Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Insight into the deformation features and capacity loss mechanisms of lithium-ion pouch cells under spherical indentation conditions

Mechanical deformation under extreme conditions is one of the important reasons for the failure of lithium-ion batteries in automotive application. However, the deformation features and component failure of lithium-ion cells to external loading has never been a design consideration. Here, in this study, we conduct spherical indentation tests on a dozen of lithium-ion cells with different capacities under different control mode conditions to investigate their deformation features and capacity loss mechanisms. The experimental results show that, under mechanical deformation conditions, internal faults of cells occur in stages, and energy accumulation and sudden release are two key processes of cell's mechanical failure. The cells' state of charge is the main factor affecting their thermal runaway behaviors. In addition, a finite element model is developed to simulate the deformation features and the failure mechanism of key components of lithium-ion pouch cells; the 3D x-ray computed tomography is employed to demonstrate its internal configuration. With this model, the force-strain response, the deformation features as well as the size of the failure area of lithium-ion cells under spherical indentation conditions are accurately predicted. In 3D x-ray computed tomography images, unique mud cracks in cooper current collector are observed, and the influence mechanisms of the isolated fragments on the cell capacities are revealed. These results may provide useful information for the mechanical structure design of the components of lithium-ion pouch cells.

25 ENERGY STORAGE↗

Merging of high speed argon plasma jets

Formation of an imploding plasma liner for the plasma liner experiment (PLX) requires individual plasma jets to merge into a quasi-spherical shell of plasma converging on the origin. Understanding dynamics of the merging process requires knowledge of the plasma phenomena involved. We present results from the study of the merging of three plasma jets in three dimensional geometry. The experiments were performed using HyperV Technologies Corp. 1 cm Minirailguns with a preionized argon plasma armature. The vacuum chamber partially reproduces the port geometry of the PLX chamber. Diagnostics include fast imaging, spectroscopy, interferometry, fast pressure probes, B-dot probes, and high speed spatially resolved photodiodes, permitting measurements of plasma density, temperature, velocity, stagnation pressure, magnetic field, and density gradients. These experimental results are compared with simulation results from the LSP 3D hybrid PIC code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Establishing an Urban Heat Exposure Severity Index for Infrastructure Prioritization in Tempe, Arizona, Using NASA Earth Observations and LiDAR

Located on the banks of the Salt River in the Sonoran Desert, Tempe, Arizona, features a semi-arid climate with summer daily maximum temperatures regularly exceeding 37.8°C. Tempe is also subject to the southwestern monsoon season from July-September and the humidity exacerbates the high temperatures. Furthermore, the rapid urbanization experienced in Tempe has resulted in an intensification of the urban heat island. The summer of 2020 shattered the previous record of days exceeding 43.4°C, leading to higher energy and water costs, lower comfort, and increased risk of heat stroke for residents. Recognizing the impacts of extreme heat, the City of Tempe partnered with the Healthy Urban Environments initiative and NASA DEVELOP to identify census tracts that experience a higher mean land surface temperature than the city average. The NASA DEVELOP team used remotely sensed land surface temperature (LST), normalized difference vegetation index (NDVI), normalized difference built-up index (NDBI), normalized difference water index (NDWI), and albedo data calculated from Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) and Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) instruments from 2015 to 2020 to create heat hazard and exposure maps. LiDAR point cloud data, provided by the United States Geological Survey through Arizona State University’s Map and Geospatial Hub, were used to derive 3D buildings, building footprints, and tree point data for a shading analysis of walking paths, roads, and buildings at the census tract level. In situ meteorological measurements including air temperature and humidity were used to compare the macro-scale temperature measurements. The team worked with the City of Tempe to develop a methodology to process available data and identify areas of highest concern for urban heat effects within the city. With these insights, Tempe, Arizona can better address these issues with data-driven information to make decisions regarding heat mitigation and adaptation efforts.

John Dialesandro↗

Analysis of moisture migration in concrete at high temperature through in-situ neutron tomography

Spalling, which is a phenomenon encountered when high-performance concrete is exposed to high temperature, can lead to large economical damage and can be a major safety hazard. Moisture distribution in concrete during exposure to fire is of paramount importance for understanding the complex mechanism of this phenomenon. To capture in its fullness this mechanism, it is crucial to account for the heterogeneous nature of concrete. In this paper, the first 3D analysis of moisture distribution in concrete at high temperature through in-situ neutron tomography is presented. The world-leading flux at the Institute Laue Langevin in Grenoble, France allowed capturing one 3D scan per minute, which is sufficient to follow the fast dehydration process. The paper describes the experimental setup with the heating system and discusses in detail the framework of the neutron tomography test. Quantitative analysis showing the effect of the aggregate size on the moisture distribution is presented.

36 MATERIALS SCIENCE↗

Three-dimensional (3D) microstructural characterization and quantification of reflow porosity in Sn-rich alloy/copper joints by X-ray tomography

In this paper high resolution X-ray tomography was used to characterize reflow porosity in Sn-3.9Ag-0.7Cu/Cu solder joints. The combination of two segmentation techniques was applied for the three-dimensional (3D) visualization of pores in the joints and the quantification on the characteristics of reflow porosity, including pore size, volume fraction and morphology. The size, morphology and distribution of porosity were visualized in 3D for three different solder joints. Since the results are relatively similar for all three, only the results of one joint are presented. Solder reflow porosity was mostly spherical, segregated along the solder/Cu interface, and had an average pore size of 30 {mu}m in diameter. A few large pores (larger than 100 {mu}m in diameter) were present, some of which had lower sphericity, i.e., they were more irregular. The presence of these large pores may significantly influence the mechanical behavior of solder joints. - Highlights: {yields} Non-destructive 3D characterization and quantification of porosity in Pb-free solders by X-ray tomography {yields} Two new image analysis and reconstruction tools are presented that can be used by the community at large {yields} Pore size, volume fraction, and sphericity, is critical to understanding microstructure and modeling of these systems.

36 MATERIALS SCIENCE↗

Discerning the Location and Nature of Coke Deposition from Surface to Bulk of Spent Zeolite Catalysts

The nanoscale compositional mapping of fresh HZSM-5 catalyst synthesized using hydrothermal process as well as after just steaming and after ethanol conversion reaction for 72 hours at realistic catalytic conditions was investigated using atom probe tomography. Atom probe tomography permitted direct atomic scale imaging of non-uniform distribution of Al within the HZSM-5 as well as for the first time image the hydrocarbon coking after ethanol reaction. Clear evidences for existence of multiple C-H molecular species which appear to aggregate as clusters within the pores of spent HZSM-5 catalyst materials is provided. Furthermore, these results provide evidence for the ability of atom probe tomography, a powerful 3D characterization tool in interrogating the atomic scale chemistry of zeolite catalyst materials at industrially relevant catalytic conditions.

54 ENVIRONMENTAL SCIENCES↗

SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.

60 APPLIED LIFE SCIENCES↗

Scaling Building Energy Audits through Machine Learning Methods on Novel Drone Image Data

Building energy audits are time-consuming and labor-intensive. This paper describes a new method using machine learning (ML) techniques on novel data sources (drone images) to improve the identification of building characteristics and retrofit opportunities, and thereby reduce the effort for audits. The new ML method includes: (1) Building footprint extraction using line extraction, polygonization, and polygon-merging, (2) Building envelope extraction using PIX4d modeling software to reconstruct a building 3D model, (3) Visualization tool for viewing images from the 3D model, (4) Window-to-wall ratio (WWR) using state-of-art deep neural network semantic segmentation, (5) Envelope thermal anomaly detection using an unsupervised machine learning clustering algorithm, and (6) Rooftop energy equipment detection based on an object detection algorithm. The testing of this method involved a comparison of additional ML-generated information overlaid on current ‘state-of-practice’ audit and remote assessment baselines using evaluation metrics: labor time and associated cost, marginal benefits of using ML-generated information in workflows for audits and remote assessments, integration potential with existing processes and tools, and replicability/scalability of the method. In two test buildings in California that had comprehensive drawings and meter data available, the ML method effectively generated a building footprint, envelope, rooftop equipment, WWR, and locations of envelope thermal anomalies. Projected target segments of the ML method are sites with minimal drawings and energy data, and underserved sectors such as multistoried housing, disadvantaged communities, and schools for which the ML method can enable identification of building asset characteristics and prioritization of envelope retrofits and decentralized energy equipment retrofits.

Singh, Reshma↗

TH-EF-BRA-04: Individually Optimized Contrast-Enhanced 4D-CT for Radiotherapy Simulation in Pancreatic Ductal Adenocarcinoma

Purpose: To develop an individually optimized contrast-enhanced (CE) 4D-CT for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). Methods: Ten PDA patients were enrolled. Each underwent 3 CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT using test injection. Three physicians contoured the tumor and pancreatic tissues. We compared image quality scores, tumor volume, motion, tumor-to-pancreas contrast, and contrast-to-noise ratio (CNR) in the 3 CTs. We also evaluated interobserver variations in contouring the tumor using simultaneous truth and performance level estimation (STAPLE). Results: Average image quality scores for CE 3DCT and CE 4D-CT were comparable (4.0 and 3.8, respectively; P=0.47), and both were significantly better than that for 4D-CT (2.6, P<0.001). Tumor-to-pancreas contrast results were comparable in CE 3D-CT and CE 4D-CT (15.5 and 16.7 HU, respectively; P=0.71), and the latter was significantly higher than in 4D-CT (9.2 HU, P=0.03). Image noise in CE 3D-CT (12.5 HU) was significantly lower than in CE 4D-CT (22.1 HU, P<0.001) and 4D-CT (19.4 HU, P=0.005). CNRs were comparable in CE 3D-CT and CE 4DCT (1.4 and 0.8, respectively; P=0.23), and the former was significantly better than in 4D-CT (0.6, P = 0.04). Mean tumor volumes were smaller in CE 3D-CT (29.8 cm{sup 3}) and CE 4D-CT (22.8 cm{sup 3}) than in 4D-CT (42.0 cm{sup 3}), although these differences were not statistically significant. Mean tumor motion was comparable in 4D-CT and CE 4D-CT (7.2 and 6.2 mm, P=0.23). Interobserver variations were comparable in CE 3D-CT and CE 4D-CT (Jaccard index 66.0% and 61.9%, respectively) and were worse for 4D-CT (55.6%) than CE 3D-CT. Conclusion: CE 4D-CT demonstrated characteristics comparable to CE 3D-CT, with high potential for simultaneously delineating the tumor and quantifying tumor motion with a single scan. Supported in part by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Three-dimensional Image Fusion Guidance for Transjugular Intrahepatic Portosystemic Shunt Placement

IntroductionTo assess the safety, feasibility and effectiveness of image fusion guidance with pre-procedural portal phase computed tomography with intraprocedural fluoroscopy for transjugular intrahepatic portosystemic shunt (TIPS) placement.Materials and methodsAll consecutive cirrhotic patients presenting at our interventional unit for TIPS creation from January 2015 to January 2016 were prospectively enrolled. Procedures were performed under general anesthesia in an interventional suite equipped with flat panel detector, cone-beam computed tomography (CBCT) and image fusion technique. All TIPSs were placed under image fusion guidance. After hepatic vein catheterization, an unenhanced CBCT acquisition was performed and co-registered with the pre-procedural portal phase CT images. A virtual path between hepatic vein and portal branch was made using the virtual needle path trajectory software. Subsequently, the 3D virtual path was overlaid on 2D fluoroscopy for guidance during portal branch cannulation. Safety, feasibility, effectiveness and per-procedural data were evaluated.ResultsSixteen patients (12 males; median age 56 years) were included. Procedures were technically feasible in 15 of the 16 patients (94%). One procedure was aborted due to hepatic vein catheterization failure related to severe liver distortion. No periprocedural complications occurred within 48 h of the procedure. The median dose-area product was 91 Gy cm{sup 2}, fluoroscopy time 15 min, procedure time 40 min and contrast media consumption 65 mL. Clinical benefit of the TIPS placement was observed in nine patients (56%).ConclusionThis study suggests that 3D image fusion guidance for TIPS is feasible, safe and effective. By identifying virtual needle path, CBCT enables real-time multiplanar guidance and may facilitate TIPS placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Directing Matter: Toward Atomic-Scale 3D Nanofabrication

Here we report that enabling memristive, neuromorphic, and quantum based computing as well as efficient mainstream energy storage and conversion technologies requires next generation of materials customized at the atomic scale. This requires full control of atomic arrangement and bonding in three dimensions. The last two decades witnessed substantial industrial, academic, and government research efforts directed towards this goal through various lithographies and scanning probe based methods. These technologies emphasize 2D surface structures, with some limited 3D capability. Recently, a range of focused electron and ion based methods have demonstrated compelling alternative pathways to achieving atomically precise manufacturing of 3D structures in solids, liquids, and at interfaces. Electron and ion microscopies offer a platform that can simultaneously observe dynamic and static structures at the nano and atomic scales, and also induce structural rearrangements and chemical transformation. The addition of predictive modeling or rapid image analytics and feedback enables guiding these in a controlled manner. Here, we review the recent results that used focused electron and ion beams to create free-standing nanoscale 3D structures, radiolysis and the fabrication potential with liquid precursors, epitaxial crystallization of amorphous oxides with atomic layer precision, as well as visualization and control of individual dopant motion within a 3D crystal lattice. These works lay the foundation for new approaches to directing nanoscale level architectures and offer a potential roadmap to full 3D atomic control in materials. Lastly, in this perspective we lay out the gaps that currently constrain the processing range of these platforms, reflect on indirect requirements, such as the integration of large scale data analysis with theory, and discuss future prospects of these technologies.

36 MATERIALS SCIENCE↗

Nonambipolar Transport due to Electrons with 3D Resistive Response in the KSTAR Tokamak

A small nonaxisymmetric (3D) magnetic field can induce nonambipolar transport of the particle species confined in a tokamak and thus a significant change of plasma rotation. This process can be in a favor of instability control in the region where the tokamak plasma is sufficiently collisional and resistive, as observed in the applications of $n$ = 1 resonant magnetic perturbations to the KSTAR tokamak. The plasma rotation can be globally accelerated due to radially drifting electrons and constrained to the electron root, if the radial transport is enhanced by an amplified 3D response. Interestingly, this mechanism is verified by a kinetically self-consistent magnetohydrodynamic modeling for both response and transport, which offers the quantitative explanations on the internal $n$ = 1 structure detected by electron-cyclotron-emission imaging and the cocurrent plasma spinning observed in the experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-48: Automated Quality Assurance for XML Controlled Linacs

Purpose: To automate routine imaging QA procedures so that complying with TG 142 and TG 179 can be efficient and reliable. Methods: Two QA tests for a True Beam Linac were automatized. A Winston Lutz test as described by Lutz et al{sup 1} using the Winston Lutz test kit from BrainLab, Germany and a CBCT Image Quality test as described in TG 179 using the EMMA phantom, Siemens Medical Physics, Germany were performed in our True Beam. For each QA procedure tested, a 3 step paradigm was used. First, the data was automatically acquired using True Beam Developer Mode and XML scripting. Second, the data acquired in the first step was automatically processed using in-home grown Matlab GUIs. Third, Machine Learning algorithms were used to automatically classify the processed data and reports generated. Results: The Winston Luzt test could be performed by an experienced medical physicist in 29.0 ± 8.0 min. The same test, if automated using our paradigm, could be performed in 3.0 ± 0.1 min. In the same lieu, time could be substantially saved for image quality tests. In this case, the amount of time saved will depend on the phantoms used and the initial localization method. Additionally, machine learning algorithms could automatically identify the roots of the problems if any and possibly help reduce machine down time. Conclusion: Modern linear accelerators are equipped with advanced 2D and 3D imaging that are used for patient alignment substantially improving IGRT protocols. However, this extra complexity exponentially increases the number of QA tests needed. Using the new paradigm described above, not only bare minimum but best practice QA programs could be implemented with the same manpower. This work is supported by Varian, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

A 3D contact analysis approach for the visualization of the electrical contact asperities

The electrical contact is an important phenomenon that should be given into consideration to achieve better performance and long term reliability for the design of devices. Based upon this importance, the electrical contact interface has been visualized as a “3D Contact Map” and used in order to investigate the contact asperities. The contact asperities describe the structures above and below the contact spots (the contact spots define the 3D contact map) to the two conductors which make the contact system. The contact asperities require the discretization of the 3D microstructures of the contact system into voxels. A contact analysis approach has been developed and introduced in this paper which shows the way to the 3D visualization of the contact asperities of a given contact system. For the discretization of 3D microstructure of contact system into voxels, X-ray Computed Tomography (CT) method is used in order to collect the data of a 250 V, 16 A rated AC single pole rocker switch which is used as a contact system for investigation.

47 OTHER INSTRUMENTATION↗

Investigation of the dynamic stress–strain response of compressible polymeric foam using a non-parametric analysis

Dynamic stress–strain response of rigid closed-cell polymeric foams is investigated in this work by subjecting high toughness polyurethane foam specimens to direct impact with different projectile velocities and quantifying their deformation response with high speed stereo-photography together with 3D digital image correlation. The measured transient displacement field developed in the specimens during high stain rate loading is used to calculate the transient axial acceleration field throughout the specimen. A simple mathematical formulation based on conservation of mass is also proposed to determine the local change of density in the specimen during deformation. By obtaining the full-field acceleration and density distributions, the inertia stresses at each point in the specimen are determined through a non-parametric analysis and superimposed on the stress magnitudes measured at specimen ends to obtain the full-field stress distribution. Furthermore, the process outlined above overcomes a major challenge in high strain rate experiments with low impedance polymeric foam specimens, i.e. the delayed equilibrium conditions can be quantified.

42 ENGINEERING↗

Algorithm-Driven Advances for Scientific CT Instruments: From model-based to deep learning-based approaches

Multiscale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (SCT) instruments are one of the most popular choices for 3D nondestructive characterization of materials at length scales ranging from the angstrom scale to the micron scale. These instruments typically have a source of radiation (such as electrons, X-rays, or neutrons) that interacts with the sample to be studied and a detector assembly to capture the result of this interaction (see Figure 1 ). A collection of such high-resolution measurements is made by reorienting the sample, which is mounted on a specially designed stage/holder after which reconstruction algorithms are used to produce the final 3D volume of interest. The specific choice of which instrument to use depends on the desired resolution and properties of the materials being imaged. Additionally, the end goal of SCT scans includes determining the morphology, chemical composition, or dynamic behavior of materials when subjected to external stimuli. In summary, SCT instruments are powerful tools that enable 3D characterization across multiple length scales and play a critical role in furthering the understanding of the structure–function relationships of different materials.

42 ENGINEERING↗

Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.

60 APPLIED LIFE SCIENCES↗

A Field-Deployable Magnetic Resonance Imaging Rhizotron for Modeling and Enhancing Root Growth and Biogeochemical Function

A collaborative team from Texas A&M AgriLife Research, ABQMR Inc., the Soil Health Institute, the Athinoula A. Martinos Center for Biomedical Imaging, and NIST developed low-field magnetic resonance imaging (LF-MRI) instrumentation capable of imaging intact soil-root systems. The system measured root biomass, architecture, 3D mass distribution, and growth rates, providing a non-destructive means to evaluate ideal plant characteristics based on root metrics. It also successfully generated three-dimensional images of soil water content, a key property influencing root growth and exploration. Operating much like an MRI used in a medical setting, the system functioned in field conditions without damaging plants, overcoming the limitations of traditional methods such as trenching, soil coring, and root excavation. Over the course of the project, the team designed and built three functional prototype systems. These prototypes provided new insights into root–water–soil interactions that drive processes such as nutrient uptake, water use, and carbon management. This information contributed to efforts to optimize plants for carbon sequestration without sacrificing economic yield. The project also supported the identification of desirable traits for energy sorghum, including high root growth rates, more vertical root angles, and enhanced drought resilience under water-limiting conditions.

09 BIOMASS FUELS↗