp rates, and capacity bounds of the aggregators. We develop meaningful abstractions for these quantities respecting the power flow constraints and taking into account the load uncertainties and propose a provably correct distributed algorithm for optimal disaggregation of regulation signals among the microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗