Nuclear Energy Knowledge and Validation Center (NEKVaC) Needs Workshop Summary Report

The Department of Energy (DOE) has made significant progress developing simulation tools to predict the behavior of nuclear systems with greater accuracy and of increasing our capability to predict the behavior of these systems outside of the standard range of applications. These analytical tools require a more complex array of validation tests to accurately simulate the physics and multiple length and time scales. Results from modern simulations will allow experiment designers to narrow the range of conditions needed to bound system behavior and to optimize the deployment of instrumentation to limit the breadth and cost of the campaign. Modern validation, verification and uncertainty quantification (VVUQ) techniques enable analysts to extract information from experiments in a systematic manner and provide the users with a quantified uncertainty estimate. Unfortunately, the capability to perform experiments that would enable taking full advantage of the formalisms of these modern codes has progressed relatively little (with some notable exceptions in fuels and thermal-hydraulics); the majority of the experimental data available today is the "historic" data accumulated over the last decades of nuclear systems R&D. A validated code-model is a tool for users. An unvalidated code-model is useful for code developers to gain understanding, publish research results, attract funding, etc. As nuclear analysis codes have become more sophisticated, so have the measurement and validation methods and the challenges that confront them. A successful yet cost-effective validation effort requires expertise possessed only by a few, resources possessed only by the well-capitalized (or a willing collective), and a clear, well-defined objective (validating a code that is developed to satisfy the need(s) of an actual user). To that end, the Idaho National Laboratory established the Nuclear Energy Knowledge and Validation Center to address the challenges of modern code validation and to manage the knowledge from past, current, and future experimental campaigns. By pulling together the best minds involved in code development, experiment design, and validation to establish and disseminate best practices and new techniques, the Nuclear Energy Knowledge and Validation Center (NEKVaC or the ‘Center’) will be a resource for industry, DOE Programs, and academia validation efforts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solvent Hold Tank Sample Results for MCU-15-661-662-663: April 2015 Monthly Sample

The Savannah River National Lab (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-661, MCU-15-662, and MCU-15-663 pulled on April 2, 2015) for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-661-662-663 indicated a low concentration (~ 63% of nominal) of the suppressor (TiDG) and a slightly below the nominal concentration (~ 10% below nominal) of the extractant (MaxCalix). The modifier (CS-7SB) level was also 10% below its nominal value while the Isopar™ L level was slightly above its nominal value. This analysis confirms the addition of Isopar™L to the solvent on March 6, 2015. Despite that the values are below target component levels, the current levels of TiDG, CS-7SB and MaxCalix are sufficient for continuing operation without adding a trim at this time until the next monthly sample. No impurities above the 1000 ppm level were found in this solvent. However, the sample was found to contain approximately 18.4 ug/g solvent mercury. The gamma level increased to 8 E5 dpm/mL solvent and it represents an order of magnitude increase relative to previous solvent samples. The increase means less cesium is being stripped from the solvent. Further analysis is needed to determine if the recent spike in the gamma measurement is due to external factors such as algae or other material that may impede stripping. The laboratory will continue to monitor the quality of the solvent in particular for any new impurity or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Appendix C: Examples of Review Questions

This set of review questions was pulled from a number of EERE evaluations by the PEER Review Task Force and organized to show how questions for assessing a program differ from questions for assessing projects that make up that program.

99 GENERAL AND MISCELLANEOUS↗

Solvent Hold Tank Sample Results For MCU-15-710-711-712: June 2015 Monthly Sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-710, MCU-15-711, and MCU-15-712), pulled on 06/15/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-710-711-712 indicated a low concentration (~ 55 % of nominal) of the suppressor (TiDG) and concentrations of the extractant (MaxCalix), and of the modifier (Cs-7SB) in the solvent that were slightly lower than nominal. This analysis confirms the addition of TiDG, MaxCalix, and modifier (92 % of nominal) to the solvent in February 2015. Based on the current monthly sample, the levels of TiDG, MaxCalix, and modifier were sufficient when this solvent sample was collected from MCU. A higher cesium concentration (9.3 E6 dpm/mL) was observed in this sample relative to recent samples. In the past, this level of cesium appeared to correlate with upsets in the MCU operation. It is not known at this time the reason for the higher cesium level in this solvent. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). In addition, the sample contains up to 10.4 micrograms of mercury per gram of solvent (or 8.7 µg/mL). A relatively large cesium concentration (9.3 E 6 dpm/mL) was measured in this solvent and it may indicate poor cesium stripping. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results For MCU-15-750-751-752-: June Monthly Sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-750, MCU-15-751, and MCU-15-752), pulled on 06/22/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-750-751-752 indicated a low concentration (~ 49 % of nominal) of the suppressor (TiDG) and slightly lower than nominal concentrations of the extractant (MaxCalix), and of the modifier (Cs-7SB) in the solvent. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in February 2015. Based on the current monthly sample, the levels of TiDG, MaxCalix, and modifier are sufficient for continuing operation without adding a trim at this time but it is recommended that an addition of TiDG, modifier and Isopar™L should be made in the near future. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). In addition, up to 13.9 micrograms of mercury per gram of solvent (or 11.5 µg/mL) was detected in this sample. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sierra Structural Dynamics Theory Manual

Sierra/SD provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Sierra/SD. For a more detailed description of how to use Sierra/SD , we refer the reader to Sierra/SD, User's Notes . Many of the constructs in Sierra/SD are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Sierra/SD are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer notes manual, the user's notes and of course the material in the open literature.

97 MATHEMATICS AND COMPUTING↗

Solvent hold tank sample results for MCU-15-802-803-804-805-806-807 August monthly sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-802-803-804-805-806-807), pulled on 08/31/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-802-803-804-805-806-807 indicated a low concentration (~ 45 % of nominal) of the suppressor (TiDG) and a slightly lower than nominal concentration of the modifier (Cs-7SB) in the solvent. The extractant (MaxCalix) concentration was at its nominal value. Based on this current monthly sample, the levels of TiDG, MaxCalix, and modifier were sufficient for continuing operation without adding a trim during that time but it is recommended that an addition of TiDG, modifier and Isopar™L should be made in the next few months. This monthly sample’s rheology, as determined by Hydrogen Nuclear Magnetic Resonance (H-NMR), is consistent with the rheology of the standard NGS solvent made in the lab (Scratch solvent 5/14/2014). No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). In addition, up to 16.7 micrograms of mercury per gram of solvent (or 14 μg/mL) was detected in this sample. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

36 MATERIALS SCIENCE↗

Solvent hold tank sample results for MCU-15-815-816-817-818-819-820 November monthly sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-815-816-817-818-819-820), pulled on 11/29/2015 for analysis. The samples were inspected, combined, and analyzed for composition. Chemical analysis of the composite sample MCU-15-815-816-817-818-819-820 indicated the TiDG, Isopar™L, and MaxCalix are at nominal levels. The modifier concentration is 3% below its nominal concentration. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent on November 28, 2015. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, up to 12.5 ± 3 micrograms of mercury per gram of solvent (or 10.4 μg/mL) was detected in this sample. The solids residues found at the bottom of the p-nut vial from sample MCU-15-815 were determined to be left-over pipe residues that were flushed into the sample and they were found to have no impact on the solvent purity or on the chemical and physical properties of the solvent. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent hold tank sample results for MCU-16-53-55. January 2016 Monthly sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-53-54-55), pulled on 01/25/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-53-54-55 indicated the Isopar™L, and MaxCalix are at nominal levels. The modifier and TiDG concentrations are 3% and 23 % below their nominal concentrations. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent on November 28, 2015. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, the Fourier transform infra-red spectroscopy (FTIR) method detected trace levels (a few ppm) of amides (a possible degradation product of TiDG). In addition, up to 21 ± 4 micrograms of mercury per gram of solvent (or 17.5 μg/mL) was detected in this sample. There appears to be a possible correlation between the mercury level and the TiDG concentration in the solvent. The current gamma level (9.16 E4 dpm/mL) confirmed that the gamma concentration has returned to previous level where the process operated normally and as expected. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent hold tank sample results for MCU-15-914-915-916. December 2015 Monthly sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-914-915-916), pulled on 12/22/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-914-915-916 indicated the TiDG, Isopar™L, and MaxCalix are at nominal levels. The modifier concentration is 3% below its nominal concentration. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in November 2015. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, the Fourier transform infra-red spectroscopy (FTIR) method detected trace levels (a few ppm) of amides (more indicative of bacteria than a possible degradation product of TiDG). In addition, up to 18 ± 4 micrograms of mercury per gram of solvent (or 14.8 μg/mL) was detected in this sample. The current gamma concentration level (8.48E4 dpm/mL) confirmed that the gamma concentration has returned to the previous level where the process operated normally as expected. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Atmospheric Observation System for Greenhouse Gases (GHG) Instrument Handbook

The Greenhouse Gas (GhG) Measurement system is a combination of two systems in series: (1) the Tower Gas Processing (TGP) System, an instrument rack which pulls, pressurizes, and dries air streams from an atmospheric sampling tower through a series of control and monitoring components, and (2) the Picarro model G2301 cavity ringdown spectrometer (CRDS), which measures CO2, CH4, and H2O vapor; the primary measurements of the GhG system.

54 ENVIRONMENTAL SCIENCES↗

Fuel Cell Powered Lift Truck

This project, entitled “Recovery Act: Fuel Cell-Powered Lift Truck Sysco (Houston) Fleet Deployment”, was in response to DOE funding opportunity announcement DE-PS36-08GO98009, Topic 7B, which promotes the deployment of fuel cell powered material handling equipment in large, multi-shift distribution centers. This project promoted large-volume commercialdeployments and helped to create a market pull for material handling equipment (MHE) powered fuel cell systems. Specific outcomes and benefits involved the proliferation of fuel cell systems in 5-to 20-kW lift trucks at a high-profile, real-world site that demonstrated the benefits of fuel cell technology and served as a focal point for other nascent customers. The project allowed for the creation of expertise in providing service and support for MHE fuel cell powered systems, growth of existing product manufacturing expertise, and promoted existing fuel cell system and component companies. The project also stimulated other MHE fleet conversions helping to speed the adoption of fuel cell systems and hydrogen fueling technology. This document also contains the lessons learned during the project in order to communicate the successes and difficulties experienced, which could potentially assist others planning similar projects.

30 DIRECT ENERGY CONVERSION↗

Colorado State Capitol Geothermal project

Colorado State Capitol Geothermal Project - Final report is redacted due to space constraints. This project was an innovative large-scale ground-source heat pump (GSHP) project at the Colorado State Capitol in Denver, Colorado. The project employed two large wells on the property. One for pulling water from the aquifer, and another for returning the water to the aquifer, after performing the heat exchange. The two wells can work in either direction. Heat extracted/added to the water via a heat exchanger is used to perform space conditioning in the building.

15 GEOTHERMAL ENERGY↗

Department of Energy. Jobs and Innovation Accelerator Challenge (JIAC) Program

1.1 NCMS Digital Manufacturing Initiative The people and businesses of Southeast Michigan have long been known for their prowess in the automotive industry, a sector built on the innovation of the assembly line and the rise of mass production as a manufacturing model. Just as the assembly line was the key to a strong manufacturing base a century ago, a digital manufacturing infrastructure is critical to the future of industry. Economic uncertainty has slowed innovation, but access to cutting-edge tools such as high performance modeling, simulation and analysis (MSA) provides a bold path forward, ensuring global competitiveness and transforming our manufacturing processes. Digital manufacturing is, essentially, the virtualization of processes that had been physical. Many larger manufacturers have embraced it, but the majority of small and medium-sized manufacturers (SMMs) have not. The Digital Manufacturing Initiative is a bold, national effort by the National Center for Manufacturing Sciences (NCMS) to put manufacturing innovation on fast forward, and bring the future of industry into the present. SMMs need a broader array of access options, training, support, and guidance. Providing access will supercharge any organization with tomorrow’s tools, as positively disruptive and potential-laden as the assembly line once was. Sustainable success in the State of Michigan requires the development of foundational infrastructure, the exploration of initial inroads with various manufacturers of all sizes, and the initiation of a prototype engagement mechanism applicable for other future regional efforts. To accomplish this NCMS leveraged complimen-tary State and Federal funding opportunities (shown in Figure 1) along with a coupled voice of industry market research study. A brief summary of each opportunity is found in Appendix A. At the heart of the Michigan effort was the development of an access portal (www.doitindigital.com) and the development of partnerships with local large manufacturers (OEMs) who could provide pull to encourage SMMs (current and future suppliers) to participate. Central to this entire effort was the opportunity that this Final Report documents corresponding to the specific tasks associated with the U.S. Department of Energy (DOE) funded component of the InnoState Jobs Innovation Accelerator Challenge (JIAC) Program.

99 GENERAL AND MISCELLANEOUS↗

Insights from Smart Meters. Ramp-up, dependability, and short-term persistence of savings from Home Energy Reports

Smart meters, smart thermostats, and other new technologies provide previously unavailable high-frequency and location-specific energy usage data. Many utilities are now able to capture real-time, customer specific hourly interval usage data for a large proportion of their residential and small commercial customers. These vast, constantly growing streams of rich data (or, “big data”) have the potential to provide novel insights into key policy questions about how people make energy decisions. The richness and granularity of these data enable many types of creative and cutting-edge analytics. Technically sophisticated and rigorous statistical techniques can be used to pull useful insights out of this high-frequency, human-focused data. In this series, we call this “behavior analytics.” This kind of analytics has the potential to provide tremendous value to a wide range of energy programs. For example, disaggregated and heterogeneous information about actual energy use allows energy efficiency (EE) and/or demand response (DR) program implementers to target specific programs to specific households; enables evaluation, measurement and verification (EM&V) of energy efficiency programs to be performed on a much shorter time horizon than was previously possible; and may provide better insights into the energy and peak hour savings associated with EE and DR programs (e.g., behavior-based (BB) programs). The goal of this series is to enable evidence-based and data-driven decision making by policy makers and industry stakeholders, including program planners, program administrators, utilities, state regulatory agencies, and evaluators. We focus on research findings that are immediately relevant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solvent Hold Tank Sample Results for MCU-16-270-271-272: February 2016 Monthly Sample

Savannah River National Lab (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-270-271-272), pulled on 02/21/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-270-271-272 indicated the Isopar TM L concentration is above its nominal level (101%). The modifier (CS-7SB), the extractant (MaxCalix), and the TiDG concentrations are 7%, 6%, and 40% below their nominal concentrations. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in November 2015. Based on the current monthly sample, the levels of TiDG, Isopar TM L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-16-348-349-350: March 2016 Monthly Sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-348-349-350), pulled on 03/30/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-348-349-350 indicated the Isopar TM L concentration is above its nominal level (101%). The modifier (CS-7SB) and the TiDG concentrations are 9% and 55% below their nominal concentrations. This analysis confirms the solvent may require the addition of TiDG, and possibly of modifier. Based on the current monthly sample, the levels of TiDG, Isopar TM L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-16-596-597-598: April 2016 Monthly Sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-596-597-598), pulled on 04/30/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-596-597-598 indicated the Isopar™L concentration is above its nominal level (102%). The modifier (CS-7SB) is 14% below its nominal concentration, while the TiDG and MaxCalix concentrations are at and above their nominal concentrations, respectively. This analysis confirms the solvent may require the addition of modifier. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗