Search NASA⌕ Search

SEARCH · Search NASA

Results for “small sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Extraordinary role of Ce-Ni elements on the electrical and magnetic properties of Sr-Ba M-type hexaferrites

The structural, electrical and magnetic behavior of Sr{sub 0.5}Ba{sub 0.5-x}Ce{sub x}Fe{sub 12-y}Ni{sub y}O{sub 19} (where x = 0.00-0.10; y = 0.00-1.00) hexaferrite nanomaterials are reported in this paper. The structural analysis indicates that the Ce-Ni doped Sr-Ba M-type hexaferrite samples synthesized by the co-precipitation method are stoichiometric, single magnetoplumbite phase with crystallite sizes in the range of 35-48 nm. The dc-electrical resistivity of the pure Sr-Ba hexaferrite is enhanced to almost 10{sup 2} times by doping with Ce-Ni contents of x = 0.06; y = 0.60. The dielectric constant and dielectric loss tangent decrease to values {approx}14 and <0.2, respectively, by increasing the frequency up to 1 MHz. Small relaxation peaks at frequencies >10{sup 5} Hz are observed for the samples with Ce content of x > 0.06. The values of saturation magnetization increase from 66.32 to 84.33 emu/g and remanance magnetization from 42.64 to 56.01 emu/g but coercivity decreases from 2.85 to 1.59 kOe by substitution of Ce-Ni. Sharp ferri-paramagnetic transition is observed in the samples, which is confirmed by DSC results. Ce-Ni substitution acts to reduce the electron-hopping between Fe{sup 2+}/Fe{sup 3+} ions and also improves the magnetic properties. These characteristics are desirable for their possible use in microwave and chip devices.

36 MATERIALS SCIENCE↗

Pore-Scale and Multiscale Numerical Simulation of Flow and Transport in a Laboratory-Scale Column

Pore-scale models are useful for studying relationships between fundamental processes and phenomena at larger (i.e., Darcy) scales. However, the size of domains that can be simulated with explicit pore-scale resolution is limited by computational and observational constraints. Direct numerical simulation of pore-scale flow and transport is typically performed on millimeter-scale volumes at which X-ray computed tomography (XCT), often used to characterize pore geometry, can achieve micrometer resolution. In contrast, the scale at which a continuum approximation of a porous medium is valid is usually larger, on the order of centimeters to decimeters. Furthermore, laboratory experiments that measure continuum properties are typically performed on decimeter-scale columns. At this scale, XCT resolution is coarse (tens to hundreds of micrometers) and prohibits characterization of small pores and grains. We performed simulations of pore-scale processes over a decimeter-scale volume of natural porous media with a wide range of grain sizes, and compared to results of column experiments using the same sample. Simulations were conducted using high-performance codes executed on a supercomputer. Two approaches to XCT image segmentation were evaluated, a binary (pores and solids) segmentation and a ternary segmentation that resolved a third category (porous solids with pores smaller than the imaged resolution). We used a mixed Stokes-Darcy simulation method to simulate the combination of Stokes flow in large open pores and Darcy-like flow in porous solid regions. Simulations based on the ternary segmentation provided results that were consistent with experimental observations, demonstrating our ability to successfully model pore-scale flow over a column-scale domain.

CFD↗

Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic scintillator, attached to 10-20 m long optical fiber cables of plastic. During irradiation, each dosimeter probe spontaneously emits radioluminescence (RL) in proportion to the dose rate. The luminescence intensity can be detected with photomultiplier tubes, CCD cameras or other highly sensitive photodetectors. Some crystalline phosphors, such as carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal therefore reflects the passively integrated dose. In contrast to thermoluminescence dosimetry, fiber-coupled OSL dosimetry may be performed in vivo while the dosimeter is still in the patient. Within the last few years, several improvements and new applications of these techniques have been published, and the objective of this review is to provide an introduction to this field and to outline some of these new results. Emphasis will be given to applications in medical dosimetry such as in vivo real-time dose verification in brachytherapy and methods aimed for improved quality assurance of linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maraia Capsule Flight Testing and Results for Entry, Descent, and Landing

The Maraia concept is a modest size (150 lb., 30" diameter) capsule that has been proposed as an ISS based, mostly autonomous earth return capability to function either as an Entry, Descent, and Landing (EDL) technology test platform or as a small on-demand sample return vehicle. A flight test program has been completed including high altitude balloon testing of the proposed capsule shape, with the purpose of investigating aerodynamics and stability during the latter portion of the entry flight regime, along with demonstrating a potential recovery system. This paper includes description, objectives, and results from the test program.

Sostaric, Ronald R.↗

The Genesis Non-flight Implant Sample Archive

Introduction: For the past 20 years the Genesis science community has been analyzing solar wind captured in sample collectors now curated at Johnson Space Center (JSC). Non-flown flight like collector materials (non-flight) considered reference material was always allocated by the JSC Genesis team for testing experimental procedures. However, to expedite Genesis science, distribution of non-flown reference materials were also provided by, D. S. Burnett (Genesis PI, Caltech) and A. J. G. Jurewicz (ASU) who were funded to aid all Genesis PIs by providing engineering test materials archived at Caltech pre-flight as well as ion implants into these materials [1]. Implanted materials (non-flight reference, flight-like semiconductor materials, and NIST SRM glass) received from the Caltech collection during a pilot project are being used to develop an accession procedure for the purpose of making these materials available to researchers in the future. These implant samples are important because they can be utilized as measurement standards [2]. This is a work in progress and this work reports progress in documentation and imaging. The pilot program received 63 implanted reference materials with known implanted ions. Genesis Non-Flight Database: The existing non-flight material database was modified to allow for the description of implant sessions and to allow correlation of the implant information to individual specimens. An implant session has three main components: a known ion, a known dose (ion/cm2), and a known energy (keV). Procedure: Laboratory Procedure. Upon receiving non-flight analytical standards (independently calibrated implants), or implant samples (nominally calibrated implants), they will be imaged in their current containers to capture any information written before being brought into the Genesis Sample Laboratory. Documentation is provided by the donor and used for correlating the data between the implant sessions and implant samples. This information is not verified by Genesis Curation. The microscope used to image samples in the laboratory has an automated stage with a stainless-steel plate to hold samples and a camera that utilizes the software Surveyor to take photomosaic images of the implant samples. The camera attached to the microscope is a QICAM High Performance IEEE 1394 FireWire Digital CCD Camera. This setup, shown in Fig. 1, allows for photomosaics of small-scale samples with a 10x objective or 25x objective. Examples of images taken with this microscope setup are shown in Fig.2 and Fig. 3. After imaging, samples get stored in a clean fluoroware container or polypropylene vial depending on sample size for long term storage. Database Procedure. The Genesis Non-Flight Database currently allows for the addition of implant sessions. The required fields for adding an implant session are the implant session ion, the implant session dose, and the implant session energy. There are also fields for the date and vendor of the sessions as well as a field for if the session was calibrated or not. Once an implant session has been inserted into the database, additional documentation from the session can be attached. The database will automatically assign an Implant Session Number. After inserting an implant session, the implanted samples can be inserted. The fields required for an implant sample are the material of the sample and the size of the sample. The Generic name for the implant sample with be automatically generated by the database once it has been inserted. Implant sample numbers begin with 3X to distinguish from flown Genesis sample numbers. There are also fields for processors to add the location (room, cabinet, tray) and container type (fluoroware, polypropylene vial). Once an implant session and an associated sample(s) have been inserted into the database the sample can be then tied to all associated implant sessions. An implant sample can be tied to multiple implant sessions. Future work: For curation, future work consists of creating an online catalogue for implant samples as well as updating the database with more samples as we receive them. For the scientific community these implant samples have many potential uses. For Genesis research, they are directly applicable for testing and, in some cases, as analytical standards. For non-Genesis research, implants (especially calibrated implants) could be used for calibrating other, unique planetary materials [1].

C D Calva↗

Dispersed SiC nanoparticles in Ni observed by ultra-small-angle X-ray scattering

In this paper, a metal-ceramic composite, nickel reinforced with SiC nanoparticles, was synthesized and characterized for its potential application in next-generation molten salt nuclear reactors. Synchrotron ultra-small-angle X-ray scattering (USAXS) measurements were conducted on the composite. The size distribution and number density of the SiC nanoparticles in the material were obtained through data modelling. Scanning and transmission electron microscopy characterization were performed to substantiate the results of the USAXS measurements. Tensile tests were performed on the samples to measure the change in their yield strength after doping with the nanoparticles. Finally, the average interparticle distance was calculated from the USAXS results and is related to the increased yield strength of the composite.

36 MATERIALS SCIENCE↗

Electron spectroscopy for chemical analysis: Sample analysis

Exposure conditions in atomic oxygen (ESCA) was performed on an SSL-100/206 Small Spot Spectrometer. All data were taken with the use of a low voltage electron flood gun and a charge neutralization screen to minimize charging effects on the data. The X-ray spot size and electron flood gun voltage used are recorded on the individual spectra as are the instrumental resolutions. Two types of spectra were obtained for each specimen: (1) general surveys, and (2) high resolution spectra. The two types of data reduction performed are: (1) semiquantitative compositional analysis, and (2) peak fitting. The materials analyzed are: (1) kapton 4, 5, and 6, (2) HDPE 19, 20, and 21, and (3) PVDF 4, 5, and 6.

Carter, W. B.↗

Axisymmetric and Focusing Analyzers to Enable Efficient Powder and Residual Stress Neutron Diffractometers

Project Summary: Company: Adelphi Technology, Inc., Redwood City, CA 94063-4121 DOE Phase 1 STTR PI: Dr. Jay Theodore Cremer, Jr. Chief Scientist at Adelphi Technology, Inc. DOE Phase 1 STTR with: Dr. Boris Khaykovich of Massachusetts Institute of Technology (MIT) MIT Nuclear Reactor Laboratory DOE Phase 1 STTR Title: Axisymmetric and Focusing Analyzers to Enable Efficient Powder and Residual Stress Neutron Diffractometers Statement of the problem or situation that is being addressed: Although thermal and cold neutron scattering is widely used, and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed, so as to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed: We strive to achieve the goal of efficient use of available thermal and cold neutrons, by introducing here, novel analyzers for powder diffraction and stress-strain measurements. These analyzers will enable polychromatic cold and thermal neutron diffractometers, which will have much higher throughput than existing instruments. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast instruments for screening of multiple samples, for measuring kinetic processes, or for measuring residual stress tensors. Commercial Applications and Other Benefits: By combining the novel analyzers with the Adelphi thermal neutron generator, we will open a new market, which includes the testing of samples that cannot be transported, such as nuclear fuels, or the testing of parts during production. Given the reasonable cost and size of our proposed analyzer systems, along with the continuing development of more powerful thermal neutron generators, the proposed analyzers will be suitable for weak neutrons sources, which are installed at small to large university, industrial, and government laboratories. Key Words: Neutron powder diffraction, residual stress measurements, thermal neutron generators, TRIGA reactors, low flux thermal and cold neutron sources, neutron diffraction. Summary for Members of Congress: Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of the tribological properties of fluorinated cokes and graphites

The friction, wear, endurance life, and surface morphology of rubbed (burnished) fluorinated graphite and fluorinated coke materials were studied. Two different coke powders, a graphitic carbon powder, and a graphite powder were fluorinated and then tribologically investigated. In addition, one of the coke powders was reduced in size before fluorinating to evaluate the effect of a finer particle size on the tribological properties. For comparison, graphite and coke powders which were not fluorinated were also tribologically evaluated. Elemental analysis by emission spectroscopy was performed on each sample to determine the impurity content and X-ray diffraction analysis was performed to determine the crystallinity. Coke was found to have very little lubricating ability, but fluorinated coke did possess good lubricating properties. However, the fluorinated graphite and fluorinated graphitic carbon (which gave equivalent results) gave superior results to those obtained with the fluorinated cokes. No tribological benefit was found for using small versus a larger particle size of coke, at least when evaluated as a rubbed film.

Fusaro, Robert L.↗

Comparison of the tribological properties of fluorinated cokes and graphites

The friction, wear, endurance life, and surface morphology of rubbed (burnished) fluorinated graphite and fluorinated coke materials were studied. Two different coke powders, a graphitic carbon powder, and a graphite powder were fluorinated and then tribologically investigated. In addition, one of the coke powders was reduced in size before fluorinating to evaluate the effect of a finer particle size on the tribological properties. For comparison, graphite and coke powders which were not fluorinated were also tribologically evaluated. Elemental analysis by emission spectroscopy was performed on each sample to determine the impurity content and X-ray diffraction analysis was performed to determine the crystallinity. Coke was found to have very little lubricating ability, but fluorinated coke did possess good lubricating properties. However, the fluorinated graphite and fluorinated graphitic carbon (which gave equivalent results) gave superior results to those obtained with the fluorinated cokes. No tribological benefit was found for using small versus a larger particle size of coke, at least when evaluated as a rubbed film.

Fusaro, Robert L.↗

Aerosols in polluted versus nonpolluted air masses Long-range transport and effects on clouds

To assess the influence of anthropogenic aerosols on the physics and chemistry of clouds in the northeastern United States, aerosol and cloud-drop size distributions, elemental composition of aerosols as a function of size, and ionic content of cloud water were measured on Whiteface Mountain, NY, during the summers of 1981 and 1982. In several case studies, the data were cross-correlated with different air mass types - background continental, polluted continental, and maritime - that were advected to the sampling site. The results are the following: (1) Anthropogenic sources hundreds of kilometers upwind cause the small-particle (accumulation) mode number to increase from hundreds of thousands per cubic centimeter and the mass loading to increase from a few to several tens of micrograms per cubic meter, mostly in the form of sulfur aerosols. (2) A significant fraction of anthropogenic sulfur appears to act as cloud condensation nuclei (CCN) to affect the cloud drop concentration. (3) Clouds in Atlantic maritime air masses have cloud drop spectra that are markedly different from those measured in continental clouds. The drop concentration is significantly lower, and the drop size spectra are heavily skewed toward large drops. (4) Effects of anthropogenic pollutants on cloud water ionic composition are an increase of nitrate by a factor of 50, an increase of sulfate by more than one order of magnitude, and an increase of ammonium ion by a factor of 7. The net effect of the changes in ionic concentrations is an increase in cloud water acidity. An anion deficit even in maritime clouds suggests an unknown, possibly biogenic, source that could be responsible for a pH below neutral, which is frequently observed in nonpolluted clouds.

Pueschel, R. F.↗

Synthesis and morphological characterization of linear and miktoarm star poly(solketal methacrylate)- block -polystyrene copolymers

The synthesis, molecular characterization, and morphological evaluation of AB n, (n = 2,3) miktoarm star block copolymers consisting of poly(glycerol monomethacrylate) (PGMA) and polystyrene (PS) with varying molecular weights and compositions is described. The system is known to demonstrate a remarkably high Flory-Huggins interaction parameter. The corresponding linear diblock copolymer analogues, were synthesized as well, and comparisons with regard to feature dimensions and morphologies are provided. Well-ordered nanostructures of various morphologies were formed with domain spacing as low as 7.2 nm. Different morphologies were attained by some of the topological isomers indicating that in miktoarm star block copolymers the phase boundaries were strongly shifted. Additionally, a triblock ABA analogue was studied to investigate the effect of triblock copolymer conformations. Noteworthy is that for copolymers with different macromolecular architecture leading to similar morphology; different domain spacings were obtained. The synthesis of all the samples was carried out by high-vacuum anionic polymerization techniques. Molecular characterization with Size Exclusion Chromatography (SEC) and Proton Nuclear Magnetic Resonance Spectroscopy ( 1 H NMR) confirmed well-defined copolymers obtained. The morphological characterization was accomplished by Small-Angle X-ray Scattering (SAXS). In conclusion, the observations from this study highlight the potential of incorporating macromolecular architecture in the self-assembly of strongly immiscible block copolymers to attain ultra-small nanofeatures with desired morphologies.

36 MATERIALS SCIENCE↗

Nanoporous Thermosets with Percolating Pores from Block Polymers Chemically Fixed above the Order–Disorder Transition

A lamellar diblock polymer combining a cross-linkable segment with a chemically etchable segment was cross-linked above its order–disorder temperature (TODT) to kinetically trap the morphology associated with the fluctuating disordered state. After removal of the etchable block, evaluation of the resulting porous thermoset allows for an unprecedented experimental characterization of the trapped disordered phase. Through a combination of small-angle X-ray scattering, nitrogen sorption, scanning electron microscopy, and electron tomography experiments we demonstrate that the nanoporous structure exhibits a narrow pore size distribution and a high surface to volume ratio and is bicontinuous over a large sample area. Together with the processability of the polymeric starting material, the proposed system combines attractive attributes for many advanced applications. In particular, it was used to design new composite membranes for the ultrafiltration of water.

36 MATERIALS SCIENCE↗

Research & Development on Superconducting Niobium Materials via Magnetic Measurements

We present a study of superconducting properties of both large grain (1 mm average grain size) and small grain (50 micron average grain size) Niobium materials containing varying amounts of Tantalum impurities that have been used in the fabrication of high accelerating gradient superconducting radio frequency cavities. We found that a buffered chemical polishing of these Niobium samples causes a distinct reduction in the superconducting parameters like TC, wt- ppm to 1300 wt-ppm. Implications of these results on the performance of niobium superconducting radio frequency cavities are discussed, especially the anomalous high field RF losses that have been reported in the literature.

36 MATERIALS SCIENCE↗

Kinetics of linear domains in LiNbO{sub 3} single crystals polarized by scanning probe microscopy

Growth and decay processes of linear domains in lithium niobate single crystals fabricated utilizing scanning probe microscopy were investigated. It is found that the initial configuration of linear domains is dependent on the fabrication parameters as scan velocity and voltage. The linear domains decay at the part where the domain width is small for two different processes. A comparison of critical stable domain size between dot and linear domains was carried out. The critical linear domain width is 0.7 times as large as the critical diameter of dot domain at the same sample thickness due to their smaller surface energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High resolution coherent diffractive imaging with a table-top extreme ultraviolet source

We demonstrate a resolution of 45 nm with a sample size down to 3 μm × 3 μm is achieved in a short exposure time of 2 s, from the diffraction pattern generated by a table-top high harmonic source at around 30 nm. By using a narrow-bandwidth focusing mirror, the diffraction pattern's quality is improved and the required exposure time is significantly reduced. In order to obtain a high quality of the reconstructed image, the ratio of the beam size to the sample size and the curvature of the focused beam need to be considered in the reconstruction process. This new experimental scheme is very promising for imaging sub-10 nm scale objects with a table-top source based on a small inexpensive femtosecond laser system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗