Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplicative correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Determination of transit dose profile for a {sup 192}Ir HDR source

Purpose: Several studies have reported methodologies to calculate and correct the transit dose component of the moving radiation source for high dose rate (HDR) brachytherapy planning systems. However, most of these works employ the average source speed, which varies significantly with the measurement technique used, and does not represent a realistic speed profile, therefore, providing an inaccurate dose determination. In this work, the authors quantified the transit dose component of a HDR unit based on the measurement of the instantaneous source speed to produce more accurate dose values. Methods: The Nucletron microSelectron-HDR Ir-192 source was characterized considering the Task Group 43 (TG-43U1) specifications. The transit dose component was considered through the calculation of the dose distribution using a Monte Carlo particle transport code, MCNP5, for each source position and correcting it by the source speed. The instantaneous source speed measurements were performed in a previous work using two optical fibers connected to a photomultiplier and an oscilloscope. Calculated doses were validated by comparing relative dose profiles with those obtained experimentally using radiochromic films. Results: TG-43U1 source parameters were calculated to validate the Monte Carlo simulations. These agreed with the literature, with differences below 1% for the majority of the points. Calculated dose profiles without transit dose were also validated by comparison with ONCENTRA{sup Registered-Sign} Brachy v. 3.3 dose values, yielding differences within 1.5%. Dose profiles obtained with MCNP5 corrected using the instantaneous source speed profile showed differences near dwell positions of up to 800% in comparison to values corrected using the average source speed, but they are in good agreement with the experimental data, showing a maximum discrepancy of approximately 3% of the maximum dose. Near a dwell position the transit dose is about 22% of the dwell dose delivered by the source dwelling 1 s and reached 104.0 cGy per irradiation in a hypothetical clinical case studied in this work. Conclusions: The present work demonstrated that the transit dose correction based on average source speed fails to accurately correct the dose, indicating that the correct speed profile should be considered. The impact on total dose due to the transit dose correction near the dwell positions is significant and should be considered more carefully in treatments with high dose rate, several catheters, multiple dwell positions, small dwell times, and several fractions.

60 APPLIED LIFE SCIENCES↗

Independent calculation of dose distributions for helical tomotherapy using a conventional treatment planning system

Purpose: The dosimetric verification of treatment plans in helical tomotherapy usually is carried out via verification measurements. In this study, a method for independent dose calculation of tomotherapy treatment plans is presented, that uses a conventional treatment planning system with a pencil kernel dose calculation algorithm for generation of verification dose distributions based on patient CT data. Methods: A pencil beam algorithm that directly uses measured beam data was configured for dose calculation for a tomotherapy machine. Tomotherapy treatment plans were converted into a format readable by an in-house treatment planning system by assigning each projection to one static treatment field and shifting the calculation isocenter for each field in order to account for the couch movement. The modulation of the fluence for each projection is read out of the delivery sinogram, and with the kernel-based dose calculation, this information can directly be used for dose calculation without the need for decomposition of the sinogram. The sinogram values are only corrected for leaf output and leaf latency. Using the converted treatment plans, dose was recalculated with the independent treatment planning system. Multiple treatment plans ranging from simple static fields to real patient treatment plans were calculated using the new approach and either compared to actual measurements or the 3D dose distribution calculated by the tomotherapy treatment planning system. In addition, dose–volume histograms were calculated for the patient plans. Results: Except for minor deviations at the maximum field size, the pencil beam dose calculation for static beams agreed with measurements in a water tank within 2%/2 mm. A mean deviation to point dose measurements in the cheese phantom of 0.89% ± 0.81% was found for unmodulated helical plans. A mean voxel-based deviation of −0.67% ± 1.11% for all voxels in the respective high dose region (dose values >80%), and a mean local voxel-based deviation of −2.41% ± 0.75% for all voxels with dose values >20% were found for 11 modulated plans in the cheese phantom. Averaged over nine patient plans, the deviations amounted to −0.14% ± 1.97% (voxels >80%) and −0.95% ± 2.27% (>20%, local deviations). For a lung case, mean voxel-based deviations of more than 4% were found, while for all other patient plans, all mean voxel-based deviations were within ±2.4%. Conclusions: The presented method is suitable for independent dose calculation for helical tomotherapy within the known limitations of the pencil beam algorithm. It can serve as verification of the primary dose calculation and thereby reduce the need for time-consuming measurements. By using the patient anatomy and generating full 3D dose data, and combined with measurements of additional machine parameters, it can substantially contribute to overall patient safety.

60 APPLIED LIFE SCIENCES↗

Causal Analysis Report for NA-SS-SNL-8000-2018-0002 Electrical shock: Wind Turbine Nacelle Lubbock TX

A Sandia National Laboratories Member of the Workforce (MOW) experienced contact with electrical energy while performing work on an oil filter pump electrical system in the al wind turbine nacelle at Sandia National Laboratories Scaled Wind Turbine Facility (SWiFT). The Department of Energy (DOE) Sandia National Laboratories (SNL) Scaled Wind Farm Technology (SWiFT) facility does research and development (R&D) work in collaboration with Texas Tech University. The SWiFT facility includes three turbines for performing wind plant and turbine technology research in support of DOE's Wind Energy Technology Office. The current work ongoing at the site is primarily related to commissioning the three turbines to support ongoing DOE customer needs and requests. It was during the performance of commissioning tests of the hydraulic systems in the a1 turbine that a Sandia MOW experienced contact with electrical energy. There were multiple root and contributing causes that ultimately resulted in the electrical energy contact. These causes are summarized and aligned to their corrective actions in the corrective action plan table provided in Section 7(c). The purpose of this narrative section is to provide additional information and context

17 WIND ENERGY↗

Power Hardware-in-the-Loop Testing of Distribution Solid State Transformers

Savannah River National Laboratory and Resilient Power Systems have developed a utility grade solid state transformer and are planning on deploying it for testing in January 2018. The solid state transformer is the next generation solution to implementation of distributed energy resources such as solar and batteries. They can directly connect the solar and battery systems to DC ports and rout power between these DC ports and load ports. The solid state transformer can revolutionize current grid modernization initiatives by supplying grid support and building support services at the edge of the grid. These services consist of volt-VAR optimization, power factor correction, voltage regulation, frequency regulation, fault current support, demand side management, DC bus for AC/DC capable houses, and power routing between multiple ports for transactive control. For this fiscal year a test plan for testing the SST capabilities was develop. Along with the FPGA controls for the SST output ports. These controls will allow for any waveform to be produced by each port of the SST. Finally, a hybrid distribution SST was tested at the eGRID resulting in medium voltage testing experience for SRNL engineering team. DOE is currently engaged, through the Building Technology Office and Infrastructure Security and Energy Restoration in future work building from this project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated Reconstruction, Signal Processing and Particle Identification in DUNE

Liquid Argon TPC (LArTPC) technology is increasingly prevalent in large-scale detectors designed to observe neutrino scattering events induced by accelerators or by natural sources. LArTPCs consist of a very high fraction of active detector material with spatial resolutions on the order of a few millimeters. Three-dimensional interactions are imaged in multiple two-dimensional views by the process of projection onto planes of wires. The goal of automated reconstruction is to correctly classify each neutrino scattering event by the flavor of the incoming neutrino, to separate charged-current events from neutral-current and other backgrounds, and to measure the energies of the incoming neutrinos. Detection of neutrinos from supernova bursts and also seaching for nucleon decay are important uses of automated reconstruction algorithms. Because the amount of spatial detail is high and the amount of scattering is high, this reconstruction presents many challenges that are now being investigated with sophisticated techniques.Signal processing, track and shower identification, particle identification, and event classification by a variety of innovative algorithms are reviewed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Thermal and Kinematic Sunyaev–Zeldovich Effect in Galaxy Clusters and Filaments Using Multifrequency Temperature Maps of the Cosmic Microwave Background: A399–A401 Cluster Pair Case Study

We present a multifrequency and multi-instrument methodology to study the physical properties of galaxy clusters and cosmic filaments using cosmic microwave background observations. Our approach enables simultaneous measurement of both the thermal (tSZ) and kinematic Sunyaev–Zeldovich (kSZ) effects, incorporates relativistic corrections, and models astrophysical foregrounds such as thermal dust emission. We do this by jointly fitting a single physical model across multiple maps from multiple instruments at different frequencies, rather than fitting a model to a single Compton-y map. We demonstrate the success of this method by fitting the A399–A401 galaxy cluster pair and filament system using archival data from the Planck satellite and new, targeted deep data from the Atacama Cosmology Telescope, covering 11 different frequencies over 14 maps from 30 GHz to 545 GHz. Our tSZ results are consistent with previous work using Compton-y maps. We measure the line-of-sight peculiar velocities of the cluster–filament system using the kSZ effect and find statistical uncertainties on individual cluster peculiar velocities of ≲600 km s −1 , which are competitive with current state-of-the-art measurements. Additionally, we measure the optical depth of the filament component with a signal-to-noise of 8.5σ and reveal hints of its morphology. This modular approach is well-suited for application to future instruments across a wide range of millimeter and submillimeter wavebands.

Gill, Ajay S. [National Research Council of Canada↗

Rapid data comparison technique development for N-ray/X-ray analysis

An operational N-ray/X-ray computer analysis system for nondestructive testing problems was realized by developing: (1) more efficient data transfer routines for use in existing image processing systems; (2) the capability to store and analyze multiple N-ray/X-ray images; (3) an efficient 2-D Fast Fourier Transform; and (4) transfer functions compensation capability to correct for distortions and nonlinearities of N-rays/X-rays. Applications of the technique are summarized for the following: thermal protection system tile with hydraulic fluid; thermal protection system tile with corrosion; thermal protection system tile debonding; stainless steel tubing corrosion; defective electrical devices; fast film restoration and deblur; corrosion tracking over time; reduction of source vignetting, and identification of materials (0 rings, Teflon parts, soft goods) via table look up.

Butterfield, R. L.↗

Coherent multiple tone technique for ground based SPS control

The control system achieves beam forming by adjusting the phases of the individual transmitters onboard the solar power satellite. To specify the correct amount of adjustments, the phases of the power beams from each individual transmitter arriving at the rectanna center are measured, the appropriate corrections determined, and then relayed to the satellite. The functional operation of the ground based phase control concept is summarized. The key issues examined were: measurement waveform design and selection; phase measurement pilot reference design and selection; uplink phase corrections command link format and design; and system synchronization techniques.

Chie, C. M.↗

Automatic terrain elevation mapping and registration

Optimum radar illumination geometries for stereoscopic analysis of surface topography are determined. Correlation and image processing experiments on synthetic aperture radar (SAR) data for improved information extraction are conducted. Model of the geometry of the multiple SIR-B views of the Earth are developed the sensitivity of the derived terrain altitude data to the various system parameters is established. The limits of accuracy of terrain data achievable with shuttle imaging radar (SIR-B) are derived. Algorithms for matching multiple SIR-B images to generate digital terrain maps are developed. Finally, the use of such terrain maps in geometric correction and registration of SIR-B and LANDSAT Thematic Mapper data is demonstrated.

Ramapriyan, H. K.↗

Single-event upset (SEU) in a DRAM with on-chip error correction

Results are given of SEU measurements on 256K dynamic RAMs with on-chip error correction. They are claimed to be the first ever reported. A (12/8) Hamming error-correcting code was incorporated in the layout. Physical separation of the bits in each code word was used to guard against multiple bits being disrupted in any given word. Significant reduction in observed errors is reported.

Zoutendyk, J. A.↗

Minimum length Pb/SCIN detector for efficient cosmic ray identification

A study was made of the performance of a minimal length cosmic ray shower detector that would be light enough for space flight and would provide efficient identification of positions and protons. Cosmic ray positions are mainly produced in the decay chain of: Pion yields Muon yields Positron and they provide a measure of the matter density traversed by primary protons. Present positron flux measurements are consistent with the Leaky Box and Halo models for sources of cosmic rays. Abundant protons in the space environment are a significant source of background that would wash out the positron signal. Protons and positrons produced very distictive showers of particles when they enter matter; many studies have been published on their behavior on large calorimeter detectors. The challenge is to determine the minimal material necessary (minimal calorimeter depth) for positive particles identification. The primary instrument for the investigation is the Monte Carlo code GEANT, a library of programs from CERN that can be used to model experimental geometry, detector responses and particle interaction processes. The use of the Monte Carlo approach is crucial since statistical fluctuations in shower shape are significant. Studies conducted during the 1988 summer program showed that straightforward approaches to the problem achieved 85 to 90 percent correct identification, but left a residue of 10 to 15 percent misidentified particles. This percentage improved to a few percent when multiple shower-cut criteria were applied to the data. This summer, the same study was extended to employ several physical and statistical methods of identifying response of the calorimeter and the efficiency of the optimal shower cuts to off-normal incidence particle was determined.

Snyder, H. David↗

Stray-Light Correction of the Marine Optical Buoy

In ocean-color remote sensing, approximately 90% of the flux at the sensor originates from atmospheric scattering, with the water-leaving radiance contributing the remaining 10% of the total flux. Consequently, errors in the measured top-of-the atmosphere radiance are magnified a factor of 10 in the determination of water-leaving radiance. Proper characterization of the atmosphere is thus a critical part of the analysis of ocean-color remote sensing data. It has always been necessary to calibrate the ocean-color satellite sensor vicariously, using in situ, ground-based results, independent of the status of the pre-flight radiometric calibration or the utility of on-board calibration strategies. Because the atmosphere contributes significantly to the measured flux at the instrument sensor, both the instrument and the atmospheric correction algorithm are simultaneously calibrated vicariously. The Marine Optical Buoy (MOBY), deployed in support of the Earth Observing System (EOS) since 1996, serves as the primary calibration station for a variety of ocean-color satellite instruments, including the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), the Moderate Resolution Imaging Spectroradiometer (MODIS), the Japanese Ocean Color Temperature Scanner (OCTS) , and the French Polarization and Directionality of the Earth's Reflectances (POLDER). MOBY is located off the coast of Lanai, Hawaii. The site was selected to simplify the application of the atmospheric correction algorithms. Vicarious calibration using MOBY data allows for a thorough comparison and merger of ocean-color data from these multiple sensors.

Brown, Steven W.↗

Phase Retrieval for Radio Telescope and Antenna Control

Phase-retrieval is a general term used in optics to describe the estimation of optical imperfections or "aberrations." The purpose of this innovation is to develop the application of phase retrieval to radio telescope and antenna control in the millimeter wave band. Earlier techniques do not approximate the incoherent subtraction process as a coherent propagation. This approximation reduces the noise in the data and allows a straightforward application of conventional phase retrieval techniques for radio telescope and antenna control. The application of iterative-transform phase retrieval to radio telescope and antenna control is made by approximating the incoherent subtraction process as a coherent propagation. Thus, for systems utilizing both positive and negative polarity feeds, this approximation allows both surface and alignment errors to be assessed without the use of additional hardware or laser metrology. Knowledge of the antenna surface profile allows errors to be corrected at a given surface temperature and observing angle. In addition to imperfections of the antenna surface figure, the misalignment of multiple antennas operating in unison can reduce or degrade the signal-to-noise ratio of the received or broadcast signals. This technique also has application to the alignment of antenna array configurations.

Dean, Bruce↗

The Thermal and Kinematic Sunyaev–Zeldovich Effect in Galaxy Clusters and Filaments Using Multifrequency Temperature Maps of the Cosmic Microwave Background A399–A401 Cluster Pair Case Study

We present a multifrequency and multi-instrument methodology to study the physical properties of galaxy clusters and cosmic filaments using cosmic microwave background observations. Our approach enables simultaneous measurement of both the thermal (tSZ) and kinematic Sunyaev–Zeldovich (kSZ) effects, incorporates relativistic corrections, and models astrophysical foregrounds such as thermal dust emission. We do this by jointly fitting a single physical model across multiple maps from multiple instruments at different frequencies, rather than fitting a model to a single Compton-y map. We demonstrate the success of this method by fitting the A399–A401 galaxy cluster pair and filament system using archival data from the Planck satellite and new, targeted deep data from the Atacama Cosmology Telescope, covering 11 different frequencies over 14 maps from 30 GHz to 545 GHz. Our tSZ results are consistent with previous work using Compton-y maps. We measure the line-of-sight peculiar velocities of the cluster–filament system using the kSZ effect and find statistical uncertainties on individual cluster peculiar velocities of ≲600 km s −1 , which are competitive with current state-of-the-art measurements. Additionally, we measure the optical depth of the filament component with a signal-to-noise of 8.5σ and reveal hints of its morphology. This modular approach is well-suited for application to future instruments across a wide range of millimeter and submillimeter wavebands.

Ajay S Gill↗

Beam-steering system based on a MEMS-actuated vertical-coupler array

An integrated-optics MEMS-actuated beam-steering system is disclosed, wherein the beam-steering system includes a lens and a programmable vertical coupler array having a switching network and an array of vertical couplers, where the switching network can energize of the vertical couplers such that it efficiently emits the light into free-space. The lens collimates the light received from the energized vertical coupler and directs the output beam along a propagation direction determined by the position of the energized vertical coupler within the vertical-coupler array. In some embodiments, the vertical coupler is configured to correct an aberration of the lens. In some embodiments, more than one vertical coupler can be energized to enable steering of multiple output beams. In some embodiments, the switching network is non-blocking.

42 ENGINEERING↗

Beam-steering system based on a MEMS-actuated vertical-coupler array

An integrated-optics MEMS-actuated beam-steering system is disclosed, wherein the beam-steering system includes a lens and a programmable vertical coupler array having a switching network and an array of vertical couplers, where the switching network can energize of the vertical couplers such that it efficiently emits the light into free-space. The lens collimates the light received from the energized vertical coupler and directs the output beam along a propagation direction determined by the position of the energized vertical coupler within the vertical-coupler array. In some embodiments, the vertical coupler is configured to correct an aberration of the lens. In some embodiments, more than one vertical coupler can be energized to enable steering of multiple output beams. In some embodiments, the switching network is non-blocking.

Zhang, Xiaosheng↗

Characterization of XR-RV3 GafChromic{sup ®} films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors

Purpose: To investigate the optimal use of XR-RV3 GafChromic{sup ®} films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. Methods: XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. Results: First, the performance analysis of six different scanner models has shown that scan uniformity perpendicular to the lamp motion axis and that long term stability are the main sources of scanner-related uncertainties. These could induce errors of up to 7% on the film readings unless regularly checked and corrected. Typically, scan uniformity correction matrices and reading normalization to the scanner-specific and daily background reading should be done. In addition, the analysis on multiple film batches has shown that XR-RV3 films have generally good uniformity within one batch (<1.5%), require 24 h to stabilize after the irradiation and their response is roughly independent of dose rate (<5%). However, XR-RV3 films showed large variations (up to 15%) with radiation quality both in standard laboratory and in clinical conditions. As such, and prior to conducting patient skin dose measurements, it is mandatory to choose the appropriate calibration beam quality depending on the characteristics of the x-ray systems that will be used clinically. In addition, yellow side film irradiations should be preferentially used since they showed a lower dependence on beam parameters compared to white side film irradiations. Finally, among the six different fit equations tested in this work, typically used third order polynomials and more rational and simplistic equations, of the form dose inversely proportional to pixel value, were both found to provide satisfactory results. Fitting-related uncertainty was clearly identified as a major contributor to the overall film dosimetry uncertainty with up to 40% error on the dose estimate. Conclusions: The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.

60 APPLIED LIFE SCIENCES↗

Identification of Shielding Material Configurations Using NMIS Imaging

The Nuclear Materials Identification System (NMIS) uses fast neutron tomographic imaging to nonintrusively examine the interior structure of shielded objects. The pixel values in such images represent the attenuation coefficients of the time and directionally tagged fast neutrons from a deuterium-tritium (DT) neutron generator. The reconstruction techniques use either a filtered back projection or a maximum likelihood expectation maximization algorithm. As a first test of the capabilities of these reconstruction techniques to correctly identify individual parts inside of an object, fast neutron imaging was used to identify the regions of shielding surrounding a depleted uranium casting from a library of possible parts. The shielding consisted of multiple regions of common materials such as steel, lead, aluminum, and polyethylene. First, the full object was imaged, and then each of the individual parts was imaged. Several additional parts that were not present in the original object were also imaged to form a library. The individual parts were compared to the full object, and the correct ones were identified using three different methods. These methods included a visual match, an iterative fit of each part, and a mathematical test comparing the sum of squared errors. The successful results demonstrate an initial application of matching. This suggests that it should be possible to implement more sophisticated matching techniques using automated pixel-by-pixel comparison methods in the future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗