Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

kg-mass prototype demonstrator for dual gravitational wave detector: Optomechanical excitation and cooling

The next generation of gravitational wave (gw) detectors is expected to fully enter into the quantum regime of force and displacement detection. With this aim, it is important to scale up the experiments on opto-mechanical effects from the microscopic regime to large mass systems and test the schemes that should be applied to reach the quantum regime of detection. In this work we present the experimental characterization of a prototype of massive gw detector, composed of two oscillators with a mass of the order of the kg, whose distance is read by a high finesse optical cavity. The mechanical response function is measured by exciting the oscillators through modulated radiation pressure. We demonstrate two effects crucial for the next generation of massive, cryogenic gw detectors (DUAL detectors): (a) the reduction of the contribution of 'local' susceptibility thanks to an average over a large interrogation area. Such effect is measured on the photo-thermal response thanks to the first implementation of a folded-Fabry-Perot cavity; (b) the 'backaction reduction' due to negative interference between acoustic modes. Moreover, we obtain the active cooling of an oscillation mode through radiation pressure, on the described mechanical device which is several orders of magnitude heavier than previously demonstrated radiation-pressure cooled systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-scale cascading of first-order FBG array in a highly multimode coreless fiber using femtosecond laser for distributed thermal sensing

This research focuses on the performance analysis and characterization of a fiber Bragg gratings (FBGs) array, consisting of 10 first-order FBGs inscribed by a femtosecond (FS) laser in a highly multimode coreless fiber. The study evaluates the FBG array's ability to function as a distributed thermal sensing (DTS) platform, with the coreless fiber chosen as the sensing element due to its immunity to dopant migration at high temperatures. The design of a large cascaded first-order FBG array effectively eliminates unwanted harmonic peaks across a wide spectrum range. In contrast, higher-order FBGs introduce limitations due to the overlapping of Bragg peaks with harmonics. The FBG array's performance is evaluated by measuring the reflection spectrum of each grating at different temperatures, showing a high temperature sensitivity of 15.05 pm/°C at a Bragg wavelength of 1606.3 nm, with a linear response in the temperature range of 24 - 1100 °C. The FBG array was designed for a spatial resolution of 5 mm. A mode scrambler in the sensing network is employed, which suppresses multimodal interference, characterizes FBG peak visibility, and stabilizes the interference spectrum. The stability of the FBG array is also assessed over 24 hrs at 1100 °C, and it is observed to be stable during thermal treatment. Heat treatment at 1100°C improves the signal to noise ratio of the FBG array, demonstrating the robustness and suitability of the proposed FBG array on highly multimode coreless fiber as a potential sensing platform for DTS applications in harsh environmental conditions, overcoming the issues of dopant migration presented by dopes silica optical fibers at high temperatures.

47 OTHER INSTRUMENTATION↗

Room-Temperature Optical Detection of 14 CO 2 below the Natural Abundance with Two-Color Cavity Ring-Down Spectroscopy

Radiocarbon’s natural production, radiative decay, and isotopic rarity make it a unique tool to probe carbonaceous systems in the life and earth sciences. However, the difficulty of current radiocarbon ( 14 C) detection methods limits scientific adoption. Here, two-color cavity ring-down spectroscopy detects 14 CO 2 in room-temperature samples with an accuracy of one-tenth the natural abundance in 3 min. The intracavity pump–probe measurement uses two cavity-enhanced lasers to cancel out cavity ring-down rate fluctuations and strong one-photon absorption interference (>10 000 1/s) from hot-band transitions of CO 2 isotopologues. Selective, room-temperature detection of small 14 CO 2 absorption signals (<1 1/s) reduces the technical and operational burdens for cavity-enhanced measurements of radiocarbon, which can benefit a wide range of applications like biomedical research and field-detection of combusted fossil fuels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Signal processing to reduce dark noise impact in precision timing

We introduce a technique to mitigate the effects of low frequency noise on precision timing. The example of Dark Count Noise Rate (DCR) in Silicon Photomultipliers (SiPMs) is emphasized. This technique exploits the correlation between time shifts on the leading edge of a signal and the residual slope of the baseline (due to noise) which remains after baseline subtraction. In fast timing applications (such as for Time-of-flight particle ID) the signal arrival time is typically captured on the signal leading edge. The signal risetime is often fixed by the physics of the sensor and input circuit. Then accurate pulse timing can be achieved by correcting a leading edge threshold time (depending on a slope proportional to both the Amplitude and the risetime) to a “constant fraction” time. This compensation for time walk due to amplitude fluctuations breaks down once we introduce interference from low frequency noise on the leading edge. In this paper we demonstrate that an additional measurement of the slope at threshold can be used to correct for this noise jitter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin current generation and relaxation in a quenched spin-orbit-coupled Bose-Einstein condensate

Understanding the effects of spin-orbit coupling (SOC) and many-body interactions on spin transport is important in condensed matter physics and spintronics. This topic has been intensively studied for spin carriers such as electrons but barely explored for charge-neutral bosonic quasiparticles (including their condensates), which hold promises for coherent spin transport over macroscopic distances. Here, we explore the effects of synthetic SOC (induced by optical Raman coupling) and atomic interactions on the spin transport in an atomic Bose-Einstein condensate (BEC), where the spin-dipole mode (SDM, actuated by quenching the Raman coupling) of two interacting spin components constitutes an alternating spin current. We experimentally observe that SOC significantly enhances the SDM damping while reducing the thermalization (the reduction of the condensate fraction). We also observe generation of BEC collective excitations such as shape oscillations. Our theory reveals that the SOC-modified interference, immiscibility, and interaction between the spin components can play crucial roles in spin transport.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Isostructural electronic transition in MoS 2 probed by solid-state high-harmonic generation spectroscopy

Studying materials under extreme pressure in diamond anvil cells (DACs) is key to discovering emergent states of matter, yet no method currently allows the direct measurement of the electronic structure in this environment. Solid-state high-harmonic generation (sHHG) offers a unique all-optical window into the electronic structure of materials. We demonstrate sHHG spectroscopy inside a DAC by probing 2H-MoS 2 , up to 30 GPa, revealing a pressure-induced crossover of the lowest direct bandgap from the K-point to the Γ-point. This transition manifests as a sharp minimum in harmonic intensity and a 30° rotation of the sHHG polarization anisotropy, despite the absence of a structural phase change. First-principles simulations attribute these features to interference between competing excitation pathways at distinct points in the Brillouin zone. Our results establish sHHG as a sensitive probe of electronic transitions at high pressure, enabling access to quantum phenomena that evade detection by conventional techniques.

Nebgen, Bailey R. [University of California, Berke↗

Naturally stable Sagnac–Michelson nonlinear interferometer

Interferometers measure a wide variety of dynamic processes by converting a phase change into an intensity change. Nonlinear interferometers, making use of nonlinear media in lieu of beamsplitters, promise substantial improvement in the quest to reach the ultimate sensitivity limits. Here we demonstrate a new nonlinear interferometer utilizing a single parametric amplifier for mode mixing conceptually, a nonlinear version of the conventional Michelson interferometer with its arms collapsed together. We observe up to 99.9% interference visibility and find evidence for noise reduction based on phase-sensitive gain. As a result, our configuration utilizes fewer components than previous demonstrations and requires no active stabilization, offering new capabilities for practical nonlinear interferometric-based sensors.

47 OTHER INSTRUMENTATION↗

Image mapping for multiple charge state beams using a beam induced fluorescence profile monitors

Work continues on a minimally invasive, nitrogen fluorescence gas sheet at the Facility for Rare Isotope Beams (FRIB). A low density gas sheet may be used to observe the 2D transverse beam profile of high intensity, multiple charge state beams with minimal interference. Spatially and temporally correlated profiles are of particular interest in locations where there is significant charge state spread, such as the FRIB linac folding segments. A low-density gas sheet measurement system offers advantages for gas handling in nitrogen sensitive areas, however signal intensity is significantly lower than techniques using higher density gas sheets and jets. This work discusses measurement considerations for photon distributions generated by several spatially separated interaction points and design considerations for a high-sensitivity optics system for handling the expected low signal intensity.

Accelerator Physics↗

Biophotonic rogue waves in red blood cell suspensions

Rogue waves are ubiquitous in nature, appearing in a variety of physical systems ranging from acoustics, microwave cavities, optical fibers, and resonators to plasmas, superfluids, and Bose–Einstein condensates. Unlike nonlinear solitary waves, rogue waves are extreme events that can occur even without nonlinearity by, for example, spontaneous synchronization of waves with different spatial frequencies in a linear system. Here, we report the observation of rogue-wave-like events in human red blood cell (RBC) suspensions under weak light illumination, characterized by an abnormal L-shaped probability distribution. Such biophotonic extreme events arise mostly due to the constructive interference of Mie-scattered waves from the suspended RBCs, whose biconcave shape and mutable orientation give rise to a time-dependent random phase modulation to an incident laser beam. We numerically simulate the beam propagation through the colloidal suspensions with added disorder in both spatial and temporal domains to mimic random scattering due to Brownian motion. In addition, at high power levels, nonlinear beam self-focusing is also observed, leading to a dual-exponential probability distribution associated with the formation of multiple soliton-like spots. Such rogue wave events should also exist in environments with cells of other species such as swimming bacteria, and understanding of their underlying physics may lead to unexpected biophotonic applications.

59 BASIC BIOLOGICAL SCIENCES↗

Summary of Disposable Debris Shields (DDS) Analysis for Development of Solid Debris Collection at NIF

Collection of solid debris from the National Ignition Facility (NIF) is being developed both as a diagnostic tool and as a means for measuring nuclear reaction cross sections relevant to the Stockpile Stewardship Program and nuclear astrophysics. The concept is straightforward; following a NIF shot, the debris that is produced as a result of the capsule and hohlraum explosion would be collected and subsequently extracted from the chamber. The number of nuclear activations that occurred in the capsule would then be measured through a combination of radiation detection and radiochemical processing followed by mass spectrometry. Development of the catcher is challenging due to the complex environment of the NIF target chamber. The collector surface is first exposed to a large photon flux, followed by the debris wind that is produced. The material used in the catcher must be mechanically strong in order to withstand the large amount of energy it is exposed to, as well as be chemically compatible with the form and composition of the debris. In addition, the location of the catcher is equally important. If it is positioned too close to the center of the target chamber, it will be significantly ablated, which could interfere with the ability of the debris to reach the surface and stick. If it is too far away, the fraction of the debris cloud collected will be too small to result in a statistically significant measurement. Material, geometric configuration, and location must all be tested in order to design the optimal debris collection system for NIF. One of the first ideas regarding solid debris collection at NIF was to use the disposable debris shields (DDS), which are fielded over the final optics assemblies (FOA) 7 m away from the center of the target chamber. The DDS are meant to be replaced after a certain number of shots, and if the shields could be subsequently analyzed after removal, it would serve as a mechanism for fielding a relatively large collection area through the use of a part meant to be replaced regularly. The solid angle covered by one of the shields is roughly 10 -4 of 4π. If several shields were analyzed at once, it would increase the solid angle of the collection area accordingly. The glass shields consist of ammonia hardened silica with a sol gel coating and kapton tape around the edge. The square sheets are 14-inch on each side. The original shields were 1 mm thick, but it was determined that a thicker shield (3.3 mm) was more effective in preventing debris from reaching the FOA. The Solid Radchem group received two sets of DDS as part of our evaluation of the potential use of the DDS as solid debris collectors. The first set consisted of two 3.3 mm shields, one each from the top and bottom of the chamber (the '3mm set'). The second set consisted of four 1mm shields, one from the top of the chamber and the other three from the bottom (the 'IFSA set'). For each set, the shields were cut into smaller subsamples, which were then imaged using scanning electron microscopy (SEM) followed by chemical leaching and mass spectrometry. The purpose was to evaluate both the quantity and identity of the debris that was present on the DDS surfaces, and to determine if any of the capsule debris was reaching the chamber walls. In addition, potential enhancement due to gravity in the chamber was evaluated by directly comparing shields fielded in the top and bottom of the chamber. Based on the results, the use of the DDS as debris collectors would be evaluated. The results from both sets were presented to the DDS Working Group. The slides are attached to this document. The 3mm set results are presented first, followed by the results from the IFSA set. In both cases it was determined that a small fraction of the overall debris field was collected on the DDS. This means that the debris that is formed during a NIF shot is condensing out of the plasma and depositing on surfaces closer to the target chamber center, or else it is simply falling to the bottom of the chamber. In either case, it was determined that using the DDS, or fielding a debris collector at the chamber wall, was not feasible for solid debris collection at NIF due to the small amount of debris that had been collected. In addition, since the glass shields suffered quite a bit of damage from particles impacting the surface, glass was ruled out as a collection medium.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Influence of Ag thickness on structural, optical, and electrical properties of ZnS/Ag/ZnS multilayers prepared by ion beam assisted deposition

The structural, optical, and electrical characteristics of zinc sulfide (ZnS)/Ag/ZnS (ZAZ) multilayer films prepared by ion beam assisted deposition on k9 glass have been investigated as a function of Ag layer thickness. The characteristics of ZAZ multilayer are significantly improved up insertion of optimal Ag thickness between ZnS layers. The results show that due to bombardment of Ar ion beam, distinct Ag islands evolve into continuous Ag films at a thin Ag thickness of about 4 nm. The thinner Ag film as a thickness of 2 nm leads to high sheet resistance and low transmittance for the interface scattering induced by the Ag islands or noncontinuous films; and when the Ag thickness is over 4 nm, the ZAZ multilayer exhibits a remarkably reduced sheet resistance between 7-80 {Omega}/sq for the increase in carrier concentration and mobility of Ag layer, and a high transmittance over 90% for the interference phenomena of multilayers and low absorption and surface scattering of Ag layer. The ZAZ multilayer with 14 nm Ag film has a figure of merit up to 6.32x10{sup -2} {Omega}{sup -1}, an average transmittance over 92% and a sheet resistance of 7.1 {Omega}/sq. The results suggest that ZAZ film has better optoelectrical properties than conditional indium tin oxide single layer.

36 MATERIALS SCIENCE↗

Dynamics of photorefractive self-pumped phase-conjugate mirrors with a linear resonator

The phase-conjugation dynamics in a self-pumped phase-conjugate mirror (SP PCM) based on a BaTiO{sub 3} photorefractive crystal (PRC) with a linear resonator is simulated numerically. It is shown that a phased array of dynamic holograms is formed in such a SP PCM under optimal conditions, and the interference of the waves scattered by this array provides the very high stationary phase-conjugation efficiency (the nonlinear reflection coefficient and overlap integral exceeding 80% and 95%, respectively). It is found that the development of instabilities is caused both by the violation of phase relations in this array and the formation of additional dynamic holograms in the PRC in the geometry typical of a SP PCM with a semi-linear resonator and by the self-bending effect typical of PRCs. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultracold Bose gases in time-dependent one-dimensional superlattices: Response and quasimomentum structure

The response of ultracold atomic Bose gases in time-dependent optical lattices is discussed based on direct simulations of the time-evolution of the many-body state in the framework of the Bose-Hubbard model. We focus on small-amplitude modulations of the lattice potential as implemented in several recent experiments and study different observables in the region of the first resonance in the Mott-insulator phase. In addition to the energy transfer we investigate the quasimomentum structure of the system which is accessible via the matter-wave interference pattern after a prompt release. We identify characteristic correlations between the excitation frequency and the quasimomentum distribution and study their structure in the presence of a superlattice potential.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correcting magnetic resonance k-space data for in-plane motion using an optical position tracking system

Purpose: Motion is a major confound of image quality in MRI. A method of retrospectively correcting the effects of rotations and translations on the acquired k-space data is presented. Methods: In two phantom experiments of well-controlled translation and rotation, two MRI-compatible infrared cameras recorded motion data that were used subsequently to correct the position and phase of recorded k-space samples. Motion data can be acquired with a temporal resolution of 60 Hz and spatial accuracy of 0.1 mm for translations and 0.2 deg. for rotations. Results: Significant improvements of image quality are demonstrated. Conclusions: The key advantages of the technique are that it is easy to implement, does not interfere with or complicate MR data acquisition, and is capable of correcting distortions within a single slice. Therefore, the technique has the potential to improve upon approaches that rely on the registration or realignment of successive imaging slices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlocal polarization interferometer for entanglement detection

We report a nonlocal interferometer capable of detecting entanglement and identifying Bell states statistically. This is possible due to the interferometer's unique correlation dependence on the antidiagonal elements of the density matrix, which have distinct bounds for separable states and unique values for the four Bell states. The interferometer consists of two spatially separated balanced Mach-Zehnder or Sagnac interferometers that share a polarization-entangled source. Correlations between these interferometers exhibit nonlocal interference, while single-photon interference is suppressed. This interferometer also allows for a unique version of the Clauser-Horne-Shimony-Holt Bell test where the local reality is the photon polarization. In conclusion, we present the relevant theory and experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of the irising effect of a slow-gating intensified charge-coupled device on laser-induced incandescence measurements of soot

Intensified charge-coupled devices (ICCDs) are used extensively in many scientific and engineering environments to image weak or temporally short optical events. To optimize the quantum efficiency of light collection, many of these devices are chosen to have characteristic intensifier gate times that are relatively slow, on the order of tens of nanoseconds. For many measurements associated with nanosecond laser sources, such as scattering-based diagnostics and most laser-induced fluorescence applications, the signals rise and decay sufficiently fast during and after the laser pulse that the intensifier gate may be set to close after the cessation of the signal and still effectively reject interferences associated with longer time scales. However, the relatively long time scale and complex temporal response of laser-induced incandescence (LII) of nanometer-sized particles (such as soot) offer a difficult challenge to the use of slow-gating ICCDs for quantitative measurements. In this paper, ultraviolet Rayleigh scattering imaging is used to quantify the irising effect of a slow-gating scientific ICCD camera, and an analysis is conducted of LII image data collected with this camera as a function of intensifier gate width. The results demonstrate that relatively prompt LII detection, generally desirable to minimize the influences of particle size and local gas pressure and temperature on measurements of the soot volume fraction, is strongly influenced by the irising effect of slow-gating ICCDs.

36 MATERIALS SCIENCE↗

Evaluation of the irising effect of a slow-gating ICCD on laser-induced incandescence measurements of soot.

Intensified charge-coupled devices (ICCDs) are used extensively in many scientific and engineering environments to image weak or temporally short optical events. To optimize the quantum efficiency of light collection, many of these devices are chosen to have characteristic intensifier gate times that are relatively slow, on the order of tens of nanoseconds. For many measurements associated with nanosecond laser sources, such as scattering-based diagnostics and most laser-induced fluorescence applications, the signals rise and decay sufficiently fast during and after the laser pulse that the intensifier gate may be set to close after the cessation of the signal and still effectively reject interferences associated with longer time scales. However, the relatively long time scale and complex temporal response of laser-induced incandescence (LII) of nanometer-sized particles (such as soot) offer a difficult challenge to the use of slow-gating ICCDs for quantitative measurements. In this paper, ultraviolet Rayleigh scattering imaging is used to quantify the irising effect of a slow-gating scientific ICCD camera, and an analysis is conducted of LII image data collected with this camera as a function of intensifier gate width. The results demonstrate that relatively prompt LII detection, generally desirable to minimize the influences of particle size and local gas pressure and temperature on measurements of the soot volume fraction, is strongly influenced by the irising effect of slow-gating ICCDs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vortex dynamics and Hall conductivity of hard-core bosons

Magnetotransport of hard-core bosons is studied using an XXZ quantum spin model representation, appropriately gauged on the torus to allow for an external magnetic field. We find strong lattice effects near half filling. An effective quantum mechanical description of the vortex degrees of freedom is derived. Using semiclassical and numerical analysis we compute the vortex-hopping energy t{sub V}, which at half filling is close to magnitude of the boson hopping energy. The critical quantum melting density of the vortex lattice is estimated at 6.5x10{sup -3} vortices per unit cell. The Hall conductance is computed from the Chern numbers of the low-energy eigenstates. At zero temperature, it reverses sign abruptly at half filling. At precisely half filling, all eigenstates are doubly degenerate for any odd number of flux quanta. We prove the exact degeneracies on the torus by constructing an SU(2) algebra of point-group symmetries, associated with the center of vorticity. This result is interpreted as if each vortex carries an internal spin-half degree of freedom, which can manifest itself as a charge density modulation in its core. Our findings suggest interesting experimental implications for vortex motion of cold atoms in optical lattices and magnet transport of short coherence length superconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗