Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Analysis and demonstration of a Scramaccelerator system

The Scramaccelerator, a novel type of supersonic-combustion, tube-based launcher has been developed that can accelerate almost any mass to velocities of 3 to over 7 km/sec. This paper describes the technology demonstration of the concept by firing 120-g projectiles into a 38 mm barrel at 2.8 to 3.2 km/sec. The results from the technology demonstration are presented along with calculated performance of the demonstration tests. Critical test issues discussed include sabot separation, venting requirements, and test performance. The results, obtained during testing indicate projectile accelerations were achieved of approximately 5000 g. Hence, these tests demonstrate successful Scramaccelerator operation and acceleration at approximately 1.95 times the Chapman Jouguet detonation velocity, far greater than the 1.15 to 1.3 times previously demonstrated. In addition, the tests demonstrate hypersonic propulsion at Mach numbers above 8, acceleration at greater than 3 km/s, and system integration technology sufficient to accomplish this success.

Humphrey, Joseph W.↗

Ice Accretion with Varying Surface Tension

During an icing encounter of an aircraft in flight, super-cooled water droplets impinging on an airfoil may splash before freezing. This paper reports tests performed to determine if this effect is significant and uses the results to develop an improved scaling method for use in icing test facilities. Simple laboratory tests showed that drops splash on impact at the Reynolds and Weber numbers typical of icing encounters. Further confirmation of droplet splash came from icing tests performed in the NaSA Lewis Icing Research Tunnel (IRT) with a surfactant added to the spray water to reduce the surface tension. The resulting ice shapes were significantly different from those formed when no surfactant was added to the water. These results suggested that the droplet Weber number must be kept constant to properly scale icing test conditions. Finally, the paper presents a Weber-number-based scaling method and reports results from scaling tests in the IRT in which model size was reduced up to a factor of 3. Scale and reference ice shapes are shown which confirm the effectiveness of this new scaling method.

Bilanin, Alan J.↗

Evaluation of a new six degrees of freedom couch for radiation therapy

Purpose: The aim of this work is to evaluate the geometric accuracy of a prerelease version of a new six degrees of freedom (6DoF) couch. Additionally, a quality assurance method for 6DoF couches is proposed.Methods: The main principle of the performance tests was to request a known shift for the 6DoF couch and to compare this requested shift with the actually applied shift by independently measuring the applied shift using different methods (graph paper, laser, inclinometer, and imaging system). The performance of each of the six axes was tested separately as well as in combination with the other axes. Functional cases as well as realistic clinical cases were analyzed. The tests were performed without a couch load and with a couch load of up to 200 kg and shifts in the range between −4 and +4 cm for the translational axes and between −3° and +3° for the rotational axes were applied. The quality assurance method of the new 6DoF couch was performed using a simple cube phantom and the imaging system.Results: The deviations (mean ± one standard deviation) accumulated over all performance tests between the requested shifts and the measurements of the applied shifts were −0.01 ± 0.02, 0.01 ± 0.02, and 0.01 ± 0.02 cm for the longitudinal, lateral, and vertical axes, respectively. The corresponding values for the three rotational axes couch rotation, pitch, and roll were 0.03°± 0.06°, −0.04°± 0.12°, and −0.01°± 0.08°, respectively. There was no difference found between the tests with and without a couch load of up to 200 kg.Conclusions: The new 6DoF couch is able to apply requested shifts with high accuracy. It has the potential to be used for treatment techniques with the highest demands in patient setup accuracy such as those needed in stereotactic treatments. Shifts can be applied efficiently and automatically. Daily quality assurance of the 6DoF couch can be performed in an easy and efficient way. Long-term stability has to be evaluated in further tests.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2011 Honda CR-Z 4466 - Hybrid Electric Vehicle Battery Test Results

The U.S. Department of Energy’s Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles, including testing traction batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on-road fleet testing. This report documents battery testing performed for the 2011 Honda CR-Z (VIN JHMZF1C67BS004466). Battery testing was performed by Intertek Testing Services NA. The Idaho National Laboratory and Intertek collaborate on the Advanced Vehicle Testing Activity for the Vehicle Technologies Office of the U.S. Department of Energy.

25 ENERGY STORAGE↗

2011 Honda CR-Z 2982 - Hybrid Electric Vehicle Battery Test Results

The U.S. Department of Energy’s Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles, including testing traction batteries when both the vehicles and batteries are new and at the conclusion of 160,000 miles of on-road fleet testing. This report documents battery testing performed for the 2011 Honda CR-Z (VIN JHMZF1C64BS002982). Battery testing was performed by Intertek Testing Services NA. The Idaho National Laboratory and Intertek collaborate on the Advanced Vehicle Testing Activity for the Vehicle Technologies Office of the U.S. Department of Energy.

25 ENERGY STORAGE↗

Effect of continuous gamma-ray exposure on performance of learned tasks and effect of subsequent fractionated exposures on blood-forming tissue

Sixteen monkeys trained to perform continuous and discrete-avoidance and fixed-ratio tasks with visual and auditory cues were performance-tested before, during, and after 10-day gamma-ray exposures totaling 0, 500, 750, and 1000 rads. Approximately 14 months after the performance-test exposures, surviving animals were exposed to 100-rad gamma-ray fractions at 56-day intervals to observe injury and recovery patterns of blood-forming tissues. The fixed-ratio, food-reward task performance showed a transient decline in all dose groups within 24 hours of the start of gamma-ray exposure, followed by recovery to normal food-consumption levels within 48 to 72 hours. Avoidance tasks were performed successfully by all groups during the 10-day exposure, but reaction times of the two higher dose-rate groups in which animals received 3 and 4 rads per hour or total doses of 750 and 1000 rads, respectively, were somewhat slower.

Spalding, J. F.↗

Space-Environment Effects on Optical Cables

Results obtained from the Long-Duration Exposure Facility (LDEF) JPL fiber optics experiment, which remained in low-earth orbit for 5 3/4 years, are discussed to illustrate the effects of the adverse space environment on fiber optic cables. The results of tests performed on the ten fiber optic cable samples, flown on the LDEF, are then compared to data obtained from similar laboratory tests performed on currently available fiber optic cables. The effects of radiation exposure, temperature cycling, polymer aging, and micrometeoroid impacts on fiber optic cables applied in space are discussed.

optical↗

Extravehicular Activity Testing in Analog Environments: Evaluating the Effects of Center of Gravity and Environment on Human Performance

The EVA Physiology, Systems and Performance (EPSP) Project is performing tests in different analog environments to understand human performance during Extravehicular Activity (EVA) with the aim of developing more safe and efficient systems for lunar exploration missions and the Constellation Program. The project is characterizing human EVA performance in studies using several test beds, including the underwater NASA Extreme Environment Mission Operations (NEEMO) and Neutral Buoyancy Laboratory (NBL) facilities, JSC fs Partial Gravity Simulator (POGO), and the NASA Reduced Gravity Office (RGO) parabolic flight aircraft. Using these varied testing environments, NASA can gain a more complete understanding of human performance issues related to EVA and the limitations of each testing environment. Tests are focused on identifying and understanding the EVA system factors that affect human performance such as center of gravity (CG), inertial mass, ground reaction forces (GRF), suit weight, and suit pressure. The test results will lead to the development of lunar EVA systems operations concepts and design requirements that optimize human performance and exploration capabilities. METHODS: Tests were conducted in the NBL and during NEEMO missions in the NOAA Aquarius Habitat. A reconfigurable back pack with repositionable mass was used to simulate Perfect, Low, Forward, High, Aft and NASA Baseline CG locations. Subjects performed simulated exploration tasks that included ambulation, kneel and recovery, rock pick-up, and shoveling. Testing using POGO, that simulates partial gravity via pneumatic weight offload system and a similar reconfigurable rig, is underway for a subset of the same tasks. Additionally, test trials are being performed on the RGO parabolic flight aircraft. Subject performance was assessed using a modified Cooper-Harper scale to assess operator compensation required to achieve desired performance. All CG locations are based on the assumption of a standardized 6 ft 180 lb subject. RESULTS: The modified Cooper-Harper Scale assesses desired task performance described as performance in a reduced gravity environment as compared to a 1G environment. Modified Cooper-Harper ratings of . 3 indicate no improvements are needed, ratings of 4-6 indicate improvements are desirable, and ratings . 7 indicate improvements are mandatory. DISCUSSION: Differences were noted in suited CH results based on environment at the same CG and suit pressure. Additionally, results suggest that CG location affects unsuited human performance. Subjects preferred locations near their natural CG over those that are high, aft, or a combination of high and aft. Further testing and analyses are planned to compare these unsuited results to suited performance.

Gernhardt, M.L.↗

Mechanical and Physical Properties of Both Unaged and Aged Coflon and Tefzel

This report deals with all recent mechanical testing performed on variously aged samples of Coflon and TefzeL to complete the work for Phase 1. Earlier results were reported in CAPP/M.7. Fluids A, F, G, and I have all been used for ageing in the last 12 month period, with particular attention concentrated on the effects of Fluid F as a result of discussions at the December 1995 steering committee meeting in Austin. Dramatic mechanical and physical changes occurred to Coflon in our initial studies after 4 weeks at 120 C in this sour gas mixture and so a detailed matrix was drawn up to investigate the effects of time and temperature of exposure. Subsequent tensile tests and compact tension (CT) fatigue tests were performed. Fatigue testing has been limited during this period to Coflon only; however, Tefzel CT samples have been exposed to the same conditions as the Coflon allowing the possibility for fatigue tests to be performed at a later date. Fluid A exposures during the last 6 months have been long-term at 65 C, 100 C and 120 C only. These exposures have been a continuation of earlier work and will complete the investigation of this fluid. Other chemical ageings have involved Fluid G at 120 C to confirm and investigate the hostile nature of this fluid on Coflon. Again, this fluid will not be used in Phase 2. Finally, long-term exposures in Fluid 1, a high aromatic oil mixture, were carried out to investigate the effects on the polymers of aromaticity in a simulated service fluid.

Samulak, M.↗

CRUSH TESTING OF 9977 GENERAL PURPOSE FISSILE PACKAGINGS

The 9977 General Purpose Fissile Package (GPFP) was designed in response to the adoption of the crush test requirement in the US regulations for packages for radioactive materials (10 CFR 71). This presentation on crush testing of the 9977 GPFP Reviews origins of Crush Test Requirements and implementation of crush test requirements in 10 CFR 71. SANDIA testing performed to support the rule making is reviewed. The differences in practice, on the part of the US Department of Energy from those required by the NRC for commercial purposes, are explained. The design features incorporated into the 9977 GPFP to enable it to withstand the crush test and the crush tests performed on the 9977 are described. Lessons learned from crush testing of GPFP packagings are given.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NEXT Long-Duration Test Neutralizer Performance and Erosion Characteristics

The NASA's Evolutionary Xenon Thruster (NEXT) program is developing the next-generation ion propulsion system with significant enhancements beyond the state-of-the-art to provide future NASA science missions with enhanced capabilities at a low total development cost. A Long-Duration Test (LDT) was initiated in June 2005, to verify the NEXT propellant throughput capability to a qualification-level of 450 kg, 1.5 times the anticipated throughput requirement of 300 kg per thruster based on mission analyses. As of September 2, 2009, the thruster has accumulated 24,400 hr of operation with extensive durations at the following input powers: 6.9, 4.7, 1.1, and 0.5 kW. The thruster has processed 434 kg of xenon, surpassing the NASA Solar Technology Application Readiness (NSTAR) program thruster propellant throughput demonstrated during the extended life testing of the Deep Space 1 flight spare ion thruster and approaching the NEXT development qualification throughput goal of 450 kg. The NEXT LDT has demonstrated a total impulse of 16.1 10(exp 6zzz0 N s; the highest total impulse ever demonstrated by an ion thruster. A reduction in neutralizer flow margin has been the only appreciable source of thruster performance degradation. The behavior of the neutralizer is not easily predicted due to both erosion and deposition observed in previous wear tests. Spot-to-plume mode transition flow data and in-situ erosion results for the LDT neutralizer are discussed. This loss of flow margin has been addressed through a combination of a design change in the prototype-model neutralizer to increase flow margin at low emission current and to update the NEXT throttle table to ensure adequate flow margin as a function of propellant throughput processed. The new throttle table will be used for future LDT operations. The performance of the NEXT LDT neutralizer is consistent with that observed for long-life hollow cathodes. The neutralizer life-limiting failure modes are progressing as expected and the neutralizer data indicate none of the neutralizer failures are imminent.

Herman, Daniel A.↗

Regenerative Life Support Systems (RLSS) test bed performance - Characterization of plant performance in a controlled atmosphere

By growing higher plants for food, lunar and Martian manned habitats will not only reduce resupply requirements but obtain CO2 removal and both oxygen-production and water-reclamation requirements. Plants have been grown in the RLSS at NASA-Johnson in order to quantitatively evaluate plant CO2 accumulation, O2 generation, evapotranspiration, trace-contaminant generation, and biomass productivity. Attention is presently given to test conditions and anomalies in these RLSS trials; areas where performance must be improved have been identified.

Edeen, Marybeth↗

Evaluation of Low Dose Silicon Carbide Temperature Monitors

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at materials and test reactors. Melt wires or paint spots are often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires and paint spots as a post-irradiation technique for peak temperature indication. Unfortunately, these techniques are limited in that they can only detect whether a single temperature is or is not exceeded. Silicon carbide (SiC) monitors are advantageous because a single monitor can be used to determine the peak temperature reached within a relatively broad range (200 – 800°C). Although the use of SiC monitors was proposed more than five decades ago, the ultimate performance limits of this technique are not fully understood. The Nuclear Science User Facilities (NSUF) is the United States Department of Energy Office of Nuclear Energy's only designated nuclear energy user facility. Its mission is to provide nuclear energy researchers access to world-class capabilities and to facilitate the advancement of nuclear science and technology. This mission is supported by providing access to state-of-the-art experimental irradiation testing, post irradiation examination facilities, and high performance computing capabilities as well as technical and scientific assistance for the design and execution of projects. As part of an NSUF project, low dose silicon carbide monitors were irradiated in the Belgian Reactor 2 and were then evaluated both at the SCK•CEN and at Idaho National Laboratory's High Temperature Test Laboratory to determine their peak temperature achieved during irradiation. The technical significance of this work was that the monitors were irradiated to a dose that was significantly less than recommended in published literature. This paper will discuss the evaluation process, the irradiation test, and the performance of the low dose silicon carbide temperature monitors.

36 MATERIALS SCIENCE↗

Active transmission isolation/rotor loads measurement system

Modifications were incorporated into a helicopter active transmission isolation system to provide the capability of utilizing the system as a rotor force measuring device. These included; (1) isolator redesign to improve operation and minimize friction, (2) installation of pressure transducers in each isolator, and (3) load cells in series with each torque restraint link. Full scale vibration tests performed during this study on a CH-53A helicopter airframe verified that these modifications do not degrade the systems wide band isolation characteristics. Bench tests performed on each isolator unit indicated that steady and transient loads can be measured to within 1 percent of applied load. Individual isolator vibratory load measurement accuracy was determined to be 4 percent. Load measurement accuracy was found to be independent of variations in all basic isolator operating characteristics. Full scale system load calibration tests on the CH-53A airframe established the feasibility of simultaneously providing wide band vibration isolation and accurate measurement of rotor loads. Principal rotor loads (lift, propulsive force, and torque) were measured to within 2 percent of applied load.

Kenigsberg, I. J.↗

SUMMARY OF 2009 RHEOLOGY MODIFIER PROGRAM

The overall objective of the EM-31 Rheological Modifiers and Wetting Agents program is to utilize commercially available rheology modifiers to increase the solids fraction of radioactive sludge based waste streams, resulting in an increase in throughput and decreasing the overall processing time. The program first investigates the impact of rheology modifiers on slurry simulants and then utilizes the most effective rheology modifiers on radioactive slurries. The work presented in this document covers the initial investigation of rheology modifier testing with simulants. This task is supported by both the Savannah River National Laboratory (SRNL) and Pacific Northwest National Laboratory (PNNL). The SRNL EM-31 task, for this year, was to investigate the use of rheology modifiers on simulant Defense Waste Processing Facility (DWPF) melter feeds. The task is to determine, based on the impact of the rheology modifier, if there are rheology modifiers that could reduce the water content of the slurry going to the DWPF melter, hence increasing the melt rate by decreasing the water loading. The rheology modifier in essence would allow a higher solids content slurry to have the same type of rheology or pumpability of a lower solids slurry. The modifiers selected in this report were determined based on previous modifiers used in high level waste melter feed simulants, on-going testing performed by counterparts at PNNL, and experiences gain through use of modifiers in other Department of Energy (DOE) processes such as grout processing. There were 12 rheology modifiers selected for testing, covering both organic and inorganic types and they were tested at four different concentrations for a given melter feed. Five different DWPF melter feeds were available and there was adequate material in one of the melter feeds to increase the solids concentration, resulting in a total of six simulants for testing. The mass of melter feed available in each simulant was not adequate for testing each rheology modifier, hence based on the changes in rheology for a given rheology modifier, rheology modifiers were either dropped or added between simulants. Three rheology modifiers were used on all simulants. The results from this testing indicate that citric acid or polycarboxylate based rheology modifiers are the most effective in reducing the yield stress, by as much as 70% at the higher rheology modifier additions and were effective on most of the tested simulants. These rheology modifiers are organic, hence the can also be used as reductants in melter operations. The most effective non-organic rheology modifiers, sodium metasilicate reduced the yield stress by 10%. It is recommended that both citric acid and commercially available polycarboxylate rheology modifiers be further investigated. Different molecular weight polycarboxylates and different types of polycarboxylates used in other industries must be considered. These polycarboxylates are extensively utilized in the cement, ceramic, and water treatment processes, hence readily available. Future work on DWPF melter feeds involving rheology modifiers should include, assuming the present method of processing sludge through DPWF does not change, is: (1) Investigate the use of polycarboxylate in various processes and procure polycarboxylates for testing. Limit rheology modifier selection and future testing between four and eight different types. (2) Test rheology modifiers on at least two different chemical types or bounding DWPF SME product simulants. Test to include the impact of boiling and the effectiveness in reducing water content via rheology versus weight percent curves. (3) Based on selected modifiers, perform testing on actual radioactive melter feed based on results from simulant testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

How Useful are Conventional I–Vs for Performance Calibration of Single- and Two-Junction Perovskite Solar Cells? A Statistical Analysis of Performance Data on ≈200 Cells from 30 Global Sources

As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well-documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady-state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady-state measurement methods take tens of minutes to complete, as opposed to conventional "fast" current-voltage (I-V) measurements usually lasting a few seconds. Fast I-Vs arise from a snapshot, almost always not a steady-state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I-V and with a steady-state method? Results compiled from approximately 200 perovskite PV cells, including single junction, and two-terminal perovskite-perovskite and perovskite-Si tandems, show that fast I-Vs can provide a useful measure of the open-circuit voltage of the devices, while the short-circuit current and the overall efficiency can be widely misestimated. Here, the implications of these findings on performance testing protocols are discussed and possible options for fast and accurate testing of perovskite PV are proposed.

14 SOLAR ENERGY↗

Pixel-Strip Module Testing and Performance Analysis for the CMS Phase-2 Outer Tracker Upgrade

In response to the demanding environment of the High-Luminosity Large Hadron Collider (HL-LHC), the Compact Muon Solenoid (CMS) Experiment's Outer Tracker is being replaced with a lighter, higher-granularity, radiation-tolerant silicon detector capable of providing tracking information directly to the Level-1 trigger system. The new Outer Tracker consists of Pixel-Strip (PS) and Strip-Strip (2S) transverse momentum (pT) modules, which are assembled and tested at, among other centers, Fermilab's Silicon Detector Facility. PS modules consist of a pixel sensor, a strip sensor, and multiple application-specific integrated circuits (ASICs). This poster studies the performance of MaPSAs, silicon macro-pixel sensors bump-bonded to 16 macro-pixel ASICS. It presents the testing procedures for MaPSAs and MaPSA-strip sensor sub-assemblies, as well as the results of calibration and performance studies of two PS modules before and after irradiation. These results assess the impact of irradiation on module performance, providing insight into the modules' expected performance in the HL-LHC environment.

Kimrey, Emerson [Scripps College]↗