Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Quantitative metrics for assessment of chemical image quality and spatial resolution

Rationale: Currently objective/quantitative descriptions of the quality and spatial resolution of mass spectrometry derived chemical images are not standardized. Development of these standardized metrics is required to objectively describe chemical imaging capabilities of existing and/or new mass spectrometry imaging technologies. Such metrics would allow unbiased judgment of intra-laboratory advancement and/or inter-laboratory comparison for these technologies if used together with standardized surfaces. Methods: We developed two image metrics, viz., chemical image contrast (ChemIC) based on signal-to-noise related statistical measures on chemical image pixels and corrected resolving power factor (cRPF) constructed from statistical analysis of mass-to-charge chronograms across features of interest in an image. These metrics, quantifying chemical image quality and spatial resolution, respectively, were used to evaluate chemical images of a model photoresist patterned surface collected using a laser ablation/liquid vortex capture mass spectrometry imaging system under different instrument operational parameters. Results: The calculated ChemIC and cRPF metrics determined in an unbiased fashion the relative ranking of chemical image quality obtained with the laser ablation/liquid vortex capture mass spectrometry imaging system. These rankings were used to show that both chemical image contrast and spatial resolution deteriorated with increasing surface scan speed, increased lane spacing and decreasing size of surface features. Conclusions: ChemIC and cRPF, respectively, were developed and successfully applied for the objective description of chemical image quality and spatial resolution of chemical images collected from model surfaces using a laser ablation/liquid vortex capture mass spectrometry imaging system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evidence of Directional Structural Superlubricity and Lévy Flights in a van der Waals Heterostructure

Abstract Structural superlubricity is a special frictionless contact in which two crystals are in incommensurate arrangement such that relative in‐plane translation is associated with vanishing energy barrier crossing. So far, it has been realized in multilayer graphene and other van der Waals (2D crystals with hexagonal or triangular crystalline symmetries, leading to isotropic frictionless contacts. Directional structural superlubricity, to date unrealized in 2D systems, is possible when the reciprocal lattices of the two crystals coincide in one direction only. Here, directional structural superlubricity a α‐bismuthene/graphite van der Waals system is evidenced, manifested by spontaneous hopping of the islands over hundreds of nanometers at room temperature, resolved by low‐energy electron microscopy and supported by registry simulations. Statistical analysis of individual and collective α‐bismuthene islands populations reveal a heavy‐tailed distribution of the hopping lengths and sticking times indicative of Lévy flight dynamics, largely unobserved in condensed‐matter systems.

Le Ster, Maxime↗

Safety Design of Water Infrastructures in A Modern Era

In this chapter, we review the current practice of engineering safety design of large water management infrastructures. Those large infrastructures are designed using probable maximum precipitation (PMP) to withstand extreme conditions, but climate change has been posing challenges on the conventional PMP estimation approach. We discuss multiple limitations of the current approaches, and propose a few possible solutions based on the advancement of atmospheric modeling and statistical analysis of extreme precipitation mechanisms.

Chen, Xiaodong↗

Porting Adaptive Ensemble Molecular Dynamics Workflows to the Summit Supercomputer

Molecular dynamics (MD) simulations must take very small (femtosecond) integration steps in simulation-time to avoid numerical errors. Efficient use of parallel programming models and accelerators in state-of-the art MD programs now is pushing Moore’s limit for time-per-MD step. As a result, directly simulating timescales beyond milliseconds will not be attainable directly, even at exascale. However, concepts from statistical physics can be used to combine many parallel simulations to provide information about longer timescales and to adequately sample the simulation space, while preserving details about the dynamics of the system. Implementing such an approach requires a workflow program that allows adaptable steering of task assignments based on extensive statistical analysis of intermediate results. Here we report the implementation of such an adaptable workflow program to drive simulations on the Summit IBM Power System AC922, a pre-exascale supercomputer at the Oak Ridge Leadership Computing Facility (OLCF). We compare to experiences on Titan, Summit’s predecessor, report the performance of the workflow and its components, and describe the porting process. We find that using a workflow program managed by a Mongo database can provide the fault tolerance, scalable performance, task dispatch rate, and reconfigurability required for robust and portable implementation of ensemble simulations such as are used in enhanced-sampling molecular dynamics. This type of workflow generator can also be used to provide adaptive steering of ensemble simulations for other applications in addition to MD.

Ossyra, John R.↗

Vacuum structure of the left-right symmetric model

The left-right symmetric model (LRSM), originally proposed to explain parity violation in low energy processes, has since emerged as an attractive framework for light neutrino masses via the seesaw mechanism. The scalar sector of the minimal LRSM consists of an SU(2) bi-doublet, as well as left- and right-handed weak isospin triplets, thus making the corresponding vacuum structure much more complicated than that of the Standard Model. In particular, the desired ground state of the Higgs potential should be a charge conserving, and preferably global, minimum with parity violation at low scales. We show that this is not a generic feature of the LRSM potential and happens only for a small fraction of the parameter space of the potential. We also analytically study the potential for some simplified cases and obtain sufficient conditions (though not necessary) to achieve successful symmetry breaking. We then carry out a detailed statistical analysis of the minima of the Higgs potential using numerical minimization and find that for a large fraction of the parameter space, the potential does not have a good vacuum. Imposing the analytically obtained conditions, we can readily find the small part of the parameter space with good vacua. Consequences for some scalar masses are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Current and future constraints on Higgs couplings in the nonlinear Effective Theory

Here, we perform a Bayesian statistical analysis of the constraints on the nonlinear Effective Theory given by the Higgs electroweak chiral Lagrangian. We obtain bounds on the effective coefficients entering in Higgs observables at the leading order, using all available Higgs-boson signal strengths from the LHC runs 1 and 2. Using a prior dependence study of the solutions, we discuss the results within the context of natural-sized Wilson coefficients. We further study the expected sensitivities to the different Wilson coefficients at various possible future colliders. Finally, we interpret our results in terms of some minimal composite Higgs models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Combination of searches for heavy vector boson resonances in proton-proton collisions at $\sqrt{s}=13$ TeV

A combined statistical analysis of searches for heavy vector boson resonances decaying into pairs of W, Z, or Higgs bosons, as well as into quark pairs $\left(\mathrm{q}\overline{\mathrm{q}},\mathrm{b}\overline{\mathrm{b}},\mathrm{t}\overline{\mathrm{t}},\mathrm{t}\overline{\mathrm{b}}\right)$ or lepton pairs ℓ + ℓ – , ℓ$\bar{v}$, with ℓ = e, μ, τ, is presented. The results are based on proton-proton collision data at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 138 fb −1 , collected by the CMS experiment from 2016 to 2018. No significant deviation from the expectations of the standard model is observed. The results are interpreted in the simplified heavy vector triplet (HVT) framework, setting 95% confidence level upper limits on the production cross sections and on the coupling strengths of the HVT bosons to standard model particles. The results exclude HVT resonances with masses below 5.5 TeV in a weakly coupled scenario, below 4.8 TeV in a strongly coupled scenario, and up to 2.0 TeV in the case of production via vector boson fusion. The combination provides the most stringent constraints to date on new phenomena predicted by the HVT model.

beyond Standard Model↗

High-resolution time-of-flight mass spectrometry fingerprinting of metabolites from cecum and distal colon contents of rats fed resistant starch

Time-of-flight mass spectrometry along with statistical analysis was utilized to study metabolic profiles among rats fed resistant starch (RS) diets. Fischer 344 rats were fed four starch diets consisting of 55 % (w/w, dbs) starch. A control starch diet consisting of corn starch was compared against three RS diets. The RS diets were high-amylose corn starch (HA7), HA7 chemically modified with octenyl succinic anhydride, and stearic-acid-complexed HA7 starch. A subgroup received antibiotic treatment to determine if perturbations in the gut microbiome were long lasting. A second subgroup was treated with azoxymethane (AOM), a carcinogen. At the end of the 8-week study, cecal and distal colon content samples were collected from the sacrificed rats. Metabolites were extracted from cecal and distal colon samples into acetonitrile. The extracts were then analyzed on an accurate-mass time-of-flight mass spectrometer to obtain their metabolic profile. The data were analyzed using partial least-squares discriminant analysis (PLS-DA). The PLS-DA analysis utilized a training set and verification set to classify samples within diet and treatment groups. PLS-DA could reliably differentiate the diet treatments for both cecal and distal colon samples. The PLS-DA analyses of the antibiotic and no antibiotic-treated subgroups were well classified for cecal samples and modestly separated for distal colon samples. PLS-DA analysis had limited success separating distal colon samples for rats given AOM from those not treated; the cecal samples from AOM had very poor classification. Mass spectrometry profiling coupled with PLS-DA can readily classify metabolite differences among rats given RS diets.

36 MATERIALS SCIENCE↗

Retrospective comparison of outcomes and associated complications between large bore radiologically inserted gastrostomy tube types

Purpose: Multiple approaches to radiologically inserted gastrostomy (RIG) exist. The goal of this study was to compare 30-day outcomes and associated complications between large bore balloon-retained (BR), loop-retained (LR), and pull-type (PT) RIG devices. Methods: Data on 1477 patients who underwent RIG between January 1, 2005 and December 31, 2016 were collected retrospectively using a dedicated interventional radiology database and electronic medical record. Statistical analysis was performed to compare complication rates between BR, LR, and PT devices. Results: Ninety-eight percent (1477/1507) of the procedures were successfully performed. A total of 752 BR, 323 LR, and 402 PT gastrostomy tubes were placed. The overall complication rate for BR catheters was 5.7% (25 major [3.3%] and 18 minor [2.4%]). The overall complication rate for PT catheters was 3.7% (8 major [2.0%] and 7 minor [1.7%]). The overall complication rate for LR catheters was 1.6% (4 major [1.4%] and 1 minor [0.8%]). Compared to BR catheters, LR catheters had significantly fewer total complications (P = 0.01) but not minor complications (P = 0.052). There were no significant differences in the number of complications between LR and PT catheters or between BR and PT catheters. Conclusions: Use of BR, LR, and PT devices for RIG is safe with a low incidence of complications. Compared to BR catheters, primary insertion of a LR gastrostomy was associated with significantly fewer overall complications within the first 30 days. Therefore, for initial tube placement, large bore LR catheters may be preferred over BR devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of fat and skeletal muscle tissue at abdominal computed tomography: associations between single-slice measurements and total compartment volumes

Purpose: Body composition is of great prognostic value in several severe diseases, including different types of cancer as well as cardiometabolic disorders. We aimed to investigate the correlations of skeletal muscle mass and abdominal adipose tissue compartments between volumetric and single-slice measurements to study the usefulness of several anatomical landmarks for estimation of total compartment volumes using abdominal CT-scans. Methods: In this retrospective study volumetric quantifications of paraspinal skeletal muscles (SM) and adipose tissue compartments (visceral adipose tissue, VAT; subcutaneous adipose tissue, SAT) were performed in 50 consecutive patients (26 male; mean age, 63 ± 15 years) who underwent abdominal multislice-CT for diagnostic purposes using an in-house software. Associations between total volumes of SM, VAT, and SAT with single-slice measurements at eight predefined anatomical landmarks (median intervertebral disk spaces T12/L1 to L5/S1; level of the umbilicus (U); level of the radix of the superior mesenteric artery (SMA)) were studied using correlation coefficients. Results: Statistical analysis revealed a strong association between single-slice measurements of adipose tissue compartments with total VAT and SAT volume (VAT: all r > 0.89, P < 0.001; SAT: all r > 0.95, P < 0.001). The strongest associations with total SM volume were found for single-slice measurements obtained at L3/4 (r = 0.94, P < 0.001) and were further improved by normalization to height (r = 0.98, P < 0.001). Conclusions: Single-slice measurements of SM, VAT, and SAT at several anatomical landmarks are strongly associated with total compartment volumes and therefore allow for easy and simultaneous assessment of skeletal muscle mass and adipose tissue compartment volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

110 Patients with adenosquamous carcinomas of the pancreas (PASC): imaging differentiation of small (≤ 3 cm) versus large (> 3 cm) tumors

Objective: This study examined radiological imaging features of small (≤ 3 cm) and large (> 3 cm) adenosquamous carcinomas of the pancreas (PASC) lesions to better understand the morphology of these lesions. Methods: Images from 110 patients with pathologically proven PASC (80 males and 30 females, mean age: 62.6 years) were retrospectively reviewed. Two radiologists analyzed images and reached a consensus regarding the following features: location, shape, margins, presence of solid and necrotic components, rim enhancement, density/intensity during the portal venous phase, invasion of surrounding organs, vascular invasion, venous tumor thrombus formation, and enlarged lymph nodes. Differences in the imaging features between the two groups were evaluated with the Chi-square test or Fisher’s exact test. Results: There were 41 small PASC lesions (mean age: 60.59 years) and 69 large PASC lesions (63.74 years). Statistical analysis demonstrated significant differences in the location, shape, adjacent organ and vessel invasion, and venous tumor thrombus formation (P < 0.05). Small PASC lesions were more frequently detected in the pancreatic head and had an ovoid shape. There was no significant difference in the presence of solid and necrotic components (P = 0.090), including approximately 3/4 of the lesions with necrosis and 1/4 purely solid lesions, enlarged lymph nodes (P = 0.068) and other features. Conclusion: Regardless of the tumor size, 75% of PASC lesions present with central necrosis while 25% are purely solid. Small PASC lesions can be associated with lymph node metastasis at a relatively early stage. Large PASC lesions are likely to invade adjacent tissues and be associated with venous tumor thrombus formation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy, criteria, and clinical significance of visual assessment on diffusion-weighted imaging and apparent diffusion coefficient quantification for diagnosing acute appendicitis

Purpose: To assess the accuracy, criteria, and clinical significance of diffusion-weighted imaging (DWI) signal intensity and apparent diffusion coefficient (ADC) quantification for diagnosing acute appendicitis. Methods: Fifty-one patients with right lower abdominal pain [uncomplicated appendicitis (n = 25), complicated appendicitis (n = 10), and non-appendicitis (n = 16)] who underwent MR examination were enrolled in this retrospective study. Two radiologists independently measured appendiceal diameter and wall thickness. They assessed whether a wall defect, an abscess, extraluminal air, or an appendicolith was present on axial T2WI; evaluated intensity on DWI using a 5-point scale; and determined the ADC values of the appendix and peri-appendiceal tissue. Statistical analysis was performed to assess imaging findings for the diagnosis of appendicitis and complicated appendicitis. Cut-off values were determined using receiver operating characteristic analysis. Results: For diagnosing acute appendicitis, the accuracy improved from 78.4% using only T2WI to 86.3% using combined T2WI and DWI for reader 1 and from 82.4 to 86.3% for reader 2. For the appendix, the cut-off ADC values that diagnosed appendicitis were 1.41 × 10{sup −3} and 1.26 × 10{sup −3} mm{sup 2}/s with accuracies of 78.4% and 76.5%, respectively. For the peri-appendiceal tissue, these values of 1.03 × 10{sup −3} and 0.91 × 10{sup −3} mm{sup 2}/s differentiated between uncomplicated and complicated appendicitis with an accuracy of 97.1%. Conclusions: Combined DWI and T2WI provided high accuracy for diagnosing appendicitis. The inflamed appendix had lower ADC value than the normal appendix. The peri-appendiceal tissue presenting low ADC value was a notable finding of complicated appendicitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the Occupational Doses of Interventional Radiologists

The aim of the present study was to determine whether there is a linear relation between the doses measured above and those measured under the lead apron of the radiologists performing interventional procedures. To monitor radiation exposure the International Commission of Radiological Protection (ICRP) recommends the use of a single dosimeter under the protective apron. To determine the exposure more accurately an additional dosimeter is recommended above the protective apron. The exposure of eight radiologists was monitored with two personal dosimeters during 3 consecutive years. To measure the doses uniformly the two dosimeters were worn in a special holder attached to the lead apron. The two personal dosimeters were replaced every 4 weeks on the same day. The doses above and under the protective aprons of seven radiologists did not differ significantly. A significant lower dose above and under the protective apron was measured for one of the radiologists. During a 4-week period the average dose measured above the lead apron was 3.44 mSv (median, 3.05 mSv), while that under the 0.25-mm lead apron was 0.12 mSv (median, 0.1 mSv). The coefficients of the regression line result in the equation Y = 0.036X - 0.004, with Y as the dose under the lead apron and X as the dose above the lead apron. The statistical analysis of the data established a linear relation between the doses above and those under the lead apron (R{sup 2} = 0.59). Before the special holder was introduced it was not possible to derive a relation between the doses above and those under the lead apron, as the doses were measured at varying places above and under the lead apron. There is no evidence that the effective dose can be estimated more accurately when an additional dosimeter is used. The present study revealed a threshold before doses under the lead apron were measured. Due to the threshold it can be concluded that the doses under the lead apron will not be underestimated easily when doses above the lead apron are used to calculate them. This is not the case when the doses above the lead apron are calculated for the doses under the lead apron.

61 RADIATION PROTECTION AND DOSIMETRY↗

Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval

The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavography detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Platinum-Fibered Microcoils with the Amplatzer Vascular Plug II

The Amplatzer Vascular Plug II (AVP II) is a novel device for transcatheter vessel occlusion, for which only limited comparative data exist. Embolotherapy of the gastroduodenal artery (GDA) is essential before internal radiotherapy (SIRT) in order to prevent radiation-induced peptic ulcerations due to migration of yttrium-90 microspheres. The purpose of this study was to compare the vascular anatomical limitations, procedure time, effectiveness, and safety of embolization of the GDA with coils versus the AVP II. Fifty patients stratified for SIRT were prospectively randomized for embolization of the GDA with either coils or the AVP II. The angle between the aorta and the celiac trunk, diameter of the GDA, fluoroscopy time and total time for embolization, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography for SIRT were recorded. A t-test was used for statistical analysis. Embolizations with either coils or the AVP II were technically feasible in all but two patients scheduled for embolization of the GDA with the AVP II. In both cases the plug could not be positioned due to the small celiac trunk outlet angles of 17{sup o} and 21{sup o}. The mean diameter of the GDA was 3.7 mm (range, 2.2-4.8 mm) for both groups. The procedures differed significantly in fluoroscopy time (7.8 min for coils vs. 2.6 min for the AVP II; P < 0.001) and embolization time (23.1 min for coils vs. 8.8 min for the AVP II; P < 0.001). A mean of 6.0 {+-} 3.2 coils were used for GDA embolization, while no more than one AVP II was needed for successful vessel occlusion (P < 0.001). One coil migration occurred during coil embolization, whereas no procedural complication was encountered with the use of the AVP II. Vessel reperfusion was noted in only one patient, in whom coil embolization was performed. In conclusion, embolization of the GDA with the AVP II is safe, easy, rapid, and highly effective; only an extremely sharp-angled celiac trunk outlet represented an anatomical limitation for device deployment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy and Safety of Two Different n-Butyl-2-Cyanoacrylates for the Embolization of Varicoceles: A Prospective, Randomized, Blinded Study

Purpose: This was a prospective, randomized, blinded comparative study of the efficacy and safety of two different n-butyl-2-cyanoacrylates (NBCAs) for embolization of varicoceles. Methods: A total of 112 insufficient spermatic veins (left-sided, n = 84; right-sided, n = 28) that were diagnosed in 83 adult males were prospectively randomized for blinded embolization with NBCA (n = 54; Histoacryl, Braun, Germany) or NBCA-MS (n = 58; Glubran2, General Enterprise Marketing, Viareggio, Lucca, Italy). Handling, embolic efficacy, and safety of both NBCAs were compared according the fulfillment of a standardized embolization plan, the occlusive effect on the spermatic vein, and the sticking to the microcatheter. Statistical analysis was performed with the Mann-Whitney U test and the Fisher's exact test. Results: Patients of both study arms were comparable for age and clinical indication. Spermatic vein characteristics were comparable for varicocele classification and embolization side. Both NBCAs were equally efficient in occluding the spermatic vein and blocking reflux (NBCA, n = 54/54, 100% vs. NBCA-MS, n = 54/57, 94.7%; P = 0.244). The embolization plan could be accomplished in an equal number of veins for both groups (NBCA, n = 45/54, 83.3% vs. NBCA-MS, n = 41/58, 70.7%; P = 0.124). Adhesiveness of the glue to the microcatheter was the same in both NBCA groups (NBCA, n = 25/54, 46.3% vs. NBCA-MS, n = 29/58, 50%; P = 0.71). No glue-related complications were noted. Conclusions: NBCA and NBCA-MS are equally efficient and safe glues for embolization of varicoceles.

61 RADIATION PROTECTION AND DOSIMETRY↗

Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable rate of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

US-Guided Femoral and Sciatic Nerve Blocks for Analgesia During Endovenous Laser Ablation

Endovenous laser ablation may be associated with significant pain when performed under standard local tumescent anesthesia. The purpose of this study was to investigate the efficacy of femoral and sciatic nerve blocks for analgesia during endovenous ablation in patients with lower extremity venous insufficiency. During a 28-month period, ultrasound-guided femoral or sciatic nerve blocks were performed to provide analgesia during endovenous laser ablation in 506 legs and 307 patients. The femoral block (n = 402) was performed at the level of the inguinal ligament, and the sciatic block at the posterior midthigh (n = 124), by injecting a diluted lidocaine solution under ultrasound guidance. After the blocks, endovenous laser ablations and other treatments (phlebectomy or foam sclerotherapy) were performed in the standard fashion. After the procedures, a visual analogue pain scale (1-10) was used for pain assessment. After the blocks, pain scores were 0 or 1 (no pain) in 240 legs, 2 or 3 (uncomfortable) in 225 legs, and 4 or 5 (annoying) in 41 legs. Patients never experienced any pain higher than score 5. The statistical analysis revealed no significant difference between the pain scores of the right leg versus the left leg (p = 0.321) and between the pain scores after the femoral versus sciatic block (p = 0.7). Ultrasound-guided femoral and sciatic nerve blocks may provide considerable reduction of pain during endovenous laser and other treatments, such as ambulatory phlebectomy and foam sclerotherapy. They may make these procedures more comfortable for the patient and easier for the operator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗