Counterpart Test on IBLOCA of 13% Cold Leg Break in ATLAS Facility

In the analysis for Loss-of-Coolant Accident (LOCA) as a design-basis accident (DBA) of a pressurized water reactor (PWR), redefinition of the break size based on the risk-informed regulation (RIR) is being extensively investigated due to the potential safety benefits. The pipe integrity and break frequency has been found to depend on the pipe size, so that a complete rupture of a smaller pipe such as a pressurizer surge-line or an emergency core cooling system (ECCS) nozzle is more probable than a double-ended guillotine break (DEGB) of primary coolant circuit piping. The scenario with the break of these pipes can be regarded as intermediate break (IB) LOCA. With an aim of expanding code validation to address safety issues of the IBLOCA and developing an evaluation model (EM) for full spectrum LOCA, the database for the IBLOCA test in an integral effect test (IET) facility is essential. In particular, an experimental data from the counterpart test can contribute to enhance our understanding on the phenomena and resolve the scaling issues in the scaled-down test facilities. The objective of this study is to investigate thermal hydraulic phenomena during the IBLOCA by the counterpart test for the 13% cold leg break in ATLAS facility, which was the A.2 test in the OECDATLAS project. This integral effect test would contribute to evaluate the scaling effect of the ATLAS design and test condition.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computation of Air Discharge into a Water Pool by Using Volume-of-Fluid Method

Suppression tanks, in-containment refueling water storage tanks (IRWSTs) and filtered containment venting systems (FCVSs) of nuclear power plants use water pools to accommodate high-pressure and high-temperature discharge of non-condensable gases and/or steam. Dynamic behavior of gas bubbles inside a water pool determines pressure and temperature loading to the system and thus we need validated method for applications. The underlying physics relevant to these problems is still a difficult issue due to the complicated nature of gas- liquid interfacial transfers of mass, momentum, and energy in a two-phase flow. Therefore, notwithstanding many studies performed over the past two or three decades, two-fluid theory is still a formidable task and direct numerical simulation (DNS) needs huge computing cost. Pellegrini et al. analyzed steam condensation and chugging in the water pool of the PPOOLEX STB-24 test by using STAR-CCM+ code implemented with two-phase interface model based on the Rayleigh-Taylor instability theory (RTI) which triggers steam depressurization. For the solution of the fine interface, they used Eulerian-Eulerian model for the fluid domain since the volume-of-fluid (VOF) model requires larger mesh points. The RTI resulted in complete steam condensation consistent with the experiment. The fluid tank was open to the atmosphere. They reported the volume fraction distributions in the pool, not the pool temperature or pressure history. For non-condensing gas discharges, however, the VOF is still a good alternative to the Eulerian two-fluid or the DNS approaches. The spatial distribution of each phase is defined in terms of volume fractions and the cell physical properties are obtained from linear combinations of those of constituent phases weighted by each volume fraction. Therefore, conditions where thermal and phase change effects become important are less likely to be simulated realistically. The VOF model is suited for the simulation of flows where each phase constitutes a large structure with a relatively small total contact area between phases. Present work is also interested in this VOF method for application to air discharge into a water pool which occurs in the early operating stages of the said facilities. Our purpose is to validate the VOF method against an existing air discharge experiment of PPOOLEX by using a commercial CFD code, STAR-CCM+ version 10.04, in terms of macroscopic flow properties. Effect of turbulence is also discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of Non-Invasive Waste Assay System (Gamma Box Counter) Performance at AECL Whiteshell Laboratories - 13136

Low-level radioactive waste (LLW) in solid form, resulting from decommissioning and operations activities at AECL's Whiteshell Laboratories (WL), is packaged in B-25 and B-1000 standard waste containers and characterized before it is shipped to an on-site interim storage facility, pending AECL decisions on long term management of its LLW. Assay of the waste packages before shipment contributes to an inventory of the interim storage facility and provides data to support acceptance at a future repository. A key characterization step is a gamma spectrometric measurement carried out under standard conditions using an automated, multi-detector Waste Assay System (WAS), purchased from Antech Corporation. A combination of ORTEC gamma acquisition software and custom software is used in this system to incorporate multiple measurements from two collimated high-resolution detectors. The software corrects the intensities of the gamma spectral lines for geometry and attenuation, and generates a table of calculated activities or limits of detection for a user-defined list of radioisotopes that may potentially be present. Validation of WAS performance was a prerequisite to routine operation. Documentation of the validation process provides assurance of the quality of the results produced, which may be needed one or two decades after they were generated. Aspects of the validation included setting up a quality control routine, measurements of standard point sources in reproducible positions, study of the gamma background, optimization of user-selectable software parameters, investigation of the effect of non-uniform distribution of materials and radionuclides, and comparison of results with measurements made using other gamma detector systems designed to assay bulk materials. The following key components of the validation process have been established. A daily quality control routine has been instituted, to verify stability of the gamma detector operation and the background levels. A test box containing plywood (specific gravity 0.5) with holes for reproducible positioning of known point sources has been constructed and used in several configurations. Gamma spectra have been processed multiple times with user-adjustable parameters set to a variety of values to gain agreement on the most appropriate settings. A similar optimization process was followed with the custom software provided by the instrument manufacturer to reach agreement on the most stable settings for reliable results. Measurements made with the Canberra In-Situ Object Counting System (ISOCS) instrument were compared with the WAS results as part of an estimate of instrument precision and accuracy. The validation report will conclude with recommendations for the configuration, appropriate use and limitations of the Waste Assay System. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of Data-Driven Mesh-Model Optimization in System Thermal-Hydraulic Simulation

Quantification of nuclear power plant safety risk requires a systematic and yet practical approach to identification of accident scenarios, assessment of their likelihood and consequences. Instrumental to this goal is risk-informed safety margin characterization (RISMC) framework, whose realization requires computationally robust and affordable methods for sufficiently accurate simulation of complex multi-dimensional physical phenomena, such as turbulent and multi-phase flow. The CFD-like correlation-based codes with 3D simulation capability (e.g., GOTHIC) ensure computational efficiency using coarse mesh size and the sub-grid phenomena in the boundary layer that can be captured by adequate constitutive correlations. However, the error sources and user effects on the selection of mesh size and models lead to unpredictable simulation error, while rich High-Fidelity (HF) data from experiments and numerical simulation using validated code or DNS are not fully explored. It would be useful to have a “smart” data-driven multi-scale framework in which the low-resolution models can be “taught” to emulate high-resolution models. The objective of this work is to develop and evaluate a physical-based data-driven mesh-model optimization approach (Optimized Mesh/Model Information System, OMIS) to estimate the simulation error and give advice on the optimized selection of coarse mesh size and Low-Fidelity (LF) models for System Thermal Hydraulic (STH) simulation to achieve accuracy comparable to that of HF models. This approach takes advantages of computational efficiency of coarse-mesh simulation and application of Machine Learning (ML) algorithms.

97 MATHEMATICS AND COMPUTING↗

Direct Numerical Simulation of the Flow through a Randomly Packed Pebble Bed

The proposition for molten salt and high-temperature gas-cooled reactors has increased the focus on the dynamics and physics in randomly packed pebble beds. Research is being conducted on the validity of these designs as a possible contestant for the fourth-generation nuclear power systems. A detailed understanding of the coolant flow behavior is required in order to ensure proper cooling of the reactor core during normal and accident conditions. In order to increase the understanding of the flow through these complex geometries and enhance the accuracy of lower-fidelity modeling, high-fidelity approaches such as direct numerical simulation (DNS) can be utilized. Nek5000, a spectral-element computational fluid dynamics (CFD) code, was used to develop DNS fluid flow data. The flow domain consisted of 147 pebbles enclosed by a bounding wall. In the work presented, the Reynolds numbers ranged from 430 to 1050 based on the pebble diameter and inlet velocity. Characteristics of the flow domain such as volume averaged porosity, axial porosity, and radial porosity were studied and compared with correlations available in the literature. Friction factors from the DNS results for all Reynolds numbers were compared with correlations in the literature. The first- and second-order statistics show good agreement with the available experimental data. Turbulence length scales were analyzed in the flow. Reynolds stress anisotropy was characterized by utilizing invariant analysis. Overall, the results of the analysis in this study provide deeper understanding of the flow behavior and the effect of the wall in packed beds.

Yildiz, Mustafa Alper↗

Time dependent supervisory control update with FARM using rolling window

This report describes improvements to the Feasible Actuator Range Modifier (FARM) component of the RAVEN-based HYBRID framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON plug-in that solves the power dispatch problem. The solution to the dispatch problem involves economically optimal dispatches that satisfy limits on production variables and their rates of variation (explicit constraints) as well as process variables tied to the service life of equipment (implicit constraints). FARM serves to validate or confirm that a HERON solution for explicit constraints also satisfies the implicit constraints. FARM-alpha was released by Argonne National Laboratory in January 2021 followed by FARM-Beta in January 2022 with the latter providing increased flexibility for the user. In this report, FARM-Gamma, the latest version of the code, is described. The major improvement is the implementation of a system identification algorithm based on the Dynamic Mode Decomposition with Control (DMDc) coupled with a “Rolling Window” scheme that allows obtaining linear time-varying state-space models. This feature equips FARM with the most accurate approximation of system dynamics, and it relieves the user from the burden of performing an exhaustive off-line characterization of the dynamics. FARM-Gamma capabilities are assessed by solving the power dispatch problem for a representative IES unit. The simulation times corresponding to the different releases are estimated and compared. These values capture the increasing computational burden of the successively higher fidelity state-space models adopted by FARM-Alpha, FARM-Beta and FARM-Gamma. The code implementation provides significant flexibility, i.e., the user can always select the most suitable version of FARM according to the problem to be solved and the available computational resources. It is anticipated that FARM will play a role in addressing several future IES applications. We outline how it can support the coordinated management and safe operation of a nuclear plant coupled to industrial processes to produce hydrogen and synfuels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of Minimum Display Requirements for a UAS Detect and Avoid System

The full integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS), a prerequisite for enabling a broad range of public and commercial UAS operations, presents several technical challenges to UAS developers, operators and regulators. A primary barrier is the inability for UAS pilots (situated at a ground control station, or GCS) to comply with Title 14 Code of Federal Regulations sections 91.111 and 91.113, which require pilots to “see and avoid” other aircraft in order to maintain well clear. UAS pilots’ removal from the flight deck of the aircraft necessitates the development of a UAS-specific system for detecting nearby traffic and displaying traffic information to the pilot to support their ability to maintain an objectively defined “DAA well clear” threshold from other aircraft. This new UAS-specific function of remaining DAA well clear is called traffic avoidance. The resulting Detect and Avoid (DAA) system, however, will be subject to a collection of requirements that manufacturers will be obligated to meet in order to certify their equipment. RTCA Special Committee 228 (SC-228), a consortium of representatives from government, industry and academia, is responsible for developing and documenting the Minimum Operational Performance Standards (MOPS) for UAS DAA systems. The present study is the final in a series of human-in-the-loop (HITL) experiments designed to explore and test the various display and alerting requirements being incorporated into the DAA MOPS. Whereas the prior DAA HITLs examined a wide variety of DAA display features and concepts, the current experiment aims to validate the latest minimum display requirements for Phase 1 of the DAA MOPS. Rather than test different display concepts, this study tests two configurations of a MOPS-compatible DAA display: a version that is integrated into the primary navigation and control display of the GCS and a version that is physically separated from the primary display. This manipulation tests the draft minimum requirement that allows the DAA traffic display to be a separate, or standalone, configuration. This type of configuration is a more achievable near-term technology solution since it does not stipulate additional certification or integration requirements on UAS manufacturers. However, a standalone display configuration has the potential to result in pilot performance issues resulting from the cognitive costs of switching between the primary DAA display and the primary navigation and control display. This configuration is also particularly susceptible to errors if the displays are in different orientations (e.g., north-up versus track-up). Both the integrated and standalone display configurations were presented to 16 active UAS pilots in a medium-fidelity simulation, which included confederate air traffic controllers and pseudo pilots operating simulated manned traffic. Pilots were tasked with navigating two different mission routes while maintaining DAA well clear with scripted conflicts. Pilot response times (i.e., measured response) and ability to remain DAA well clear are reported. Primary results indicate that both display configurations resulted in favorable response times and well clear rates. While there were clear trends of pilots objectively performing better in the integrated display condition, with several measured response metrics reaching statistical significance, the differences between the two displays were typically moderate. While the primary variable of DAA display location did not have an especially large impact on pilot performance on its own, when examined alongside the type of DAA threat the pilot was facing (a caution-level versus a warning-level alert), the response time benefits associated with the integrated display were amplified. The implications of these American Institute of Aeronautics and Astronautics 2 results on the Phase 1 DAA MOPS and the connection of this data to previous studies is also discussed.

detect and avoid↗

High-Fidelity Simulation of Flow-Induced Vibrations in Helical Steam Generators for Small Modular Reactors

Flow-induced vibration (FIV) is a widespread problem in energy systems as they rely on fluid movement for energy conversion. Vibrating structures may be damaged as fatigue or wear occur. Given the importance of reliable components in the nuclear industry, FIV has long been a major concern in the safety and operation of nuclear reactors. In particular, nuclear fuel rods and steam generators have been known to suffer from FIV and related failures. In this paper we discuss the use of the computational fluid dynamics code Nek5000 coupled to the structural code Diablo to simulate the flow in helical coil heat exchangers and associated FIV. In particular, one-way coupled calculations are performed, where pressure and tractions data are loaded into the structural model. The main focus of this paper is on validation of this capability. Fluid-only Nek5000 large eddy simulations are first compared against dedicated high-resolution experiments. Then, one-way coupled calculations are performed with Nek5000 and Diablo for two data sets that provide FIV data for validation. These calculations were aimed at simulating available legacy FIV experiments in helical steam generators in the turbulent buffeting regime. In this regime one-way coupling is judged sufficient since the pressure loads do not cause substantial displacements. It is also the most common source of vibration in helical steam generators at the low flows expected in integral pressurized water reactors. We discuss validation of two-way coupled experiments and benchmarks toward the simulation of fluid elastic instability. We briefly discuss the application of these methods to grid-to-rod fretting.

Flow-Induced Vibration↗

Technical Note: Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film for photons in the energy range 3 keV–18 MeV

Purpose: Water is the reference medium for radiation therapy dosimetry, but for film dosimetry it is more practical to use a solid phantom. As the composition of solid phantoms differs from that of water, the energy dependence of film exposed within solid phantoms may also differ. The energy dependence of a radiochromic film for a given beam quality Q (energy for monoenergetic beams) has two components: the intrinsic energy dependence and the absorbed-dose energy dependence f(Q), the latter of which can be calculated through a Monte Carlo simulation of radiation transport. The authors used Monte Carlo simulations to study the influence of the phantom material on the f(Q) of the EBT3 radiochromic film (Ashland Specialty Ingredients, Wayne, NJ) for photon beams with energies between 3 keV and 18 MeV. Methods: All simulations were carried out with the general-purpose Monte Carlo code PENELOPE 2011. The geometrical model consisted of a cylindrical phantom, with the film positioned at different depths depending on the initial photon energy. The authors simulated monoenergetic parallel photon beams and x-ray beams from a superficial therapy system. To validate their choice of simulation parameters, they also calculated f(Q) for older film models, EBT and EBT2, comparing with published results. In addition to water, they calculated f(Q) of the EBT3 film for solid phantom materials commonly used for film dosimetry: RW1 and RW3 (PTW-Freiburg, Freiburg, Germany), Solid Water (Gammex-RMI, Madison, WI), and PMMA. Finally, they combined their calculated f(Q) with published overall energy response data to obtain the intrinsic energy dependence of the EBT3 film in water. Results: The calculated f(Q) for EBT and EBT2 films was statistically compatible with previously published data. Between 10 keV and 18 MeV, the variation found in f(Q) of the EBT3 film for water was within 2.3%, with a standard statistical uncertainty less than 1%. If the quantity dose-to-water in the phantom is considered, which is the common practice in radiation dosimetry, the maximum difference of energy dependence for the solid phantoms with respect to water is about 6%, at an energy of 50 keV. Conclusions: The EBT3 film shows a reasonably constant absorbed-dose energy dependence when irradiated in water. If the dose-to-water in the phantom is considered, the maximum difference of EBT3 film energy dependence with the solid phantoms studied with respect to water is about 6% (at an energy of 50 keV). The reported overall energy dependence of the EBT3 film in water at energies below 100 keV is mainly due to the intrinsic energy dependence.

07 ISOTOPE AND RADIATION SOURCES↗

SCALE Code System 6.2.2

The SCALE Code System is a widely used modeling and simulation suite for nuclear safety analysis and design that is developed, maintained, tested, and managed by the Reactor and Nuclear Systems Division (RNSD) of Oak Ridge National Laboratory (ORNL). SCALE provides a comprehensive, verified and validated, user-friendly tool set for criticality safety, reactor physics, radiation shielding, radioactive source term characterization, and sensitivity and uncertainty analysis. Since 1980, regulators, licensees, and research institutions around the world have used SCALE for safety analysis and design. SCALE provides an integrated framework with dozens of computational modules including 3 deterministic and 3 Monte Carlo radiation transport solvers that are selected based on the desired solution strategy. SCALE includes current nuclear data libraries and problem-dependent processing tools for continuous-energy (CE) and multigroup (MG) neutronics and coupled neutron-gamma calculations, as well as activation, depletion, and decay calculations. SCALE includes unique capabilities for automated variance reduction for shielding calculations, as well as sensitivity and uncertainty analysis. SCALE’s graphical user interfaces assist with accurate system modeling, visualization of nuclear data, and convenient access to desired results. SCALE 6.2 represents one of the most comprehensive revisions in the history of SCALE, providing several new capabilities and significant improvements in many existing features.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE Code System

The SCALE Code System is a widely used modeling and simulation suite for nuclear safety analysis and design that is developed, maintained, tested, and managed by the Reactor and Nuclear Systems Division (RNSD) of Oak Ridge National Laboratory (ORNL). SCALE provides a comprehensive, verified and validated, user-friendly tool set for criticality safety, reactor and lattice physics, radiation shielding, spent fuel and radioactive source term characterization, and sensitivity and uncertainty analysis. Since 1980, regulators, licensees, and research institutions around the world have used SCALE for safety analysis and design. SCALE provides an integrated framework with dozens of computational modules, including three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution strategy. SCALE includes current nuclear data libraries and problem-dependent processing tools for continuous-energy (CE) and multigroup (MG) neutronics and coupled neutron-gamma calculations, as well as activation, depletion, and decay calculations. SCALE includes unique capabilities for automated variance reduction for shielding calculations, as well as sensitivity and uncertainty analysis. SCALE’s graphical user interfaces assist with accurate system modeling, visualization of nuclear data, and convenient access to desired results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a CFD code for casting simulation

The task of developing a computational fluid dynamics (CFD) code to accurately model the mold filling phase of a casting operation was accomplished in a systematic manner. First the state-of-the-art was determined through a literature search, a code search, and participation with casting industry personnel involved in consortium startups. From this material and inputs from industry personnel, an evaluation of the currently available codes was made. It was determined that a few of the codes already contained sophisticated CFD algorithms and further validation of one of these codes could preclude the development of a new CFD code for this purpose. With industry concurrence, ProCAST was chosen for further evaluation. Two benchmark cases were used to evaluate the code's performance using a Silicon Graphics Personal Iris system. The results of these limited evaluations (because of machine and time constraints) are presented along with discussions of possible improvements and recommendations for further evaluation.

Murph, Jesse E.↗

A Computational Study of BVI Noise Reduction Using Active Twist Control

The results of a computational study examining the effects of active-twist control on blade-vortex interaction (BVI) noise using the Apache Active Twist Rotor are presented. The primary goal of this activity is to reduce BVI noise during a low-speed descent flight condition using active-twist control. Rotor aeroelastic behavior was modeled using the Comprehensive Analytical Model of Rotorcraft Aerodynamics and Dynamics code and the rotor noise was predicted using the acoustics code PSU-WOPWOP. The accuracy of the analysis was validated through comparisons with experimental acoustic data for the first generation Active Twist Rotor at an advance ratio of mu=0.14. The application of active-twist to the main rotor blade system consisted of harmonic actuation frequencies ranging from 2P to 5P, control phase angles from 0' to 360 , and tip-twist amplitudes ranging from 0.5 to 4.0 . The acoustic analysis was conducted for a single low-speed flight condition of advance ratio =0.14 and shaft angle-of-attack, c^=+6 , with BVI noise levels predicted on a flat plane of observers located 1.1 rotor diameters beneath the rotor. The results indicated reductions of up to 11dB in BVI noise using 1.25 tip-twist amplitude with negligible effects on 4P vertical hub shear.

Fogarty, David E.↗

Preliminary Results From a Heavily Instrumented Engine Ice Crystal Icing Test in a Ground Based Altitude Test Facility

Preliminary results from the heavily instrumented ALF502R-5 engine test conducted in the NASA Glenn Research Center Propulsion Systems Laboratory are discussed. The effects of ice crystal icing on a full scale engine is examined and documented. This same model engine, serial number LF01, was used during the inaugural icing test in the Propulsion Systems Laboratory facility. The uncommanded reduction of thrust (rollback) events experienced by this engine in flight were simulated in the facility. Limited instrumentation was used to detect icing on the LF01 engine. Metal temperatures on the exit guide vanes and outer shroud and the load measurement were the only indicators of ice formation. The current study features a similar engine, serial number LF11, which is instrumented to characterize the cloud entering the engine, detect/characterize ice accretion, and visualize the ice accretion in the region of interest. Data were acquired at key LF01 test points and additional points that explored: icing threshold regions, low altitude, high altitude, spinner heat effects, and the influence of varying the facility and engine parameters. For each condition of interest, data were obtained from some selected variations of ice particle median volumetric diameter, total water content, fan speed, and ambient temperature. For several cases the NASA in-house engine icing risk assessment code was used to find conditions that would lead to a rollback event. This study further helped NASA develop necessary icing diagnostic instrumentation, expand the capabilities of the Propulsion Systems Laboratory, and generate a dataset that will be used to develop and validate in-house icing prediction and risk mitigation computational tools. The ice accretion on the outer shroud region was acquired by internal video cameras. The heavily instrumented engine showed good repeatability of icing responses when compared to the key LF01 test points and during day-to-day operation. Other noticeable observations are presented.

Enigine Icing↗

Preliminary Results From a Heavily Instrumented Engine Ice Crystal Icing Test in a Ground Based Altitude Test Facility

Preliminary results from the heavily instrumented ALF502R-5 engine test conducted in the NASA Glenn Research Center Propulsion Systems Laboratory are discussed. The effects of ice crystal icing on a full scale engine is examined and documented. This same model engine, serial number LF01, was used during the inaugural icing test in the Propulsion Systems Laboratory facility. The uncommanded reduction of thrust (rollback) events experienced by this engine in flight were simulated in the facility. Limited instrumentation was used to detect icing on the LF01 engine. Metal temperatures on the exit guide vanes and outer shroud and the load measurement were the only indicators of ice formation. The current study features a similar engine, serial number LF11, which is instrumented to characterize the cloud entering the engine, detect/ characterize ice accretion, and visualize the ice accretion in the region of interest. Data were acquired at key LF01 test points and additional points that explored: icing threshold regions, low altitude, high altitude, spinner heat effects, and the influence of varying the facility and engine parameters. For each condition of interest, data were obtained from some selected variations of ice particle median volumetric diameter, total water content, fan speed, and ambient temperature. For several cases the NASA in-house engine icing risk assessment code was used to find conditions that would lead to a rollback event. This study further helped NASA develop necessary icing diagnostic instrumentation, expand the capabilities of the Propulsion Systems Laboratory, and generate a dataset that will be used to develop and validate in-house icing prediction and risk mitigation computational tools. The ice accretion on the outer shroud region was acquired by internal video cameras. The heavily instrumented engine showed good repeatability of icing responses when compared to the key LF01 test points and during day-to-day operation. Other noticeable observations are presented.

turbomachinery↗

OECD-NEA HTTF Benchmark Progress and Updates

General slides discussing High Temperature Test Facility benchmark progress, Prismatic HTGR deployment, modeling and simulation tools for validating systems, and verification and validation issues. Also discuss collaboration and conclusions of RELAP5-3D validation activities based on HTTF with trends in data and international impact to accelerate deployment of prismatic HTGR microreactors by providing an opportunity for designers to assess their codes against experimental data and solutions from other codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Development of a Drift-Flux Model Based Pin-Resolved Core Thermal-Hydraulic Code for Dedicated Use in Efficient High-Fidelity Neutronics Coupled Calculations

As the high-fidelity multiphysics coupled core calculation becomes more practical with the advent of high-performance computing technology, efficient coupling of a neutronics code with a thermal-hydraulic (T/H) code at the pin level poses a new challenge. The COBRA-TF (CTF) code which is one of the well-known subchannel analysis codes based on the two-fluid, three-field model was coupled with many neutron transport codes such as MPACT, TORTTD, and nTRACER due to the easiness of coupling by its well-established coupling interface. Nevertheless, the calculation efficiency of such coupled codes is not satisfactory because of the heavy computational burden of CTF. The MATRA subchannel analysis code of KAERI which is based on the homogeneous equilibrium model (HEM) was coupled with neutronics codes as well. The choice of the HEM and the marching scheme in MATRA reduces the computational burden significantly. However, the applicability of the HEM for the two-phase flow conditions is limited to normal operating conditions of pressurized water reactors (PWRs) and therefore a better model which would allow wider applicability than HEM is necessary in order to deal with the core states involving nontrivial voiding. The drift-flux model (DFM) which uses 5 equations for two-fluid analyses by adopting the mixture velocity instead of two phasic velocities can be a good compromise between the two-fluid model and the HEM. With the DFM, the computational cost can be reduced and moreover the modeling of the interfacial area constitutive relations can be avoided. The phase separation for the mixture velocity can be incorporated by using the drift-flux parameters, C0 and Vgj, which can be obtained by using empirical formulas. Several subchannel codes such as WOSUB and ASSERT were developed based on the DFM. It was also adopted in some system analysis codes such as RETRAN3D. In the work here, the development of a DFM based pin-resolved T/H analysis code, ESCOT (Efficient Simulator of Core Thermal-hydraulics), is introduced for the use in efficient coupled calculations with a high-fidelity neutronics code. The field equations and the numerical methods are briefly described. Then the efficiency tests of various linear system solvers including the Krylov subspace methods (KSMs) are presented. A test problem is solved by ESCOT, MATRA and CTF for performance comparison and validation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Calculation of the dynamic first electronic hyperpolarizability β(−ω{sub σ}; ω{sub 1}, ω{sub 2}) of periodic systems. Theory, validation, and application to multi-layer MoS{sub 2}

We describe our implementation of a fully analytical scheme, based on the 2n + 1 rule, for computing the coupled perturbed Hartree Fock and Kohn-Sham dynamic first hyperpolarizability tensor β(−ω{sub σ}; ω{sub 1}, ω{sub 2}) of periodic 1D (polymer), 2D (slab), and 3D (crystal) systems in the CRYSTAL code [R. Dovesi et al., Int. J. Quantum Chem. 114, 1287 (2014)], which utilizes local Gaussian type basis sets. The dc-Pockels (dc-P) and second harmonic generation (SHG) tensors are included as special cases. It is verified that (i) symmetry requirements are satisfied; (ii) using LiF as an example, the infinite periodic polymer result agrees with extrapolated finite oligomer calculations and, likewise, for the build-up to a 2D slab and a 3D crystal; (iii) the values converge to the static case for low frequencies; and (iv) the Bishop-deKee dispersion formulas relating dc-P, SHG, and general processes are reproduced through quartic terms. Preliminary SHG calculations on multi-layer MoS{sub 2} satisfactorily reproduce experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗