Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

HyPerPy (Hydrogen Extraction and Parabolic Trough Plant Performance Models using Python) [SWR-21-53]

The HyPerPy package consists of three scripts: 1) Model for Hydrogen Tracking in Parabolic Trough Power Plants, 2) Model for Receiver Performance, and 3) Model for Hydrogen Extraction Process. The power plant model (1) tracks hydrogen generation and transport within the circulating heat transfer fluid (HTF) of the power plant. This script is a transient, initial value simulation, in which the hydrogen concentration in the circulating HTF is 0 moles per cubic meter everywhere at time 0 seconds. Hydrogen concentration is calculated at discrete locations within the circulating HTF with 4-second time resolution. During each time step, the change in hydrogen concentration due to hydrogen generation and permeation is calculated for each location according to the local HTF temperature, vessel or piping properties, hydrogen concentration and partial pressure. This model predicts hourly hydrogen concentrations for typical operating days in the spring, summer, fall, and winter seasons. Data is used to create hourly mappings of hydrogen concentrations for a typical operating year. The receiver model (2) uses a 1-hour time step to estimate getter loading and annulus pressure. For each time step, the model uses HTF and ambient temperature data to estimate absorber tube, bellows, and getter temperatures for the time step. In addition, the model uses hourly HTF hydrogen concentrations that are generated by the power plant model (1), and annulus hydrogen pressure from the previous time step. With these data, the model calculates the moles of hydrogen permeating across the absorber tube and bellows during the time step. The net change in moles hydrogen is added or subtracted from the getter loading for the previous time step, and the hydrogen pressure is re-calculated based on getter loading and temperature. The model uses this algorithm to simulate hydrogen permeation and loading 24 hours per day, 365 days per year using seasonal temperature data. The model repeats these calculations for 25 years to create a mapping of receiver getter loading and annulus hydrogen pressure for four seasons of each year. The model for hydrogen extraction (3) estimates hydrogen extraction rates for a specific separation module configuration. The rate depends primarily on membrane area, vacuum pump performance, headspace gas flowrate to the membrane, and headspace gas hydrogen partial pressure. This model has two versions. The steady-state version predicts hydrogen extraction rates when the module is operating in separation mode. The dynamic version predicts hydrogen transfer through the membrane when the module is operating in sensor mode. The steady-state version is used with the plant model (1) to predict hydrogen partial pressures in the power plant when the extraction process is operating.

Glatzmaier, Gregory↗

Duke Forest FACE (FACTS-I): Carbon Dioxide (CO2) Concentration, 1993-2007

This dataset, collected from Duke Forest Free Air CO2 Enrichment (FACE) – Forest-Atmosphere Carbon Transfer and Storage (FACTS-I) experiment, includes carbon dioxide (CO2) concentrations at 30-minute resolution from 1993-01-01 to 2007-13-31. The Duke FACE experiment was located in a loblolly pine (Pinus taeda L.) plantation established in 1983. Naturally regenerated broadleaved species including sweetgum (Liquidambar styraciflua L.) and tulip poplar (Liriodendron tulipifera L.), mostly in the overstory, and winged elm (Ulmus alata Michx.) and red maple (Acer rubrum L.) were common in the understory. The FACE experiment commenced with two plots (plots 7-8) in 1994 (Oren et al. 2001), with six additional plots (plots 1-6) coming online on 27 August 1996. Beginning in 1997, data are available from 8 experimental plots and an ambient sensor near the site. Data for 1993-1996 are modeled ambient CO2 data based on measured data since 1997. The FACTS-I experiment explored how forests store carbon, cycle nutrients, and interact with the atmosphere. Insights from this work may improve ecosystem and carbon cycle models, supporting more accurate predictions of how forests may function under future environmental conditions. This dataset contains two data files in comma separate (.csv) format. Additional metadata are provided: two data dictionaries and a file-level metadata file in comma separate (.csv) format.

Carbon dioxide↗

Sap flux measurements in wet tropical forests: unique challenges and opportunities

Tropical rainforests often have great tree species and functional diversity, complex age and stand structure, deep active sapwood, and potential factors that reduce transpiration, such as frequent cloud cover and wet leaves. Such factors generate challenges for estimating transpiration from sap flux measurements. In fact, upscaling approaches have rarely been attempted for diverse tropical forests. Thus, the objective of this paper is to build upon past efforts to scale transpiration and optimize strategies for wet tropical forests. Over a five-year period, we instrumented 44 trees with heat dissipation sap flow sensors within a premontane wet tropical rainforest in Costa Rica (5000 mm MAP). Given high diversity, few instrumented trees belonged to the same species, genus, or even family. In a subset of trees, radial profiles across the full range of active xylem were examined. Measurements were scaled to the stand in two plots using sapwood area. In association with extensive micrometeorological measurements, only ~10% of rainfall was transpired from this forested watershed due to persistent low radiation, evaporative demand, and frequent wet canopy conditions. Contrary to temperate trees, we observed minimal flow reductions in deeper sapwood among the largest trees, whose water use amounted to nearly 80% of the total stand water use, even though they contributed less than 15% to total stand basal area. We found that transpiration was suppressed when leaves were wet, even after accounting for lower vapor pressure deficit and reduced solar radiation. Since soil moisture conditions at this site remain continually above deficit levels, flow reversal has been assumed to be minor and thus has not yet been investigated. The driest month on record resulted in higher, not lower transpiration. Given the high diversity of these forests, herein we propose practical and innovate approaches to group trees by function or degree of canopy exposure. Finally, these efforts are critical for accurate scaling of measurements from individual sensors to stands and for improving global land surface models that increasingly partition canopy components to better represent these functionally and structurally diverse ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Towards A Topological Framework for Integrating Semantic Information Sources

In this position paper we argue for the role that topological modeling principles can play in providing a framework for sensor integration. While used successfully in standard (quantitative) sensors, we are developing this methodology in new directions to make it appropriate specifically for semantic information sources, including keyterms, ontology terms, and other general Boolean, categorical, ordinal, and partially-ordered data types. We illustrate the basics of the methodology in an extended use case/example, and discuss path forward.

Joslyn, Cliff A.↗

Fugitive Methane Gas Emission Monitoring in oil and gas industry

Identifying fugitive methane leaks allow optimization of the extraction process, can extend gas extraction equipment lifetime, and eliminate hazardous work conditions. We demonstrate a wireless sensor network based on cost effective and robust chemi-resistive methane sensors combined with real time analytics to identify leaks from 2 scfh to 10000 scfh. The chemi-resistive sensors were validated for sensitivity better than 1 ppm of methane plume detection. The real time chemical sensor and wind data is integrated into an inversion models to identify the location and the magnitude of the methane leak. This integrated solution can be deployed in outdoor environment for long term monitoring of chemical plumes.

Klein, Levente↗

Optimizing Individualized Treatment Planning for Parkinson’s Disease Using Deep Reinforcement Learning

More than one million people currently live with Parkinson's Disease (PD) in the U.S. alone. Medications, such as levodopa, can help manage PD symptoms. However, medication treatment planning is generally based on patient history and limited interaction between physicians and patients during office visits. This limits the extent of benefit that may be derived from the treatment as disease/patient characteristics are generally non-stationary. Wearable sensors that provide continuous monitoring of various symptoms, such as bradykinesia and dyskinesia, can enhance symptom management. However, using such data to overhaul the current static medication treatment planning approach and prescribe personalized medication timing and dosage that accounts for patient/care-giver/physician feedback/preferences remains an open question. We develop a model to prescribe timing and dosage of medications, given the motor fluctuation data collected using wearable sensors in real-time. We solve the resulting model using deep reinforcement learning (DRL). The prescribed policy determines the optimal treatment plan that minimizes patient's symptoms. Our results show that the model-prescribed policy outperforms the static a priori treatment plan in improving patients' symptoms, providing a proof-of-concept that DRL can augment medical decision making for treatment planning of chronic disease patients.

Watts, Jeremy↗

Thermo-Hydraulic-Mechanical Modelling of the Full-Scale Emplacement (FE) Experiment at the Mont Terri Rock Laboratory - 16490

The Full-Scale Emplacement Experiment at the Mont Terri underground research laboratory is a heater test carried out in a gallery constructed in Opalinus Clay. The aim of the experiment is both to develop emplacement procedures for radioactive waste canisters and their surrounding backfill as well as understanding the thermo-hydro-mechanical effects of disposing of radioactive waste on the engineering materials and the host rock. Coupled thermo-hydro-mechanical models have been used to aid planning of the locations of sensors, to inform decisions on the schedule for turning on the heaters as well as to make predictions of the temperatures and water pressures in the bentonite and the Opalinus Clay. The FE Experiment was preceded by a number of other experiments at the Mont Terri laboratory at smaller scales, but with similar materials, which provided crucial input to the models and gave confidence in the general process understanding. Blind predictions were made prior to turning on the heaters, of the temperature and relative humidity in the bentonite surrounding the heaters. The comparison between the blind predictions and early data from the experiment show that knowledge gained from smaller scale experiments on similar materials has enabled good blind predictions to be made and gives confidence that temperature in the experiment is unlikely to rise to a level that could damage the sensors. It also demonstrates that the thermal properties of the disposal system are understood well enough to produce reliable estimates of temperature in the backfill. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Techniques for controlling charging and/or discharging of batteries using a tanks-in-series model

In some embodiments, a battery management system is provided. The battery management system comprises a connector for electrically coupling a battery to the battery management system, at least one sensor configured to detect a battery state, a programmable chip configured to control at least one of charging and discharging of the battery, and a controller device. The controller device is configured to receive at least one battery state from the at least one sensor; provide the at least one battery state as input to a tanks-in-series model that represents the battery; and provide at least one output of the tanks-in-series model to the programmable chip for controlling at least one of charging and discharging of the battery.

25 ENERGY STORAGE↗

Sensor Development for Liquid Water Detection in Dry Storage Casks: FY 2023 Status

Modeling efforts were undertaken in fiscal year (FY) 2023 to evaluate the feasibility and capability for sensing of liquid water inside canister-based dry cask storage systems (DCSSs). The focus was on the development of full-scale finite element models (FEMs) of ultrasound propagation through DCSS canister components. For these initial investigations, simulation of the baseplate component was targeted, envisioning water collection at the bottom of a vertically oriented canister. The effects of internal canister components (i.e., fuel basket, fuel assemblies) on ultrasound propagation in the baseplate component were evaluated in these efforts. The environment inside a DCSS confinement is intended to be inert and free of water to prevent potential corrosion of used fuel cladding or other internal hardware. Spent fuel assemblies are dried, after storage in water pools, to make sure water has been removed from assembly cavities. However, there is some uncertainty about the amount of residual water potentially left behind in a DCSS after drying processes, because water can become trapped in cavities or other small crevices in the surfaces formed by the fuel cladding, fuel assemblies, and other internal hardware components. Considering the complex space- and time-dependent temperature profiles in DCSSs, water may be in a liquid or gas phase depending on its location in the cask and how long the cask has been in storage. Evacuating most water and oxidizing agents contained within a canister is recommended by NUREG-1536 (NRC 2010), which covers DCSSs. As summarized by Salazar et al. (2020), existing guidance typically relies on achievable vacuum pumping pressures sustained over a hold period as a signal of dryness and water removal. However, time series data about water removal from full-scale commercial drying procedures are lacking (Hanson and Alsaed 2019). A review of drying specifications from several vendors led to the conclusion that if the specifications are followed correctly, the residual moisture in DCSSs should present an insignificant risk of cladding degradation (Knoll and Gilbert 1987). A more recent analysis concluded that much larger quantities of residual water could remain in DCSSs, but the amount would still not be expected to lead to significant corrosion of fuel cladding or other internal components (Jung et al. 2013). Industry drying procedures are mostly prescriptive in nature, and operational issues arising during the process could result in incomplete drying. A summary of operational issues and potential negative effects of residual water is provided by Salazar et al. (2019). Experimental efforts are ongoing to validate the extent of water removal in a DCSS based on drying procedures used at nuclear power plants through well-designed investigations of drying process efficacy and water retention (Durbin et al. 2021; Pulido et al. 2022a, Pulido et al. 2022b). This has been approached by simulating limited portions of a DCSS internal volume and fuel assemblies. So far, these efforts have focused on the effects of potential water trapping in the dashpot region of control rod guide tubes but are expected to be expanded to include the effects of other internal hardware features and failed fuel rod cladding. A method for detection and measurement of liquid water (Meyer et al. 2022; Meyer et al. 2021), in tandem with the drying information gained through experimental investigations, provides comprehensive bases for understanding the internal conditions of DCSSs and provides technical information to support licensing decisions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation tool for optical design of PET detector modules including scintillator material and sensor array

The appearance of single photon avalanche diodes (SPADs) in the field of PET detector modules made it necessary to apply more complex optical design methods to refine the performance of such assemblies. We developed a combined simulation tool that is capable to model complex detector structures including scintillation material, light guide, light collection optics and sensor, correctly taking into account the statistical behavior of emission of scintillation light and its absorbance in SPADs. As a validation we compared simulation results obtained by our software and another optical design program. Calculations were performed for a simple PET detector arrangement used for testing purposes. According to the results, deviation of center of gravity coordinates between the two simulations is 0.0195 mm, the average ratio of total counts 1.0052. We investigated the error resulting from finite sampling in wavelength space and we found that 20 nm pitch is sufficient for the simulation in case of the given spectral dependencies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations for Planning of Liquid Hydrogen Spill Test

In order to better understand the complex pooling and vaporization of a liquid hydrogen spill, Sandia National Laboratories is conducting a highly instrumented, controlled experiment inside their Shock Tube Facility. Simulations were run before the experiment to help with the planning of experimental conditions, including sensor placement and cross wind velocity. This paper describes the modeling used in this planning process and its main conclusions. Sierra Suite’s Fuego, an in-house computational fluid dynamics code, was used to simulate a RANS model of a liquid hydrogen spill with five crosswind velocities: 0.45, 0.89, 1.34, 1.79, and 2.24 m/s. Two pool sizes were considered: a diameter of 0.85 m and a diameter of 1.7. A grid resolution study was completed on the smaller pool size with a 1.34 m/s crosswind. A comparison of the length and height of the plume of flammable hydrogen vaporizing from the pool shows that the plume becomes longer and remains closer to the ground with increasing wind speed. The plume reaches the top of the facility only in the 0.45 m/s case. From these results, we concluded that it will be best for the spacing and location of the concentration sensors to be reconfigured for each wind speed during the experiment.

08 HYDROGEN↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Advanced Manufactured Surface Acoustic Wave Sensor for Temperature Measurement in Nuclear Applications

As part of a collaborative effort between Idaho National Laboratory and the Boise State University, printed SAW transducers were developed. The transducers were first modelled and evaluated for optimum performance, then fabricated using several piezoelectric substrates. These printed SAW-sensors were tested for temperature sensing ability and found to be highly sensitive and with a very linear response over the tested range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MTL_TX: A Multi-Task Transformer Model for Improved Radiation Time-Series Estimation

Controlling radiation doses at potential radioactive facilities is critical to ensuring the safety of both personnel and the public. At the Thomas Jefferson National Accelerator Facility (JLab), multiple sensors are deployed around the three experimental halls to monitor key parameters, including single-beam current, energy levels, current leakage, and radiation values during accelerator operations. In this study, we developed a Multi-task Transformer model, MTL_TX, to accurately estimate radiation doses at sensor locations based on historical data, with the aim of enhancing safety in accelerator facilities and surrounding public areas. To improve estimation accuracy, we integrated two innovative components into the proposed model: hierarchical feature embedding (HFE) and multi-level decomposition attention (MDA). Additionally, the multi-task learning (MTL) framework effectively leverages correlations among multiple sensors, enabling individual estimations for each sensor. MTL_TX achieved outstanding results on data collected in 2018, with an MSE of 0.1464, an RMSE of 0.2353, and an R 2 score of 0.8584. Furthermore, when trained on 2018 data, MTL_TX exhibited excellent generalization capability to unseen datasets from 2016 to 2019, achieving an MSE of 0.1407, an RMSE of 0.2263, and an R 2 score of 0.8831. These results demonstrate a significant improvement over existing state-of-the-art models.

Transformer↗

Thermal conductivity of solid deuterium by the 3ω method

The thermal conductivity of solid D2 is measured by the 3ω method, in which a wire embedded in the medium serves as both a heater and a temperature sensor. Conductivity values are obtained by fitting experimental data with a two-dimensional model that calculates heat flow in both the axial and radial directions as a function of frequency. The model provides the thermal conductivity of D2 from the measurement of the 3ω voltage and published values of specific heat and density of D2 and of the sensor wire, and thermal conductivity values for the sensor wire. Data for D2 gas and liquid are obtained for comparison to solid D2. Conductivity values obtained for solid D2 range from 0.35 ± 0.01 W/(m K) at 18.6 K to 0.75 ± 0.02 W/(m K) at 13.4 K and are the same for normal and ortho D2. These values are acquired at lower temperatures than the 3ω method has previously been used for.

Gram, R. Q.↗

A digital twin solution for floating offshore wind turbines validated using a full-scale prototype

Abstract. In this work, we implement, verify, and validate a physics-based digital twin solution applied to a floating offshore wind turbine. The digital twin is validated using measurement data from the full-scale TetraSpar prototype. We focus on the estimation of the aerodynamic loads, wind speed, and section loads along the tower, with the aim of estimating the fatigue lifetime of the tower. Our digital twin solution integrates (1) a Kalman filter to estimate the structural states based on a linear model of the structure and measurements from the turbine, (2) an aerodynamic estimator, and (3) a physics-based virtual sensing procedure to obtain the loads along the tower. The digital twin relies on a set of measurements that are expected to be available on any existing wind turbine (power, pitch, rotor speed, and tower acceleration) and motion sensors that are likely to be standard measurements for a floating platform (inclinometers and GPS sensors). We explore two different pathways to obtain physics-based models: a suite of dedicated Python tools implemented as part of this work and the OpenFAST linearization feature. In our final version of the digital twin, we use components from both approaches. We perform different numerical experiments to verify the individual models of the digital twin. In this simulation realm, we obtain estimated damage equivalent loads of the tower fore–aft bending moment with an accuracy of approximately 5 % to 10 %. When comparing the digital twin estimations with the measurements from the TetraSpar prototype, the errors increased to 10 %–15 % on average. Overall, the accuracy of the results is promising and demonstrates the possibility of using digital twin solutions to estimate fatigue loads on floating offshore wind turbines. A natural continuation of this work would be to implement the monitoring and diagnostics aspect of the digital twin to inform operation and maintenance decisions. The digital twin solution is provided with examples as part of an open-source repository.

17 WIND ENERGY↗

Integration of a DER Management System in Riverside. Final report

The tasks in this project covered various aspects, including algorithm development, algorithm integration into a commercial Active Network Management (ANM) platform, hardware-in-the-loop (HIL) testing in an industry-standard testing platform, pilot demonstration in Riverside, California, and also cost and benefit analysis. The DERMS platform in this project can host different algorithms developed on different platforms (e.g., MATLAB and Python) and it can interact with different hardware devices (e.g., different PV inverters, battery inverters, and different sensors). The DER control solution are based on an advanced model-free, layered, and clustered DER control paradigm. At the core of the DER control algorithms was the concept of Extremum Seeking (ES), which is a model-free probing-based control technique. The ES-based control algorithms were tested on major real-world inverters; both individually and in a cluster. It was shown that even legacy equipment (or when paired with a few additional advanced equipment) can support such advanced control. The monitoring algorithms utilize a heterogeneous set of legacy and advanced sensor measurements, such as behind-the-meter DER sensors, distribution-level Phase Measurement Units, distribution-substation Supervisory Control and Data Acquisition (SCADA), and line current sensors, with their limited availability; in order to infer practical network conditions. Sensor data are utilized to achieve resource forecasting, phase identification, and distribution system state estimation. The technology that was developed and demonstrated in this project could be transformational to utilities, including the smaller municipal utilities such as in Riverside, which may not have the resources to deploy advanced distribution system and DERMS solutions in order to support high penetration of solar power integration. This project created a real-world prototype to provide utilities with an assessment of smart grid monitoring and control technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗