Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Investigations of plasma evolution in Laser Ablation Z-Pinch Experiments using Time-Resolved Optical Spectroscopy

In this dissertation, investigations of the temporal evolution of magnetically driven plasmas are presented. These studies were carried at the Nevada Terawatt Facility using the Zebra pulsed-power accelerator to magnetically compress and confine a cylindrical plasma column. Important parameters needed to characterize these laboratory plasmas include magnetic field strength and orientation, as well as electron number density and temperature. To fully understand the characteristics of a plasma, accurate experimental measurement of these parameters is essential. To determine the electron temperature, the Boltzmann plot method was used. Simulated spectra from PrismSPECT were compared to experimental measurements in order to measure electron number density and temperature early in the pinched plasma formation. Simultaneously, Mach-Zehnder laser interferometry was used to provide complementary measurements of the electron number density. A novel method, streaked Zeeman-induced Magnetic Splitting optical spectroscopy, was developed to measure time- and space-resolved magnetic field strengths in these hot, dense plasmas. This technique has also been applied to diagnose the magnetic field strengths in laser ablation Z-pinch experiments, wherein a pulsed power driver pinches a laser ablated plume.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved pump-probe experiments beyond the jitter limitations at FLASH

Using a noninvasive, electro-optically based electron bunch arrival time measurement at FLASH (free electron laser in Hamburg) the temporal resolution of two-color pump-probe experiments has been significantly improved. The system determines the relative arrival time of the extended ultraviolet pulse of FLASH and an amplified Ti:sapphire femtosecond-laser pulse at the interaction region better than 90 fs rms. In a benchmarking pump-probe experiment using two-color above threshold ionization of noble gases, an enhancement in the timing resolution by a factor of 4 compared to the uncorrected data is obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calculation of the weighting functions for the reconstruction of absorbing inhomogeneities in tissue by time-resolved optical projections

We report a new method for determining the weighting functions to reconstruct absorbing inhomogeneities in tissue by perturbation time-domain diffuse optical tomography using the transmission geometry of a flat layer. The method is based on an analytical approach to the calculation of the weighting functions for a semi-infinite scattering medium and on the use of the original method of an equivalent inverse source in order to obtain weight distributions for the flat layer geometry. The correctness of the proposed method of the weighting function calculation is evaluated by a numerical experiment on the reconstruction of absorbing inhomogeneities. It is shown that the perturbation reconstruction model based on the proposed weighting function calculation method allows the inhomogeneities smaller than 0.3 cm and ∼0.4 cm, located respectively in the transverse and longitudinal directions to the probe light direction, to be resolved in the centre of an 8-cm-thick object. (laser biophotonics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved synchrotron x-ray diffraction studies of the crystallization of amorphous Co (80-x) Fe x B₂₀

This paper addresses the time-dependent crystallization process occurring in “bulk” amorphous Co (80-x) Fe x B₂₀ (x = 20, 40) metallic ribbons by means of synchrotron x-ray diffraction (SXRD) and transmission electron microscopy. Metallic ribbons, produced via melt-spinning technique, were annealed in-situ, with SXRD patterns collected every 60 s. SXRD reveals that Co₄₀Fe₄₀B₂₀ alloys crystallize from an amorphous structure to a primary bcc α-(Co,Fe) phase, whereas Co₆₀Fe₂₀B₂₀ initially crystallizes into the same bcc α-(Co,Fe) but exhibits cooperative growth of both stable and metastable boride phases later into the hold. Johnson-Mehl-Avrami-Kolmogorov statistics was used on post annealed samples to determine the mechanisms of growth and the activation energy (E a ) of the α-(Co,Fe) phase. Results indicate that the growth mechanisms are similar for both alloy compositions for all annealing temperatures, with the Avrami exponent of n = 1.51(1) and 2.02(6) for x = 20 and 40, respectively, suggesting one-dimensional growth, with a decreasing nucleation rate. Activation energy for α-(Co,Fe) was determined to be 2.7(1) eV and 2.4(3) eV in x = 20 and 40, respectively, suggesting that those alloys with a lower Co content have a stronger resistance to crystallization. Based on these results, fabrication of CoFeB magnetic tunnel junctions via depositing amorphous layers and subsequently annealing to induce lattice matching presents itself as a viable and efficient method, for increasing the giant magnetoresistance in magnetic tunnel junctions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonperturbative computation of the time-resolved formation of the profile of autoionizing states as a function of the intensity and duration of ultrashort pulses

By solving the time-dependent Schroedinger equation nonperturbatively by the state-specific expansion approach, we have obtained reliable results showing the dependence of the formation of the excitation profile of the autoionizing state He {sup '}2s2p{sup '} {sup 1}P{sup o} for Gaussian pulses of intensities in the range I{approx_equal}10{sup 10} W/cm{sup 2} to I{approx_equal}10{sup 15} W/cm{sup 2}, and of duration 100-2 fs. Conclusions are drawn as regards the breakdown of first-order time-dependent perturbation theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multi-scale time-resolved electron diffraction: A case study in moiré materials

Ultrafast-optical-pump — structural-probe measurements, including ultrafast electron and x-ray scattering, provide direct experimental access to the fundamental timescales of atomic motion, and are thus foundational techniques for studying matter out of equilibrium. High-performance detectors are needed in scattering experiments to obtain maximum scientific value from every probe particle. Here we deploy a hybrid pixel array direct electron detector to perform ultrafast electron diffraction experiments on a WSe 2 /MoSe 2 2D heterobilayer, resolving the weak features of diffuse scattering and moiré superlattice structure without saturating the zero order peak. Enabled by the detector’s high frame rate, we show that a chopping technique provides diffraction difference images with signal-to-noise at the shot noise limit. Finally, we demonstrate that a fast detector frame rate coupled with a high repetition rate probe can provide continuous time resolution from femtoseconds to seconds, enabling us to perform a scanning ultrafast electron diffraction experiment that maps thermal transport in WSe 2 /MoSe 2 and resolves distinct diffusion mechanisms in space and time.

36 MATERIALS SCIENCE↗

Time-resolved measurements of OH during auto-ignition of syngas with trimethylsilanol and hexamethyldisiloxane

The effects of trimethylsilanol (TMSO) and hexamethyldisiloxane (HMDSO) addition on OH time histories during syngas (H 2 and CO) ignition were investigated using the University of Michigan rapid compression facility. Experiments spanned temperatures of 1010–1080 K, at a pressure of approximately 5 atm. Syngas mixtures of 1.2 % H 2 /2.8 % CO/20 % O 2 by volume (balance N 2 and Ar) provided a baseline for comparison with mixtures that included 100, 200, and 1000 ppm of the TMSO and 100 ppm of HMDSO. Narrow-line ultraviolet laser-absorption was used to measure OH mole-fraction during ignition. The addition of TMSO and HMDSO significantly shifted the OH time-histories earlier in time, by up to 51 %, compared with the baseline syngas mixture. The value of the maximum OH mole fraction was consistent between the 100 and 200 ppm TMSO mixtures and the 100 ppm HMDSO mixtures, but the maximum OH increased significantly with the 1000 ppm TMSO mixtures. Here, the OH data indicate TMSO and HMDSO were not direct sources of OH radicals. Analysis further indicates the TMSO and HMDSO decompose rapidly followed by reactions that enhance the production of H atoms, and the increased reactivity observed is via the H + O 2 = OH + O reaction.

Hexamethyldisiloxane↗

High-speed x-ray imaging with the Keck pixel array detector (Keck PAD) for time-resolved experiments at synchrotron sources

Modern storage rings are readily capable of providing intense x-ray pulses, tens of picoseconds in duration, millions of times per second. Exploiting the temporal structure of these x-ray sources opens avenues for studying rapid structural changes in materials. Many processes (e.g. crack propagation, deformation on impact, turbulence, etc.) differ in detail from one sample trial to the next and would benefit from the ability to record successive x-ray images with single x-ray sensitivity while framing at 5 to 10 MHz rates. To this end, we have pursued the development of fast x-ray imaging detectors capable of collecting bursts of images that enable the isolation of single synchrotron bunches and/or bunch trains. The detector technology used is the hybrid pixel array detector (PAD) with a charge integrating front-end, and high-speed, in-pixel signal storage elements. A 384×256 pixel version, the Keck-PAD, with 150 µm × 150 µm pixels and 8 dedicated in-pixel storage elements is operational, has been tested at CHESS, and has collected data for compression wave studies. An updated version with 27 dedicated storage capacitors and identical pixel size has been fabricated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kerb and urban increment of highly time-resolved trace elements in PM 10 , PM 2.5 and PM 1.0 winter aerosol in London during ClearfLo 2012

Ambient concentrations of trace elements with 2 h time resolution were measured in PM 10–2.5 , PM 2.5–1.0 and PM 1.0–0.3 size ranges at kerbside, urban background and rural sites in London during winter 2012. Samples were collected using rotating drum impactors (RDIs) and subsequently analysed with synchrotron radiation-induced X-ray fluorescence spectrometry (SR-XRF). Quantification of kerb and urban increments (defined as kerb-to-urban and urban-to-rural concentration ratios, respectively), and assessment of diurnal and weekly variability provided insight into sources governing urban air quality and the effects of urban micro-environments on human exposure. Traffic-related elements yielded the highest kerb increments, with values in the range of 10.4 to 16.6 for SW winds (3.3–6.9 for NE) observed for elements influenced by brake wear (e.g. Cu, Sb, Ba) and 5.7 to 8.2 for SW (2.6–3.0 for NE) for other traffic-related processes (e.g. Cr, Fe, Zn). Kerb increments for these elements were highest in the PM 10–2.5 mass fraction, roughly twice that of the PM 1.0–0.3 fraction. These elements also showed the highest urban increments (~ 3.0), although no difference was observed between brake wear and other traffic-related elements. All elements influenced by traffic exhibited higher concentrations during morning and evening rush hours, and on weekdays compared to weekends, with the strongest trends observed at the kerbside site, and additionally enhanced by winds coming directly from the road, consistent with street canyon effects. Elements related to mineral dust (e.g. Al, Si, Ca, Sr) showed significant influences from traffic-induced resuspension, as evidenced by moderate kerb (3.4–5.4 for SW, 1.7–2.3 for NE) and urban (~ 2) increments and increased concentrations during peak traffic flow. Elements related to regional transport showed no significant enhancement at kerb or urban sites, with the exception of PM 10–2.5 sea salt (factor of up to 2), which may be influenced by traffic-induced resuspension of sea and/or road salt. Heavy-duty vehicles appeared to have a larger effect than passenger vehicles on the concentrations of all elements influenced by resuspension (including sea salt) and wearing processes. In conclusion, trace element concentrations in London were influenced by both local and regional sources, with coarse and intermediate fractions dominated by traffic-induced resuspension and wearing processes and fine particles influenced by regional transport.

54 ENVIRONMENTAL SCIENCES↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

Ultrafast time-resolved X-ray absorption spectroscopy of ferrioxalate photolysis with a laser plasma X-ray source and microcalorimeter array

The detailed pathways of photoactivity on ultrafast time scales are a topic of contemporary interest. Using a tabletop apparatus based on a laser plasma X-ray source and an array of cryogenic microcalorimeter X-ray detectors, we measured a transient X-ray absorption spectrum during the ferrioxalate photoreduction reaction. With these high-efficiency detectors, we observe the Fe K edge move to lower energies and the amplitude of the extended X-ray absorption fine structure reduce, consistent with a photoreduction mechanism in which electron transfer precedes disassociation. We provide quantitative limits on the Fe–O bond length change. Lastly, we review potential improvements to our measurement technique, highlighting the future potential of tabletop X-ray science using microcalorimeter sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-Resolved Measurements Of Laser Far-Field Patterns

Computer-controlled scanning photometric instrumentation system measures intensity pattern in far field of pulsed laser as function of time during each pulse (provided that pulse is at least 1 ns long). Such measurements important in studying dynamics of laser operation: they reveal such previously unobservable phenomena as oscillations of undesired spatial modes of radiation pattern during pulse, steering of beam during pulse, and instability of intensity of laser beam. Principal advantages of system are its relatively low cost and its ability to function under normal lighting conditions without incurring damage.

Forrest, Kathrine↗

Hyperchromatic lens for recording time-resolved phenomena

A method and apparatus for the capture of a high number of quasi-continuous effective frames of 2-D data from an event at very short time scales (from less than 10.sup.-12 to more than 10.sup.-8 seconds) is disclosed which allows for short recording windows and effective number of frames. Active illumination, from a chirped laser pulse directed to the event creates a reflection where wavelength is dependent upon time and spatial position is utilized to encode temporal phenomena onto wavelength. A hyperchromatic lens system receives the reflection and maps wavelength onto axial position. An image capture device, such as holography or plenoptic imaging device, captures the resultant focal stack from the hyperchromatic lens system in both spatial (imaging) and longitudinal (temporal) axes. The hyperchromatic lens system incorporates a combination of diffractive and refractive components to maximally separate focal position as a function of wavelength.

47 OTHER INSTRUMENTATION↗

Time resolved spin Seebeck effect experiments

In this Letter, we present the results of transient thermopower experiments, performed at room temperature on yttrium iron garnet/platinum bilayers. Upon application of a time-varying thermal gradient, we observe a characteristic low-pass frequency response of the ensuing thermopower voltage with cutoff frequencies of up to 37 MHz. We interpret our results in terms of the spin Seebeck effect, and argue that small wavevector magnons are of minor importance for the spin Seebeck effect in our thin film hybrid structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

UV Laser-Induced, Time-Resolved Transcriptome Responses of Saccharomyces cerevisiae

We observed the effect on gene transcription of laser-mediated, long-wavelength UV-irradiation of Saccharomyces cerevisiae by RNAseq analysis at times T15, T30, and T60 minutes after recovery in growth medium. Laser-irradiated cells were viable, and the transcriptional response was transient, with over 400 genes differentially expressed at T15 or T30, returning to basal level transcription by T60. Identification of transcripts exhibiting enhanced differential expression that were unique to UV laser-irradiation were identified by imposing a stringent significance cut-off (p <0.05, log 2 difference >2) then filtering out genes known as environmental stress response (ESR) genes. Using these rigorous criteria, 56 genes were differentially expressed at T15; at T30 differential expression was observed for 57 genes, some of which persisted from T15. Among the highly up-regulated genes were those supporting amino acid metabolic processes sulfur amino acids, methionine, aspartate, cysteine, serine), sulfur regulation (hydrogen sulfite metabolic processes, sulfate assimilation, sulfate reduction), proteasome components, amino acid transporters, and the iron regulon. At T30, the expression profile shifted to expression of transcripts related to catabolic processes (oxidoreductase activity, peptidase activity). Transcripts common to both T15 and T30 suggested an up-regulation of catabolic events, including UV damage response genes, and protein catabolism via proteasome and peptidase activity. Specific genes encoding tRNAs were among the down-regulated genes adding to the suggestion that control of protein biosynthesis was a major response to long-wave UV laser irradiation. These transcriptional responses bring light to the remarkable ability of the yeast cell to respond to a UV-induced environmental insult.

59 BASIC BIOLOGICAL SCIENCES↗

Communication: Unraveling the {sup 4}He droplet-mediated soft-landing from ab initio-assisted and time-resolved density functional simulations: Au@{sup 4}He{sub 300}/TiO{sub 2}(110)

An ab-initio-based methodological scheme for He-surface interactions and zero-temperature time-dependent density functional theory for superfluid {sup 4}He droplets motion are combined to follow the short-time collision dynamics of the Au@{sup 4}He{sub 300} system with the TiO{sub 2}(110) surface. This composite approach demonstrates the {sup 4}He droplet-assisted sticking of the metal species to the surface at low landing energy (below 0.15 eV/atom), thus providing the first theoretical evidence of the experimentally observed {sup 4}He droplet-mediated soft-landing deposition of metal nanoparticles on solid surfaces [Mozhayskiy et al., J. Chem. Phys. 127, 094701 (2007) and Loginov et al., J. Phys. Chem. A 115, 7199 (2011)].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-Resolved Serial Femtosecond Crystallography at the EuXFEL

There are 4 different stream files here. Pure dark is only dark run without any usage of LASER excitation. Control experiment is 0.89 microsecond time delay experiment with light and 2 da rk interleaved. i.e Light, Dark1 and Dark2 and the sequence repeats 10ps and 80ps time delays experiments were ran with light and 3 dark interleaved. i.e Light, Dark1, Dark2 and Dark3 and the sequence repeats.

European XFEL↗