Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

OptiMX

OptiMX is a GUI-oriented program with principal aim to be an easy to use, yet comprehensive, interactive accelerator optics design and analysis tool. It was originally developed starting in the 1990s as an MS Windows centric application using the commercial Borland OWL framework. In the spring of 2014, a decision was made to port OptiM to Qt, a modern, portable and open framework. As much as possible, the original interface was preserved.While a significant amount of refactoring was required, the underlying physics has been for the most, left unchanged. The custom plots of the original application have been replaced with functional equivalents based on a stable and well-established library (qwt). With very few minor exceptions the new refactored OptiMX should be a drop-in replacement for the original OWL version.

Lebedev, ValeriA. [Joint Inst. for Nuclear Researc↗

THERMAL ANALYSIS OF THE FAIR SIS300 MODEL DIPOLE

Design activities, conductor R and D and model coil construction are under way for the development of a curved superconducting dipole for the fast cycled SIS300 synchrotron at FAIR at GSI. The main target is the construction within 2009 of a half-length model magnet (cold mass fully integrated in a horizontal cryostat). This magnet is designed for a maximum central field of 4.5 T in a bore of 100 mm, with a ramp rate of 1 T/s. The magnetic length of the model is 3.9 m with a curvature radius of 66.67 m (27 mm of sagitta). This paper describes the thermal analysis of the magnet, based on the estimated values of the losses in the cold mass. The study has been performed with 2-D finite element codes, both in steady state and transient analysis. The study has been completed with measurements of overall thermal exchange coefficient between the kapton-insulated cables and the supercritical helium, in order to validate the adopted assumptions about the material thermal properties.

43 PARTICLE ACCELERATORS↗

Niowave Design and Analysis of a 200 kW Converter

LANL is providing support to Niowave Inc. on the design and analysis of a 200 kW converter. The current design of the 200 kW (40 MeV, 5 mA electron beam) converter consists of LBE flowing from the top to the bottom. When compared to the Mk.5 20 kW converter, which flowed LBE from the bottom, flowing over a divider plate to create a waterfall, the 200 kW converter eliminates the divider plate, which would otherwise have melted with the higher beam power. Because the LBE flows from the top to the bottom, alternate methods to the divider plate need to be utilized to ensure a stable flow that minimizes splashing at the bottom of the LBE waterfall, while maintaining a uniform LBE thickness at the beam, and steady LBE flow at the desired flow rate.

43 PARTICLE ACCELERATORS↗

Niowave Ancillary Systems – FY21: In Partial Fulfillment of the Deliverable Requirement for Niowave Ancillary Systems Support by LANL

Niowave Inc. produces medical radioisotopes within the US. Lead-bismuth eutectic (LBE) is irradiated using an electron beam to produce neutrons that are used in the production of Molybdenum-99 (Mo-99). The medical community relies on a steady supply of Mo-99 which is primarily used in medical diagnostic imaging. The irradiation of LBE results in high temperatures within the molten metal, this work focusses on the design of ancillary systems associated with the liquid metal system. The LBE is initially at a temperature of 200°C and flows over a steel plate to create a waterfall. The electron beam is then aimed at the waterfall to generate neutrons. The peak temperatures of the LBE post irradiation depend on the beam energy of the LINAC. For a 15 MeV and 20 kW beam, the temperatures can range between 300°C and 350°C. The LBE is cycled through the system to create a closed loop that requires the post-irradiation LBE to be cooled back to 200°C. This work focuses on the heat exchanger and condenser system responsible for the cooling of the post-irradiation LBE.

36 MATERIALS SCIENCE↗

Accurate Machine Learning for Predicting the Viscosities of Deep Eutectic Solvents

Deep eutectic solvents (DESs) are emerging as environmentally friendly designer solvents for mass transport and heat transfer processes in industrial applications; however, the lack of accurate tools to predict and thus control their viscosities under both a range of environmental factors and formulations hinders their general application. While DESs may serve as designer solvents, with nearly unlimited combinations, this unfortunately makes it experimentally infeasible to comprehensively measure the viscosities of all DESs of potential industrial interest. To assist in the design of DESs, we have developed several new machine learning (ML) models that accurately and rapidly predict the viscosities of a diverse group of DESs at different temperatures and molar ratios using, to date, one of the most comprehensive data sets containing the properties of over 670 DESs over a wide range of temperatures (278.15–385.25 K). Three ML models, including support vector regression (SVR), feed forward neural networks (FFNNs), and categorical boosting (CatBoost), were developed to predict DES viscosity as a function of temperature and molar ratio and contrasted with multilinear and two-factor polynomial regression baselines. Further, quantum chemistry-based, COSMO-RS-derived sigma profile (σ-profile) features were used as inputs for the ML models. The CatBoost model is excellent at externally predicting DES viscosity, as indicated by high R 2 (0.99) and low root-mean-square-error (RMSE) and average absolute relative deviations (AARD) (5.22%) values for the testing data sets, and 98% of the data points lie within the 15% of AARD deviations. Furthermore, SHapley additive explanation (SHAP) analysis was employed to interpret the ML results and rationalize the viscosity predictions. The result is an ML approach that accurately predicts viscosity and will aid in accelerating the design of appropriate DESs for industrial applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Accelerated Stress Tests Based on Fuel Cell Vehicle Data

UTC will led a top-tier team of industry and national laboratory participants to update and improve DOE’s Accelerated Stress Tests (AST’s) for hydrogen fuel cells. This in-depth investigation will focused on critical fuel cell components (e.g. membrane electrode assemblies - MEA) whose durability represented barriers for widespread commercialization of hydrogen fuel cell technology. UTC had access to MEA materials that had accrued significant load time under real-world conditions in PureMotion® 120 power plant used in transit buses. These materials are referred to as end-of-life (EOL) components in the rest of this document. Advanced characterization techniques were used to evaluate degradation mode progress using these critical cell components extracted from both bus power plants and corresponding materials tested using the DOE AST’s. These techniques were applied to samples at beginning-of-life (BOL) to serve as a baseline. These comparisons advised the progress of the various failure modes that these critical components were subjected to, such as membrane degradation, catalyst support corrosion, platinum group metal dissolution, and others. Gaps in the existing ASTs predicted the degradation observed in the field in terms of these modes were outlined. Using the gaps, new AST’s were recommended and tested to better reflect the degradation modes seen in field operation. Also, BOL components were degraded in a test vehicle at UTC designed to accelerate the bus field operation.

08 HYDROGEN↗

A multi-beamlet analysis of the MITICA accelerator

The thermo-mechanical analysis and the mechanical design of the accelerator of MITICA (i.e. the full size prototype of the ITER neutral beam injector under construction at RFX [1]) are based on the calculation of the power deposition induced by particle impacts. This calculation is performed by EAMCC [2], a relativistic particle tracking code based on the Monte-Carlo method for describing collisions inside the accelerator, under prescribed electric and magnetic fields. The magnetic field maps are produced by 3D codes, while the electric field maps come from the 2D axi-symmetric code SLACCAD [3]. In order to perform a multi-beamlet analysis, which allows to take into account the beamlet-beamlet repulsion, and to consider other effects neglected under the hypothesis of axi-symmetric beam, a fully 3D version of the code is required. In this paper, a modified version of EAMCC, fully 3D, capable of modifying the mesh of the 3D maps and of dealing with uneven meshes is presented. A finer mesh is used just in the regions where a more detailed description of the fields is required, for a more realistic simulation. A comparison between the original code and the modified version is presented at first, as a validation of the modifications introduced in the latter. Subsequently, the main results of a single-beamlet analysis performed with the two versions of the code are shown and the differences between the 2D and the 3D simulations discussed. The last part is dedicated to the multi-beamlet simulation of the accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MO-FG-BRC-00: Joint AAPM-ESTRO Symposium: Advances in Experimental Medical Physics

Experimental research in medical physics has expanded the limits of our knowledge and provided novel imaging and therapy technologies for patients around the world. However, experimental efforts are challenging due to constraints in funding, space, time and other forms of institutional support. In this joint ESTRO-AAPM symposium, four exciting experimental projects from four different countries are highlighted. Each project is focused on a different aspect of radiation therapy. From the USA, we will hear about a new linear accelerator concept for more compact and efficient therapy devices. From Canada, we will learn about novel linear accelerator target design and the implications for imaging and therapy. From France, we will discover a mature translational effort to incorporate theranostic nanoparticles in MR-guided radiation therapy. From Germany, we will find out about a novel in-treatment imaging modality for particle therapy. These examples of high impact, experimental medical physics research are representative of the diversity of such efforts that are on-going around the globe. J. Robar, Research is supported through collaboration with Varian Medical Systems and Brainlab AGD. Westerly, This work is supported by the Department of Radiation Oncology at the University of Colorado School of Medicine. COI: NONEK. Parodi, Part of the presented work is supported by the DFG (German Research Foundation) Cluster of Excellence MAP (Munich-Centre for Advanced Photonics) and has been carried out in collaboration with IBA.

60 APPLIED LIFE SCIENCES↗

Toward Guided Mutagenesis: Gaussian Process Regression Predicts MHC Class II Antigen Mutant Binding

Antigen-specific immunotherapies (ASI) require successful loading and presentation of antigen peptides into the major histocompatibility complex (MHC) binding cleft. One route of ASI design is to mutate native antigens for either stronger or weaker binding interaction to MHC. Exploring all possible mutations is costly both experimentally and computationally. To reduce experimental and computational expense, here we investigate the minimal amount of prior data required to accurately predict the relative binding affinity of point mutations for peptide-MHC class II (pMHCII) binding. Using data from different residue subsets, we interpolate pMHCII mutant binding affinities by Gaussian process (GP) regression of residue volume and hydrophobicity. We apply GP regression to an experimental data set from the Immune Epitope Database, and theoretical data sets from NetMHCIIpan and Free Energy Perturbation calculations. We find that GP regression can predict binding affinities of nine neutral residues from a six-residue subset with an average R 2 coefficient of determination value of 0.62 ± 0.04 (±95% CI), average error of 0.09 ± 0.01 kcal/mol (±95% CI), and with an receiver operating characteristic (ROC) AUC value of 0.92 for binary classification of enhanced or diminished binding affinity. Similarly, metrics increase to an R2 value of 0.69 ± 0.04, average error of 0.07 ± 0.01 kcal/mol, and an ROC AUC value of 0.94 for predicting seven neutral residues from an eight-residue subset. Our work finds that prediction is most accurate for neutral residues at anchor residue sites without register shift. This work holds relevance to predicting pMHCII binding and accelerating ASI design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MO-FG-BRC-04: Ionacoustic Imaging for Particle Range Verification

Experimental research in medical physics has expanded the limits of our knowledge and provided novel imaging and therapy technologies for patients around the world. However, experimental efforts are challenging due to constraints in funding, space, time and other forms of institutional support. In this joint ESTRO-AAPM symposium, four exciting experimental projects from four different countries are highlighted. Each project is focused on a different aspect of radiation therapy. From the USA, we will hear about a new linear accelerator concept for more compact and efficient therapy devices. From Canada, we will learn about novel linear accelerator target design and the implications for imaging and therapy. From France, we will discover a mature translational effort to incorporate theranostic nanoparticles in MR-guided radiation therapy. From Germany, we will find out about a novel in-treatment imaging modality for particle therapy. These examples of high impact, experimental medical physics research are representative of the diversity of such efforts that are on-going around the globe. J. Robar, Research is supported through collaboration with Varian Medical Systems and Brainlab AGD. Westerly, This work is supported by the Department of Radiation Oncology at the University of Colorado School of Medicine. COI: NONEK. Parodi, Part of the presented work is supported by the DFG (German Research Foundation) Cluster of Excellence MAP (Munich-Centre for Advanced Photonics) and has been carried out in collaboration with IBA.

60 APPLIED LIFE SCIENCES↗

Production Facility Prototype Blower Installation Report with 1000 Hr Test Results

The roots blower in use at ANL for in-beam experiments and also at LANL for flow tests was sized for 12 mm diameter disks and significantly less beam heating. Currently, the disks are 29 mm in diameter, with a 12 mm FWHM Gaussian beam spot at 42 MeV and 2.86 μA on each side of the target, 5.72 μA total. The target design itself is reported elsewhere. With the increased beam heating, the helium flow requirement increased so that a larger blower was needed for a mass flow rate of 400 g/s at 2.76 MPa (400 psig). An Aerzen GM 12.4 blower was selected, and is currently being installed at the LANL facility for target and component flow testing. This report describes this blower/motor/pressure vessel package and the status of the facility preparations. The blower has been operated for 1000 hours as a preliminary investigation of long-term performance, operation and possible maintenance issues. The blower performed well, with no significant change in blower head or mass flow rate developed under the operating conditions. Upon inspection, some oil had leaked out of the shaft seal of the blower. The shaft seal and bearing race have been replaced.

43 PARTICLE ACCELERATORS↗

MO-FG-BRC-02: Low-Z Switching Linear Accelerator Targets: New Options for Image Guidance and Dose Enhancement in Radiotherapy

Experimental research in medical physics has expanded the limits of our knowledge and provided novel imaging and therapy technologies for patients around the world. However, experimental efforts are challenging due to constraints in funding, space, time and other forms of institutional support. In this joint ESTRO-AAPM symposium, four exciting experimental projects from four different countries are highlighted. Each project is focused on a different aspect of radiation therapy. From the USA, we will hear about a new linear accelerator concept for more compact and efficient therapy devices. From Canada, we will learn about novel linear accelerator target design and the implications for imaging and therapy. From France, we will discover a mature translational effort to incorporate theranostic nanoparticles in MR-guided radiation therapy. From Germany, we will find out about a novel in-treatment imaging modality for particle therapy. These examples of high impact, experimental medical physics research are representative of the diversity of such efforts that are on-going around the globe. J. Robar, Research is supported through collaboration with Varian Medical Systems and Brainlab AGD. Westerly, This work is supported by the Department of Radiation Oncology at the University of Colorado School of Medicine. COI: NONEK. Parodi, Part of the presented work is supported by the DFG (German Research Foundation) Cluster of Excellence MAP (Munich-Centre for Advanced Photonics) and has been carried out in collaboration with IBA.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRC-01: MR-Guided Radiation Therapy with Gadolinium Nanoparticles: From Chalkboard to First Clinical Trials

Experimental research in medical physics has expanded the limits of our knowledge and provided novel imaging and therapy technologies for patients around the world. However, experimental efforts are challenging due to constraints in funding, space, time and other forms of institutional support. In this joint ESTRO-AAPM symposium, four exciting experimental projects from four different countries are highlighted. Each project is focused on a different aspect of radiation therapy. From the USA, we will hear about a new linear accelerator concept for more compact and efficient therapy devices. From Canada, we will learn about novel linear accelerator target design and the implications for imaging and therapy. From France, we will discover a mature translational effort to incorporate theranostic nanoparticles in MR-guided radiation therapy. From Germany, we will find out about a novel in-treatment imaging modality for particle therapy. These examples of high impact, experimental medical physics research are representative of the diversity of such efforts that are on-going around the globe. J. Robar, Research is supported through collaboration with Varian Medical Systems and Brainlab AGD. Westerly, This work is supported by the Department of Radiation Oncology at the University of Colorado School of Medicine. COI: NONEK. Parodi, Part of the presented work is supported by the DFG (German Research Foundation) Cluster of Excellence MAP (Munich-Centre for Advanced Photonics) and has been carried out in collaboration with IBA.

60 APPLIED LIFE SCIENCES↗

Production Facility Prototype Blower Installation Report with 1000 Hour Test Results

The roots blower in use at ANL for in-beam experiments and also at LANL for flow tests was sized for 12 mm diameter disks and significantly less beam heating. Currently, the disks are 29 mm in diameter, with a 12 mm FWHM Gaussian beam spot at 42 MeV and 2.86 μA on each side of the target, 5.72 μA total. The target design itself is reported elsewhere. With the increased beam heating, the helium flow requirement increased so that a larger blower was needed for a mass flow rate of 400 g/s at 2.76 MPa (400 psig). An Aerzen GM 12.4 blower was selected, and is currently being installed at the LANL facility for target and component flow testing. This report describes this blower/motor/pressure vessel package and the status of the facility preparations. The blower has been operated for 1000 hours as a preliminary investigation of long term performance, operation and possible maintenance issues. The blower performed well, with no significant change in blower head or mass flow rate developed under the operating conditions. Upon inspection, some oil had leaked out of the shaft seal of the blower. The shaft seal and bearing race have been replaced. Test results and conclusions are reported.

43 PARTICLE ACCELERATORS↗

LAMP Technical Readiness Evaluation Report (Rev. 1)

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed. Corresponding Technical Readiness Levels (TRLs) were also determined for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. The scope of the evaluation was limited to the project Work Breakdown Structure (WBS) elements as defined for the RFQ Injector and Drift Tube Linac (DTL) systems only. Integration of Instrumentation and Controls (I&C) and Safety Systems was not considered, although specific technologies as related to the RFQ and DTL systems were included. Other elements of the project such as Shielding, System Design, Technical Management, and additional facility integration needed to enable off-line testing and pre-installation commissioning were also not evaluated. Each technical subsystem element was evaluated for technical readiness, however, not all were found to meet the criteria for a CTE. Only two subsystem elements were determined to meet the CTE criteria. Their associated TRLs are summarized in the table below. These subsystem elements of the project have the lowest technical readiness due to either being new, novel or modified, requiring additional R&D before being capable of meeting the project Key Performance Parameters (KPPs) and subsystem requirements, or present technology exists but has not yet been demonstrated in a relevant environment. All other subsystems were determined to have a TRL of 8, indicating that actual operating systems exist having similar performance requirements as needed for LAMP. Details of the technical readiness evaluation for each subsystem is given in the following sections of this report.

43 PARTICLE ACCELERATORS↗

MEBT Chopper System: System Design Document (SDD)

The Medium Energy Beam Transport (MEBT) chopper removes unwanted beam bunches by deflecting them to a target from a bunched beam transported through the MEBT from RFQ to the Drift-Tube Linac (DTL) entrance. The unchopped bunches propagate through the MEBT to DTL, while the deflected bunches are deposited on a target downstream of chopper. The chopper system consists of a deflecting structure, where the beam-deflecting fields are created, and a pulse generator (pulser) that feeds this structure with voltage pulses having the required time pattern. Ideally, the system should turn deflection on and off in the time interval between the bunches to prevent partially chopped / deflected bunches. This usually requires traveling slow-wave chopper structures where the field propagates with the same velocity as the beam, as illustrated in Fig. 1.

43 PARTICLE ACCELERATORS↗

LAMP Technical Readiness Evaluation Report

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed in 2023. This included determining corresponding Technical Readiness Levels (TRLs) for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. This revised report includes a summary of the recent design modifications required to meet the project Key Performance Requirements (KPPs), some of which may reduce technical risk to the project. These recent design modifications include: • Further optimization of the low-energy and medium-energy beam transport regions (LEBT and MEBT, respectively), including relocation of various functional elements (ie choppers, kickers, and bunchers). • An additional H - ion source to separate ion-source function based on beam delivery requirements. • A high-repetition-rate pulsed kicker magnet to select/merge the two H ion beams into a common low-energy beam transport. • Modification and further optimization to a more conventional RFQ design. Performance of the RFQ has been optimized to deliver the required three types of beams while meeting the project KPPs. • The addition of a second chopper in the medium-energy beam transport (MEBT) line to reduce the required pulser voltages. The scope of the evaluation was limited to the project Work Breakdown Structure (WBS) elements as defined for the RFQ Injector and Drift Tube Linac (DTL) systems only. Integration of Instrumentation and Controls (I&C) and Safety Systems was not considered, although specific technologies as related to the RFQ and DTL systems were included. Other elements of the project such as Shielding, System Design, Technical Management, and additional facility integration needed to enable off-line testing and pre-installation commissioning were also not evaluated. Each technical subsystem element was evaluated for technical readiness, however, not all were found to meet the criteria for a CTE. Three subsystem elements were determined to meet the CTE criteria. Their associated TRLs are summarized in the table below. These subsystem elements of the project have the lowest technical readiness due to either being new, novel or modified, requiring additional R&D before being capable of meeting the project Key Performance Parameters (KPPs) and subsystem requirements, or present technology exists but has not yet been demonstrated in a relevant environment. All other subsystems were determined to have a TRL of 8, indicating that actual operating systems exist having similar performance requirements as needed for LAMP. Details of the technical readiness evaluation for each subsystem is given in the following sections of this report.

43 PARTICLE ACCELERATORS↗

Over Voltage in a Multi-sectioned Solenoid during a Quenching

Accurate analysis of over voltage in the superconducting solenoid during a quench is one of the bases for quench protection system design. Classical quench simulation methods can only give rough estimation of the over voltage within a magnet coil. In this paper, for multi-sectioned superconducting solenoid, based on the classical assumption of ellipsoidal normal zone, three-dimension al temperature results are mapped to the one-dimension of the wire, the temperature distribution along the wire and the resistances of each turn are obtained. The coil is treated as circuit comprised of turn resistances, turn self and mutual inductances. The turn resistive voltage, turn inductive voltage, and turn resultant voltage along the wire are calculated. As a result, maximum internal voltages, the layer-to-layer voltages and the turn-to-turn voltages are better estimated. Utilizing this method, the over voltage of a small solenoid and a large solenoid during quenching have been studied. The result shows that this method can well improve the over voltage estimate, especially when the coil is larger.

42 ENGINEERING↗