Search NASA⌕ Search

SEARCH · Search NASA

Results for “mean squared error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Quantification of Lanthanides in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy

To enable the deployment of molten salt reactor technology, the development of off-gas treatment systems and advanced monitoring tools capable of operating with high temperatures and radiation fields while delivering near real-time information is necessary. Here, we aim to fulfill this requirement and proposes laser-induced breakdown spectroscopy (LIBS) for monitoring molten salt aerosol streams. A sheath gas measuring method was developed to protect optical elements from aerosol particles and to ensure a relatively constant aerosol stream for measurement. An aqueous system was studied to demonstrate the utility of LIBS for monitoring possible fission products in an aerosol stream: Gd, Nd, and Sm up to 2000 parts per million (ppm). A calibration model was built using partial least squares (PLS) regression with five, six, and nine latent variables for Gd, Nd, and Sm, respectively. This calibration model successfully estimated the concentrations of three test samples, which were validated with inductively charged plasma optical emission spectroscopy measurements at a 99.9% confidence interval. To enhance these models, a genetic algorithm was used to filter the spectra before entering the PLS model, thereby limiting the spectral features being regressed to those with greater correlations to concentration. This allowed for the number of latent variables used in the PLS models to be reduced to four, three, and three for Gd, Nd, and Sm, respectively. Finally, the genetic algorithm-filtered PLS models were used to predict the concentrations of the aerosol stream on a real-time dataset and resulted in a 73%, 18%, and 25% improvement in root mean squared error of prediction compared to the original PLS models developed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monitoring Noble Gases (Xe and Kr) and Aerosols (Cs and Rb) in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy (LIBS)

In this study with surrogate materials we show that laser-induced breakdown spectroscopy (LIBS) is a robust tool with promising capability toward monitoring gaseous (Xe and Kr) and aerosol (Cs and Rb) species in an off-gas stream from a molten salt reactor (MSR). MSRs will continually evolve fission products into the cover gas flowing across the reactor headspace. The cover gas entrains Xe and Kr gases, along with aerosol particles, before passing into an off-gas treatment system. Univariate models of Xe and Kr peaks showed a strong correlation to concentration indicated by their coefficients of determination of 0.983 and 0.997, respectively. Multivariate models were built for all four analytes using partial least squares regression coupled with preprocessing steps including normalization, trimming, and/or genetic algorithm derived filters. The models were evaluated by predicting the concentrations of the analytes in four validation samples, in which all calibration models were successfully validated at a confidence interval of 99.9%. Finally, pressure controllers were used to regulate the mass flow rate of Kr flowing into the measurement cell in sinusoidal and stepwise waveforms to test the real-time monitoring capabilities of the regression models. Both univariate and partial least squares Kr models were able to successfully quantify the gas concentration in the real-time evaluation. The root mean squared error of prediction (RMSEP) values for these real-time tests were calculated to be 0.051, 0.060, and 0.121 mol% demonstrating the measurement systems’ capability to perform online monitoring with acceptable accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization and Optimization of a Spectral Window for Direct Gaseous Uranium Hexafluoride Enrichment Assay Using Laser-Induced Breakdown Spectroscopy

Through a systematic scanning of 235 U and 238 U emission lines between 280 nm and 745 nm, the optimal emission line for direct gaseous uranium hexafluoride (UF 6 ) enrichment assay using laser-induced breakdown spectroscopy (LIBS) was found. Screening for spectral features that are potentially useful for U isotopic analysis was gauged from the magnitude of the 235 U– 238 U isotopic shift and the signal-to-background ratio of the emission line through a parameter termed ΔSBR 235U–238U . The ΔSBR spectrum shows peaks at wavelength positions where there are strong lines with significant 235 U– 238 U shifts. The screening identified 13 spectral-window candidates, which were down selected based on their overall accuracy in predicting the 235 U enrichment of three UF 6 samples of natural (0.720 atom% 235 U) and low-enriched (4.675 atom% and 9.157 atom% 235 U) grades. The U(I) 646.498 nm emission line, with a determined 235 U– 238 U isotopic shift of -17.7 pm, was found to be the optimal spectral window for direct UF 6 enrichment assay. The root mean square error for enrichment assays on the three natural and low-enriched UF 6 samples, with each sample measured in six replicates, was 0.31% in absolute 235 U content. Each measurement comprised LIBS signals accumulated from 3000 laser shots. In conclusion, the analytical bias and precision were better than 0.5% and 0.3%, respectively, in absolute [ 235 U/( 235 U + 238 U)] ratios. Specific for the two low-enriched UF 6 samples, the relative standard deviations from six replicated measurements were around 2%.

47 OTHER INSTRUMENTATION↗

Spectral Data Fusion From Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and X-ray Fluorescence (XRF) Analyzers for Improved Detection of Cerium in a Simulated Dispersal Accident

Here, this work implements a mid-level data fusion methodology on spectral data from handheld X-ray fluorescence and laser-induced breakdown spectroscopy analyzers to quantify plutonium surrogate (CeO 2 ) contamination in soil samples for the first time. Spectral data from each analyzer were used independently to train supervised machine learning regressions to predict Ce concentration. Fused features from both data sets were then used to train the same models, comparing prediction performance by evaluating model precision and sensitivity. Fusing principal component scores from the two sensors yielded an order of magnitude improvement in precision and sensitivity of predictions made with an artificial neural network, compared to predictions made by models trained on independent sensor data. As a result, a boosted ensemble trained on the fused spectral features yielded an ideal predictor with root-mean-squared error on the order of 10 –6 and calculated limit of detection order 10 –5 wt %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monitoring Sulfuric Acid and Temperature Using Raman Spectroscopy and Multivariate Chemometrics

Multivariate regression models were optimized for the quantification of sulfuric acid (H 2 SO 4 ) [0–8 M] and temperature (20 °C–80 °C) in the presence of ammonium sulfate ((NH 4 ) 2 SO 4 [0–0.6 M]) using Raman spectroscopy. Optical vibrational spectroscopy is a useful nondestructive technique for the in situ analysis of complex chemical systems notoriously difficult to monitor in situ and in real-time. Multivariate analysis, a chemometrics method, can be paired with these nondestructive optical methods for determining analyte concentration and speciation in complex solutions, such as dissociated species in polyprotic acids, e.g., H 2 SO 4 . The effect of temperature is often overlooked although it can have a major influence on speciation and the corresponding Raman spectra. Here, in this study, partial least squares regression models were optimized for the quantification of H 2 SO 4 and its two deprotonated forms as a function of temperature. Measuring bisulfate as a function of temperature is particularly challenging owing to changes in the second dissociation constant. A designed training set effectively minimized the sample set size and trained a robust predictive model with percent root mean square error of <3% for H 2 SO 4 . The practical strategy employed here was demonstrated to be effective for building chemometric models that directly account for dynamic temperatures with static samples and is shown to be amenable to flow cell analysis applications with a simple calibration transfer for process monitoring applications.

D-optimal design↗

Design of a Molten Salt Flow Cell for Combined Absorbance and Laser-Induced Breakdown Spectroscopy for Online Measurements

A novel flow cell allowing for multiple optical spectroscopy measurements on flowing molten salts was designed, and demonstrative calibrations of impurities in aqueous samples were performed. Online compositional measurements of molten salts are of high interest to monitor the state of relevant solar and nuclear systems. Here, the Spectroscopic Configuration for Optical Real-Time Characterization of High-Temperature (SCORCH) fluids cell was designed to meet this need by providing optical access to a high-temperature molten salt sample stream without physical contact between the sample and window materials. Laser-induced breakdown spectroscopy (LIBS) was utilized to quantify Li, Cr, Fe, Ni, Sr, and Pr at concentrations ranging nominally from 0 to 315 mmol L −1 . Laser power, frequency, and plasma position were optimized to mitigate challenges associated with sample splashing. Univariate calibration models were built with R 2 > 0.98, percent root mean square error of cross-validation (%RMSECV) as low as 2.7%, and limits of quantification (LOQs) down to 4.1 mmol L −1 . Simultaneously, absorbance calibrations were developed for the applicable analytes (Cr, Ni, and Pr) using Beer’s law with a pathlength of 4.41 ± 0.10 mm. These models provide excellent quantification performance with R 2 > 0.999, %RMSECV as low as 0.6%, and LODs down to 0.08 mmol L −1 . Although these calibrations were performed for each spectroscopic technique separately, the two methods may be combined in the future through multivariate modeling and sensor fusion to provide more robust models with the benefits of both techniques (e.g., absorbance: oxidation state concentrations, LIBS: elemental concentration). Additionally, optimized spectrometers may be deployed to enhance sensitivity.

absorbance spectroscopy↗

Z-checker: A framework for assessing lossy compression of scientific data

Because of the vast volume of data being produced by today’s scientific simulations and experiments, lossy data compressor allowing user-controlled loss of accuracy during the compression is a relevant solution for significantly reducing the data size. However, lossy compressor developers and users are missing a tool to explore the features of scientific data sets and understand the data alteration after compression in a systematic and reliable way. To address this gap, we have designed and implemented a generic framework called Z-checker. On the one hand, Z-checker combines a battery of data analysis components for data compression. On the other hand, Z-checker is implemented as an open-source community tool to which users and developers can contribute and add new analysis components based on their additional analysis demands. In this article, we present a survey of existing lossy compressors. Then, we describe the design framework of Z-checker, in which we integrated evaluation metrics proposed in prior work as well as other analysis tools. Specifically, for lossy compressor developers, Z-checker can be used to characterize critical properties (such as entropy, distribution, power spectrum, principal component analysis, and autocorrelation) of any data set to improve compression strategies. For lossy compression users, Z-checker can detect the compression quality (compression ratio and bit rate) and provide various global distortion analysis comparing the original data with the decompressed data (peak signal-to-noise ratio, normalized mean squared error, rate–distortion, rate-compression error, spectral, distribution, and derivatives) and statistical analysis of the compression error (maximum, minimum, and average error; autocorrelation; and distribution of errors). Z-checker can perform the analysis with either coarse granularity (throughout the whole data set) or fine granularity (by user-defined blocks), such that the users and developers can select the best fit, adaptive compressors for different parts of the data set. Z-checker features a visualization interface displaying all analysis results in addition to some basic views of the data sets such as time series. To the best of our knowledge, Z-checker is the first tool designed to assess lossy compression comprehensively for scientific data sets.

97 MATHEMATICS AND COMPUTING↗

Comparing Designed Training Sets to Optimize Multivariate Regression Models for Pr, Nd, and Nitric Acid Using Spectrophotometry

Chemometric regression models were developed for the quantification of praseodymium (Pr, 0–1000 µg/mL), neodymium (Nd, 0–1000 µg/mL), and nitric acid (HNO 3 , 0.1–5 M) using spectrophotometry. Designed calibration sets were composed of 20 samples each: 10 model points and 10 lack-of-fit (LOF) points. The D-optimal designs effectively minimized the number of samples required to build models, and each design resulted in similar prediction performance, suggesting that statistical design of experiments can provide a reliable framework for selecting training set samples in three-variable systems. Partial least squares regression (PLSR) models were validated against a one-factor-at-a-time validation set composed of 125 samples (three variables, five levels). The top PLS-1 models resulted in average percent root mean square error of prediction error values of 3.5%, 1.7%, and 1.2% for Pr(III), Nd(III), and HNO 3 , respectively. Power set augmentations of the model and LOF samples were investigated to optimize the number of training set samples. PLSR models built using just required model points (10) had similar predictive capabilities as models including the LOF points (20) but with fewer samples. The number of validation samples was also varied systematically to learn how many samples are needed to validate regression models. This work addresses long-standing questions in the field of chemometrics to help make this approach amenable to the near-real-time quantification of hazardous species in remote settings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DeepDist: real-value inter-residue distance prediction with deep residual convolutional network

Abstract Background Driven by deep learning, inter-residue contact/distance prediction has been significantly improved and substantially enhanced ab initio protein structure prediction. Currently, most of the distance prediction methods classify inter-residue distances into multiple distance intervals instead of directly predicting real-value distances. The output of the former has to be converted into real-value distances to be used in tertiary structure prediction. Results To explore the potentials of predicting real-value inter-residue distances, we develop a multi-task deep learning distance predictor (DeepDist) based on new residual convolutional network architectures to simultaneously predict real-value inter-residue distances and classify them into multiple distance intervals. Tested on 43 CASP13 hard domains, DeepDist achieves comparable performance in real-value distance prediction and multi-class distance prediction. The average mean square error (MSE) of DeepDist’s real-value distance prediction is 0.896 Å 2 when filtering out the predicted distance ≥ 16 Å, which is lower than 1.003 Å 2 of DeepDist’s multi-class distance prediction. When distance predictions are converted into contact predictions at 8 Å threshold (the standard threshold in the field), the precision of top L/5 and L/2 contact predictions of DeepDist’s multi-class distance prediction is 79.3% and 66.1%, respectively, higher than 78.6% and 64.5% of its real-value distance prediction and the best results in the CASP13 experiment. Conclusions DeepDist can predict inter-residue distances well and improve binary contact prediction over the existing state-of-the-art methods. Moreover, the predicted real-value distances can be directly used to reconstruct protein tertiary structures better than multi-class distance predictions due to the lower MSE. Finally, we demonstrate that predicting the real-value distance map and multi-class distance map at the same time performs better than predicting real-value distances alone.

59 BASIC BIOLOGICAL SCIENCES↗

Generation of synthetic dielectric dispersion logs in organic-rich shale formations using neural-network models

Dielectric dispersion (DD) logs acquired in subsurface geologic formations generally are composed of conductivity ([Formula: see text]) and relative permittivity ([Formula: see text]) measurements at four discrete frequencies in the range of 10 MHz to 1 GHz. Acquisition of DD logs in subsurface formations is operationally challenging, and it requires a hard-to-deploy infrastructure. We developed three supervised neural-network-based predictive methods to process conventional, easy-to-acquire subsurface logs for generating the eight DD logs acquired at four frequencies. These predictive methods will improve reservoir characterization in the absence of a DD logging tool. The predictive methods are tested in three wells intersecting organic-rich shale formations of the Permian Basin and the Bakken Shale. The first method predicts the eight dispersion logs simultaneously using a single artificial neural network (ANN) model, whereas the second method simultaneously predicts the four conductivity dispersion logs using one ANN model, followed by simultaneous prediction of four permittivity dispersion logs using a second ANN model. The third method sequentially predicts the eight dispersion logs, one at a time using eight sequential ANN models, based on a predetermined ranking of the prediction accuracy for each of the eight DD logs when simultaneously generated. Considering that the conventional and DD logs are recorded more than 10,000 ft deep in the subsurface using logging tools that are run at different times in rugose boreholes for sensing the near-wellbore geologic formation, the data used in this predictive work is prone to noise and biases that tend to adversely affect the prediction performances of the proposed methods. In terms of normalized root-mean square error (Nrms error), the prediction performances of the second predictive method are 8.5% worse and 6.2% better for the conductivity and permittivity dispersion logs, respectively, as compared with those of the first predictive method. The third method has best prediction performance for permittivity dispersion logs, which is 0.089 in terms of the Nrms error.

Geochemistry & Geophysics↗

Machine learning-based inversion for acoustic impedance with large synthetic training data: Workflow and data characterization

Where wells are sparse or training data are difficult to label with high-quality wireline-derived impedance logs, machine learning (ML)-based inversion of acoustic impedance typically depends on small training data sets, leading to biased prediction. We have advanced a novel workflow that applies large synthetic seismic training data to reduce facies-related bias. Using a geologically realistic model as the truth model, we randomly select sparse seed wells to perform sequential Gaussian simulation (SGS) for impedance models of the same geometry and simulate facies variability. We implement random forest regression on 30 features extracted from the synthetic volume. We observe that more seed wells tend to reduce facies-induced bias by sampling more types of facies, resulting in a better prediction. We then focus on the responses of SGS models to facies changes, the number of seed wells necessary for a useful synthetic model, and how much a synthetic model can help ML-based inversion. Here, we observe that the SGS synthetic training model outperforms well-direct training in general. For modeled clastic shore-zone systems in Miocene Gulf of Mexico, two or more seed wells are necessary for a significant reduction of root-mean-square error and outliners, and improvement of facies imaging. In a field-data test, we apply a similar workflow to quantitatively predict acoustic impedance, which is then converted to a sand-volume map at a high-frequency sequence (10–100 m), revealing detailed facies and sandstone patterns. Such results are valuable in many geologic and engineering applications, such as hydrocarbon and CO 2 reservoir prospecting, reserve estimation, simulation, etc.

3D seismic↗

Application of a new hybrid particle swarm optimization-mixed kernels function-based support vector machine model for reservoir porosity prediction: A case study in Jacksonburg-Stringtown oil field, West Virginia, USA

Porosity is a fundamental property that characterizes the storage capability of fluid and gas-bearing formations in a reservoir. An accurate porosity value can be measured from core samples in the laboratory; however, core analysis is expensive and time consuming. Well-log data can be used to calculate porosity, but the availability of log suites is often limited in mature fields. Therefore, robust porosity prediction requires integration of core-measured porosity with available well-log suites to control for changes in lithology and fluid content. A support vector machine (SVM) model with mixed kernel function (MKF) is used to construct the relationship between limited conventional well-log suites and sparse core data. Porosity is the desired output, and two conventional well-log responses (gamma ray [GR] and bulk density) and three well-log-derived parameters (the slope of GR, the slope of density, and [Formula: see text]) are input parameters. A global stochastic searching algorithm, particle swarm optimization (PSO), is applied to improve the efficiency of locating the appropriate values of five control parameters in MKF-SVM model. The results of SVM with different traditional kernel functions were compared, and the MKF-SVM model provided an improvement over the traditional SVM model. To confirm the advantage of the hybrid PSO-MKF-SVM model, the results from three models: (1) radial basis function (RBF)-based least-squares SVM, (2) multilayer perceptron artificial neural network (ANN), and (3) RBF ANN, are compared with the result of the hybrid PSO-MKF-SVM model. The results indicate that the hybrid PSO-MKF-SVM model improves porosity prediction with the highest correlation coefficient ([Formula: see text] of 0.9560), the highest coefficient of determination ([Formula: see text] of 0.9140), the lowest root-mean-square error (1.6505), average absolute error value (1.4050), and maximum absolute error (2.717).

Geochemistry & Geophysics↗

Data for Influence of Particle Size on NIR Spectroscopic Characterization of Sorghum Biomass for the Biofuel Industry

NIR spectroscopy is a rapid and accurate green technology for high-throughput biomass characterization, including sorghum ( Sorghum bicolor ), a promising energy crop for the biofuel industry. This study assessed the influence of particle size on NIR spectroscopic analysis (wavelength range: 867–2535 nm) of sorghum biomass composition. Grown under field conditions, a total of 113 types of genetically diverse sorghum accessions were dried, ground, and sieved (<250, 250–600, 600–850, and > 850 µm particle size) for developing partial least square regression (PLSR) prediction models for moisture, ash, extractive, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin (ASL + AIL). Overall, smaller particle sizes provided better model performance, while no single particle size provided the best performance for all the selected components. With only 9 selected bands and 4 latent variables (LVs), the best PLSR model was obtained for moisture with particle size of 600–850 µm with the square root of the coefficient of determination (R) of 0.85, the ratio of prediction to deviation (RPD) of 2.2, and the root mean square error (RMSE) of 0.46 % in external validation. Similar model performances were also obtained for ash, extractive, glucan, and xylan. This study showed that size reduction could effectively improve NIR spectroscopic analysis for lipid-producing sorghum biomass for the biofuel industry.

Biomass Analytics↗

Data for Soil Oxygen Dynamics: A Key Mediator of Tile Drainage Impacts on Coupled Hydrological, Biogeochemical, and Crop Systems

Tile drainage removes excess water and is an essential, widely adopted management practice to enhance crop productivity in the US Midwest and throughout the world. Tile drainage has been shown to significantly change hydrological and biogeochemical cycles by lowering the water table and reducing the residence time of soil water, although examining the complex interactions and feedbacks in an integrated hydrology–biogeochemistry–crop system remains elusive. Oxygen dynamics are critical to unraveling these interactions and have been ignored or oversimplified in existing models. Understanding these impacts is essential, particularly so because tile drainage has been highlighted as an adaptation under projected wetter springs and drier summers in the changing climate in the US Midwest. We used the ecosys model that uniquely incorporates first-principle soil oxygen dynamics and crop oxygen uptake mechanisms to quantify the impacts of tile drainage on hydrological and biogeochemical cycles and crop growth in corn–soybean rotation fields. The model was validated with data from a multi-treatment, multi-year experiment in Washington, IA. The relative root mean square error (rRMSE) for the corn and soybean yield in validation is 5.66 % and 12.57 %, respectively. The Pearson coefficient (r) of the monthly tile flow during the growing season is 0.78. Plant oxygen stress turns out as an emergent property of the equilibrium between the soil oxygen supply and biological demand. The impact of tile drainage on the system is achieved through a series of coupled feedback mechanisms. The model results show that tile drainage reduces the soil water content and enhances soil oxygenation. It additionally increases the subsurface discharge and elevates inorganic nitrogen leaching, with seasonal variations influenced by climate and crop phenology. The improved aerobic condition alleviates crop oxygen stress during wet springs, thereby promoting crop root growth during the early growth stage. The development of greater root density, in turn, mitigates water stress during dry summers, leading to an overall increase in the crop yield by ∼6 %. These functions indicate the potential of tile drainage in bolstering crop resilience to climate change and the use of this modeling tool for large-scale assessments of tile drainage. The model reveals the underlying causal mechanisms that drive the agroecosystem response to drainage on the coupled hydrology, biogeochemistry, and crop system dynamics.

Modeling↗

Lead Slowing Down Spectrometry Analysis of Data from Measurements on Nuclear Fuel

Improved non-destructive assay of isotopic masses in used nuclear fuel would be valuable for nuclear safeguards operations associated with the transport, storage and reprocessing of used nuclear fuel. Our collaboration is examining the feasibility of using lead slowing down spectrometry techniques to assay the isotopic fissile masses in used nuclear fuel assemblies. We present the application of our analysis algorithms on measurements conducted with a lead spectrometer. The measurements involved a single fresh fuel pin and discrete 239Pu and 235U samples. We are able to describe the isotopic fissile masses with root mean square errors over seven different configurations to 6.35% for 239Pu and 2.7% for 235U over seven different configurations. Funding Source(s):

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CEFR simulation using diffusion code system RAST-F

In this study, the RAST-F code system, which is based on the two-step approach that couples a multi-group cross-section generation Monte-Carlo (MC) code and a multi-group nodal diffusion solver, was used for the neutronic simulation of the CEFR start-up experiments. The numerical solution of the RAST-F system was verified against the full core MC solution MCS at all control rods fully inserted and withdrawn states. The RAST-F solution of the selected experimental simulations was compared against the measurement data. A good agreement between RAST-F and MCS solutions was observed with less than 120 pcm discrepancies and 1.2% root-mean-square error in terms of k{sub eff} and power distribution, respectively. Meanwhile, the RAST-F result agreed well with the experimental data within two-sigma of experimental uncertainty. The good agreement of these results indicates that RAST-F can be used to neutronic steady-state simulations for small core-size SFR, which was challenged to deterministic code systems. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of advanced machine learning models for analysis of plutonium surrogate optical emission spectra

This work investigates and applies machine learning paradigms seldom seen in analytical spectroscopy for quantification of gallium in cerium matrices via processing of laser-plasma spectra. Ensemble regressions, support vector machine regressions, Gaussian kernel regressions, and artificial neural network techniques are trained and tested on cerium-gallium pellet spectra. A thorough hyperparameter optimization experiment is conducted initially to determine the best design features for each model. The optimized models are evaluated for sensitivity and precision using the limit of detection (LoD) and root mean-squared error of prediction (RMSEP) metrics, respectively. Gaussian kernel regression yields the superlative predictive model with an RMSEP of 0.33% and an LoD of 0.015% for quantification of Ga in a Ce matrix. This study concludes that these machine learning methods could yield robust prediction models for rapid quality control analysis of plutonium alloys.

Rao, Ashwin P. (ORCID:0000000319312568)↗