Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Use of an Electron Beam for Stochastic Cooling

Microwave instability of an electron beam can be used for a multiple increase in the collective response for the perturbation caused by a particle of a co-moving ion beam, i.e. for enhancement of friction force in electron cooling method. The low scale (hundreds GHz and higher frequency range) space charge or FEL type instabilities can be produced (depending on conditions) by introducing an alternating magnetic fields along the electron beam path. Beams’ optics and noise conditioning for obtaining a maximal cooling effect and related limitations will be discussed. The method promises to increase by a few orders of magnitude the cooling rate for heavy particle beams with a large emittance for a wide energy range with respect to either electron and conventional stochastic cooling.

43 PARTICLE ACCELERATORS↗

Assessment of MRI Parameters as Imaging Biomarkers for Radiation Necrosis in the Rat Brain

Purpose: Radiation necrosis is a major complication of radiation therapy. We explore the features of radiation-induced brain necrosis in the rat, using multiple MRI approaches, including T{sub 1}, T{sub 2}, apparent diffusion constant (ADC), cerebral blood flow (CBF), magnetization transfer ratio (MTR), and amide proton transfer (APT) of endogenous mobile proteins and peptides. Methods and Materials: Adult rats (Fischer 344; n = 15) were irradiated with a single, well-collimated X-ray beam (40 Gy; 10 Multiplication-Sign 10 mm{sup 2}) in the left brain hemisphere. MRI was acquired on a 4.7-T animal scanner at {approx}25 weeks' postradiation. The MRI signals of necrotic cores and perinecrotic regions were assessed with a one-way analysis of variance. Histological evaluation was accomplished with hematoxylin and eosin staining. Results: ADC and CBF MRI could separate perinecrotic and contralateral normal brain tissue (p < 0.01 and < 0.05, respectively), whereas T{sub 1}, T{sub 2}, MTR, and APT could not. MRI signal intensities were significantly lower in the necrotic core than in normal brain for CBF (p < 0.001) and APT (p < 0.01) and insignificantly higher or lower for T{sub 1}, T{sub 2}, MTR, and ADC. Histological results demonstrated coagulative necrosis within the necrotic core and reactive astrogliosis and vascular damage within the perinecrotic region. Conclusion: ADC and CBF are promising imaging biomarkers for identifying perinecrotic regions, whereas CBF and APT are promising for identifying necrotic cores.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of experimental and computational frameworks to predict subcooled flow boiling in the LANL Isotope Production Facility

Cooling is crucial to maintain the integrity of target systems in isotope production facilities. At Los Alamos National Laboratory (LANL)’s Isotope Production Facility (IPF), multiple encapsulated targets are stacked and irradiated in tandem with a 100 MeV, ~250μA proton beam. To facilitate effective heat removal, these stacked targets are separated and cooled via a series of water channels. At these beam currents, this high-energy proton beam heats the target system, likely initiating subcooled flow boiling in the cooling channels. However, in-beam monitoring of the IPF target system is not possible due to the extreme radiation environment, and the necessarily significant shielding. To better understand high-power target performance, we developed ex-situ experimental and computational frameworks to predict the behavior of subcooled flow boiling at IPF. Subcooled flow boiling experiments on Inconel 625 samples under IPF conditions (2 bar pressure, 10 GPM flow rate (i.e., 2249 kg/m 2 /s), 85 K subcooling) revealed that IPF's average operating power is at the early stage of boiling with a heat transfer coefficient of 48,000 W/m 2 /s. The proposed modeling framework enables us to predict a complete boiling curve, i.e., single-phase heat transfer, onset of nucleate boiling, two-phase heat transfer, and critical heat flux (CHF), with specification of input boiling parameters up to intermediate heat flux levels. The estimated CHF under IPF conditions is 5.2 MW/m 2 . Experimental data under reduced conditions (2 bar pressure, 1.5 GPM flow rate (i.e., 337 kg/m 2 /s), 45 K subcooling) served as validation cases for the computational modeling. This computational model can be further extended to more complicated systems replicating the real IPF configuration, for instance, to study void distribution as a function of the incident proton beam profile and coolant velocity profile of multiple cooling channels. Finally, the proposed experimental and computational frameworks provide a means to better understand cooling systems in the isotope production facilities at different accelerators, where in-beam monitoring of the cooling process is not available.

07 ISOTOPE AND RADIATION SOURCES↗

Iodine photodissociation laser with an intracavity space - time light modulator

A scheme of an iodine laser with two different intracavity space - time modulators based on electrooptic PLZT ceramics is experimentally studied. It is shown that lasing can occur in different angular directions with the use of both modulators. The output laser energy is 10 mJ with a pulse duration of 200 {mu}s and a beam divergence of 6.3 Multiplication-Sign 10{sup -4} rad. The laser field of view (5.1 Multiplication-Sign 10{sup -3} rad) consists of a discrete set of 8 Multiplication-Sign 8 directions. (control of laser radiation parameters)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field validation of an actuated convergent-beam acoustic Doppler profiler for high resolution flow mapping

Abstract Energetic river and tidal flow environments feature complex hydrodynamic conditions. Conventional acoustic Doppler profiling instrumentation typically requires assumptions of flow homogeneity over the spatial scales of the divergent beam separation. This removes the ability to measure spatio-temporal variability within the flow. However, velocity variability within these spatial scales is often important in the design of structures and devices exposed to such flow, informing dynamic and peak hydrodynamic load predictions. The research presented outlines the development and testing of a flow measurement instrument consisting of multiple spatially-separated single beam acoustic Doppler profilers converging on a remote focal point, the location of which can be programmatically adjusted through actuation. This increases the spatial resolution at which remote field measurements can be made in energetic flow environments. Field testing of the instrument was conducted in a tidal channel at Sequim Bay Inlet, WA, USA. Results are compared with independent reference measurements made by a co-located, motion-corrected acoustic Doppler velocimeter. This comparison, across tidal velocities of 0.4–0.7 m s −1 , showed a mean velocity error of 0.5%–13.2% across nine sample locations within a 3.00 m × 2.25 m plane. To the authors’ knowledge, this is the first publication of flow velocity results from non-intrusive acoustic measurements at an off-axis, focal point location that features 3D positional control.

13 HYDRO ENERGY↗

Amplitude and phase-shaping effects in beamwaveguides

Results are presented of an investigation on improvements in a geometrical optics (GO) design of a beam-waveguide antenna for operation at multiple frequency bands. Improvements might be possible by changing the design of the lower-frequency input pattern to the beam waveguide. The effects of amplitude and phase shaping the input pattern have been studied with an aperture diffraction model. Accurate vector near-field computations were made rapidly with a spherical wave expansion of the input and scattered fields. Numerical results indicate that for aperture sizes of less than 30 wavelengths, there is insufficient control on defocusing due to amplitude and phase shaping. Design tradeoffs on spillover loss and defocusing are possible by changing the amplitude and phase distribution of the input wavefront for larger size apertures.

Rengarajan, Sembiam R.↗

Supersonic helium beam diagnostic for fluctuation measurements of electron temperature and density at the Tokamak TEXTOR

A supersonic helium beam diagnostic, based on the line-ratio technique for high resolution electron density and temperature measurements in the plasma edge (r/a > 0.9) was designed, built, and optimised at TEXTOR (Torus Experiment for Technology Oriented Research). The supersonic injection system, based on the Campargue skimmer-nozzle concept, was developed and optimised in order to provide both a high neutral helium beam density of n{sub 0}= 1.5 Multiplication-Sign 10{sup 18} m{sup -3} and a low beam divergence of {+-}1 Degree-Sign simultaneously, achieving a poloidal resolution of {Delta}{sub poloidal}= 9 mm. The setup utilises a newly developed dead volume free piezo valve for operation in a high magnetic field environment of up to 2 T with a maximum repetition rate of 80 Hz. Gas injections are realised for a duration of 120 ms at a repetition rate of 2 Hz (duty cycle 1/3). In combination with a high sensitivity detection system, consisting of three 32 multi-channel photomultipliers (PMTs), measurements of edge electron temperature and density with a radial resolution of {Delta}{sub radial}= 2 mm and a maximum temporal resolution of {Delta}t Asymptotically-Equal-To 2 {mu}s (470 kHz) are possible for the first time. The diagnostic setup at TEXTOR is presented. The newly developed injection system and its theoretical bases are discussed. The applicability of the stationary collisional-radiative model as basis of the line-ratio technique is shown. Finally, an example of a fluctuation analysis demonstrating the unique high temporal and spatial resolution capabilities of this new diagnostic is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Abelian Bremsstrahlung and Azimuthal Asymmetries in High Energy p+A Reactions

Here we apply the GLV reaction operator solution to the Vitev-Gunion-Bertsch (VGB) boundary conditions to compute the all-order in nuclear opacity non-abelian gluon bremsstrahlung of event- by-event uctuating beam jets in nuclear collisions. We evaluate analytically azimuthal Fourier moments of single gluon, v$M\atop{n}$ {1}, and even number 2ℓ gluon, v$M\atop{n}$ {2ℓ} inclusive distributions in high energy p+A reactions as a function of harmonic $n$, target recoil cluster number, $M$, and gluon number, 2ℓ, at RHIC and LHC. Multiple resolved clusters of recoiling target beam jets together with the projectile beam jet form Color Scintillation Antenna (CSA) arrays that lead to character- istic boost non-invariant trapezoidal rapidity distributions in asymmetric B+A nuclear collisions. The scaling of intrinsically azimuthally anisotropic and long range in η nature of the non-Abelian bremsstrahlung leads to v n moments that are similar to results from hydrodynamic models, but due entirely to non-Abelian wave interference phenomena sourced by the fluctuating CSA. Our analytic non-flow solutions are similar to recent numerical saturation model predictions but differ by predicting a simple power-law hierarchy of both even and odd v n without invoking k T factorization. A test of CSA mechanism is the predicted nearly linear η rapidity dependence of the v n (k T η). Non- Abelian beam jet bremsstrahlung may thus provide a simple analytic solution to Beam Energy Scan (BES) puzzle of the near $\sqrt{s}$ independence of v n (pT) moments observed down to 10 AGeV where large-x valence quark beam jets dominate inelastic dynamics. Recoil bremsstrahlung from multiple independent CSA clusters could also provide a partial explanation for the unexpected similarity of v n in p(D) + A and non-central A + A at same dN=dη multiplicity as observed at RHIC and LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Loss Studies for Rare Isotope Driver Linacs Final Report

The Fortran 90 RIAPMTQ/IMPACT code package is a pair of linked beam-dynamics simulation codes that have been developed for end-to-end computer simulations of multiple-charge-state heavy-ion linacs for future exotic-beam facilities. These codes have multiple charge-state capability, and include space-charge forces. The simulations can extend from the low-energy beam-transport line after an ECR ion source to the end of the linac. The work has been performed by a collaboration including LANL, LBNL, ANL, and MSU. The code RIAPMTQ simulates the linac front-end beam dynamics including the LEBT, RFQ, and MEBT. The code IMPACT simulates the beam dynamics of the main superconducting linac. The codes have been benchmarked for rms beam properties against previously existing codes at ANL and MSU. The codes allow high-statistics runs on parallel supercomputing platforms, particularly at NERSC at LBNL, for studies of beam losses. The codes also run on desktop PC computers for low-statistics work. The code package is described in more detail in a recent publication [1] in the Proceedings of PAC07 (2007 US Particle Accelerator Conference). In this report we describe the main activities for the FY07 beam-loss studies project using this code package.

43 PARTICLE ACCELERATORS↗

A parallel variable population multi-objective optimizer for accelerator beam dynamics optimization

The simultaneous optimization of multiple objective functions is needed in many particle accelerator applications. In this paper, we present a parallel evolution based multi-objective optimizer that uses a variable population from generation to generation and an external storage to save good solutions. Two heuristic optimization methods, one uses the unified differential evolution and the other uses the real-coded genetic algorithm, are included in the optimizer to generate next generation candidate solutions, and are compared in the test examples. Finally, as an application, we applied this optimizer to the beam dynamics design optimization of a photoinjector and attained the optimal front solutions after 200 generations with the unified differential evolution offspring production scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The development of a room temperature electron cyclotron resonance ion source (Lanzhou electron cyclotron resonance ion source No. 4) with evaporative cooling technology at Institute of Modern Physics

LECR4 (Lanzhou electron cyclotron resonance ion source No. 4) has been successfully constructed at IMP and has also been connected with the Low Energy Beam Transport (LEBT) and Radio Frequency Quadrupole (RFQ) systems. These source magnet coils are cooled through evaporative cooling technology, which is the first attempt with an ECR ion source in the world. The maximum mirror field is 2.5 T (with iron plug) and the effective plasma chamber volume is 1.2 l. It was designed to be operated at 18 GHz and aimed to produce intense multiple charge state heavy ion beams for the linear injector project SSC-Linac at IMP. In February 2014, the first analyzed beam at 18 GHz was extracted. During about three months’ commissioning, some outstanding results have been achieved, such as 1.97 emA of O{sup 6+}, 1.7 emA of Ar{sup 8+}, 1.07 emA of Ar{sup 9+}, and 118 euA of Bi{sup 28+}. The source has also successfully delivered O{sup 5+} and Ar{sup 8+} ion beams for RFQ commissioning in April 2014. This paper will give a brief overview of the design of LECR4. Then, the latest results of this source at 18 GHz will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design study of primary ion provider for relativistic heavy ion collider electron beam ion source

Brookhaven National Laboratory has developed the new preinjector system, electron beam ion source (EBIS) for relativistic heavy ion collider (RHIC) and National Aeronautics and Space Administration Space Radiation Laboratory. Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

43 PARTICLE ACCELERATORS↗

MM-wave emission by magnetized plasma during sub-relativistic electron beam relaxation

There are described electromagnetic spectra of radiation emitted by magnetized plasma during sub-relativistic electron beam in a double plasma frequency band. Experimental studies were performed at the multiple-mirror trap GOL-3. The electron beam had the following parameters: 70–110 keV for the electron energy, 1–10 MW for the beam power and 30–300 μs for its duration. The spectrum was measured in 75–230 GHz frequency band. The frequency of the emission follows variations in electron plasma density and magnetic field strength. The specific emission power on the length of the plasma column is estimated on the level 0.75 kW/cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design study of primary ion provider for RHIC-EBIS

Brookhaven National Laboratory (BNL) has developed the new pre-injector system, Electron Beam Ion Source (EBIS) for Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

43 PARTICLE ACCELERATORS↗

Monte Carlo calculation of the average neutron depolarization for the NPDGamma experiment

The NPDGamma experiment measures the asymmetry in γ-ray emission in the capture of polarized neutrons on liquid parahydrogen. The beam polarization is measured using 3 He spin analysis, but this measurement does not account for the contribution of depolarization from spin–flip scattering primarily due to orthohydrogen in the bulk liquid. This is a systematic effect that dilutes the experimental asymmetry and is modeled using Monte Carlo. Finally, methods for tracking neutron spin in MCNPX were developed in order to calculate the average neutron polarization upon capture for use as a multiplicative correction to the measured beam polarization for the NPDGamma experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative study of treatment dose plans after the refinement of Leksell Gamma Knife registered single-beam dose profiles

We investigated the amplification of discrepancy when using multiple shots of the same collimator size helmet, by comparing dose plans in the Leksell GammaPlan registered employing the default single-beam dose profiles and the Monte Carlo generated single-beam profiles. Four collimator helmets were studied. The results show that the largest amplification of discrepancy with multiple shots was found with the 8 mm collimator because of the largest discrepancy of its single-beam dose profile. The amplification of discrepancy is significant when tumor volumes increase but insignificant when the tumor volumes are in an elongated shape. Using close shot overlapping strategy (i.e., more shots close packed together) shows no observable increase in the amplification of discrepancy. For the best quality of Leksell Gamma Knife registered radiosurgery, it is suggested that the single-beam dose profiles should be refined, especially the 8 mm collimator, to prevent error amplification when using multiple collimator shots.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Localized Dose Enhancement to Tumor Blood Vessel Endothelial Cells via Megavoltage X-rays and Targeted Gold Nanoparticles: New Potential for External Beam Radiotherapy

Purpose: Tumor endothelial cell damage during radiation therapy may contribute significantly to tumor eradication and treatment efficacy. Gold nanoparticles (AuNPs) delivered preferentially to the walls of tumor blood vessels produce low-energy, short-range photoelectrons during external beam radiotherapy, boosting dose to the tumor microvasculature. In this study dosimetry at the single-cell level is used to estimate the anticipated AuNP-mediated dose enhancement to tumor endothelial cells during 6-MV X-ray irradiation. Methods and Materials: Endothelial cells are modeled as thin slabs with 100-nm-diameter AuNPs attached within the blood vessel. The number of photoelectrons emitted per AuNP per gray of X-rays is computed at multiple points along the external beam central axis by use of a Monte Carlo-generated energy fluence spectrum. The energy deposited from AuNP emissions to the endothelium is calculated based on an analytic method incorporating the energy-loss formula of Cole. The endothelial dose enhancement factor (EDEF) is the ratio of the overall (externally plus internally generated) dose to endothelial cells in the presence of AuNPs to the dose without AuNPs (from the external beam only). Results: At 20-cm depth, the EDEF is 1.7 (70% dose increase) for an intravascular AuNP concentration of 30 mg/g. Most of this dose enhancement arises from the low-energy (approximately 100 keV) portion of the linear accelerator X-ray spectrum. Furthermore, for AuNP concentrations ranging from 7 to 140 mg/g, EDEF values of 1.2 to 4.4 (20-340% dose increase) are calculated. Conclusions: In contrast to calculations assuming that AuNPs distributed homogeneously throughout the target volume (macrodosimetry), our cellular microdosimetry calculations predict a major dose enhancement to tumor microvasculature from conventional linear accelerator X-rays. This effect may enable the delivery of ablative therapeutic doses to these sensitive microstructures while maintaining established dose constraints for the organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strain-Layer-Superlattice Light Modulator

Conceptual device combines resonant reflection and photovoltaic action to enable one light beam to impose spatial and temporal modulation on another light beam. Such spatial light modulator, with high speed and multiplicity of parallel signal channels, used in image processing or similar computation requiring high data-throughput rates. Microstructures of GaAs and InAs with multiple quantum wells and compositional superlattices grown by molecular-beam epitaxy. Enhanced electro-optical properties of arrangement of alternating layers enables writing light beam to modulate reading light beam.

Maserjian, Joseph↗