Novel wireless NDE sensors for continuous monitoring of thermal power plant components
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Rocket launches generate infrasound signatures that have been detected at great distances. Due to the sparsity of the networks that have made these detections, however, most signals are detected tens of minutes to hours after the rocket launch. In this work, a method of near-real-time detection of rocket launches using data from a network of smartphones located 10–70 km from launch sites is presented. A machine learning model is trained and tested on the open-access Aggregated Smartphone Timeseries of Rocket-generated Acoustics (ASTRA), Smartphone High-explosive Audio Recordings Dataset (SHAReD), and ESC-50 datasets, resulting in a final accuracy of 97% and a false positive rate of <1%. The performance and behavior of the model are summarized, and its suitability for persistent monitoring applications is discussed.
Surface Acoustic Wave (SAW) technology is low cost, rugged, lightweight, extremely low power and can be used to develop passive wireless sensors. For these reasons, NASA is investigating the use of SAW technology for Integrated Vehicle Health Monitoring (IVHM) of aerospace structures. To facilitate rapid prototyping of passive SAW sensors for aerospace applications, SAW models have been developed. This paper reports on the comparison of three methods of modeling SAWs. The three models are the Impulse Response Method (a first order model), and two second order matrix methods; the conventional matrix approach, and a modified matrix approach that is extended to include internal finger reflections. The second order models are based upon matrices that were originally developed for analyzing microwave circuits using transmission line theory. Results from the models are presented with measured data from devices. Keywords: Surface Acoustic Wave, SAW, transmission line models, Impulse Response Method.
A technique for using the longitudinal velocity (LV) of an ultrasonic wave to monitor the extent of cross linking (CL) during the cure of thermosetting resins is described. The method was developed by monitoring the rate of change in LV during the cure of a bisphenol-A epoxy resin with an amine adduct. The experiment included variations in the temperature and stoichiometry in order to express the rate of change in terms of the reaction kinetics. The pulse-echo method was used with a single transducer operating at 20 MHz. Numerical models were defined to account for the acoustic response of a single layer, the attenuation and the reflection coefficient. A linear relationship was observed between the inverse of the temperature and the log of the rate of change in the velocity, supporting the theory that the velocity could be used to monitor the extent of the cross-linking reaction. An activation energy of 11.9 kcal/mole was calculated for the mixture being investigated.
Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.
Here, this study outlines the development and testing of a flow meter prototype specifically designed for use in nuclear reactor environments. The meter uses flow-induced vibration to measure flow rates and is designed for remote monitoring in harsh environments where radiation can damage electronics. The device generates a vibration signal produced by a feedback system when fluid flows out of an orifice and interacts with a downstream wedge. The frequency of the vibration signal corresponds directly to flow rate and velocity. The study investigates geometric parameters intrinsic to the prototype, such as orifice height, width, edge distance, and chamber length. Different configurations were also tested, including a bypass loop with variable cross-sections around the device. The investigation results reveal the impact of these geometric parameters on the vibration signal output, providing valuable insights for future design improvements and enhancing the effectiveness of flow metering systems used in nuclear reactor applications.
Ultrasonic thermometry sensors (UTS) have been intensively studied in the past to measure temperatures from 2080 to 3380 K. This sensor, which uses the temperature dependence of acoustic velocity in materials, was developed for experiments in extreme environments. Its major advantages, which are (a) recording capability of a temperature profile deduced from the notches on the sensor rod and (b) measurement near the sensor material melting point, can be of great interest when dealing with on-line monitoring of high temperature safety tests. Ultrasonic techniques were successfully applied in several severe accident related experiments. If new developments are conducted with other materials, this sensor type may be used in a wide-range of experimental areas where robustness and compactness are required. Long-term irradiation experiments of nuclear fuel to extremely high burn-ups could benefit from this previous experience. After an overview of UTS technology, this paper summarizes experimental work performed to improve the reliability of these sensors. The various designs, advantages and drawbacks are outlined and future prospects for long term high temperature irradiation experiments are discussed.
Understanding fine-scale habitat selection of endangered Kootenai River white sturgeon ( Acipenser transmontanus) is an important component for monitoring and recovery efforts. Fine-scale habitat selection and quantifying temporal changes in suitable habitat contributes to the work of addressing recruitment failure within the Kootenai River population. Habitat suitability indices were developed using over 96 000 acoustic telemetry sturgeon detections and two-dimensional hydrodynamic model simulations near Bonners Ferry, Idaho, USA. The selected habitat was assessed to develop habitat suitability indices for sturgeon; females undergoing spawn migrations and non-spawners. The most frequented locations were 8–9 m deep and water velocities of 0.3–0.7 m·s −1 . These observations suggest sturgeon with different spawning capabilities selected similar habitat. Weighted usable area was calculated to understand temporal variability in habitat quality, which showed a positive relationship with increases in flow. Results help understand the habitat limiting factors in regulated hydrologic regimes; provide biologists insight for monitoring efforts in discrete habitat conditions; guidance for water managers and the regulation of upstream water resources; and guidance to restoration practitioners for in-stream structure designs.
This regards a high-resolution DAS microseismic dataset produced by Silixa from Utah FORGE Phase 2C seismic monitoring well 78-32 during stimulation testing of well 58-32. It is a very large dataset and as such it is currently not directly available on GDR. However, it is available for download from the Center for High Performance Computing (CHPC) at the University of Utah using the shell script below. Additional survey information and tips for running the script are available in the attached downloadable Word Document file.
Aluminum alloys pose several properties that make them one of the most popular engineering materials: they have excellent corrosion resistance, and high weight-to-strength ratio. Resistance spot welding of aluminum alloys is widely used today but oxide film and aluminum thermal and electrical properties make spot welding a difficult task. Electrode degradation due to pitting, alloying and mushrooming decreases the weld quality and adjustment of parameters like current and force is required. To realize these adjustments and ensure weld quality, a tool to measure weld quality in real time is required. In this paper, a real time ultrasonic non-destructive evaluation system for aluminum spot welds is presented. The system is able to monitor nugget growth while the spot weld is being made. This is achieved by interpreting the echoes of an ultrasound transducer located in one of the welding electrodes. The transducer receives and transmits an ultrasound signal at different times during the welding cycle. Valuable information of the weld quality is embedded in this signal. The system is able to determine the weld nugget diameter by measuring the delays of the ultrasound signals received during the complete welding cycle. The article presents the system performance on aluminum alloy AA6022.
In July 2021, a commercial-off-the-shelf hydrophone was deployed in a free-drifting configuration to measure underwater acoustic emissions and characterize a 25 kW-rated tidal turbine at the University of New Hampshire's Living Bridge Project in Portsmouth, New Hampshire. Sampling methods and analysis were performed in alignment with the recently published IEC 62600-40 Technical Specification for acoustic characterization of marine energy converters. Results from this study indicate acoustic emissions from the turbine were below ambient sound levels and therefore did not have a significant impact on the underwater noise levels of the project site. As a component of Pacific Northwest National Laboratory's Triton Field Trials (TFiT) described in a paper published in a Special Issue of Journal of Marine Energy Science and Engineering, this study provides a valuable use case for the IEC 62600-40 Technical Specification framework and further recommendations for cost-effective technologies and methods for measuring underwater noise at future current energy converter project sites. The paper can be accessed in the link bellow.
This report documents the development of the Blue Canyon Dome (BCD) testbed, including test site selection, development, instrumentation, and logistical considerations. The BCD testbed was designed for small-scale explosive tests (~5 kg TNT equivalence maximum) for the purpose of comparing diagnostic signals from different types of explosives, the assumption being that different chemical explosives would generate different signatures on geophysical and other monitoring tools. The BCD testbed is located at the Energetic Materials Research and Testing Center near Socorro, New Mexico. Instrumentation includes an electrical resistivity tomography array, geophones, distributed acoustic sensing, gas samplers, distributed temperature sensing, pressure transducers, and high-speed cameras. This SAND report is a reference for BCD testbed development that can be cited in future publications.
Many low-threshold superconducting detectors rely on athermal phonon sensing, in which meV-scale phonons from a DM scatter are sensed via their ability to break Cooper pairs in superconducting films. While detectors based on such pairbreaking sensors are highly advantageous and scalable, their sensor threshold is ultimately limited by the energy needed to break a Cooper pair, 2Δ. We present a novel detector architecture for single phonon detection at the O(10μeV) scale, the qubit-coupled hBAR, that does not share this limitation. This architecture, composed of a superconducting qubit piezoelectrically coupled to a high-overtone bulk acoustic resonator, was originally developed in the context of the quantum acoustics community and has a sensor threshold ultimately limited by thermal noise. Such ultra-low-threshold detectors have a wide range of fundamental science applications, including reactor monitoring via neutrinos.
A molecular Rayleigh scattering technique is developed to measure dynamic gas temperature, velocity, and density in unseeded turbulent flows at sampling rates up to 16 kHz. A high power CW laser beam is focused at a point in an air jet plume and Rayleigh scattered light is collected and spectrally resolved. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. The circular interference fringe pattern is divided into four concentric regions and sampled at 1 and 16 kHz using photon counting electronics. Monitoring the relative change in intensity within each region allows for measurement of gas temperature and velocity. Independently monitoring the total scattered light intensity provides a measure of gas density. A low speed heated jet is used to validate the measurement of temperature fluctuations and an acoustically excited nozzle flow is studied to validate velocity fluctuation measurements. Power spectral density calculations of the property fluctuations, as well as mean and fluctuating quantities are presented. Temperature fluctuation results are compared with constant current anemometry measurements and velocity fluctuation results are compared with constant temperature anemometry measurements at the same locations.
We recorded acoustic, seismic and radio-frequency signatures of 70 solid charge (~2–12 kg) surface explosions (shots) at local distances (0.1–1.5 km) to determine if such signals could be fused for blast monitoring. We observed that each geophysical signature was sufficiently repeatable between similar shots to be identifiable with multichannel correlation detectors. Using template signals from a large explosion, we then processed heavily contaminated data recording a smaller shot with these detectors, and missed or marginally detected the resultant target signals. By then fusing the p-values of these statistics through Fisher's combined probability test, we clearly identified the same explosion signals at thresholds consistent with the false alarm on noise rates of the correlation detectors. This resulting Fisher test thereby provided high-probability detections, zero false alarms and higher theoretical detection capability.
Seismic techniques are the dominant geophysical techniques for the characterization of subsurface structures and stratigraphy. The seismic techniques also dominate the monitoring and mapping of reservoir injection and production processes. Borehole seismology, of all the seismic techniques, despite its current shortcomings, has been shown to provide the highest resolution characterization and most precise monitoring results because it generates higher signal to noise ratio and higher frequency data than surface seismic techniques. The operational environments for borehole seismic instruments are however much more demanding than for surface seismic instruments making both the instruments and the installation much more expensive. The current state-of-the-art borehole seismic instruments have not been robust enough for long term monitoring compounding the problems with expensive instruments and installations. Furthermore, they have also not been able to record the large bandwidth data available in boreholes or having the sensitivity allowing them to record small high frequency micro seismic events with high vector fidelity. To reliably achieve high resolution characterization and long term monitoring of Enhanced Geothermal Systems (EGS) sites a new generation of borehole seismic instruments must therefore be developed and deployed. To address the critical site characterization and monitoring needs for EGS programs, US Department of Energy (DOE) funded Paulsson, Inc. in 2010 to develop a fiber optic based ultra-large bandwidth clamped borehole seismic vector array capable of deploying up to one thousand 3C sensor pods suitable for deployment into ultra-high temperature and high pressure boreholes. Tests of the fiber optic seismic vector sensors developed on the DOE funding have shown that the new borehole seismic sensor technology is capable of generating outstanding high vector fidelity data with extremely large bandwidth: 0.01 – 6,000 Hz. Field tests have shown that the system can record events at magnitudes much smaller than M-2.6 at frequencies up to 2,000 Hz. The sensors have also proved to be about 100 times more sensitive than the regular coil geophones that are used in borehole seismic systems today. The fiber optic seismic sensors have furthermore been qualified to operate at temperatures over 300°C (572°F). Simultaneously with the fiber optic based seismic 3C vector sensors we are using the lead-in fiber to acquire Distributed Acoustic Sensor (DAS) data from the surface to the bottom of the vector array. While the DAS data is of much lower quality than the vector sensor data it provides a 1 m spatial sampling of the downgoing wavefield which will be used to build the high resolution velocity model which is an essential component in high resolution imaging and monitoring.
On-orbit flight anomalies that occurred after several months of operation were attributed to excessive leakage currents in CDR35 style 0.47 microF 50 V capacitors operating at 10 V. In this work, a lot of capacitors similar to the lot that caused the anomaly have been evaluated in parallel with another lot of similar parts to assess their susceptibility to cracking under manual soldering conditions and get insight into a possible mechanism of failure. Leakage currents in capacitors were monitored at different voltages and environmental conditions before and after terminal solder dip testing that was used to simulate thermal shock during manual soldering. Results of cross-sectioning, acoustic microscopy, and measurements of electrical and mechanical characteristics of the parts have been analyzed, and possible mechanisms of failures considered. It is shown that the susceptibility to cracking and failures caused by manual soldering is lot-related. Recommendations for testing that would help to select lots that are more robust against manual soldering stresses and mitigate the risk of failures suggested.
Seismic velocities and elastic moduli of rocks are known to vary significantly with applied stress, which indicates that these materials exhibit nonlinear elasticity. Monochromatic waves in nonlinear elastic media are known to generate higher harmonics and combinational frequencies. Such effects have the potential to be used for broadening the frequency band of seismic sources, characterization of the subsurface, and safety monitoring of civil engineering infrastructure. However, knowledge on nonlinear seismic effects is still scarce, which impedes the development of their practical applications. To explore the potential of nonlinear seismology, we performed three experiments: two in the field and one in the laboratory. The first field experiment used two vibroseis sources generating signals with two different monochromatic frequencies. The second field experiment used a surface orbital vibrator with two eccentric motors working at different frequencies. In both experiments, the generated wavefield was recorded in a borehole using a fiber-optic distributed acoustic sensing cable. Both experiments showed combinational frequencies, harmonics, and other intermodulation products of the fundamental frequencies both on the surface and at depth. Laboratory experiments replicated the setup of the field test with vibroseis sources and showed similar nonlinear combinations of fundamental frequencies. Amplitudes of the nonlinear signals observed in the laboratory showed variation with the saturating fluid. These results confirm that nonlinear components of the wavefield propagate as body waves, are likely to generate within rock formations, and can be potentially used for reservoir fluid characterization.