Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Feasibility Study of Economics and Performance of Biopower at the Chanute Air Force Base in Rantoul, Illinois. A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Former Chanute Air Force Base site in Rantoul, Illinois, for a feasibility study of renewable energy production. The National Renewable Energy Laboratory (NREL) was contacted to provide technical assistance for this project. The purpose of this study was to assess the site for a possible biopower system installation and estimate the cost, performance, and impacts of different biopower options.

09 BIOMASS FUELS↗

Enantioselective Kinetic Resolution/Desymmetrization of Para</em-Quinols: A Case Study in Boronic-Acid-Directed Phosphoric Acid Catalysis

A chiral phosphoric acid-catalyzed kinetic resolution and desymmetrization of para-quinols operating via oxa-Michael addition was developed and subsequently subjected to mechanistic study. Good to excellent s-factors/enantioselectivities were obtained over a broad range of substrates. Kinetic studies were performed, and DFT studies favor a hydrogen bonding activation mode. The mechanistic studies provide insights to previously reported chiral anion phase transfer reactions involving chiral phosphate catalysts in combination with boronic acids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study on Microwave Performance of Low-Temperature Sintered, Ba(CoTi){sub 1.5}Fe{sub 9}O{sub 19} Ferrite for Application at UHF Frequency

M-type barium ferrite, Ba(CoTi){sub 1.5}Fe{sub 9}O{sub 19}, was synthesized via the solid-state reaction method. BBSZ, i.e., B{sub 2}O{sub 3} −Bi{sub 2}O{sub 3} −SiO{sub 2} −ZnO, was added to adjust the sintering temperature to values lower than that of silver (i.e., ∼961 °C). The phase formation characteristics, microstructure, magnetic, and microwave properties were characterized by x-ray diffraction, scanning electron microscope, vibrating sample magnetometer, and impedance analyzer, respectively. The results show that densification of samples were enhanced by increasing the amount of BBSZ with corresponding gains realized in magnetic properties. Such enhanced properties in Ba(CoTi){sub 1.5}Fe{sub 9}O{sub 19} are attributed to the low-melting point experienced as the result of BBSZ glass additives which gave rise to the stabilization of a liquid phase during sintering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The joint influence of albedo and insulation on roof performance: An observational study

We focus on understanding the temperature and heat flux fields in building roofs, and how they are modulated by the interacting influences of albedo and insulation at annual, seasonal and diurnal scales. High precision heat flux plates and thermocouples were installed over multiple rooftops of varying insulation thickness and albedo in the Northeastern United States to monitor the temperature and the heat flux into and out of the roof structures for a whole year. This analysis shows that while membrane reflectivity (albedo) plays a dominant role in reducing the heat conducted inward through the roof structures during the warmer months, insulation thickness becomes the main roof attribute in preventing heat loss from the buildings during colder months. On a diurnal scale, the thermal state of the white roof structures fluctuated little compared to black roof structures; membrane temperature over white roofs ranged between 10 °C and 45 °C during summer months compared to black membranes that ranged between 10 °C and 80 °C. Insulation thickness, apart from reducing the heat conducted through the roof structure, also delayed the transfer of heat, owing to the thermal inertia of the insulation layer. Furthermore, this has important implications for determining the peak heating and cooling times.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Volatile particles measured by vapor-particle separator

Vapor-Particle Separator (VPS) is a new technology developed for characterization of the volatile fraction of particulate matter in a combustion aerosol population. VPS incorporates a novel metallic membrane and operates in a cross-flow filtration mode for separation of vapor and solid (i.e. non-volatile) particles. Demonstration of the VPS technology on aircraft engine-emitted particles has led to the improvement of the technology and increased confidence on the robustness of its field performance. In this study, the performance of the VPS was evaluated against the Particle Measurement Programme (PMP) volatile particle remover (VPR), a standardized device used in heavy duty diesel engines for separation and characterization of non-volatile particulate matter. Using tetracontane particles in the laboratory reveals that the VPS performed reasonably well in removing the volatile species. In the field conditions, a single-mode particle size distribution was found for emitted particles from a T63 turboshaft engine at both idle and cruise engine power conditions. Removal of the volatile T63 engine particles by the VPS was consistent with that of PMP VPR. In tests on an F117 turbofan engine, the size distribution at the idle (4% rated) engine power condition was found to be bimodal, with the first mode consisting of particles smaller than 10nm, which are believed to be mostly semi-volatile particles, while the second mode of larger size was a mixture of semi-volatile and non-volatile particles. The distribution was single modal at the 33% rated engine power with no secondary mode observed. Altogether, for particles emitted by both engines, the removal efficiency of the VPS appears to surpass that of the PMP VPR by 8-10%.

42 ENGINEERING↗

Comparing simulated and observed EMIC wave amplitudes using in situ Van Allen Probes’ measurements

In this study, we perform a statistical study calculating electromagnetic ion cyclotron (EMIC) wave amplitudes based off in situ plasma measurements taken by the Van Allen Probes’ (1.1–5.8 R e ) Helium, Oxygen, Proton, Electron (HOPE) instrument. Calculated wave amplitudes are compared to EMIC waves observed by the Electric and Magnetic Field Instrument Suite and Integrated Science on board the Van Allen Probes during the same period. The survey covers a 22-month period (1 November 2012 to 31 August 2014), a full Van Allen Probe magnetic local time (MLT) precession. The linear theory proxy was used to identify EMIC wave events with plasma conditions favorable for EMIC wave excitation. Two hundred and thirty-two EMIC wave events (103 H + -band and 129 He + -band) were selected for this comparison. Nearly all events selected are observed beyond L = 4. Results show that calculated wave amplitudes exclusively using the in situ HOPE measurements produce amplitudes too low compared to the observed EMIC wave amplitudes. Hot proton anisotropy (Ahp) distributions are asymmetric in MLT within the inner (L < 7) magnetosphere with peak (minimum) A hp , ~0.81 to 1.00 (~0.62), observed in the dawn (dusk), 0000 < MLT ≤ 1200 (1200 < MLT ≤ 2400), sectors. Measurements of A hp are found to decrease in the presence of EMIC wave activity. A hp amplification factors are determined and vary with respect to EMIC wave-band and MLT. Lastly, He + -band events generally require double (quadruple) the measured A hp for the dawn (dusk) sector to reproduce the observed EMIC wave amplitudes.

58 GEOSCIENCES↗

Electron Affinity and Electronic Structure of Hexafluoroacetone (HFA) Revealed by Photodetaching the [HFA] •– Radical Anion

A great deal of effort has been focused on developing a metal-free catalytic system for epoxidation of unreactive alkenes. Fluoroketones are thought as remarkably promising catalysts for epoxidation reactions. The combination of fluorinated alcohols and catalytic amounts of hexafluoroacetone (HFA) gives a versatile and effective medium for epoxidation of various olefins with hydrogen peroxide. However, the fundamental physicochemical properties of HFA remained largely unclear, although they were very important to understand the related interactions. Here, in this study, we performed a joint study on the electron affinity and electronic structure of HFA employing negative ion photoelectron (NIPE) spectroscopy and quantum chemistry calculations. Two distinct bands with complicated vibrational progressions were observed in the 193 nm NIPE spectrum. The adiabatic/vertical detachment energies (ADE/VDE) were derived to be 1.42/2.06 and 4.43/4.86 eV for the ground singlet state and excited triplet state, respectively. Using the optimized geometries and vibrational frequencies of the anion and the neutral, the Franck–Condon factors were calculated for electron detachments to produce HFA in its lowest singlet and triplet states. Good agreements are obtained hereby for both bands between the experimental and calculated NIPE spectra, when taking into account combination vibrational excitations, unequivocally revealing that HFA possesses a singlet ground state with a giant singlet–triplet energy difference (ΔE ST ). The electron affinity (EA) and ΔE ST of HFA were therefore determined to be EA = 1.42 ± 0.02 eV and ΔE ST = −3.01 eV.

Wang, Lei↗

Water Freezes at Near-Zero Temperatures Using Carbon Nanotube-Based Electrodes under Static Electric Fields

Although static electric fields have been effective in controlling ice nucleation, the highest freezing temperature ( T f ) of water that can be achieved in an electric field ( E ) is still uncertain. In this study, we performed a systematic study of the effect of an electric field on water freezing by varying the thickness of a dielectric layer and the voltage across it in an electrowetting system. Results show that T f first increases sharply with E and then reaches saturation at –3.5 °C after a critical value E of 6 × 10 6 V/m. Using classical heterogeneous nucleation theory, it is revealed that this behavior is due to saturation in the contact angle of the ice embryo with the underlying substrate. Finally, we show that it is possible to overcome this freezing saturation by controlling the uniformity of the electric field using carbon nanotubes. We achieve a T f of –0.6 °C using carbon nanotube-based electrodes with an E of 3 × 10 7 V/m. This work sheds new light on the control of ice nucleation and has the potential to impact many applications ranging from food freezing to ice production.

25 ENERGY STORAGE↗

A study of the performance of an ion shutter for drift tubes in atmospheric pressure ion mobility spectrometry: Computer models and experimental findings

Ion mobility spectra are initiated when ions, derived from a sample, are pulsed or injected through ion shutters into a drift region. The effect on signal intensity from electric fields arising from the shutter grids (E{sub s}) and a superimposed electric field of the drift tube (E{sub d}) was determined experimentally and simulated computationally for ion motion at ambient pressure. The combination of these two fields influenced shutter performance in three ways: (1) intensity of an ion peak was suppressed by increased current in the baseline due to continuous leakage of ions into the drift region from insufficient E{sub s} to block ion motion when needed, at a given value of E{sub d}; (2) the ion shutter provided maximum peak intensity with some optimal ratio of E{sub s}/E{sub d} when ions were fully blocked except using the injection time; (c) the signal intensity was reduced when the blocking voltage of the ion shutter exceeded this optimal E{sub s}/E{sub d} ratio from ion depletion at the shutter grids. The optimal ratio from the computer models was equal to 1.50, whereas a value of 2.50 was obtained from the experimental findings. This difference was attributed to nonideal geometry with the grids of the shutter and the conducting elements in the drift tube establishing both E{sub s} and E{sub d}. As both the experimental and modeling results demonstrated, a mobility dependence of ion yield from the ionization source was found to cause a mobility dependent ion signal at the collector electrode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗