The Effect of Intensity-Modulated Radiotherapy on Radiation-Induced Second Malignancies

Purpose: To compare intensity-modulated radiotherapy (IMRT) with three-dimensional conformal radiotherapy (3D-CRT) in terms of carcinogenic risk for actual clinical scenarios. Method and Materials: Clinically equivalent IMRT plans were generated for prostate, breast, and head-and-neck cases treated with 3D-CRT. Two possible dose-response models for radiocarcinogenesis were generated based on A-bomb survivor data corrected for fractionation. Dose-volume histogram analysis was used to determine dose and its distribution to nontargeted tissues within the planning CT scan volume and thermoluminescent dosimetry for the rest of the body. Carcinogenic estimates were calculated with and without a correction factor accounting for cancer patients' advanced age and reduced longevity. Results: For the model assuming a plateau in risk above 2-Gy single-fraction-equivalent (SFE), IMRT and 3D-CRT produced risks of 1.7% and 2.1%, respectively, for prostate; 1.9% and 1.8%, respectively, for nasopharynx; 1% each for tonsil; and 1.4-2.2% and 1.5-1.6%, respectively, depending on technique, for breast. Assuming a reduction in risk above 2-Gy SFE, risks for IMRT and 3D-CRT were 1.1% and 1.5%, respectively, for prostate; 1.4% and 1.2%, respectively, for nasopharynx; 1% each for tonsil; and 1.3-1.8% vs. 1.3-1.6%, respectively, for breast. Applying a correction factor of 0.5 for cancer patients halved these risks and their relative differences. Conclusions: Carcinogenic risks were comparable in absolute terms between modalities. Risks are dependant on technique used. Risks with IMRT are influenced by monitor unit demand and are therefore software/hardware dependant. The dose-response model accounting for cell killing at higher doses fitted best with actual observed risks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric study of volumetric arc modulation with RapidArc and intensity-modulated radiotherapy in patients with cervical cancer and comparison with 3-dimensional conformal technique for definitive radiotherapy in patients with cervical cancer

Introduction: For patients with cervical cancer, intensity-modulated radiation therapy (IMRT) improves target coverage and allows dose escalation while reducing the radiation dose to organs at risk (OARs). In this study, we compared dosimetric parameters among 3-dimensional conformal radiotherapy (3D-CRT), “step-and-shoot” IMRT, and volumetric intensity-modulated arc radiotherapy (VMAT) in a series of patients with cervical cancer receiving definitive radiotherapy. Computed tomography (CT) scans of 10 patients with histologically proven cervical cancer treated with definitive radiation therapy (RT) from December 2008 to March 2010 at our department were selected for this study. The gross tumor volume (GTV) and clinical target volume (CTV) were delineated following the guidelines of the Gyn IMRT consortium that included cervix, uterus, parametrial tissues, and the pelvic nodes including presacral. The median age was 57 years (range: 30 to 85 years). All 10 patients had squamous cell carcinoma with Federation of Gynecology and Obstetrics (FIGO) stage IB-IIIB. All patients were treated by VMAT. OAR doses were significantly reduced for plans with intensity-modulated technique compared with 3D-CRT except for the dose to the vagina. Between the 2 intensity-modulated techniques, significant difference was observed for the mean dose to the small intestine, to the benefit of VMAT (p < 0.001). There was no improvement in terms of OARs sparing for VMAT although there was a tendency for a slightly decreased average dose to the rectum: − 0.65 Gy but not significant (p = 0.07). The intensity modulation techniques have many advantages in terms of quality indexes, and particularly OAR sparing, compared with 3D-CRT. Following the ongoing technologic developments in modern radiotherapy, it is essential to evaluate the intensity-modulated techniques on prospective studies of a larger scale.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multilayered microstructures with shape memory effects for vertical deployment

This paper presents a fabrication and characterization of multilayered microstructures with shape memory effects enabling large vertical deployment under electro-thermal actuation. Our previous research demonstrated vertical deployment of such microstructures by the effect of thermal mismatch. Development of equiatomic NiTi layers in the multilayered microstructure is investigated further for shape memory effects. Multilayered microstructures are built by sputtered NiTi layers and a lift-off process. Negative photoresist ma-N1420 enables clean lift-off of 500 nm thick NiTi layers by forming a significant undercut profile after development. The parametric study on co-sputter powers for Ti and Ni 50 Ti 50 targets suggests that 100 W RF on Ti target and 200 W DC on Ni 50 Ti 50 target can deposit Ni 49.62 Ti 50.38 layers. X-Ray Diffraction (XRD) and Atomic Force Microscopy (AFM) were used to study the crystal structures and surface topography of NiTi layers. XRD results of post-annealed Ni 49.62 Ti 50.38 layers show coexistence of austenite and martensitic phases at room temperature, suggesting that the transformation temperature of such NiTi layers should be approximate 20 °C. The surface topography of Ni 49.62 Ti 50.38 layers reveals substantial increase of surface roughness at ambient conditions after the annealing. Experimental verification of the multilayered microstructure for vertical deployment was carried out by Signatone Probe Station and Dual Scanning Electron Microscope/Focused Ion Beam (SEM/FIB) system. Finally, a vertical deployment of the two-dimensional (2D) multilayered microstructures for three-dimensional (3D) can be detected by applying a constant voltage of 0.04 V, and the expected 3D deployment displacement is enlarged from 2 μm to 10 μm by introducing the shape memory effect.

42 ENGINEERING↗

Effects of microalloying with 3d transition metals on glass formation in AlYFe alloys

The effects of microalloying on glass formation and stability were systematically investigated by substituting 0.5 at.% of all 3d transition metals for Al in Al{sub 88}Y{sub 7}Fe{sub 5} alloys. X-ray diffraction and isothermal differential scanning calorimetry studies indicate that samples containing microadditions of Ti, V, Cr, Mn, Fe and Co were amorphous, while those alloyed with Ni and Cu were not. The onset temperatures for crystallization (devitrification) of the amorphous alloys were increased with microalloying and some showed a supercooled liquid region ({Delta}T{sub x} = T{sub x} - T{sub g}) of up to 40 C. In addition, microalloying changes the glass structure and the devitrification sequence, as determined by differential scanning calorimetry (DSC), X-ray diffraction (XRD), transmission electron microscopy (TEM), differential thermal analysis (DTA) and high energy X-ray diffraction. The results presented here suggest that the order induced in the alloy by the transition metal microaddition decreases the atomic mobility in the glass and raises the barrier for the nucleation of {alpha}-Al, the primary devitrifying phase in most cases. New intermetallic phases also appear with microalloying and vary for different transition metal additions.

36 MATERIALS SCIENCE↗

A deep learning approach for semantic segmentation of unbalanced data in electron tomography of catalytic materials

In computed TEM tomography, image segmentation represents one of the most basic tasks with implications not only for 3D volume visualization, but more importantly for quantitative 3D analysis. In case of large and complex 3D data sets, segmentation can be an extremely difficult and laborious task, and thus has been one of the biggest hurdles for comprehensive 3D analysis. Heterogeneous catalysts have complex surface and bulk structures, and often sparse distribution of catalytic particles with relatively poor intrinsic contrast, which possess a unique challenge for image segmentation, including the current state-of-the-art deep learning methods. To tackle this problem, we apply a deep learning-based approach for the multi-class semantic segmentation of a γ-Alumina/Pt catalytic material in a class imbalance situation. Specifically, we used the weighted focal loss as a loss function and attached it to the U-Net’s fully convolutional network architecture. We assessed the accuracy of our results using Dice similarity coefficient (DSC), recall, precision, and Hausdorff distance (HD) metrics on the overlap between the ground-truth and predicted segmentations. Our adopted U-Net model with the weighted focal loss function achieved an average DSC score of 0.96 ± 0.003 in the γ-Alumina support material and 0.84 ± 0.03 in the Pt NPs segmentation tasks. We report an average boundary-overlap error of less than 2 nm at the 90th percentile of HD for γ-Alumina and Pt NPs segmentations. The complex surface morphology of γ-Alumina and its relation to the Pt NPs were visualized in 3D by the deep learning-assisted automatic segmentation of a large data set of high-angle annular dark-field (HAADF) scanning transmission electron microscopy (STEM) tomography reconstructions.

36 MATERIALS SCIENCE↗

Matrix phased arrays for the inspection of CFRP-components

Lightweight components are increasingly used in different industrial sectors such as transportation, energy generation and automotive. This growing field includes different types of CFRP-structures, hybrid materials and glued components showing - compared to their pure metallic counterparts- a significant more complicated structure in terms of internal interfaces and anisotropy of material parameters. In this work we present the use of matrix phased array to increase the amount of obtained information to enhance the inspection quality. We used different types of carbon materials such as 6 mm thick uni- and bidirectional prepreg specimens containing impact damages. The latter were introduced with different energy levels ranging from 1.3 to 7.2 J. By scanning a 2.25 MHz matrix array with 6 × 10 elements above the prepreg surface and using different angels of incidence a complete 3D-image was generated which allows the detection of defects as small as 1mm in a depth of 4 mm. A comparison with conventional approaches show that the signal-to-noise ratio can be highly increased. This enables us to visualize the region of damage within the impact zone, clearly showing the cone-like damage distribution along increasing material depth. The detection quality allows the estimation of the opening angles of the cone shaped damage, which can be used for further evaluation and quantitation of energy dependent impact damages.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Depth-resolved registration of transesophageal echo to x-ray fluoroscopy using an inverse geometry fluoroscopy system

Purpose: Image registration between standard x-ray fluoroscopy and transesophageal echocardiography (TEE) has recently been proposed. Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system designed for cardiac procedures. This study presents a method for 3D registration of SBDX and TEE images based on the tomosynthesis and 3D tracking capabilities of SBDX. Methods: The registration algorithm utilizes the stack of tomosynthetic planes produced by the SBDX system to estimate the physical 3D coordinates of salient key-points on the TEE probe. The key-points are used to arrive at an initial estimate of the probe pose, which is then refined using a 2D/3D registration method adapted for inverse geometry fluoroscopy. A phantom study was conducted to evaluate probe pose estimation accuracy relative to the ground truth, as defined by a set of coregistered fiducial markers. This experiment was conducted with varying probe poses and levels of signal difference-to-noise ratio (SDNR). Additional phantom and in vivo studies were performed to evaluate the correspondence of catheter tip positions in TEE and x-ray images following registration of the two modalities. Results: Target registration error (TRE) was used to characterize both pose estimation and registration accuracy. In the study of pose estimation accuracy, successful pose estimates (3D TRE < 5.0 mm) were obtained in 97% of cases when the SDNR was 5.9 or higher in seven out of eight poses. Under these conditions, 3D TRE was 2.32 ± 1.88 mm, and 2D (projection) TRE was 1.61 ± 1.36 mm. Probe localization error along the source-detector axis was 0.87 ± 1.31 mm. For the in vivo experiments, mean 3D TRE ranged from 2.6 to 4.6 mm and mean 2D TRE ranged from 1.1 to 1.6 mm. Anatomy extracted from the echo images appeared well aligned when projected onto the SBDX images. Conclusions: Full 6 DOF image registration between SBDX and TEE is feasible and accurate to within 5 mm. Future studies will focus on real-time implementation and application-specific analysis.

60 APPLIED LIFE SCIENCES↗

PRESSURE-FILM OPEN SOURCE SCANNING AND MAPPING

SF-22-099 Pressure-film Open Source Scanning and Mapping (POSSM) is software that analyses images of pressure-film (scans or photographs). POSSM collects data from that analysis in order to produce a number of visual aides, including pressure maps, histograms, and 3d surface plots. POSSM is designed to be able to analyze an entire folder full of images, exporting numeric data as .csv files and visual graphics as .png files.

Grider, Patrick↗

Development of 3D Geological Model of Tuscarora Sandstone for Feasibility of Deep Direct-Use Geothermal at West Virginia University Main Campus

The subsurface uncertainty at West Virginia University Main Campus is dominated by the uncertainty in the projections of geofluid flowrate in the target formation, the Tuscarora Sandstone. In this paper, three cores from the heterogeneous reservoir, available through West Virginia Geologic and Economic Survey, are analyzed by performing core analysis using CT scanning and permeability measurements via minipermeameter. Additional geological data are collected through cores, published literature, seismic data, and nearby, existing wells to estimate thickness, fracture network configuration and geothermal gradient to minimize the uncertainty of well deliverability. Using these estimated reservoir properties; a 3D conceptual model for the proposed geothermal site is developed. This dataset includes a GRC conference publication along with the data used to produce results explained in the paper including minipermeability measurement data for Preston -119 core and thin section analysis photos and data for Clay-513 core.

15 GEOTHERMAL ENERGY↗

Biosynthesis, Microstructural Characterisations and Investigation of In-Vitro Mutagenic and Eco-Toxicological Response of a Novel Microbial Exopolysaccharide Based Biopolymer

A modified microbial polysaccharide based biopolymer has been investigated as a potential candidate towards development of sustainable biomaterials and bioplastics. An in-depth study was carried out to biosynthesize, characterize and assess any possible mutagenic potential and ecotoxicity of the microbial polysaccharide biopolymer. Microstructural investigations using confocal microscopy, Fourier transform (FT)-Raman depth profile mapping and scanning electron microscopy (SEM) of the biosynthetically modified polysaccharide revealed internal structural perturbations, as well as occlusion of granular pores by extraneous materials. The Raman 3D mapping depth profile along with time-of-flight (MALDI-TOF) mass spectrometry also indicated important structural and surface modifications, which could be correlated to the production of microbial exopolysaccharides and secondary metabolites. The study then looked into any possible genetic mutation and ecological risks associated with the biosynthetically modified polysaccharide through the investigation of genotoxicity and ecotoxicity. The genotoxicity study was carried out through bacterial reverse gene mutation (Ames) test by using two different strains (TA98 and TA100) of bacteria. The results did not indicate any mutagenic effect against either of the strains used for the biopolymer samples and was found to be genotoxically safe. Ecotoxicity tests, carried out using bioluminescent bacteria Vibrio fisheri further indicated no ecotoxicity within the given experimental conditions. The study measured the half maximal effective concentration (EC50) to cause a 50% decrease in the light output of the bacteria, a measure of ecotoxicological response of the biopolymer. Overall, results from this study indicated that the novel biopolymer was genotoxically and ecotoxically safe, which offers immense potential for future use of this biopolymer.

36 MATERIALS SCIENCE↗

Dislocation mechanisms and 3D twin architectures generate exceptional strength-ductility-toughness combination in CrCoNi medium-entropy alloy

Combinations of high strength and ductility are hard to attain in metals. Exceptions include materials exhibiting twinning-induced plasticity. To understand how the strength-ductility trade-off can be defeated, we apply in situ, and aberration-corrected scanning, transmission electron microscopy to examine deformation mechanisms in the medium-entropy alloy CrCoNi that exhibits one of the highest combinations of strength, ductility and toughness on record. Ab initio modelling suggests that it has negative stacking-fault energy at 0K and high propensity for twinning. With deformation we find that a three-dimensional (3D) hierarchical twin network forms from the activation of three twinning systems. This serves a dual function: conventional twin-boundary (TB) strengthening from blockage of dislocations impinging on TBs, coupled with the 3D twin network which offers pathways for dislocation glide along, and cross-slip between, intersecting TB-matrix interfaces. The stable twin architecture is not disrupted by interfacial dislocation glide, serving as a continuous source of strength, ductility and toughness.

36 MATERIALS SCIENCE↗

Resolving atomic transport through iron oxide under irradiation using isotopic tracers

Structural materials in nuclear environments are exposed to complex and harsh conditions, including high temperatures, corrosive solutions, and irradiation. Material stability and likewise degradation are fundamentally controlled by atomic transport mechanisms. Here, we investigate the influence of radiation-induced, non-equilibrium point defect populations on mass transport within model oxide systems using isotopic tracers and atom probe tomography. An isotopically labelled hematite (a-Fe2O3) film was synthesized with 16O- and 18O-rich layers (>30nm and 10 nm, respectively) sequentially deposited via molecular beam epitaxy. One region of the film was proton irradiated to ~0.1 dpa at 450°C, and regions outside the beam spot provided a non-irradiated control of thermal annealing only. 3D APT was used to directly visualize the elemental and O-isotopic redistribution following both thermal and combined thermal and irradiation conditions. Complementary scanning transmission electron microscopy (STEM) was also employed to study the microstructural evolution. Error function fits of the 18O-concentration profiles enabled quantification of diffusion coefficients.

isotopic tracers, diffusion, proton irradiation, h↗

Time of Flight Secondary Ion Mass Spectrometry for Characterization of Pt-Coated Porous Transport Layers in PEM Water Electrolyzers

Titanium-based porous transport layers (PTLs) and iridium-based catalyst layers (CLs) are two main components of proton exchange membrane water electrolyzers (PEMWEs). PTLs are typically coated with platinum to minimize interfacial losses and to support long-term operation. Optimizing coatings and the PTL-CL interface requires comprehensive characterization. This study establishes time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a valuable technique for PTL characterization, addressing capabilities and limitations related to PTL morphology. A methodology was developed that uses a Cs + sputter beam for dynamic depth profiling, with data collected in both positive-ion (MCs + ) and negative-ion modes to generate depth profiles, 2D ion maps, and 3D ion reconstructions. ToF-SIMS detected relative differences in platinum-layer thickness between samples; these trends were validated by cross-sectional scanning transmission electron microscope (STEM) measurements and flat-titanium substrate controls. Interfacial oxide layers are identified in both ion modes, with enhanced oxide sensitivity in negative mode. The technique’s high sensitivity enables detection of nanometer-scale coatings and trace impurities within the bulk PTL structure. These results provide a methodological framework for analyzing Pt-coated PTLs, with the potential to extend to other components in PEMWEs and other electrolyzer systems.

36 MATERIALS SCIENCE↗

SU-F-J-54: Towards Real-Time Volumetric Imaging Using the Treatment Beam and KV Beam

Purpose: Existing real-time imaging uses dual (orthogonal) kV beam fluoroscopies and may result in significant amount of extra radiation to patients, especially for prolonged treatment cases. In addition, kV projections only provide 2D information, which is insufficient for in vivo dose reconstruction. We propose real-time volumetric imaging using prior knowledge of pre-treatment 4D images and real-time 2D transit data of treatment beam and kV beam. Methods: The pre-treatment multi-snapshot volumetric images are used to simulate 2D projections of both the treatment beam and kV beam, respectively, for each treatment field defined by the control point. During radiation delivery, the transit signals acquired by the electronic portal image device (EPID) are processed for every projection and compared with pre-calculation by cross-correlation for phase matching and thus 3D snapshot identification or real-time volumetric imaging. The data processing involves taking logarithmic ratios of EPID signals with respect to the air scan to reduce modeling uncertainties in head scatter fluence and EPID response. Simulated 2D projections are also used to pre-calculate confidence levels in phase matching. Treatment beam projections that have a low confidence level either in pre-calculation or real-time acquisition will trigger kV beams so that complementary information can be exploited. In case both the treatment beam and kV beam return low confidence in phase matching, a predicted phase based on linear regression will be generated. Results: Simulation studies indicated treatment beams provide sufficient confidence in phase matching for most cases. At times of low confidence from treatment beams, kV imaging provides sufficient confidence in phase matching due to its complementary configuration. Conclusion: The proposed real-time volumetric imaging utilizes the treatment beam and triggers kV beams for complementary information when the treatment beam along does not provide sufficient confidence for phase matching. This strategy minimizes the use of extra radiation to patients. This project is partially supported by a Varian MRA grant.

60 APPLIED LIFE SCIENCES↗

Vertical nanoscale strain-induced electronic localization in epitaxial La2/3Sr1/3MnO3 films with ZrO2 nanopillar inclusions

Abstract Unusual electrical transport properties associated with weak or strong localization are sometimes found in disordered electronic materials. Here, we report experimental observation of a crossover of electronic behavior from weak localization to enhanced weak localization due to the spatial influence of disorder induced by ZrO 2 nanopillars in (La 2/3 Sr 1/3 MnO 3 ) 1− x :(ZrO 2 ) x ( x = 0, 0.2, and 0.3) nanocomposite films. The spatial strain regions, identified by scanning transmission electron microscopy and high-resolution x-ray diffraction, induce a coexistence of two-dimentional (2D) and three-dimentional (3D) localization and switches to typical 2D localization with increasing density of ZrO 2 pillars due to length scale confinement, which interestingly accords with enhancing vertically interfacial strain. Based on the excellent agreement of our experimental results with one-parameter scaling theory of localization, the enhanced weak localization exists in metal range close to the fixed point. These films provide a tunable experimental model for studying localization in particular the transition regime by appropriate choice of the second epitaxial phase. Graphical Abstract

36 MATERIALS SCIENCE↗

Relaxation processes in a low-order three-dimensional magnetohydrodynamics model

The time asymptotic behavior of a Galerkin model of 3D magnetohydrodynamics (MHD) has been interpreted using the selective decay and dynamic alignment relaxation theories. A large number of simulations has been performed that scan a parameter space defined by the rugged ideal invariants, including energy, cross helicity, and magnetic helicity. It is concluded that time asymptotic state can be interpreted as a relaxation to minimum energy. A simple decay model, based on absolute equilibrium theory, is found to predict a mapping of initial onto time asymptotic states, and to accurately describe the long time behavior of the runs when magnetic helicity is present. Attention is also given to two processes, operating on time scales shorter than selective decay and dynamic alignment, in which the ratio of kinetic to magnetic energy relaxes to values 0(1). The faster of the two processes takes states initially dominant in magnetic energy to a state of near-equipartition between kinetic and magnetic energy through power law growth of kinetic energy. The other process takes states initially dominant in kinetic energy to the near-equipartitioned state through exponential growth of magnetic energy.

Stribling, Troy↗

Enhanced copper micro/nano-particle mixed paste sintered at low temperature for 3D interconnects

An enhanced copper paste, formulated by copper micro- and nano-particles mixture, is reported to prevent paste cracking and obtain an improved packing density. The particle mixture of two different sizes enables reduction in porosity of the micro-paste and resolves the cracking issue in the nano-paste. In-situ temperature and resistance measurements indicate that the mixed paste has a lower densification temperature. Electrical study also shows a ∼12× lower sheet resistance of 0.27 Ω/sq. In addition, scanning electron microscope image analysis confirms a ∼50% lower porosity, which is consistent with the thermal and electrical results. The 3:1 (micro:nano, wt. %) mixed paste is found to have the strongest synergistic effect. This phenomenon is discussed further. Consequently, the mixed paste is a promising material for potential low temperature 3D interconnects fabrication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of pore structures and cracking in cement paste exposed to elevated temperatures by X-ray computed tomography

When cement-based materials are exposed to the high temperatures induced by fire, which can rapidly cause temperatures of over 1000 °C, the changes in pore structure and density prevail. In the present study, mortar specimens were subjected to a series of increasing temperatures to explore the temperature-dependent evolution of internal pore structure. High-performance X-ray computed tomography (CT) was used to observe the evolution of temperature-induced discontinuities at the sub-millimeter level. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were employed to investigate the cause of physical changes in the heated mortar specimens. Results exhibit the changes in pore structure caused by elevated temperatures, and thermally induced fractures. We discuss the progressive formation of thermally induced fracture networks, which is a prerequisite for spalling failure of cement-based materials by fire, based on visual observations of the 3D internal structures revealed by X-ray CT.