Substrate Interference and Strain in the Second-Harmonic Generation from MoSe 2 Monolayers
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
We report the results of the numerical simulation of the output amplifier stage of a high-power laser system based on parametric amplification of femtosecond pulses in an LBO crystal under multibeam pumping. A technique is described for choosing an optimal amplifier configuration with an arbitrary number of pump beams to provide a wide spectral gain band with a minimum loss due to parametric diffraction. The results of simulating the parametric amplification, amplification efficiency, and spatial profile of amplified radiation with allowance for the interference of amplified parasitic beams are presented. A possibility of eliminating the spatial modulation of the amplified radiation intensity, which occurs when using spatial filters, is demonstrated. An increase in the number of pump beams is found to rise the amplified pulse duration, slightly (from 20 to 21 fs) for incoherent pump beams and more significantly (to 25 fs) for coherent beams. The amplification efficiency is reduced from 23% to 21% in the former case and to 11% in the latter case. (paper)
Novel chemical sensors that improve detection and quantification of CO 2 are critical to ensuring safe and cost-effective monitoring of carbon storage sites. Fiber optic (FO) based chemical sensor systems are promising field-deployable systems for real-time monitoring of CO 2 in geological formations for long-range distributed sensing. Here, a mixed-matrix composite integrated FO sensor system was developed with a purely optical readout that reliably operates as a detector for gas-phase and dissolved CO 2 . A mixed-matrix composite sensor coating consisting of plasmonic nanocrystals and hydrophobic zeolite embedded in a polymer matrix was integrated on the FO sensor. The mixed-matrix composite FO sensor showed excellent reversibility/stability in a high humidity environment and sensitivity to gas-phase CO 2 over a large concentration range. This remarkable sensing performance was enabled by using plasmonic nanocrystals to significantly enhance the sensitivity and a hydrophobic zeolite to effectively mitigate interference from water vapor. The sensor exhibited the ability to sense CO 2 in the presence of other geologically relevant gases, which is of importance for applications in geological formations. A prototype FO sensor configuration which possesses a robust sensing capability for monitoring dissolved CO 2 in natural water was demonstrated. Reproducibility was confirmed over many cycles, both in a laboratory setting and in the field. More importantly, we demonstrated on-line monitoring capabilities with a wireless telemetry system, which transferred the data from the field to a website. The combination of outstanding CO 2 sensing properties and facile coating processability makes this mixed-matrix composite FO sensor a good candidate suitable for practical carbon storage applications.
Fundamental quantum electrodynamical (QED) processes, such as spontaneous emission and electron-photon scattering, encompass phenomena that underlie much of modern science and technology. Conventionally, calculations in QED and other field theories treat incoming particles as single-momentum states, omitting the possibility that coherent superposition states, i.e., shaped wavepackets, can alter fundamental scattering processes. Here, we show that free electron waveshaping can be used to design interferences between two or more pathways in a QED process, enabling precise control over the rate of that process. As an example, we show that free electron waveshaping modifies both spatial and spectral characteristics of bremsstrahlung emission, leading for instance to enhancements in directionality and monochromaticity. The ability to tailor general QED processes opens up additional avenues of control in phenomena ranging from optical excitation (e.g., plasmon and phonon emission) in electron microscopy to free electron lasing in the quantum regime.
We report the experimental realization of a large-area and multiaxis atomtronic interferometer in an optical waveguide for rotation sensing. A large enclosed area is achieved through multiloop operation in a guided-atom interferometer using Bose-Einstein condensates. We demonstrate a three-loop interferometer with a total interrogation time of ∼ 0.4 s and an enclosed area of 8.7 mm 2 —the largest reported in a fully guided or one-dimensional setup. High-contrast interference fringes are observed for up to five Sagnac orbits in a smaller loop-area configuration. Our approach enables interleaved rotation measurements about multiple arbitrary axes within the same experimental setup. We present results for area-enclosing interferometers in both horizontal and vertical planes, demonstrating that the interferometer contrast remains comparable across orthogonal orientations of the enclosed area vectors.
One of the most important aspects of a satellite communication system design is the accurate estimation of antenna performance degradation. Pointing error, end coverage gain, peak gain degradation, etc. are the main concerns. The thermal or dynamic distortions of a reflector antenna structural system can affect the far-field antenna power distribution in a least four ways. (1) The antenna gain is reduced; (2) the main lobe of the antenna can be mispointed thus shifting the destination of the delivered power away from the desired locations; (3) the main lobe of the antenna pattern can be broadened, thus spreading the RF power over a larger area than desired; and (4) the antenna pattern sidelobes can increase, thus increasing the chances of interference among adjacent beams of multiple beam antenna system or with antenna beams of other satellites. The in-house developed NASA Lewis Research Center thermal/structural/RF analysis program was designed to accurately simulate the ACTS in-orbit thermal environment and predict the RF antenna performance. The program combines well establish computer programs (TRASYS, SINDA and NASTAN) with a dual reflector-physical optics RF analysis program. The ACTS multibeam antenna configuration is analyzed and several thermal cases are presented and compared with measurements (pre-flight).
Explore the source record for details and available documents.
We explore the electrical characteristics of TiS 3 nanowire field-effect transistor (FETs), over the wide temperature range from 3 to 350 K. These nanomaterials have a quasi-one-dimensional (1D) crystal structure and exhibit a gate-controlled metal–insulator transition (MIT) in their transfer curves. Their room-temperature mobility is ~20–30 cm 2 /(V s), 2 orders of magnitude smaller than predicted previously, a result that we explain quantitatively in terms of the influence of polar-optical phonon scattering in these materials. In the insulating state (<~220 K), the transfer curves exhibit unusual mesoscopic fluctuations and a current suppression near zero bias that is common to charge-density wave (CDW) systems. The fluctuations have a nonmonotonic temperature dependence and wash out at a temperature close to that of the bulk MIT, suggesting they may be a feature of quantum interference in the CDW state. Overall, our results demonstrate that quasi-1D TiS 3 nanostructures represent a viable candidate for FET realization and that their functionality is influenced by complex phenomena.
The method described in the present report makes it possible to obtain interferometer records with the aid of any one of the available Schlieren optics by the addition of very simple expedients, which fundamentally need not to be inferior to those obtained by other methods, such as the Mach-Zehnder interferometer, for example. The method is based on the fundamental concept of the phase-contrast process developed by Zernike, but which in principle has been enlarged to such an extent that it practically represents an independent interference method for general applications. Moreover, the method offers the possibility, in case of necessity, of superposing any apparent wedge field on the density field to be gauged. The theory is explained on a purely physical basis and illustrated and proved by experimental data. A number of typical cases are cited and some quantitative results reported.
A lock-in imaging system is configured for detecting a disturbance in air. The system includes an airplane, an interferometer, and a telescopic imaging camera. The airplane includes a fuselage and a pair of wings. The airplane is configured for flight in air. The interferometer is operatively disposed on the airplane and configured for producing an interference pattern by splitting a beam of light into two beams along two paths and recombining the two beams at a junction point in a front flight path of the airplane during flight. The telescopic imaging camera is configured for capturing an image of the beams at the junction point. The telescopic imaging camera is configured for detecting the disturbance in air in an optical path, based on an index of refraction of the image, as detected at the junction point.
Precise control over the assembly of biocompatible three-dimensional (3D) nanostructures would allow for programmed interactions within the cellular environment. Nucleic acids can be used as programmable crosslinkers to direct the assembly of quantum dots (QDs) and tuned to demonstrate different interparticle binding strategies. In this work, morphologies of self-assembled QDs are evaluated via gel electrophoresis, transmission electron microscopy, small-angle X-ray scattering, and dissipative particle dynamics simulations, with all results being in good agreement. The controlled assembly of 3D QD organizations is demonstrated in cells via the colocalized emission of multiple assembled QDs, and their immunorecognition is assessed via enzyme-linked immunosorbent assays. RNA interference inducers are also embedded into the interparticle binding strategy to be released in human cells only upon QD assembly, which is demonstrated by specific gene silencing. The programmability and intracellular activity of QD assemblies offer a strategy for nucleic acids to imbue the structure and therapeutic function into the formation of complex networks of nanostructures, while the photoluminescent properties of the material allow for optical tracking in cells in vitro.
A study into the problem of determining electromagnetic solutions at high frequencies for problems involving complex geometries, large sizes and multiple sources (e.g. antennas) has been initiated. Typical applications include the behavior of antennas (and radiators) installed on complex conducting structures (e.g. ships, aircrafts, etc..) with strong interactions between antennas, the radiation patterns, and electromagnetic signals is of great interest for electromagnetic compatibility control. This includes the overall performance evaluation and control of all on-board radiating systems, electromagnetic interference, and personnel radiation hazards. Electromagnetic computational capability exists at NASA LaRC, and many of the codes developed are based on the Moment Method (MM). However, the MM is computationally intensive, and this places a limit on the size of objects and structures that can be modeled. Here, two approaches are proposed: (i) a current-based hybrid scheme that combines the MM with Physical optics, and (ii) an Alternating Direction Implicit-Finite Difference Time Domain (ADI-FDTD) method. The essence of a hybrid technique is to split the overall scattering surface(s) into two regions: (a) a MM zone (MMZ) which can be used over any part of the given geometry, but is most essential over irregular and "non-smooth" geometries, and (b) a PO sub-region (POSR). Currents induced on the scattering and reflecting surfaces can then be computed in two ways depending on whether the region belonged to the MMZ or was part of the POSR. For the MMZ, the current calculations proceed in terms of basis functions with undetermined coefficients (as in the usual MM method), and the answer obtained by solving a system of linear equations. Over the POSR, conduction is obtained as a superposition of two contributions: (i) currents due to the incident magnetic field, and (ii) currents produced by the mutual induction from conduction within the MMZ. This effectively leads to a reduction in the size of linear equations from N to N - Npo with N being the total number of segments for the entire surface and Npo the number of segments over the POSR. The scheme would be appropriate for relatively large, flat surfaces, and at high frequencies. The ADI-FDTD scheme provides for both transient and steady state analyses. The restrictive Courant-Friedrich-Levy (CFL) condition on the time-step is removed, and so large time steps can be chosen even though the spatial grids are small. This report includes the problem definition, a detailed discussion of both the numerical techniques, and numerical implementations for simple surface geometries. Numerical solutions have been derived for a few simple situations.
A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.
We show that the supersymmetric structure (in the sense of supersymmetric quantum mechanics) appears in Helmholtz optics describing light propagation in waveguides. For the case of elliptical waveguides, with the accuracy of paraxial approximation it admits a simple physical interpretation. The supersymmetry connects light beams of different colors. The difference in light frequencies for the supersymmetric beams is determined by the transverse gradient of the refractive index. These beams have the save wavelength in the propagation direction and can form a stable interference pattern.
A method and apparatus for holographically processing optical signals in a fiber-optic sensor system. In the present invention, holographic processors are utilized in various combinations with light sources, fiber-optic transmission means, sensors and detectors to provide low cost, compact, sensitive and accurate sensor systems. By means of the holographic processors of the present invention, the aforementioned sensor systems are used to monitor such physical parameters as temperature, pressure, flow-rate, and the like, and to provide output signal indications thereof that are compatible with digital receiving stations and immune to electro-magnetic interference, hazardous atmosphere, and the inimical effects of inadvertent intensity variation due to equipment vibration and the like. In one typical embodiment, a pair of holographic processors are employed in a color multiplex-demultiplex sensor system in which a first holographic processor is employed to color multiplex a sensor signal and a second holographic processor is employed to decode the color-multiplexed signal into a binary pattern that is then transmitted onto a set of photodetectors. In each of the embodiments of the invention disclosed, a unique geometrical orientation of a hologram is utilized to minimize spurious signal interference that would otherwise hamper or totally preclude the holographic processing.
By sputtering, it is possible to make multilayered structures (layered synthetic microstructures or LSMs) with individual layers as thin as a fraction of a nanometer. These techniques have been used to make a multilayered interference mirror to reflect carbon K X rays (at a wavelength of 4.48 nm) at normal incidence. The structure consists of 76 layers of tungsten of thickness 0.765 nm with layers of carbon (thickness 1.510 nm) interspersed, deposited on a 111 line type silicon wafer substrate. This LSM was formed into a concave mirror of radius approximately 1.1 m by bending the substrate, and used in an optical set-up to form images of grids illuminated by an X-ray source. The mirror was found to have a resolution of 5 lines/mm and an efficiency, integrated over the CK band, of between 4 and 8%.
The integration of advanced materials and photonic nanostructures can lead to enhanced biodetection capabilities, crucial in clinical scenarios and point-of-care diagnostics, where simplified strategies are essential. Herein, a molecularly imprinted polymer (MIP) photonic nanostructure is demonstrated, which selectively binding to transforming growth factor-beta (TGF-β), in which the sensing transduction is enhanced by bound states in the continuum (BICs). The MIP operating as a synthetic antibody matrix and coupled with BIC resonance, enhances the optical response to TGF-β at imprinted sites, leading to an augmented detection capability, thoroughly evaluated through spectral shift and optical lever analogue readout. The validation underscores the MIP-BIC sensor capability to detect TGF-β in spiked saliva, achieving a limit of detection of 10 fM and a resolution of 0.5 pM at physiological concentrations, with a precision of two orders of magnitude above discrimination threshold in patients. The MIP tailored selectivity is highlighted by an imprinting factor of 52, showcasing the sensor resistance to interference from other analytes. The MIP-BIC sensor architecture streamlines the detection process eliminating the need for complex sandwich immunoassays and demonstrates the potential for high-precision quantification. This positions the system as a robust tool for biomarker detection, especially in real-world diagnostic scenarios.
Porous optical fibers include sensing regions filled with reagents. Optical-fiber chemical sensors (optrodes) developed to measure concentrations of ethylene in air in enclosed artificial plant-growth environments. Such measurements needed because ethylene acts as plant-growth hormone affecting growth at concentrations less than or equal to 20 parts per billion. Optrodes small, but exhibit sensitivities comparable to those of larger instruments. Operated safely in potentially explosive atmospheres and neither cause, nor susceptible to, electrical interference at suboptical frequencies.