Search NASA⌕ Search

SEARCH · Search NASA

Results for “security operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Rapid CFD Using Machine Learning Algorithms (CRADA Final Report)

This is a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (“LLNL”) and Guardian Glass, LLC ("Guardian Glass") to develop a fast-running emulator of the reactive Computational Fluid Dynamics (“CFD”) simulations needed to understand the complex reactions and flows in the glass melting, fining, and forming subprocesses. This CRADA project is sponsored under the High-Performance Computing for Manufacturing (“HPC4Mfg”) Program of the Department of Energy’s Advanced Manufacturing Office (“AMO”) within the Energy Efficiency and Renewable Energy (“EERE”) Office.

36 MATERIALS SCIENCE↗

Enhanced AFCI Sampling, Analysis, and Safeguards Technology Review

The focus of this study includes the investigation of sampling technologies used in industry and their potential application to nuclear fuel processing. The goal is to identify innovative sampling methods using state of the art techniques that could evolve into the next generation sampling and analysis system for metallic elements. Sampling and analysis of nuclear fuel recycling plant processes is required both to monitor the operations and ensure Safeguards and Security goals are met. In addition, environmental regulations lead to additional samples and analysis to meet licensing requirements. The volume of samples taken by conventional means, can restrain productivity while results samples are analyzed, require process holding tanks that are sized to meet analytical issues rather than process issues (and that create a larger facility footprint), or, in some cases, simply overwhelm analytical laboratory capabilities. These issues only grow when process flowsheets propose new separations systems and new byproduct material for transmutation purposes. Novel means of streamlining both sampling and analysis are being evaluated to increase the efficiency while meeting all requirements for information. This report addresses just a part of the effort to develop and study novel methods by focusing on the sampling and analysis of aqueous samples for metallic elements. It presents an overview of the sampling requirements, including frequency, sensitivity, accuracy, and programmatic drivers, to demonstrate the magnitude of the task. The sampling and analysis system needed for metallic element measurements is then discussed, and novel options being applied to other industrial analytical needs are presented. Inductively coupled mass spectrometry instruments are the most versatile for metallic element analyses and are thus chosen as the focus for the study. Candidate novel means of process sampling, as well as modifications that are necessary to couple such instruments to introduce these samples, are discussed. A suggested path forward based on an automated microchip capillary based sampling system interfaced to the analysis spectrometer is presented. The ability to obtain micro liter volume samples coupled with remote automated means of sample tracking and transport to the instrument would greatly improve analytical efficiency while reducing both personnel exposure and radioactive waste. Application of this sampling technique to new types of mass spectrometers for selective elemental isotopic analysis could also provide significant improvements in safeguards and security analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions Calendar Year 2009

The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada Test Site (NTS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NTS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NTS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NTS. After nuclear testing ended in 1992, NTS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium were also emitted to air at the NLVF, an NTS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) limits the release of radioactivity from a U.S. Department of Energy facility to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation not related to NTS activities. Unrelated doses could come from naturally occurring radioactive elements or from sources such as medically or commercially used radionuclides. The NTS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the sole method used since 2005. Six locations on the NTS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration of each detected radionuclide at each of these locations is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2. At any one location, if multiple radionuclides are detected, then compliance with NESHAP is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. In 2009, the potential dose from radiological emissions to air, resulting from both current and past NTS activities, at onsite compliance monitoring stations was a maximum of 1.69 mrem/yr, well below the 10 mrem/yr dose limit. Air sampling data collected at all six critical receptor stations had average concentrations of radioactivity that were a fraction of the CL values listed in Table 2 in Appendix E of 40 CFR 61. Concentrations ranged from less than 1 percent to a maximum of 17 percent of the allowed NESHAP limit. Because the nearest member of the public resides approximately 20 kilometers from potential release points on the NTS, concentrations at this location would be only a small fraction of that measured on the NTS. The potential dose to the public from NLVF emissions was also very low at 0.000044 mrem/yr, 230,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions Calendar Year 2009

The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada Test Site (NTS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NTS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NTS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NTS. After nuclear testing ended in 1992, NTS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium were also emitted to air at the NLVF, an NTS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) limits the release of radioactivity from a U.S. Department of Energy facility to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation not related to NTS activities. Unrelated doses could come from naturally occurring radioactive elements or from sources such as medically or commercially used radionuclides. The NTS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the sole method used since 2005. Six locations on the NTS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration of each detected radionuclide at each of these locations is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2. At any one location, if multiple radionuclides are detected, then compliance with NESHAP is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. In 2009, the potential dose from radiological emissions to air, resulting from both current and past NTS activities, at onsite compliance monitoring stations was a maximum of 1.69 mrem/yr, well below the 10 mrem/yr dose limit. Air sampling data collected at all six critical receptor stations had average concentrations of radioactivity that were a fraction of the CL values listed in Table 2 in Appendix E of 40 CFR 61. Concentrations ranged from less than 1 percent to a maximum of 17 percent of the allowed NESHAP limit. Because the nearest member of the public resides approximately 20 kilometers from potential release points on the NTS, concentrations at this location would be only a small fraction of that measured on the NTS. The potential dose to the public from NLVF emissions was also very low at 0.000044 mrem/yr, 230,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Elastic Analysis Facility's (EAF's) Contribution to the Future of Analysis at Multi-Experiment Institutions and Future Colliders

The Elastic Analysis Facility (EAF) hosted at Fermi National Accelerator Laboratory (Fermilab) is a platform being developed with the goal of providing a fast and efficient facility for physics analysis. As high-energy physics moves towards collecting larger datasets, such as those from the High-Luminosity LHC, the EAF strives to provide a powerful and adaptable framework for future colliders and multi-experiment institutions. Currently, the EAF supports several experiments including CMS, NOvA, and DUNE as well as serving accelerator physicists and beam line operations through integrated software and secure connections to Fermilab's computing resources. In addition, the EAF was designed with a user-friendly interface, intended to be more intuitive for emerging generations of physicists, that is still accessible for established styles of analysis. The EAF can also achieve better analysis efficiency due to the modernization of software and tools that can better utilize Fermilab's computing power. Furthermore, its design incorporates industry standards whenever possible, enhancing its sustainability and making it a possible template for other national or international laboratories and research facilities. Overall, the EAF is a forward-looking solution that will meet the evolving needs of particle physics, ensuring readiness for future colliders and multi-experiment research institutions.

Chavez, Elise [Wisconsin U., Madison]↗

Fixed vacuum plate clamps styrofoam for machining

Aluminum plate holds styrofoam securely in place for machining operations. The styrofoam is clamped to rubber or cork pads on the plate surface by vacuum. Foam rubber tape provides the vacuum seal.

Rauschl, J. A.↗

Electron multiplier has improved performance and stability

Electron multiplier contains a series of massive metal dynodes, compactly secured with ceramic rods for operation in a metal housing. The housing is rigidly mounted within a soft steel vacuum enclosure which shields the multiplier from the effects of external electromagnetic fields.

Source record↗

Hand-Held Power Clamp

Tool furnishes large pushing or pulling forces. Device includes two clamping blocks, two clamping plates, and a motor-driven linear actuator with selflocking screw shaft. Power clamp exerts opening or closing force at push of switch. Tool approximately 1 m long. Originally designed to secure payload aboard Space Shuttle, operated with one hand to apply opening or closing force of up to 1,000 lb (4,400 N). Clamp has potential applications as end effector for industrial robots and in rescue work to push or pull wreckage with great force.

Clancy, J. P.↗

Mission operations concepts for Earth Observing System (EOS)

Mission operation concepts are described which are being used to evaluate and influence space and ground system designs and architectures with the goal of achieving successful, efficient, and cost-effective Earth Observing System (EOS) operations. Emphasis is given to the general characteristics and concepts developed for the EOS Space Measurement System, which uses a new series of polar-orbiting observatories. Data rates are given for various instruments. Some of the operations concepts which require a total system view are also examined, including command operations, data processing, data accountability, data archival, prelaunch testing and readiness, launch, performance monitoring and assessment, contingency operations, flight software maintenance, and security.

Kelly, Angelita C.↗

Metabonomics for detection of nuclear materials processing.

Tracking nuclear materials production and processing, particularly covert operations, is a key national security concern, given that nuclear materials processing can be a signature of nuclear weapons activities by US adversaries. Covert trafficking can also result in homeland security threats, most notably allowing terrorists to assemble devices such as dirty bombs. Existing methods depend on isotope analysis and do not necessarily detect chronic low-level exposure. In this project, indigenous organisms such as plants, small mammals, and bacteria are utilized as living sensors for the presence of chemicals used in nuclear materials processing. Such 'metabolic fingerprinting' (or 'metabonomics') employs nuclear magnetic resonance (NMR) spectroscopy to assess alterations in organismal metabolism provoked by the environmental presence of nuclear materials processing, for example the tributyl phosphate employed in the processing of spent reactor fuel rods to extract and purify uranium and plutonium for weaponization.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Learning to Apply Metrology Principles to the Measurement of X-ray Intensities in the 500 eV to 110 keV Energy Range

National Security Technologies, LLC (NSTec), Livermore Operations, has two optical radiation calibration laboratories accredited by “the National Voluntary Laboratories Accreditation Program (NVLAP) which is the accrediting body of” the National Institute of Standards and Technology (NIST), and is now working towards accreditation for its X-ray laboratories. NSTec operates several laboratories with X-ray sources that generate X-rays in the energy range from 50 eV to 115 keV. These X-ray sources are used to characterize and calibrate diagnostics and diagnostic components used by the various national laboratories, particularly for plasma analysis on the Lawrence Livermore National Laboratory (LLNL) National Ignition Facility (NIF). Because X-ray photon flux measurement methods that can be accredited, i.e., traceable to NIST, have not been developed for sources operating in these energy ranges, NSTec, NIST, and the National Voluntary Accreditation Program (NVLAP) together have defined a path toward the development and validation of accredited metrology methods for X-ray energies. The methodology developed for the high energy X-ray (HEX) Laboratory was NSTec’s starting point for X-ray metrology accreditation and will be the basis for the accredited processes in the other X-ray laboratories. This paper will serve as a teaching tool, by way of this example using the NSTec X-ray sources, for the process and methods used in developing an accredited traceable metrology.

07 ISOTOPE AND RADIATION SOURCES↗

Exploration and Resource Assessment at Mountain Home Air Force Base, Idaho Using an Integrated Team Approach

The U.S. Air Force is facing a number of challenges as it moves into the future, one of the biggest being how to provide safe and secure energy to support base operations. A team of scientists and engineers met at Mountain Home Air Force Base near Boise, Idaho, to discuss the possibility of exploring for geothermal resources under the base. The team identified that there was a reasonable potential for geothermal resources based on data from an existing well. In addition, a regional gravity map helped identify several possible locations for drilling a new well. The team identified several possible sources of funding for this well—the most logical being to use U.S. Department of Energy funds to drill the upper half of the well and U.S. Air Force funds to drill the bottom half of the well. The well was designed as a slimhole well in accordance with State of Idaho Department of Water Resources rules and regulations. Drilling operations commenced at the Mountain Home site in July of 2011 and were completed in January of 2012. Temperatures increased gradually, especially below a depth of 2000 ft. Temperatures increased more rapidly below a depth of 5500 ft. The bottom of the well is at 5976 ft, where a temperature of about 140°C was recorded. The well flowed artesian from a depth below 5600 ft, until it was plugged off with drilling mud. Core samples were collected from the well and are being analyzed to help understand permeability at depth. Additional tests using a televiewer system will be run to evaluate orientation and directions at fractures, especially in the production zone. A final report on the well exploitation will be forthcoming later this year. The Air Force will use it to evaluate the geothermal resource potential for future private development options at Mountain Home AFB.

15 GEOTHERMAL ENERGY↗

Stacked, Filtered Multi-Channel X-Ray Diode Array

This system meets the need for a low-cost, robust X-ray diode array to use for experiments in hostile environments on multiple platforms, and for experiments utilizing forces that may destroy the diode(s). Since these uses require a small size with a minimal single line-of-sight, a parallel array often cannot be used. So a stacked, filtered multi-channel X-ray diode array was developed that was called the MiniXRD. The design was modeled, built, and tested at National Security Technologies, LLC (NSTec) Livermore Operations (LO) to determine fundamental characteristics. Then, several different systems were fielded as ancillary “ridealong” diagnostics at several national facilities to allow us to iteratively improve the design and usability. Presented here are design considerations and experimental results. This filtered diode array is currently at Technical Readiness Level (TRL) 6.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concurrent Uranium Overmass and Hydraulic Fluid Leak

In the Spring of 2017, the Y-12 National Security Complex had a NCS operational event involving hydraulic fluid leaking into a glovebox containing fissile material. The hydraulic fluid intermixed with fissile material in the glovebox but remained in a safe slab-like configuration. Unknown at the time, a large enough mass of uranium to support a moderated nuclear criticality accident resided below the glovebox floor in an unfavorable volume sand separator system. Thanks to the operator following procedures and shutting down the hydraulic pump supplying the jolter, a potential accident was adverted. As a result of the event, significant physical modifications were made to the process to enhance safety. Additionally, changes were made in how the materials in the glovebox are processed in order to prevent liquid intrusion and significant uranium accumulation in the sand separator system.

42 ENGINEERING↗

Analyzing Insider Risk Threat to the Internet of Things (IoT)

Recent technological advancement has created a growing convergence of innovation. From machine learning to ubiquitous computing to wireless networks and automation, the world is seeing new technology increasingly capable of connecting with each other. Devices and systems use open communications networks to interact, process information, and react. This is called the Internet of Things (IoT) and is comprised of physical devices that exchange data over networks, creating revolutionary possibilities. The most common way most people interact with an IoT is through ‘smart home’ products like Amazon’s Alexa, which use microphones, speakers, and phones to control a variety of devices, from lights and thermostats, to cameras, to appliances and vacuum cleaners. But the open nature of IoT networks—necessary for their ability to communicate and operate—also introduces privacy and security concerns. At a personal level, this might mean a hack into a home to steal private information, but when applied in broader industries like healthcare, transportation, manufacturing, or the military, this vulnerability can have serious consequences. As IoT usage and interconnectivity increases, so too does the susceptibility to malicious actors. And the entire system is only as secure as its least secure member. This creates particular risk and vulnerability to radiological material industries, as a competent insider adversary could utilize the IoT to potentially steal or access classified or sensitive information about employees, sites, or systems; or simply sabotage security or maintenance from a more remote—and less secure—device. The IoT relies on a secure network across the entire system, especially in transport which may lack the security of more permanent locations; if one device fails, it can create a ripple effect and an insider threat may seek to exploit that connectivity. While IoT benefits drive increased innovation and usage, there are also vulnerabilities an insider threat could exploit; this risk of an IoT to radiological material must be addressed in any mitigation effort.

Kinney, Justin↗

Standards and Guidelines for the Design of Trunnions of RAM Transport Packages - 17365

Trunnion systems of packages for the transport of radioactive materials have to guarantee the safe handling of package during crane operations (lifting, tilting) and to secure package tie down to the transport vehicle, if the trunnions are used as attachment points during transport. The design of trunnions is based on IAEA Regulations SSR-6, the supporting Advisory Material SSG-26 and further appropriate technical standards and/or guidelines. For package approval procedures in Germany the guideline BAM-GGR 012 has to be applied. If a package is handled inside a german nuclear power plant, the standard KTA 3905 has to be fulfilled additionally. In this paper the requirements of KTA 3905 [4] concerning the trunnion systems as load attaching points (LAP) are discussed in connection with the recommendations in the guideline BAM-GGR 012 [3]. This guideline is prepared at BAM Federal Institute for Materials Research and Testing for analysis and assessment of bolted lid and trunnion systems of Type B(U) transport packages. The quality assurance questions concerning trunnion systems are discussed as well. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Site-Specific Studies for Removing SNF from Six Shutdown Sites - 18042

The US Department of Energy (DOE) is exploring options for developing a large-scale transportation system for the safe transport of spent nuclear fuel (SNF) and high-level radioactive waste to future storage or disposal facilities. This complex, large-scale transportation system will involve coordinated, integrated activities. Interfaces with various transportation and non-transportation activities must be defined, and systems must be developed to ensure successful integration when the system becomes operational. To provide an understanding of the tasks and interfaces required for the complete de-inventory of particular sites where SNF is stored, DOE solicited bids from integrating contractors to develop initial site-specific de-inventory reports. The reports were developed for several nuclear power plant sites selected to represent a range of geographic locations, existing on-site SNF storage systems, and expected transportation modal options. Each report is presented in a self-contained narrative describing a potential campaign for removing all SNF and greater-than-class-C low-level radioactive waste (GTCC waste) from each specified site. Each study narrative includes site information; an analysis of the near-site transportation infrastructure; a concept of operations for the de-inventory; an estimated budget and schedule for the duration of operations; and a safety and security plan with site-specific considerations, emergency response considerations, and recommendations for the next steps DOE could take to de-inventory the site. The reports provide cost estimates for analytical purposes only; they do not attempt to specify the party or parties responsible for the costs. These reports present a first look at how an integrating contractor might recommend removing SNF from particular sites. They are written from the perspective of the contractor and do not represent DOE's plans. At this writing, six sites have been studied: - Connecticut Yankee, - Big Rock Point, - Humboldt Bay, - Maine Yankee, - Trojan, - Kewaunee. DOE may develop de-inventory reports for all reactor sites, with an initial focus on shutdown reactor sites. The order in which sites have been selected for study should not be considered an indicator of the order used by DOE to remove SNF from the sites. Since the SNF's destination is not important for the purpose of this work, DOE tasked the contractor with planning transportation of the SNF from the site to a generic railroad location in the approximate geographical center of the United States. These reports represent an initial study of the specific sites. Per the terms of the contract, the contractor was not permitted to engage in dialogue with power plant site personnel; near-site railroad personnel; or any local, state, or regional stakeholders about the studies. DOE provided site-specific data. The contractor was tasked to rely on past corporate experience, data available from DOE, and publicly available data when making site-specific recommendations for removing all SNF from each site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗