Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Application of laser photofragmentation-resonance enhanced multiphoton ionization to ion mobility spectrometry

We demonstrate detection of nitro-containing compounds with laser photofragmentation (PF) coupled with resonance enhanced multiphoton ionization (REMPI) and ion mobility spectrometry (IMS). In PF-REMPI, a laser dissociates the parent molecules, producing fragments that can then be ionized by absorption of additional laser photons. The production of these ions strongly depends on the wavelength of laser light, with ion yields corresponding to the absorption spectrum of the fragments [nitric oxide (NO) in the present case]. Combining IMS with PF-REMPI provides further specificity, separating ions according to their mobilities through an atmospheric-pressure drift tube. In this work, we use a pulsed UV laser to examine the characteristics of atmospheric-pressure PF-REMPI, the chemistry occurring in the ionization region and drift tube, and the viability of detecting ions created by both resonance-enhanced and nonresonant ionization. Probing NO in a helium-nitrogen bath, we demonstrate that the detection of ions displays single-shot response to changes in ion generation, with an ion extraction-to-collection efficiency of {approx}12%. We then evaluate the sensitivity and specificity of PF-REMPI/IMS as applied to the detection of both the explosive surrogate 2, 4-dinitrotoluene and the nuisance compound nitrobenzene.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of the K-shell ionization cross sections of Si by 3-25-keV electron impact using the thick-target method

In this paper, the K-shell ionization cross sections of Si element in the threshold energy region of 3-25 keV have been measured by using the thick-target method. With the Monte Carlo simulations, the effects of multiple scattering of incident electrons and from the bremsstrahlung photons and other secondary particles in the thick-target method have been discussed. The detection efficiency calibration in the lower-energy region has been performed by using the bremsstrahlung spectra of thick carbon target by electron impact in combination with the use of standard x-ray sources, and the detector thickness parameters have also been determined by a nonlinear least-squares fit. The ill-posed inverse problem involved in the thick-target method has been dealt with by the Tikhonov regularization method. The experimental K-shell ionization cross sections for Si element obtained in this paper have also been compared with some theoretical models, and it has been observed that the experimental data in this paper are in good agreement with the theoretical values based on the distorted-wave Born approximation model developed most recently.

74 ATOMIC AND MOLECULAR PHYSICS↗

Probing the active massive black hole candidate in the center of NGC 404 with VLBI

Recently, Nyland et al. argued that the radio emission observed in the center of the dwarf galaxy NGC 404 originates in a low-luminosity active galactic nucleus powered by a massive black hole (MBH, M ≲ 10{sup 6} M{sub ☉}). High-resolution radio detections of MBHs are rare. Here we present sensitive, contemporaneous Chandra X-ray, and very long baseline interferometry (VLBI) radio observations with the European VLBI Network. The source is detected in the X-rays, and shows no long-term variability. If the hard X-ray source is powered by accretion, the apparent low accretion efficiency would be consistent with a black hole (BH) in the hard state. Hard state BHs are known to show radio emission compact on the milliarcsecond scales. However, the central region of NGC 404 is resolved out on 10 mas (0.15-1.5 pc) scales. Our VLBI non-detection of a compact, partially self-absorbed radio core in NGC 404 implies that either the BH mass is smaller than 3{sub −2}{sup +5}×10{sup 5} M{sub ☉}, or the source does not follow the fundamental plane of BH activity relation. An alternative explanation is that the central BH is not in the hard state. The radio emission observed on arcsecond (tens of parsecs) scales may originate in nuclear star formation or extended emission due to AGN activity, although the latter would not be typical considering the structural properties of low-ionization nuclear emission-line region galaxies with confirmed nuclear activity.

79 ASTRONOMY AND ASTROPHYSICS↗

Ionization of atomic hydrogen in strong infrared laser fields

We have used the matrix iteration method of Nurhuda and Faisal [Phys. Rev. A 60, 3125 (1999)] to treat ionization of atomic hydrogen by a strong laser pulse. After testing our predictions against a variety of previous calculations, we present ejected-electron spectra as well as angular distributions for few-cycle infrared laser pulses with peak intensities of up to 10{sup 15} W/cm{sup 2}. It is shown that the convergence of the results with the number of partial waves is a serious issue, which can be managed in a satisfactory way by using the velocity form of the electric dipole operator in connection with an efficient time-propagation scheme.

74 ATOMIC AND MOLECULAR PHYSICS↗

Long-lived states of antiprotonic lithium pLi {sup +} produced in p+ Li collisions

Antiproton capture by lithium atoms (p+Li{yields}pLi{sup +}+e) is investigated at collision energies from 0.01 to 10 eV by using a semiclassical (also know as quantum-classical hybrid) method, in which the radial distance between the antiproton and the Li{sup +} ion is treated as a classical variable, and the other degrees of freedom are described by quantum mechanics. Analyzing the wave packet of the emitted electrons and making use of the energy conservation rule enable us to calculate the state distribution of the produced antiprotonic lithium pLi{sup +} atoms and also to distinguish between the capture and ionization ({yields}p+Li{sup +}+e) channels at collisional energies above the ionization threshold. This method is tested for the capture of negative muons by hydrogen atoms, which was rigorously investigated in previous quantum mechanical studies. Most of the pLi{sup +} atoms produced in p+Li are found to be sufficiently stable against Auger decays and are experimentally observable as long-lived states. The present system bears close similarities to the system of p+He(2S). It is therefore expected that long-lived antiprotonic helium pHe{sup +} atoms can be efficiently produced in the p capture by metastable He(2 {sup 3}S) atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Attosecond ionization gating for isolated attosecond electron wave packet and broadband attosecond xuv pulses

An attosecond ionization gating is achieved using a few-cycle laser pulse in combination with its second harmonic. With this gating, the generation of the electron wave packet (EWP) is coherently controlled, and an isolated EWP of about 270 as is generated. An isolated broadband attosecond extreme ultraviolet pulse with a bandwidth of about 75 eV can also be generated using this gating, which can be used for EWP measurements as efficiently as a 50-as pulse, allowing one to measure a wide range of ultrafast dynamics not normally accessible before.

74 ATOMIC AND MOLECULAR PHYSICS↗

Implementation of IMRT and VMAT using Delta4 phantom and portal dosimetry as dosimetry verification tools

In this study we analyzed and compared the dose distribution of different IMRT and VMAT plans with the intent to provide pre-treatment quality assurance using two different tools. Materials/Methods: We have used the electronic portal imaging device EPID after calibration to dose and correction for the background offset signal and also the Delta4 phantom after en evaluation of angular sensitivity. The Delta4 phantom has a two-dimensional array with ionization chambers. We analyzed three plans for each anatomical site calculated by Eclipse treatment planning system. The measurements were analyzed using γ-evaluation method with passing criteria 3% absolute dose and 3 mm distance to agreement (DTA). For all the plans the range of score has been from 97% to 99% for gantry fixed at 0° while for rotational planes there was a slightly decreased pass rates and above 95%. Point measurement with a ionization chamber were done in additional to see the accuracy of portal dosimetry and to evaluate the Delta4 device to various dose rates. Conclusions: Both Delt4 and Portal dosimetry shows good results between the measured and calculated doses. While Delta4 is more accurate in measurements EPID is more time efficient. We have decided to use both methods in the first steps of IMRT and VMAT implementation and later on to decide which of the tools to use depending on the complexity of plans, how much accurate we want to be and the time we have on the machine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model for the electrical conductivity in dense plasma mixtures

A new density functional theory, average atom based model for the electrical conductivity of dense plasmas with a mixture of ion species, containing no adjustable parameters, is presented herein. The model takes the temperature, mass density and relative abundances of the species as input. It takes into account partial ionization, ionic structure, and core-valence orthogonality, and uses quantum mechanical calculations of cross sections. Comparison to an existing high fidelity but computationally expensive method reveals good agreement. The new model is computationally efficient and can reach high temperatures. A new mixing rule is also presented that gives reasonably accurate conductivities for high temperature plasma mixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comprehensive computer model for magnetron sputtering. I. Gas heating and rarefaction

The complex interaction between several variables in magnetron sputtering discharges is a challenge in developing engineering design tools for industrial applications. For instance, at high pressures, rarefaction and gas heating should no longer be neglected for determining several parameters of the process. In this article, we use a comprehensive 3D reactor-scale simulator that incorporates most phenomena of interest in a self-consistent manner to simulate the transport of sputtered particles over a wide range of pressures and powers. Calculations of aluminum deposition rates and metal vapor densities are in reasonable agreement with experiments over a wide range of pressures and powers. Of the elements investigated (Al, Ti, and Cu), copper showed the greatest rarefaction (30%) due to its higher sputtering yield. Titanium, despite a slightly lower sputtering yield than Al, shows a greater rarefaction than aluminum as more particles are reflected from the target as high energy neutrals. In this case, a more efficient energy transfer process is responsible for the higher rarefaction observed in Ti sputtering when compared to Al. The authors also observed that by sputtering at a higher pressure, the probability of electron impact ionization of sputtered particles is increased and speculate about the role of this process in contrast to penning ionization, which is believed to be the dominant ionization mechanism in magnetron sputtering.

36 MATERIALS SCIENCE↗

Formation of imploding plasma liners for fundamental HEDP studies and MIF Standoff Driver Concept

The disciplines of High Energy Density Physics (HEDP) and Inertial Confinement Fusion (ICF) are characterized by hypervelocity implosions and strong shocks. The Plasma Liner Experiment (PLX) is focused on reaching HEDP and/or ICF relevant regimes in excess of 1 Mbar peak pressure by the merging and implosion of discrete plasma jets, as a potentially efficient path towards these extreme conditions in a laboratory. In this work we have presented the first 3D simulations of plasma liner, formation, and implosion by the merging of discrete plasma jets in which ionization, thermal conduction, and radiation are all included in the physics model. The study was conducted by utilizing a smoothed particle hydrodynamics code (SPHC) and was a part of the plasma liner experiment (PLX). The salient physics processes of liner formation and implosion are studied, namely vacuum propagation of plasma jets, merging of the jets (liner forming), implosion (liner collapsing), stagnation (peak pressure), and expansion (rarefaction wave disassembling the target). Radiative transport was found to significantly reduce the temperature of the liner during implosion, thus reducing the thermal leaving more pronounced gradients in the plasma liner during the implosion compared with ideal hydrodynamic simulations. These pronounced gradients lead to a greater sensitivity of initial jet geometry and symmetry on peak pressures obtained. Accounting for ionization and transport, many cases gave higher peak pressures than the ideal hydrodynamic simulations. Scaling laws were developed accordingly, creating a non-dimensional parameter space in which performance of an imploding plasma jet liner can be estimated. It is shown that HEDP regimes could be reached with ~ 5 MJ of liner energy, which would translate to roughly 10 to 20 MJ of stored (capacitor) energy. This is a potentially significant improvement over the currently available means via ICF of achieving HEDP and nuclear fusion relevant parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical Drivers of Emission-line Diversity of SDSS Seyfert 2s and LINERs after Removal of Contributions from Star Formation

Ionization sources other than H ιι regions give rise to the right-hand branch in the standard ([N ιι]) BPT diagram, populated by Seyfert 2s and LINERs. However, because the majority of Seyfert/LINER hosts are star-forming (SF), H ιι regions contaminate the observed lines to some extent, making it unclear if the position along the branch is merely due to various degrees of mixing between pure Seyferts/LINERs and SF, or whether it reflects the intrinsic diversity of Seyfert/LINER ionizing sources. In this study, we empirically remove SF contributions in ~100,000 Seyferts/LINERs from SDSS using the doppelganger method. Here, we find that mixing is not the principal cause of the extended morphology of the observed branch. Rather, Seyferts/LINERs intrinsically have a wide range of line ratios. Variations in ionization parameter and metallicity can account for much of the diversity of Seyfert/LINER line ratios, but the hardness of the ionization field also varies significantly. Furthermore, our k -means classification on seven decontaminated emission lines reveals that LINERs are made up of two populations, which we call soft and hard LINERs. The Seyfert 2s differ from both types of LINERs primarily by higher ionization parameter, whereas the two LINER types mainly differ from each other (and from star-forming regions) in the hardness of the radiation field. We confirm that the [N ιι] BPT diagram more efficiently identifies LINERs than [S ιι] and [O ι] diagnostics, because in the latter many LINERs, especially soft ones, occupy the same location as pure starformers, even after the SF has been removed from LINER emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Charge Separation for Muon Collider Cooling

Most schemes for six dimensional muon ionization cooling work for only one sign. It is then necessary to have charge separation prior to that cooling. Schemes of charge separation using bent solenoids are described, and their simulated performances reported. It is found that for efficient separation, it should take place at somewhat higher momenta than commonly used for the cooling. Charge separation using bent solenoids can be effective if carefully designed. Bent solenoids can generate dispersion from 'momentum drift', but can spoil emittance from 'amplitude drift'. Abrupt entry into a bent solenoid causes emittance growth, but matching using integral {lambda} lengths, or Norem's method, corrects this problem. Reverse bending removes the dispersion and reduces 'amplitude drift', but only if there is no rf until after all bending. The main problem is bunch lengthening and distortion from the long transports without rf. At 230 MeV/c, even with a higher field of 3 T, non-linearities increase the 6D emittance by 117% and give 13% loss, which is not acceptable. Raising the momentum from 230 to 300 MeV gives a 6D emittance growth of 38% and the loss 5%, which may be acceptable. Raising the momentum further to 400 MeV/c gives very good results: 6D growth of 24% and 2.5% loss. Further optimization should include the acceleration to the higher momenta prior to the separation, and the higher momentum cooling immediately after it. The longitudinal phase space prior to the separation should be rotated to minimize the total bunch lengthening.

43 PARTICLE ACCELERATORS↗

Phonon emission in germanium and silicon by electrons and holes in applied electric field at low temperature

The cryogenic dark matter search employs Ge and Si detectors to search for weakly interacting massive particle dark matter via its elastic-scattering interactions with nuclei while discriminating against interactions of background particles. These detectors distinguish nuclear recoils from electron recoils by simultaneously measuring phonon and ionization production in semiconducting substrates at sub-kelvin temperatures. They also reconstruct event position by quadrant-segmented measurement of the phonon signal. The ionization drift field does work on the electrons and holes. The charge carriers radiate this energy as acoustic phonons. At the typical applied field of 300 V/m in Ge (400 V/m in Si), we self-consistently model the behavior of the electrons and holes using independent drifted Maxwellian distributions, each characterized by an average drift velocity and an effective temperature, and including acoustic phonon emission. We calculate the phonon power angular and frequency distributions. We find that the bias polarity affects these distributions and, therefore, the phonon collection efficiency in Ge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Studies of Ion Beam Neutralization: Preliminary Results

A testing platform is designed to study ion beam neutralization in the mesothermal, collisionless region. In the experimental setup, argon neutrals were ionized in a microwave cavity and accelerated by a plasma lens system which was biased to 2500 V above the system ground. Electrons were boiled off from two hot tungsten filaments to neutralize the ion beam. The plasma is diagnosed using Langmuir probe and Faraday probe. A 3-D traversing system and a complete data acquisition loop were developed to efficiently measure 3-D beam profile. Preliminary measurements of beam profiles are presented for different operating conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved dosimetry using a pinpoint ionization chamber as quality assurance for IMRT and VMAT

Purpose: To develop a method to verify the dose delivery in relation to the individual control points of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using an ionization chamber. In addition to more effective problem solving during patient-specific quality assurance (QA), the aim is to eventually map out the limitations in the treatment chain and enable a targeted improvement of the treatment technique in an efficient way. Methods: Pretreatment verification was carried out for 255 treatment plans that included a broad range of treatment indications in two departments using the equipment of different vendors. In-house developed software was used to enable calculation of the dose delivery for the individual beamlets in the treatment planning system (TPS), for data acquisition, and for analysis of the data. The observed deviations were related to various delivery and measurement parameters such as gantry angle, field size, and the position of the detector with respect to the field edge to distinguish between error sources. Results: The average deviation of the integral fraction dose during pretreatment verification of the planning target volume dose was −2.1% ± 2.2% (1 SD), −1.7% ± 1.7% (1 SD), and 0.0% ± 1.3% (1 SD) for IMRT at the Radboud University Medical Center (RUMC), VMAT (RUMC), and VMAT at the Wellington Blood and Cancer Centre, respectively. Verification of the dose to organs at risk gave very similar results but was generally subject to a larger measurement uncertainty due to the position of the detector at a high dose gradient. The observed deviations could be related to limitations of the TPS beam models, attenuation of the treatment couch, as well as measurement errors. The apparent systematic error of about −2% in the average deviation of the integral fraction dose in the RUMC results could be explained by the limitations of the TPS beam model in the calculation of the beam penumbra. Conclusions: This study showed that time-resolved dosimetry using an ionization chamber is feasible and can be largely automated which limits the required additional time compared to integrated dose measurements. It provides a unique QA method which enables identification and quantification of the contribution of various error sources during IMRT and VMAT delivery.

60 APPLIED LIFE SCIENCES↗

Unifying the Micro and Macro Properties of AGN Feeding and Feedback

We unify the feeding and feedback of supermassive black holes with the global properties of galaxies, groups, and clusters by linking for the first time the physical mechanical efficiency at the horizon and megaparsec scale. The macro hot halo is tightly constrained by the absence of overheating and overcooling as probed by X-ray data and hydrodynamic simulations (ε{sub BH}≃10{sup −3} T{sub x,7.4}). The micro flow is shaped by general-relativistic effects tracked by state-of-the-art GR-RMHD simulations (ε{sub ∙}≃0.03). The supermassive black hole properties are tied to the X-ray halo temperature T{sub x}, or related cosmic scaling relation (as L{sub x}). The model is minimally based on first principles, such as conservation of energy and mass recycling. The inflow occurs via chaotic cold accretion (CCA), the rain of cold clouds condensing out of the quenched cooling flow and then recurrently funneled via inelastic collisions. Within 100s gravitational radii, the accretion energy is transformed into ultrafast 10{sup 4} km s{sup −1} outflows (UFOs) ejecting most of the inflowing mass. At larger radii, the energy-driven outflow entrains progressively more mass: at roughly kiloparsec scale, the velocities of the hot/warm/cold outflows are a few 10{sup 3}, 1000, and 500 km s{sup −1}, with median mass rates ∼ 10, 100, and several 100 M{sub ⊙} yr{sup −1}, respectively. The unified CCA model is consistent with the observations of nuclear UFOs and ionized, neutral, and molecular macro outflows. We provide step-by-step implementation for subgrid simulations, (semi)analytic works, or observational interpretations that require self-regulated AGN feedback at coarse scales, avoiding the a-posteriori fine-tuning of efficiencies.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-552: A One-Year Evaluation of the QABeamChecker+ for Use with the CyberKnife System

Purpose: By attaching an adapter plate with fiducial markers to the QA BeamChecker+ (Standard Imaging, Inc., Middleton, WI), the output of the CyberKnife can be accurately, efficiently, and consistently evaluated. The adapter plate, known as the Cutting Board, allows for automated alignment of the QABC+ using the CK’s stereoscopic kV image-based treatment localization system (TLS). Described herein is an evaluation of the system following a year of clinical utilization. Methods: Based on a CT scan of the QABC+ and CB, a treatment plan is generated which delivers a beam to each of the 5 plane-parallel ionization chambers. Following absolute calibration of the CK, the QA plan is delivered, and baseline measurements are acquired (and automatically corrected for temperature and pressure). This test was performed at the beginning of each treatment day for a year. A calibration evaluation (using a water-equivalent slab and short thimble chamber) is performed every four weeks, or whenever the QABC+ detects a deviation of more than 1.0%. Results: During baseline evaluation, repeat measurements (n=10) were performed, with an average output of 0.25% with an SD of 0.11%. As a test of the reposition of the QABC+ and CB, ten additional measurements were performed where between each acquisition, the entire system was removed and re-positioned using the TLS. The average output deviation was 0.30% with a SD of 0.13%. During the course of the year, 187 QABC+ measurements and 13 slab-based measurements were performed. The output measurements of the QABC+ correlated well with slab-based measurements (R2=0.909). Conclusion: By using the QABC+ and CB, daily output was evaluated accurately, efficiently, and consistently. From setup to break-down (including analysis), this test required 5 minutes instead of approximately 15 using traditional techniques (collimator-mounted ionization chambers). Additionally, by automatically saving resultant output deviation to a database, trend analysis was simplified. Spectrum Medical Physics, LLC of Greenville, SC has a consulting contract with Standard Imaging of Middleton, WI.

60 APPLIED LIFE SCIENCES↗

Collider-quality electron bunches from an all-optical plasma photoinjector

We present an approach for generating collider-quality electron bunches using a plasma photoinjector. The approach leverages recently developed techniques for the spatiotemporal control of laser pulses to produce a moving ionization front in a nonlinear plasma wave. The moving ionization front generates an electron bunch with a current profile that balances the longitudinal electric field of an electron beam-driven plasma wave, creating a uniform accelerating field across the bunch. Particle-in-cell (PIC) simulations of the ionization stage show the formation of an electron bunch with 220 pC charge and low emittance (ɛ 𝑥 = 171 nm rad, ɛ 𝑦 = 76 nm rad). Quasistatic PIC simulations of the acceleration stage show that the bunch is efficiently accelerated to 24 GeV over 2 m with a final energy spread of less than 1% and emittances of ɛ 𝑥 = 189 nm rad and ɛ 𝑦 = 80 nm rad. This high-quality electron bunch meets the requirements outlined by the Snowmass process for intermediate-energy colliders and compares favorably to the beam quality of proposed and existing accelerator facilities. The results establish the feasibility of plasma photoinjectors for future collider applications making a significant step toward the realization of high-luminosity, compact accelerators for particle physics research.

43 PARTICLE ACCELERATORS↗