Search NASA⌕ Search

SEARCH · Search NASA

Results for “replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Replacement of a Photomultiplier Tube with Silicon Photomultipliers for use in Safeguards Applications

We compared the performance of a SiPM array and a PMT in a laboratory setting using a single 5.08x5.08-cm cylindrical sodium iodide scintillating crystal. Photomultiplier tubes (PMTs) are the most commonly used device to monitor scintillating materials for radiation detection purposes. The systems are sometimes limited by disadvantages in the PMTs that may degrade their performance, including temperature dependence and variation with magnetic field. Instrumentation engineering must also contend with a potentially large volume relative to the active scintillator volume, fragility, and high voltage requirements. One possible alternative is an array of silicon photomultipliers (SiPMs). Measurements were made with a 5.04x5.04-cm sensL J-series SiPM array and a 7.62cm Hamamatsu PMT. We demonstrated how the SiPM bias can be sufficiently altered to remove the effects of temperature variation encountered in environments where nuclear safeguards work is often performed. Finally, we evaluated a method of determining enrichment levels of 235 U at various levels and shielding configurations, using both the PMT-mounted and SiPM-mounted scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Filter replacement lifetime prediction

Systems for predicting a filter lifetime. A filter monitoring system includes a filter effectiveness history based on contaminant sensor information associated with a filter received from one or more contaminant sensors. A lifetime module is configured to determine a rate of filter consumption based on the filter effectiveness history and to determine a remaining filter lifetime based on the determined rate of filter consumption.

42 ENGINEERING↗

Filter replacement lifetime prediction

A system for increasing filter economy includes a memory configured to receive measurements of contaminants in an internal and an external environment. A cost effectiveness module is configured to determine a cost of a corrosion rate increase if unfiltered external air intake is increased for cooling, to determine a cost of increased air pressure to filter external air, and to determine if the cost of filtering external air exceeds the cost of the corrosion rate increase. An air intake module is configured to increase an intake of unfiltered external air if it is determined that the cost of filtering external air exceeds the cost of the corrosion rate increase.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovative Approach to Rooftop Unit Replacement for Schools: Advanced RTU Campaign

This case study describes Fontana Unified School District’s use of Proposition 39 grant money to install 201 high-efficiency RTUs in 30 buildings across four schools in California. The work resulted in $214,000 saved per year and was the first phase of a three-part project that includes updated controls, LED lighting and lighting control systems, and an additional 150-190 high-efficiency RTUs.

rooftop unit, RTU, LED, lighting, controls, public↗

Critical Analysis of Replacements for R-410A in Heat Pump Applications

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Research has shown that using heat exchangers with small diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants due to reduced refrigerant charge, reduced flammable impact and environmental impact. However, application of small diameter tube requires in-depth component design optimization to make the new system adapt to low-GWP refrigerants.In this paper, multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm on a R-410A residential 5-ton air source heat pump is performed for improved system performance and reduced material cost. Five R-410A alternatives, i.e., R-32, R-454A, R-454B, R-454C and R-455A are investigated. R-455A and R-454C have GWP lower than 150. As a result of optimization, 12.4%-19.1% Energy Efficiency Ratio (EER) improvement and up to 71% HXs material cost saving is achieved. Life Cycle Climate Performance (LCCP) analysis shows that optimized systems reduce total CO2 emission by 13%-33% depending on the choice of refrigerant and climate zone.The optimal heat exchangers resulting from this research can fit into the original R-410A fan-coil units. The proposed heat pump design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗