Search NASA⌕ Search

SEARCH · Search NASA

Results for “two-phase flow models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Two-Phase Azimuthal Instability Generated By A Supersonic Jet Impinging on A Granular Bed

A persistent azimuthal pattern featuring alternate high and low concentration of ejecta emanating from the area where a supersonic jet (Mach 5.3) impinges on a bed of particles in a near-lunar vacuum condition is studied experimentally. Although this peculiar phenomenon has been documented in early studies motivated by extraterrestrial landing, the mechanism of this pattern is not clearly understood. Recently, a series of experiments were conducted at NASA Marshall Space Flight Center inside a 4.5 m vacuum chamber over a range of reduced ambient pressure. Experimental results show vibrant azimuthal patterns, which are clearest at low ambient pressure. The pattern is shown to be driven by the flow instability at low Reynolds number, despite the supersonic jet employed. The flow instability leads to azimuthal vortex lines, which expel ejecta into streaks between two neighboring vortex lines. A simple model is proposed to explain the observed phenomenon.

Plume Surface Interaction↗

CFD Modeling of Tank Pressurization and Axial Jet Mixing Experiments with and without Non-Condensable Gas in the Ullage

A two-phase CFD model for tank pressurization and following jet mixing of a cryogenic storage tank is presented using VOF approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and vapor regions. The CFD model was validated against pressurization and liquid jet mixing data for a 110-inch diameter tank provided by Bullard1. Cases with like-gas and non-condensable gas pressurization are studied. The results of the cases with like-gas pressurization and following mixing are presented first, focusing on the effects of turbulence at the vapor-liquid interface on the tank pressure and phase change rates predictions. The second part of this paper is devoted to testing and validating the CFD model against non-condensable gas pressurization and following mixing. Tank pressures predicted in both cases are compared with each other and with the experimental data.

Computational Fluid Dynamics↗

Validation of a Two-Phase CFD Model for Predicting Propellant Tank Pressurization and Pressure Collapse in The Ground-Based K-Site Hydrogen Slosh Experiment

A two-phase CFD model for tank pressurization and following sloshing in a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and the vapor regions. The CFD model was validated against pressurization and sloshing data for a 62 cubic foot tank provided by Moran et al. Cases with different sloshing amplitudes and frequencies are studied. The results of modeling tank pressurization are presented first followed by the results of sloshing cases. Predicted tank pressures are compared with the experimental data.

Computational Fluid Dynamics↗

Validation of a Two-Phase CFD Model for Predicting Propellant Tank Pressurization and Pressure Collapse in the Ground-Based K-Site Hydrogen Slosh Experiment

A two-phase CFD model for tank pressurization and following sloshing in a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and the vapor regions. The CFD model was validated against pressurization and sloshing data for a 62 cubic foot tank provided by Moran et al. Cases with different sloshing amplitudes and frequencies are studied. The results of modeling tank pressurization are presented first followed by the results of sloshing cases. Predicted tank pressures are compared with the experimental data.

Computational Fluid Dynamics↗

CFD Modeling of Tank Pressurization and Axial Jet Mixing Experiments with and without Non-Condensable Gas in the Ullage

A two-phase CFD model for tank pressurization and following jet mixing of a cryogenic storage tank is presented using VOF approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and vapor regions. The CFD model was validated against pressurization and liquid jet mixing data for a 110-inch diameter tank provided by Bullard. Cases with like-gas and non-condensable gas pressurization are studied. The results of the cases with like-gas pressurization and following mixing are presented first, focusing on the effects of turbulence at the vapor-liquid interface on the tank pressure and phase change rates predictions. The second part of this paper is devoted to testing and validating the CFD model against non-condensable gas pressurization and following mixing. Tank pressures predicted in both cases are compared with each other and with the experimental data.

Computational Fluid Dynamics↗

Validation of a Two-Phase CFD Model for Predicting Tank Self-Pressurization in the Ground-Based K-Site Experiment

A two-phase CFD model for self-pressurization of a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and the vapor regions. The CFD model is validated against self-pressurization experiment performed in the K-site flightweight hydrogen storage tank at NASA Glenn Research Center. Laminar and turbulent simulations together with conjugated heat transfer analysis are performed. Effects of turbulence, as well as tank wall conduction are presented and discussed. Predicted tank pressures and fluid temperatures are compared with the experimental data at two different heat loads for validating the CFD model.

phase change↗

Validation of Two Phase Flow Modeling Techniques in Loci-Stream using Axial Jet Pressure Control and Autogenous Pressurization Experiment

Autogenous pressurization of cryogenic propellant tanks eliminates the need to have an additional pressurant tank on the space vehicle, which is highly advantageous due to reduced vehicle mass and design complexity. Autogenous pressurization therefore is one of the key technologies for deep space exploration and long-term space missions. The complex interaction of thermal gradients, turbulence and phase change near the interface make the problem a challenging one to model. Nodal analysis tools and reduced order models are unable to capture the necessary physics. 3-D CFD analyses are necessary to fully characterize autogenous pressurization. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. We demonstrate our modeling approach and validation of Loci-Stream for predicting autogenous pressurization of a flight scale propellant tank in order for the solver to serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the MSFC test stand 300 facilities provide reliable validation data for this purpose. These tests were modeled using the Loci-Stream solver with a newly implemented two-phase sharp interface treatment. We show that our modeling approach and CFD solver predict the autogenous pressurization phenomena satisfactorily, and document challenging aspects of modeling this problem.

cryogenic fluid management↗

Validation of a Two-Phase CFD Model for Autogenous Pressurization and Expulsion

This paper presents a two-phase computational fluid dynamics (CFD) model for simulating autogenous pressurization and expulsion in a cryogenic liquid hydrogen storage tank, utilizing a volume-of-fluid (VOF) approach combined with the kinetics-based Schrage equation to accurately capture the phase boundary and interfacial heat, mass, and momentum transfer between liquid and vapor phases. The model is validated against experimental data from NASA's K-site tank facility, specifically experimental case 225, which involved pressurization and controlled expulsion of liquid hydrogen. Various turbulence models are evaluated to assess their influence on model accuracy. The CFD simulations successfully replicate key thermodynamic behaviors observed during the experiments, including pressure evolution, temperature profiles, and phase-change dynamics at the vapor-liquid interface. The predicted tank pressures, temperatures, and pressurant requirements agree with experimental data, with pressurant mass predictions within 16\% of observed values. This study highlights the importance of selecting appropriate turbulence models to accurately simulate complex flow and heat transfer phenomena during tank pressurization and expulsion. By enhancing the accuracy and reliability of CFD models for liquid hydrogen under cryogenic conditions, this research contributes to developing efficient cryogenic propellant management strategies for future space missions.

Computational Fluid Dynamics↗

Validation of a Two-Phase CFD Model for Autogenous Pressurization and Expulsion

This paper presents a two-phase computational fluid dynamics (CFD) model for simulating autogenous pressurization and expulsion in a cryogenic liquid hydrogen storage tank, utilizing a volume-of-fluid (VOF) approach combined with the kinetics-based Schrage equation to accurately capture the phase boundary and interfacial heat, mass, and momentum transfer between vapor and liquid phases. The model is validated against experimental data from NASA's K-site tank facility, specifically experimental case 225, which involved autogenous pressurization and controlled expulsion of liquid hydrogen. Various turbulence models are evaluated to assess their influence on model accuracy. The CFD simulations successfully replicate key thermodynamic behaviors observed during the experiments, including pressure evolution, temperature profiles, and phase-change dynamics at the vapor-liquid interface. The predicted tank pressures and temperatures agree well with experimental data, whereas the pressurant mass predictions are within 16% of observed values. This study emphasizes the importance of selecting appropriate turbulence models to accurately simulate the complex flow and heat transfer phenomena during tank autogenous pressurization and expulsion. By improving the accuracy and reliability of CFD models for these processes, this research contributes to developing efficient cryogenic propellant management strategies for future space missions.

Computational Fluid Dynamics↗

Validation of a Two-Phase CFD Model for Predicting Tank Self-Pressurization in the Ground-Based K-Site Experiment

A two-phase CFD model for self-pressurization of a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for modeling two-phase flow, as well as interfacial heat, mass and momentum transfer between the liquid and vapor regions. The CFD model is validated against self-pressurization experiment performed using the K-site flightweight hydrogen storage tank at NASA Glenn Research Center 1 . Laminar and turbulent simulations are performed together with conjugate heat transfer analysis. Effects of turbulence, the value of accommodation coefficient used for predicting phase change rates, as well as tank wall geometry are presented and discussed. Predicted tank pressures, fluid and wall temperatures are compared with the experimental data at 49% fill level and two different heat loads for validating this CFD model.

Computational Fluid Dynamics↗

A comparison of two-phase computational fluid dynamics codes applied to the ITER first wall hypervapotron.

Enhanced radial transport in the plasma and the effect of ELMS may increase the ITER first wall heat loads to as much as 4 to 5 MW/m{sup 2} over localized areas. One proposed heatsink that can handle these higher loads is a CuCrZr hypervapotron. One concept for a first wall panel consists of 20 hypervapotron channels, each measuring 1400 mm long and 48.5 mm wide. The nominal cooling conditions anticipated for each channel are 400 g/s of water at 3 MPa and 100 C. This will result in boiling over a portion of the total length. A two-phase thermalhydraulic analysis is required to predict accurately the thermal performance. Existing heat transfer correlations used for nucleate boiling are not appropriate here because the flow does not reach fully developed conditions in the multi-segmented channels. Our design-by-analysis approach used two commercial codes, Fluent and Star-CCM+, to perform computational fluid dynamics analyses with conjugate heat transfer. Both codes use the Rensselear (RPI) model for wall heat flux partitioning to model nucleate boiling as implemented in user-defined functions. We present a comparison between the two codes for this Eulerian multiphase problem that relies on temperature dependent materials properties. The analyses optimized the hypervapotron geometry, including teeth height and pitch, as well as the depth of the back channel to permit highly effective boiling heat transfer in the grooves between the teeth while ensuring that no boiling could occur at the back channel exit. The analysis used a representative heat flux profile with the peak heat flux of 5 MW/m{sup 2} limited to a 50 mm length. The maximum surface temperature of the heatsink is 415 C. The baseline design uses 2 mm for the teeth height, a 3 mm width and 6 mm pitch, and a back channel depth of 8 mm. The teeth are detached from the sidewall by a 2-mm-wide slot on both sides that aids in sweep-out and quenching of the vapor bubbles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Eulerian Two-Fluid RANS-based CFD Simulations of a Helical Coil Steam Generator Boiling Tube

As part of a larger effort to demonstrate a simulation-based capability for the evaluation and optimization of helical coil steam generators, the performance of a helical coil steam generator tube is being considered using a Eulerian two-fluid multiphase flow capability implemented within the commercial computational fluid dynamics (CFD) code STAR-CCM+. The objective of these evaluations is to characterize boiling and the resultant two-phase flow structures within the helical coil heat exchanger tube so that structural analyses can more accurately account for vibration sources and damping. These studies have shown that CFD predictions using the two-fluid model are consistent with published measurements of pressure drop and heat transfer characteristics. The sensitivity of model predictions to both flow conditions and modeling parameters associated with bubble dynamics closure models has been investigated.

Pointer, Dave↗

SAS4A/SASSYS-1 VERSION 5.2 SAFETY ANALYSIS CODE SYSTEM

SAS4A/SASSYS-1 is a software simulation tool used to perform deterministic safety analysis of anticipated events as well as design basis and beyond design basis accidents for advanced nuclear reactors. This software can be used to assess the safety of a prescribed reactor design, but it cannot be used to configure a design to meet targeted performance objectives. Detailed, mechanistic models of steady-state and transient thermal, hydraulic, kinetic, and mechanical phenomena are employed to describe the response of the reactor core, the reactor primary and secondary coolant loops, the reactor control and protection systems and the balance-of-plant to accidents caused by changes in coolant flow, oss of heat rejection, or reactivity insertion. The consequences of single and double-fault accidents can be modeled, including fuel and coolant heating, fuel and cladding mechanical behavior, core reactivity feedbacks, coolant loop performance including natural circulation, and decay heat removal. Analyses are typically terminated upon demonstration of reactor and plant shutdown to permanently coolable conditions or upon violation of design basis margins. The objective of the analysis is to quantify accident consequences as measured by the transient behavior of system performance parameters, such as fuel and cladding temperatures, reactivity, and cladding strain. Originally developed for analysis of sodium cooled reactors with oxide fuel clad by stainless steel, the models In SAS4A/SASSYS-1 were subsequently extended and specialized to metallic fuel clad with advanced alloys and to several other coolant options including lead and LBE. METHOD OF SOLUTION: Each subassembly in the reactor core is represented with single or multiple-pin models. One channel represents one or more fuel pins and many channels are employed for a whole-core representation. Heat transfer in each pin is modeled with a two-dimensional (r/z) heat conduction equation. Single and two-phase coolant thermal-hydraulics are simulated with a unique, one-dimensional (axial) multiple-bubble liquid metal boiling model. The transient fuel and cladding mechanical behavior models are integrated with fission product production,release, and transport models. UNIQUE FEATURES: The physical models in SAS4AJSASSYS-1 are highly detailed 1umerical representations of reactor accident conditions based on extensive laboratory and test reactor results. The models are specialized to liquid metal (sodium) cooled fast reactors with oxide or metallic fuel clad with stainless steel.«

Fanning, Thomas↗

Reduced Order Description of Experimental Two-Phase Pipe Flows: Characterization of Flow Structures and Dynamics via Proper Orthogonal Decomposition

Multiphase pipe flow is investigated using proper orthogonal decomposition for tomographic X-ray data, where holdup, cross-sectional phase distributions and phase interface characteristics within the pipe are obtained. Six cases of stratified and mixed flow with water content of 10%, 30% and 80% are investigated to gain insight into effects of velocity and proportion of water on the flow fields. Dispersed and slug flows are separately analyzed to consider the added interface complexity of the flow fields. These regimes are also highly applicable to industry operational flows. Instantaneous and fluctuating phase fractions of the four flow regime are analyzed and reduced order dynamical descriptions are generated. Stratified flow cases display coherent structures that highlight the liquid-liquid interface location while the mixed flow cases show minimal coherence of the eigenmodes. The dispersed flow displays coherent structures for the first few modes near the horizontal center of the pipe, representing the liquid-liquid interface location while the slug flow case shows coherent structures that correspond to the cyclical formation and break up of the slug in the first 5 modes. The low order descriptions of the high water content, stratified flow field indicates that main characteristics can be captured with minimal degrees of freedom. Reconstructions of the dispersed flow and slug flow cases indicate that dominant features are observed in the low order dynamical description utilizing less than 1%of the full order model. POD temporal coefficients a1, a2 and a3 show a high level of interdependence for the slug flowcase. The coefficients also describe the phase fraction holdup as a function of time for both dispersed and slug flow. The second coefficient, a2, and the centerline holdup profile show a mean percent difference below 9% between the two curves. The mathematical description obtained from the decomposition will deepen the understanding of multiphase flow characteristics and is applicable to long distance multiphase transport pipelines, fluidized beds, hydroelectric power and nuclear processes to name a few.

Viggiano, Bianca↗

Coupling procedure for TRANSURANUS and KTF codes

The nuclear industry aims to ensure safe and economic operation of each single fuel rod introduced in the reactor core. This goal is even more challenging nowadays due to the current strategy of going for higher burn-up (fuel cycles of 18 or 24 months) and longer residence time. In order to achieve that goal, fuel modeling is the key to predict the fuel rod behavior and lifetime under thermal and pressure loads, corrosion and irradiation. In this context, fuel performance codes, such as TRANSURANUS, are used to improve the fuel rod design. The modeling capabilities of the above mentioned tools can be significantly improved if they are coupled with a thermal-hydraulic code in order to have a better description of the flow conditions within the rod bundle. For LWR applications, a good representation of the two phase flow within the fuel assembly is necessary in order to have a best estimate calculation of the heat transfer inside the bundle. In this paper we present the coupling methodology of TRANSURANUS with KTF (Karlsruhe Two phase Flow subchannel code) as well as selected results of the coupling proof of principle. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Condensation in horizontal heat exchanger tubes

Many innovative reactor concepts for Generation III nuclear power plants use passive safety equipment for residual heat removal. These systems use two phase natural circulation. Heat transfer to the coolant results in a density difference providing the driving head for the required mass flow. By balancing the pressure drop the system finds its operational mode. Therefore the systems depend on a strong link between heat transfer and pressure drop determining the mass flow through the system. In order to be able to analyze these kind of systems with the help of state of the art computer codes the implemented numerical models for heat transfer, pressure drop or two phase flow structure must be able to predict the system performance in a wide parameter range. Goal of the program is to optimize the numerical models and therefore the performance of computer codes analyzing passive systems. Within the project the heat transfer capacity of a heat exchanger tube will be investigated. Therefore the tube will be equipped with detectors, both temperature and pressure, in several directions perpendicular to the tube axis to be able to resolve the angular heat transfer. In parallel the flow structure of a two phase flow inside and along the tube will be detected with the help of x-ray tomography. The water cooling outside of the tube will be realized by forced convection. It will be possible to combine the flow structure measurement with an angular resolved heat transfer for a wide parameter range. The test rig is set up at the TOPLFOW facility at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR), so that it will be possible to vary the pressure between 5 and 70 bar. The steam mass content will be varied between 0 and 100 percent. The results will be compared to the large scaled Emergency Condenser Tests performed at the INKA test facility in Karlstein (Germany). The paper will explain the test setup and the status of the project will be presented. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Results from One- and Two- Phase Fluid Flow Calculations within the Preliminary Safety Analysis of the Gorleben Site - 13310

Rock salt is one of the possible host rock formations for the disposal of high-level radioactive wastes in Germany. The Preliminary Safety Analysis of the Gorleben Site (Vorlaeufige Sicherheitsanalyse Gorleben, VSG) evaluates the long-term safety of a hypothetical repository in the salt dome of Gorleben, Germany. A mature repository concept and detailed knowledge of the site allowed a detailed process analysis within the project by numerical modeling of single-phase and two-phase flow. The possibility of liquid transport from the shafts to the emplacement drifts is one objective of the present study. Also, the implications of brine inflow on radionuclide transport and gas generation are investigated. Pressure build-up due to rock convergence and gas generation, release of volatile radionuclides from the waste and pressure-driven contaminant transport were considered, too. The study confirms that the compaction behavior of salt grit backfill is one of the most relevant factors for the hydrodynamic evolution of the repository and the transport of contaminants. Due to the interaction between compaction, saturation and pore pressure, complex flow patterns evolve. Emplacement drifts serve as gas sinks or sources at different times. In most calculation cases, the backfill reaches its final porosity after a few hundred years. The repository is then sealed and radionuclides can only be transported by diffusion in the liquid phase. Estimates for the final porosity of compacted backfill range between 0 % and 2 %. The exact properties of the backfill regarding single- and two-phase flow are not well known for this porosity range. The study highlights that this uncertainty has a profound impact on flow and transport processes over long time-scales. Therefore, more research is needed to characterize the properties of crushed salt grit at low porosities or to reduce the adverse effects of possible higher porosities by repository optimization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensitivity Studies of the Inter-subchannel Mixing in Subchannel Analysis

In the PWR reactor core, the power profile is nonuniform and the inter-subchannel mixing is of great importance for flatting the temperature distribution of the coolant and for reactor core safety analysis. Subchannel codes are widely used in the reactor core safety analysis to assess the thermal hydraulic behavior of fuel assemblies. One of basic assumptions in subchannel analysis is that axial flow predominates in the channel flow. Under this assumption, the lateral momentum equation in subchannel codes can be simplified without bringing in significant errors. The inter-subchannel mixing leading to the exchange of mass, energy and momentum are modeled by adding source terms to the hydrodynamic equations or by separate models, and most of source terms and models are empirical correlations. With the advancement of mixing vane grid design, the lateral mixing has becoming a critical components in the evaluation of the inter-subchannel mixing in flow field. The accuracy of the subchannel analysis is strongly dependent on the modeling of inter-subchannel interactions between adjacent subchannels. So the inter-subchannel mixing models should be well considered and developed in subchannel analysis to better reflect their influence on flow field and temperature field in rod bundle. Generally speaking, the inter-subchannel mixing in subchannel analysis contains turbulent mixing and crossflow mixing in single phase flow. When it comes to two phase flow, the void drift will also contribute to inter-subchannel mixing [2]. Both the mechanisms and the generation conditions of each type of inter-subchannel mixing are different from each other. Turbulent mixing is a result of random turbulent flow and pressure fluctuations. Crossflow is caused by a net transverse pressure difference between adjacent subchannels. Lateral pressure differences can result from different subchannel hydraulic diameters, mass flux, heat flux distributions and changes in flow areas caused, for example, by wire wraps and spacer grids, respectively. Two-phase void drift is due to the tendency of the vapor phase to redistribute itself to a preferred equilibrium void distribution. This paper focuses on the sensitivity study of the inter-subchannel mixing with mixing vane grids for single phase flow in subchannel analysis. Both the turbulent mixing and crossflow mixing of the 5 x 5 rod bundle with mixing vane grids are predicted, and the results are compared and analyzed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗