Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Study to design and develop remote manipulator system

Human performance measurement techniques for remote manipulation tasks and remote sensing techniques for manipulators are described for common manipulation tasks, performance is monitored by means of an on-line computer capable of measuring the joint angles of both master and slave arms as a function of time. The computer programs allow measurements of the operator's strategy and physical quantities such as task time and power consumed. The results are printed out after a test run to compare different experimental conditions. For tracking tasks, we describe a method of displaying errors in three dimensions and measuring the end-effector position in three dimensions.

Hill, J. W.↗

JIRIAF: JLAB Integrated Research Infrastructure Acros Facilities

The JIRIAF project aims to combine geographically diverse computing facilities into an integrated science infrastructure. This project starts by dynamically evaluating temporarily unallocated or idled compute resources from multiple providers. These resources are integrated to handle additional workloads without affecting local running jobs. This paper describes our approach to launch best-effort batch tasks which exploit these underutilized resources. Our system measures the real-time behavior of jobs running on a machine and learns to distinguish typical performance from outliers. Unsupervised ML techniques are used to analyze hardware-level performance measures, followed by a real-time cross-correlation analysis to determine which applications cause performance degradation. We then ameliorate bad behavior by throttling these processes. We demonstrate that problematic performance interference can be detected and acted on, which makes it possible to continue to share resources between applications and simultaneously maintain high utilization levels in a computing cluster. We relocate the CLAS12 data processing workflow to a remote data center for a case study, preventing file migration and temporal data persistency.

Lawrence, David↗

State-conditional coherent charge qubit oscillations in a Si/SiGe quadruple quantum dot

Universal quantum computation requires high-fidelity single-qubit rotations and controlled two-qubit gates. Along with high-fidelity single-qubit gates, strong efforts have been made in developing robust two-qubit logic gates in electrically gated quantum dot systems to realise a compact and nanofabrication-compatible architecture. Here we perform measurements of state-conditional coherent oscillations of a charge qubit. Using a quadruple quantum dot formed in a Si/SiGe heterostructure, we show the first demonstration of coherent two-axis control of a double quantum dot charge qubit in undoped Si/SiGe, performing Larmor and Ramsey oscillation measurements. We extract the strength of the capacitive coupling between a pair of double quantum dots by measuring the detuning energy shift (≈75 μeV) of one double dot depending on the excess charge configuration of the other double dot. Finally, we further demonstrate that the strong capacitive coupling allows fast, state-conditional Landau–Zener–Stückelberg oscillations with a conditional π phase flip time of about 80 ps, showing a promising pathway towards multi-qubit entanglement and control in semiconductor quantum dots.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fine energy resolution survey of the sky with a germanium gamma-ray spectrometer

A fine-energy-resolution survey (38 to 2700 keV) of the sky has been performed from a spinning polar-orbiting satellite with a cooled germanium spectrometer. The measurements, performed with a fast time resolution (32 ms), permit one to analyze the energy spectra from repeated noon-midnight orbits in selected portions of the local daytime or nighttime sky. During the initial period of the experiment, the sky was surveyed in two broad intervals spanning the galactic plane at longitudes of approximately 255 to 328 deg and 99 to 168 deg, respectively. In the former interval a significant increase in counting rate was observed when the spectrometer viewed the galactic plane. Locally generated backgrounds were removed from the galactic-plane spectrum by subtracting, on a spin-for-spin basis, the contribution measured at a viewing direction with a comparable declination north of the celestial equator. The net spectra from the galactic plane have been examined for evidence of gamma-ray lines. The possible presence of lines near 1121 and 1369 keV emitted from the galactic plane over the galactic longitudinal interval approximately 255 deg to approximately 328 deg is suggested by the data, but better statistics are needed to establish their existence firmly. Comparisons are made with previously reported extraterrestrial lines with assumed normalizations made for the different viewing directions in the two experiments.

Imhof, W. L.↗

ICESat-2 Precision Orbit Determination

The ICESat-2 Precision Orbit Determination (POD) system computes the precise position of the laser altimeter instrument in inertial space, a measurement necessary for accurate geolocation of individual photon surface returns. ICESat-2 POD solutions are generated by the reduction of Global Positioning System (GPS) double-difference carrier phase observable residuals with NASA Goddard Space Flight Center's GEODYN software. Independent satellite laser ranging (SLR) measurements are withheld from the POD solutions and used as an independent arbiter of POD performance. Measurement model updates in the form of estimated GPS antenna phase center and satellite laser ranging retro-reflector tracking point offset vectors as well as a GPS antenna phase center variation map have led to significant improvement in POD performance. GPS residual analysis and orbit precision analysis show no significant anomalous temporal or geographic POD performance issues. The independent SLR residual analysis indicates that POD solutions have achieved a radial orbit accuracy just below 1.5 cm, thus exceeding the mission radial orbit accuracy requirement of 3.0 cm by more than a factor of 2. Future POD processing updates have been identified and will lead to even further improvements in POD performance.

T. C. Thomas↗

How Useful are Conventional I–Vs for Performance Calibration of Single- and Two-Junction Perovskite Solar Cells? A Statistical Analysis of Performance Data on ≈200 Cells from 30 Global Sources

As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well-documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady-state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady-state measurement methods take tens of minutes to complete, as opposed to conventional "fast" current-voltage (I-V) measurements usually lasting a few seconds. Fast I-Vs arise from a snapshot, almost always not a steady-state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I-V and with a steady-state method? Results compiled from approximately 200 perovskite PV cells, including single junction, and two-terminal perovskite-perovskite and perovskite-Si tandems, show that fast I-Vs can provide a useful measure of the open-circuit voltage of the devices, while the short-circuit current and the overall efficiency can be widely misestimated. Here, the implications of these findings on performance testing protocols are discussed and possible options for fast and accurate testing of perovskite PV are proposed.

14 SOLAR ENERGY↗

Statistical Performance Analysis on Approximately 320 Perovskite Single- and Two-Junction Solar Cells and Modules from >30 Global Sources

As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady-state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady-state measurement methods take tens of minutes to complete, as opposed to conventional "fast" current-voltage (I-V) measurements usually lasting a few seconds. Fast I-Vs arise from a snapshot, almost always not a steady-state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I-V and with a steady-state method? We compile results from ca. 320 perovskite PV cells and modules, including single junction, and two-terminal perovskite-perovskite and perovskite-Si tandems, and show that fast I-Vs can provide a useful measure of the open-circuit voltage of the devices, while the short-circuit current and the overall efficiency can be widely misestimated. We discuss implications of these findings on performance testing protocols and propose possible options for fast and accurate testing of perovskite PV.

asymptotic↗

The Primary Flight Display and Its Pathway Guidance: Workload, Performance, and Situation Awareness

In two experiments carried out in a high fidelity general aviation flight simulator, 42 instrument rated pilots flew a pathway-in-the-sky (tunnel) display through a series of multi-leg curved stepdown approaches through mountainous terrain. Both experiments examined how properties of the tunnel influenced flight path tracking performance, traffic awareness, terrain awareness and workload (assessed both by subjective and secondary task performance measures). Experiment 1, flown in simulated VMC, compared high and low intensity tunnels, with a less cluttered follow-me-airplane (FMA). The results revealed that both tunnels supported better flight path tracking than the FMA, because of the availability of more preview information. Increasing tunnel intensity, while reducing subjective workload, had no benefit on tracking, and degraded traffic detection performance. In Experiment 2, flown mostly in IMC, the low intensity tunnel was flown with a large (10 inch x 8 inch) and small (8 inch x 6.5 inch) display, representing a geometric field of view (GFOV) of either 30 degrees or 60 degrees. Most measures of flight path tracking performance favored the smaller display, and particularly the 60 degree GFOV, which presented a smaller appearing tunnel, and a wider range of terrain depiction. The larger GFOV also supported better terrain awareness, and yielded a lower secondary task assessment of workload. In both experiments, the final landing approach was terminated by a runway obstruction, and the tunnel guided pilots on a missed approach. In nearly all cases, pilots failed to notice an air hazard that lay in the missed approach path, but was only depicted in the outside view.

Wickens, Christopher D.↗

Predictive analytics of selections of russet potatoes

We explore the application of machine learning algorithms specifically to enhance the selection process of Russet potato (Solanum tuberosum L.) clones in breeding trials by predicting their suitability for advancement. This study addresses the challenge of efficiently identifying high-yield, disease-resistant, and climate-resilient potato varieties that meet processing industry standards. Leveraging manually collected data from trials in the state of Oregon, we investigate the potential of a wide variety of state-of-the-art binary classification models. The dataset includes 1086 clones, with data on 38 attributes recorded for each clone, focusing on yield, size, appearance, and frying characteristics, with several control varieties planted consistently across four Oregon regions from 2013 to 2021. We conduct a comprehensive analysis of the dataset that includes preprocessing, feature engineering, and imputation to address missing values. We focus on several key metrics such as accuracy, F1-score, and Matthews correlation coefficient (MCC) for model evaluation. The top-performing models, namely a feedforward neural network classifier (Neural Net), a histogram-based gradient boosting classifier (HGBC), and a support vector machine classifier (SVM), demonstrate consistent and significant results. To further validate our findings, we conducted a simulation study using the aims, data-generating mechanisms, estimands, methods, and performance measures (ADEMP) framework, simulating different data-generating scenarios to assess model robustness and performance through true positive, true negative, false positive, and false negative distributions, area under the receiver operating characteristic curve (AUC-ROC) and MCC. The simulation results highlight that non-linear models like SVM and HGBC consistently show higher AUC-ROC and MCC than logistic regression, thus outperforming the traditional linear model across various distributions, and emphasizing the importance of model selection and tuning in agricultural trials. Variable selection further enhances model performance and identifies influential features in predicting trial outcomes. The findings emphasize the potential of machine learning in streamlining the selection process for potato varieties, offering benefits such as increased efficiency, substantial cost savings, and judicious resource utilization. Our study contributes insights into precision agriculture and showcases the relevance of advanced technologies for informed decision-making in breeding programs.

60 APPLIED LIFE SCIENCES↗

Carbon/lambda-MnO{sub 2} composites for supercapacitor electrodes

In the present work a composite of carbon with lambda-MnO{sub 2} have been synthesized by a simple two-step route. In the first step, to obtain LiMn{sub 2}O{sub 4}/carbon material, mesoporous activated carbon was impregnated with the solution of precursor metal salts and heated subsequently. As-prepared materials were acid treated which resulted in the formation of lambda-MnO{sub 2}/carbon. Physical properties, structure and specific surface area of electrode materials were studied by TEM, X-ray diffraction and nitrogen sorption measurements. Voltammetry cycling, galvanostatic charge/discharge and impedance spectroscopy measurements performed in two- and three-electrode cells have been applied in order to measure electrochemical parameters. TEM images confirmed well dispersed lambda-MnO{sub 2} particles on the surface of carbon material. The carbon in the composite plays an important role as the surface area enhancing component and a support of pseudocapacitive material. Furthermore, the through-connected porosity serves as a continuous pathway for electrolyte transport. A synergetic effect of the porous carbon framework and of the redox properties of the lambda-MnO{sub 2} is at the origin of improvement of specific capacitance values which has been observed for composites after delithiation. - Comparison of capacitance characteristics for initial carbon and synthesised composites for CB in 1 mol L{sup -1} Na{sub 2}SO{sub 4} solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integration of an Atomic Force Microscope in a Beamline Sample Environment

We developed and optimised an optics-free Atomic Force Microscope (AFM) that can be directly installed on most of the synchrotron radiation end-stations. The combination of Scanning Probe Microscopies with X-ray microbeams adds new possibilities to the variety of synchrotron radiation techniques. The instrument can be used for atomic force imaging of the investigated sample or to locally measure the X-ray absorption or diffraction, or it can also be used to mechanically interact with the sample while simultaneously taking spectroscopy or diffraction measurements. The local character of these measurements is intrinsically linked with the use of the Atomic Force Microscope tip. It is the sharpness of the tip that gives the opportunity to measure the photons flux impinging on it giving beam position monitor features, or allows to locally measure the absorption coefficient or the shape of the diffraction pattern. As an example of the possibilities opened by the instrument we will show diffraction measurements performed on a Ge/Si island while being indented with the AFM tip providing local measure of the Young coefficient. Three ESRF beamlines are going to be equipped with this new instrument.

43 PARTICLE ACCELERATORS↗

Accurate measurements and temperature dependence of the water vapor self-continuum absorption in the 2.1 μm atmospheric window

In spite of its importance for the evaluation of the Earth radiative budget, thus for climate change, very few measurements of the water vapor continuum are available in the near infrared atmospheric windows especially at temperature conditions relevant for our atmosphere. In addition, as a result of the difficulty to measure weak broadband absorption signals, the few available measurements show large disagreements. We report here accurate measurements of the water vapor self-continuum absorption in the 2.1 μm window by Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) for two spectral points located at the low energy edge and at the center of the 2.1 μm transparency window, at 4302 and 4723 cm{sup −1}, respectively. Self-continuum cross sections, C{sub S}, were retrieved with a few % relative uncertainty, from the quadratic dependence of the spectrum base line level measured as a function of water vapor pressure, between 0 and 16 Torr. At 296 K, the C{sub S} value at 4302 cm{sup −1} is found 40% higher than predicted by the MT-CKD V2.5 model, while at 4723 cm{sup −1}, our value is 5 times larger than the MT-CKD value. On the other hand, these OF-CEAS C{sub S} values are significantly smaller than recent measurements by Fourier transform spectroscopy at room temperature. The temperature dependence of the self-continuum cross sections was also investigated for temperatures between 296 K and 323 K (23-50 °C). The derived temperature variation is found to be similar to that derived from previous Fourier transform spectrometer (FTS) measurements performed at higher temperatures, between 350 K and 472 K. The whole set of measurements spanning the 296-472 K temperature range follows a simple exponential law in 1/T with a slope close to the dissociation energy of the water dimer, D{sub 0} ≈ 1100 cm{sup −1}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Near interface traps in SiO{sub 2}/4H-SiC metal-oxide-semiconductor field effect transistors monitored by temperature dependent gate current transient measurements

This letter reports on the impact of gate oxide trapping states on the conduction mechanisms in SiO{sub 2}/4H-SiC metal-oxide-semiconductor field effect transistors (MOSFETs). The phenomena were studied by gate current transient measurements, performed on n-channel MOSFETs operated in “gate-controlled-diode” configuration. The measurements revealed an anomalous non-steady conduction under negative bias (V{sub G} > |20 V|) through the SiO{sub 2}/4H-SiC interface. The phenomenon was explained by the coexistence of a electron variable range hopping and a hole Fowler-Nordheim (FN) tunnelling. A semi-empirical modified FN model with a time-depended electric field is used to estimate the near interface traps in the gate oxide (N{sub trap} ∼ 2 × 10{sup 11} cm{sup −2}).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

{beta} decay of the proton-rich nucleus {sup 24}Si and its mirror asymmetry

{beta}-decay spectroscopy of the proton-rich nucleus {sup 24}Si was performed. The decay scheme was reconstructed from results of delayed {gamma}-ray and proton measurements. We observed two {beta} branches to bound states in {sup 24}Al for the first time. The branching ratios were determined to be 31(4)% and 23.9(15)% for the 1{sub 1}{sup +} state at 0.426 MeV and the state at 1.090 MeV, respectively. The observation of an allowed transition to the 1.090-MeV state enabled us to firmly determine its spin-parity as 1{sup +}. In the proton measurements performed with the {delta}E-E method, we observed a new unbound level at 6.735 MeV. The branching ratios to three unbound states, including the new level, were also determined for the first time. Based on the decay scheme, the B(GT) values of {sup 24}Si were deduced. The B(GT) values were smaller than those of the mirror nucleus {sup 24}Ne by 22% and 10% for the 1{sub 1}{sup +} and 1{sub 2}{sup +} states, respectively. The mirror asymmetries of B(GT), observed in both the 1{sub 1}{sup +} and the 1{sub 2}{sup +} states, indicate changes in configuration in the wave function associated with the Thomas-Ehrman shift. To clarify the mechanism of this asymmetry, a comparison with shell-model calculations is also discussed. The calculations attribute the changes in configuration to the lowering of the 1s{sub 1/2} orbital.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of the Gafchromic{sup Registered-Sign} EBT2 film for the dosimetry of radiosurgical beams

Purpose: Radiosurgery uses small fields and high-radiation doses to treat intra- and extracranial lesions in a single session. The lack of a lateral electronic equilibrium and the presence of high-dose gradients in these fields are challenges for adequate measurements. The availability of radiation detectors with the high spatial resolution required is restricted to only a few. Stereotactic diodes and EBT radiochromic films have been demonstrated to be good detectors for small-beam dosimetry. Because the stereotactic diode is the standard measurement for the dosimetry of radiosurgical beams, the goal of this work was to perform measurements with the radiochromic film Gafchromic{sup Registered-Sign} EBT2 and compare its results with a stereotactic diode. Methods: Total scatter factors, tissue maximum, and off-axis ratios from a 6 MV small photon beams were measured using EBT2 radiochromic film in a water phantom. The film-measured data were evaluated by comparing it with the data measured with a stereotactic field diode (IBA-Dosimetry). Results: The film and diode measurements had excellent agreement. The differences between the detectors were less than or equal to 2.0% for the tissue maximum and the off-axis ratios. However, for the total scatter factors, there were significant differences, up to 4.9% (relative to the reference field), for field sizes less than 1.0 cm. Conclusions: This work found that the Gafchromic{sup Registered-Sign} EBT2 film is adequate for small photon beam measurements, particularly for tissue maximum and off-axis ratios. However, careful attention must be taken when measuring output factors of small beams below 1.0 cm due to the film's energy dependence. The measurement differences may be attributable to the film's active layer composition because EBT2 incorporates higher Z elements (i.e., bromide and potassium), hence revealing a potential energy dependence for the dosimetry of small photon beams.

60 APPLIED LIFE SCIENCES↗

Patient-specific quantification of image quality: An automated method for measuring spatial resolution in clinical CT images

Purpose: To develop and validate an automated technique for evaluating the spatial resolution characteristics of clinical computed tomography (CT) images. Methods: Twenty one chest and abdominopelvic clinical CT datasets were examined in this study. An algorithm was developed to extract a CT resolution index (RI) analogous to the modulation transfer function from clinical CT images by measuring the edge-spread function (ESF) across the patient’s skin. A polygon mesh of the air-skin boundary was created. The faces of the mesh were then used to measure the ESF across the air-skin interface. The ESF was differentiated to obtain the line-spread function (LSF), and the LSF was Fourier transformed to obtain the RI. The algorithm’s ability to detect the radial dependence of the RI was investigated. RIs measured with the proposed method were compared with a conventional phantom-based method across two reconstruction algorithms (FBP and iterative) using the spatial frequency at 50% RI, f{sub 50}, as the metric for comparison. Three reconstruction kernels were investigated for each reconstruction algorithm. Finally, an observer study was conducted to determine if observers could visually perceive the differences in the measured blurriness of images reconstructed with a given reconstruction method. Results: RI measurements performed with the proposed technique exhibited the expected dependencies on the image reconstruction. The measured f{sub 50} values increased with harder kernels for both FBP and iterative reconstruction. Furthermore, the proposed algorithm was able to detect the radial dependence of the RI. Patient-specific measurements of the RI were comparable to the phantom-based technique, but the patient data exhibited a large spread in the measured f{sub 50}, indicating that some datasets were blurrier than others even when the projection data were reconstructed with the same reconstruction algorithm and kernel. Results from the observer study substantiated this finding. Conclusions: Clinically informed, patient-specific spatial resolution can be measured from clinical datasets. The method is sufficiently sensitive to reflect changes in spatial resolution due to different reconstruction parameters. The method can be applied to automatically assess the spatial resolution of patient images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗

Measurements of higher-order cumulants of multiplicity and net-electric charge distributions in inelastic proton-proton interactions by NA61/SHINE

This paper presents the energy dependence of multiplicity and net-electric charge fluctuations in p+p interactions at beam momenta 20, 31, 40, 80, and 158 \(\text{ Ge }\hspace{-1.00006pt}\text{ V }\!/\!c\). Results are corrected for the experimental biases and quantified with the use of cumulants and factorial cumulants. Cumulant ratios are an essential tool in the search for the critical point of strongly interacting matter in heavy ion collisions. Measurements performed in p+p interactions provide a vital baseline estimation in these studies. The measured signals are compared with the string hadronic models Epos1.99 and FTFP-BERT.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗