Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

SU-D-BRC-01: An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy

Purpose: Monte Carlo (MC) simulation is typically regarded as the most accurate dose calculation method for proton therapy. Yet for real clinical cases, the overall accuracy also depends on that of the MC beam model. Commissioning a beam model to faithfully represent a real beam requires finely tuning a set of model parameters, which could be tedious given the large number of pencil beams to commmission. This abstract reports an automatic beam-model commissioning method for pencil-beam scanning proton therapy via an optimization approach. Methods: We modeled a real pencil beam with energy and spatial spread following Gaussian distributions. Mean energy, and energy and spatial spread are model parameters. To commission against a real beam, we first performed MC simulations to calculate dose distributions of a set of ideal (monoenergetic, zero-size) pencil beams. Dose distribution for a real pencil beam is hence linear superposition of doses for those ideal pencil beams with weights in the Gaussian form. We formulated the commissioning task as an optimization problem, such that the calculated central axis depth dose and lateral profiles at several depths match corresponding measurements. An iterative algorithm combining conjugate gradient method and parameter fitting was employed to solve the optimization problem. We validated our method in simulation studies. Results: We calculated dose distributions for three real pencil beams with nominal energies 83, 147 and 199 MeV using realistic beam parameters. These data were regarded as measurements and used for commission. After commissioning, average difference in energy and beam spread between determined values and ground truth were 4.6% and 0.2%. With the commissioned model, we recomputed dose. Mean dose differences from measurements were 0.64%, 0.20% and 0.25%. Conclusion: The developed automatic MC beam-model commissioning method for pencil-beam scanning proton therapy can determine beam model parameters with satisfactory accuracy.

60 APPLIED LIFE SCIENCES↗

The application of the Wigner Distribution to wave type identification in finite length beams

The object of the research described in this paper was to develop a means of identifying the wave-types propagating between two points in a finite length beam. It is known that different structural wave-types possess different dispersion relations: i.e., that their group speeds and the frequency dependence of their group speeds differ. As a result of those distinct dispersion relationships, different wave-types may be associated with characteristic features when structural responses are examined in the time frequency domain. Previously, the time-frequency character of analytically generated structural responses of both single element and multi-element structures were examined by using the Wigner Distribution (WD) along with filtering techniques that were designed to detect the wave-types present in the responses. In the work to be described here, the measure time-frequency response of finite length beam is examined using the WD and filtering procedures. This paper is organized as follows. First the concept of time-frequency analysis of structural responses is explained. The WD is then introduced along with a description of the implementation of a discrete version. The time-frequency filtering techniques are then presented and explained. The results of applying the WD and the filtering techniques to the analysis of a transient response is then presented.

Wahl, T. J.↗

Some interesting aspects of physisorption stay-time measurements obtained using molecular-beam techniques

Stay-time distributions have been obtained for Xe physisorbing on polycrystalline nickel as a function of the target temperature using a pulsed molecular-beam technique. Some interesting effects due to ion bombardment of the surface using He, Ar, and Xe ions are presented. Measured detector signal shapes are found to deviate from those predicted for first-order desorption with velocities corresponding to Maxwellian effusion at the surface temperature. Evidence is found for interaction between beam pulse adsorption and steady-state adsorption of beam species background atoms.

Wilmoth, R. G.↗

On the stability of proton beams against resonant scattering by Alfven waves in solar flare loops

The growth of Alfven waves in magnetized hydrogen plasma at flare-loop densities and magnetic field strengths driven by a dilute population of streaming protons in the energy range 10-1000 keV is investigated. The streaming distribution induces wave growth principally through resonant interactions between forward-moving protons and forward-propagating waves. All other factors constant, the maximum growth rate increases with mean beam energy and with increased narrowness of the beam distribution. The frequency of the most rapidly growing waves is inversely related to the mean beam energy. Under typical flare conditions, thermal damping when mean energy equals the Alfven speed effectively stabilizes proton beams of moderate collimation. At beam energies only one order of magnitude larger, thermal damping under flare loop conditions is insufficient to prevent highly restrictive upper limits on the beam-to-background proton density ratio for even mildly collimated proton beams.

Tamres, David H.↗

The Gaussian Laser Angular Distribution in HYDRA's 3D Laser Ray Trace Package

In this note, the angular distribution of rays launched by the 3D LZR ray trace package is derived for Gaussian beams (npower==2) with bm model=3±. Beams with bm model=+3 have a nearly at distribution, and beams with bm model=-3 have a nearly linear distribution when the spot size is large compared to the wavelength.

42 ENGINEERING↗

SU-F-BRE-03: Consideration of a Track-Interaction Model for Radiochromic Film Response

Purpose: Conventional methods for characterizing the energy response of radiochromic film (RCF) typically involve assessing changes in response when exposed to various beam qualities and use Monte Carlo to determine absorbed dose. These methods represent RCF as a dose integrator of a homogeneous energy deposition volume. Apparent film saturation, nonlinearity, and intrinsic energy dependence are unpredicted with conventional methods. Recent work has shown significant RCF intrinsic energy dependence, which limits its use in absolute dosimetry. This work introduces a track-interaction model (TIM) for RCF and assesses its ability to predict total energy response. Methods: A TIM based on Katz single-hit theory was developed to accumulate energy flux along particle tracks within active crystals, represented as (1×1×20)um{sup 3} prisms about the Gafchromic™ EBT3 active volume using MCNP5 and Matlab. Energy flux contributed to film response only if near the threshold energy for polymerization in polydiacetylenes (2.5eV/monomer). Energy deposition in excess of maximum efficiency represented crystal saturation and did not contribute to film response. The TIM was applied to RCF exposed in air to various monoenergetic photon beams and Co-60. Geometric distribution of energy flux was found for each beam quality in a (1×1)mm{sup 2} RCF area. RCF response relative to Co-60 absorbed dose-to-water (S-TIM) was determined and compared to published values (S-PUB). Results: TIM successfully predicted that lower energy radiation is less effective at inducing polymerization, though the magnitude of the phenomenon was overpredicted. S-TIM was −29% and +20% for 20 and 40 keV, respectively. This agreed qualitatively with S-PUB of −27% and +16%. TIM-generated sensitometric curves contained the non-linearity and saturation apparent in RCF. Conclusion: This work indicates the possibility for TIMs to predict changes in RCF response to various energies. Future work will refine TIM by considering size distributions of active elements, other RCF formulations, and response in complex treatment fields. Acknowledgements: The authors wish to thank Dr. Christopher Soares at NIST (Gaithersburg, MD) for performing film measurements and Dr. David Lewis of Ashland, Inc. (Wayne, NJ) for making the EBT3 film available to us.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanisms of Ionospheric Mass Escape

The dependence of ionospheric O+ escape flux on electromagnetic energy flux and electron precipitation into the ionosphere is derived for a hypothetical ambipolar pick-up process, powered the relative motion of plasmas and neutral upper atmosphere, and by electron precipitation, at heights where the ions are magnetized but influenced by photo-ionization, collisions with gas atoms, ambipolar and centrifugal acceleration. Ion pick-up by the convection electric field produces "ring-beam" or toroidal velocity distributions, as inferred from direct plasma measurements, from observations of the associated waves, and from the spectra of incoherent radar echoes. Ring-beams are unstable to plasma wave growth, resulting in rapid relaxation via transverse velocity diffusion, into transversely accelerated ion populations. Ion escape is substantially facilitated by the ambipolar potential, but is only weakly affected by centrifugal acceleration. If, as cited simulations suggest, ion ring beams relax into non-thermal velocity distributions with characteristic speed equal to the local ion-neutral flow speed, a generalized "Jeans escape" calculation shows that the escape flux of ionospheric O+ increases with Poynting flux and with precipitating electron density in rough agreement with observations.

Moore, T. E.↗

Neutron imaging with the short-pulse laser driven neutron source at the TRIDENT Laser Facility

Emerging approaches to short-pulse laser-driven neutron production offer a possible gateway to compact, low cost, and intense broad spectrum sources for a wide variety of applications. They are based on energetic ions, driven by an intense short-pulse laser, interacting with a converter material to produce neutrons via breakup and nuclear reactions. Recent experiments performed with the high-contrast laser at the Trident laser facility of Los Alamos National Laboratory have demonstrated a laser-driven ion acceleration mechanism operating in the regime of relativistic transparency, featuring a volumetric laser-plasma interaction. This mechanism is distinct from previously studied ones that accelerate ions at the laser-target surface. The Trident experiments produced an intense beam of deuterons with an energy distribution extending above 100 MeV. This deuteron beam, when directed at a beryllium converter, produces a forward-directed neutron beam with ~5x10 9 n/sr, in a single laser shot, primarily due to deuteron breakup. The neutron beam has a pulse duration on the order of a few nanoseconds with an energy distribution extending from a few hundreds of keV to almost 80 MeV. For the experiments on neutron-source spot-size measurements, our gated neutron imager was setup to select neutrons in the energy range of 2.5 to 35 MeV. The spot size of neutron emission at the converter was measured by two different imaging techniques, using a knife-edge and a penumbral aperture, in two different experimental campaigns. The neutron-source spot size is measured ~1 mm for both experiments. The measurements and analysis reported here give a spatial characterization for this type of neutron source for the first time. In addition, the forward modeling performed provides an empirical estimate of the spatial characteristics of the deuteron ion-beam. Finally, these experimental observations, taken together, provide essential yet unique data to benchmark and verify theoretical work into the basic acceleration mechanism, which remains an ongoing challenge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A new angle-resolved proton energy spectrometer

In typical laser-driven proton acceleration experiments Thomson parabola proton spectrometers are used to measure the proton spectra with very small acceptance angle in specific directions. Stacks composed of CR-39 nuclear track detectors, imaging plates, or radiochromic films are used to measure the angular distributions of the proton beams, respectively. In this paper, a new proton spectrometer, which can measure the spectra and angular distributions simultaneously, has been designed. Proton acceleration experiments performed on the Xtreme light III laser system demonstrates that the spectrometer can give angle-resolved spectra with a large acceptance angle. This will be conductive to revealing the acceleration mechanisms, optimization, and applications of laser-driven proton beams.

43 PARTICLE ACCELERATORS↗

TU-FG-BRB-05: A 3 Dimensional Prompt Gamma Imaging System for Range Verification in Proton Radiotherapy

Purpose: To report on the initial developments of a clinical 3-dimensional (3D) prompt gamma (PG) imaging system for proton radiotherapy range verification. Methods: The new imaging system under development consists of a prototype Compton camera to measure PG emission during proton beam irradiation and software to reconstruct, display, and analyze 3D images of the PG emission. For initial test of the system, PGs were measured with a prototype CC during a 200 cGy dose delivery with clinical proton pencil beams (ranging from 100 MeV – 200 MeV) to a water phantom. Measurements were also carried out with the CC placed 15 cm from the phantom for a full range 150 MeV pencil beam and with its range shifted by 2 mm. Reconstructed images of the PG emission were displayed by the clinical PG imaging software and compared to the dose distributions of the proton beams calculated by a commercial treatment planning system. Results: Measurements made with the new PG imaging system showed that a 3D image could be reconstructed from PGs measured during the delivery of 200 cGy of dose, and that shifts in the Bragg peak range of as little as 2 mm could be detected. Conclusion: Initial tests of a new PG imaging system show its potential to provide 3D imaging and range verification for proton radiotherapy. Based on these results, we have begun work to improve the system with the goal that images can be produced from delivery of as little as 20 cGy so that the system could be used for in-vivo proton beam range verification on a daily basis.

60 APPLIED LIFE SCIENCES↗

Two-photon polymerization of a three dimensional structure using beams with orbital angular momentum

The focus of a beam with orbital angular momentum exhibits internal structure instead of an elliptical intensity distribution of a Gaussian beam, and the superposition of Gauss-Laguerre beams realized by two-dimensional phase modulation can generate a complex three-dimensional (3D) focus. By taking advantage of the flexibility of this 3D focus tailoring, we have fabricated a 3D microstructure with high resolution by two-photon polymerization with a single exposure. Furthermore, we have polymerized an array of double-helix structures that demonstrates optical chirality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion energy distribution near a plasma meniscus for multielement focused ion beams

The axial ion energy spread near a plasma meniscus for multielement focused ion beams is investigated experimentally in atomic and molecular gaseous plasmas of krypton, argon, and hydrogen by tailoring the magnetic field in the region. In the case of magnetic end plugging, the ion energy spread reduces by approx50% near the meniscus as compared to the bulk plasma, thereby facilitating beam focusing. A quadrupole filter can be used to control the mean energy of the ions. Comparison with standard Maxwellian and Druyvesteyn distributions with the same mean energy indicates that the ion energy distribution in the meniscus is deficient in the population of low and high energy tail ions, resulting in a Gaussian-like profile with a spread of approx4 and approx5 eV for krypton and argon ions, respectively. By carefully tuning the wave power, plasma collisionality, and the magnetic field in the meniscus, the spread can be made lower than that of liquid metal ion sources, for extracting focused ion beams of other elements with adequate current density, for research and applications in nanosystems

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional particle-in-cell simulation of electron acceleration by Langmuir waves in an inhomogeneous plasma

A possible solution to the unexplained high intensity hard x-ray emission observable during solar flares was investigated via 3D fully relativistic, electromagnetic particle-in-cell simulations with realistic ion to electron mass ratio. A beam of accelerated electrons was injected into a magnetised, Maxwellian, homogeneous, and inhomogeneous background plasma. The electron distribution function was unstable to the beam-plasma instability and was shown to generate Langmuir waves, while relaxing to plateau formation. In order to estimate the role of the background density gradient on an unbound (infinite spatial extent) beam, three different scenarios were investigated: (a) a uniform density background; (b) a weak density gradient, n{sub e,R}/n{sub e,L} = 3; (c) a strong gradient case, n{sub e,R}/n{sub e,L} = 10, where n{sub e,R} and n{sub e,L} denote background electron densities on the left and right edges of the simulation box, respectively. The strong gradient case produced the largest fraction of electrons beyond 15v{sub th}. Furthermore, two cases (uniform and strong gradient background) with spatially localized beam injections were performed aiming to show drifts of the generated Langmuir wave wavenumbers, as suggested in previous studies. For the strong gradient case, the Langmuir wave power is shown to drift to smaller wavenumbers, as found in previous quasi-linear simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-159: Monte Carlo Simulation Studies of Three-Dimensional Dose Distribution for Polymer Gel Dosimeter and Radiochromic Gel Dosimeter in a Proton Beam

Purpose: The purpose of this simulation study is to evaluate the proton detectability of gel dosimeters, and estimate the three-dimensional dose distribution of protons in the radiochromic gel and polymer gel dosimeter compared with the dose distribution in water. Methods: The commercial composition ratios of normoxic polymer gel and LCV micelle radiochromic gel were included in this simulation study. The densities of polymer and radiochromic gel were 1.024 and 1.005 g/cm3, respectively. The 50, 80 and 140 MeV proton beam energies were selected. The dose distributions of protons in the polymer and radiochromic gel were simulated using Monte Carlo radiation transport code (MCNPX 2.7.0, Los Alamos Laboratory). The water equivalent depth profiles and the dose distributions of two gel dosimeters were compared for the water. Results: In case of irradiating 50, 80 and 140 MeV proton beam to water phantom, the reference Bragg-peak depths are represented at 2.22, 5.18 and 13.98 cm, respectively. The difference in the water equivalent depth is represented to about 0.17 and 0.37 cm in the radiochromic gel and polymer gel dosimeter, respectively. The proton absorbed doses in the radiochromic gel dosimeter are calculated to 2.41, 3.92 and 6.90 Gy with increment of incident proton energies. In the polymer gel dosimeter, the absorbed doses are calculated to 2.37, 3.85 and 6.78 Gy with increment of incident proton energies. The relative absorbed dose in radiochromic gel (about 0.47 %) is similar to that of water than the relative absorbed dose of polymer gel (about 2.26 %). In evaluating the proton dose distribution, we found that the dose distribution of both gel dosimeters matched that of water in most cases. Conclusion: As the dosimetry device, the radiochromic gel dosimeter has the potential particle detectability and is feasible to use for quality assurance of proton beam therapy beam.

07 ISOTOPE AND RADIATION SOURCES↗

Harmonic plasma waves excitation and structure evolution of intense ion beams in background plasmas

The long-term dynamic evolutions of intense ion beams in plasmas have been investigated with two-dimensional electromagnetic particle simulations, taking into account the effect of the two-stream instability between beam ions and plasma electrons. Depending on the initial beam radial density profile and velocity distribution, ring structures may be formed in the beam edge regions. At the later stage of beam-plasma interactions, the ion beams are strongly modulated by the two-stream instability and multiple density spikes are formed in the longitudinal direction. The formation of these density spikes is shown to result from the excitation of harmonic plasma waves when the instability gets saturated. Comparisons between the beam cases with initial flat-top and Gaussian radial density profiles are made, and a higher instability growth rate is observed for the flat-top profile case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-Dimensional Dose Addition of External Beam Radiotherapy and Brachytherapy for Oropharyngeal Patients Using Nonrigid Registration

Purpose: To develop and evaluate a method for adding dose distributions of combined external beam radiotherapy (EBRT) and brachytherapy (BT) for oropharyngeal patients. Methods and Materials: Two computed tomography (CT) scans were used for 5 patients: the EBRT CT, used for EBRT planning, and the BT CT, acquired after catheter implantation. For each scan, the salivary glands and the chewing and swallowing muscles were contoured, and a dose distribution was calculated. A nonrigid transformation was obtained by registering the organs' surfaces. Then the BT dose distribution was mapped onto the EBRT dose distribution by applying the transformation obtained. To account for differences in fractionation, the physical doses were converted to equivalent dose in 2 Gy (EQD{sub 2}), and the total dose was found by adding dose voxel by voxel. The robustness of the dose addition was investigated by varying delineations and input parameters of the registration method and by varying the {alpha}/{beta} parameter for EQD{sub 2}. The effect of the perturbations was quantified using dose-volume histograms (DVH) and gamma analyses (distance-to-agreement/dose-difference = 1 mm/1 Gy). Results: The variations in input parameters and delineations caused only small perturbations in the DVH of the added dose distributions. For most organs the gamma index was low, and it was moderately elevated for organs lying in areas with a steep gradient (median gamma index {<=}2.3 for constrictor muscles, {<=}0.7 for all other organs). Conclusions: The presented method allows adding dose distributions of combined EBRT and BT for oropharyngeal patients. In general, the method is reliable and robust with respect to uncertainties in organ delineation, perturbations in input parameters of the method, and {alpha}/{beta} values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-201: Investigation of MRI Guided Proton Therapy

Purpose: Image-guided radiation therapy has been employed for cancer treatment to improve the tumor localization accuracy. Radiation therapy with proton beams requires more on this accuracy because the proton beam has larger uncertainty and dramatic dose variation along the beam direction. Among all the image modalities, magnetic-resonance image (MRI) is the best for soft tissue delineation and real time motion monitoring. In this work, we investigated the behavior of the proton beam in magnetic field with Monte Carlo simulations. Methods: A proton Monte Carlo platform, TOPAS, was used for this investigation. Dose calculations were performed with this platform in a 30cmx30cmx30cm water phantom for both pencil and broad proton beams with different energies (120, 150 and 180MeV) in different magnetic fields (0.5T, 1T and 3T). The isodose distributions, dose profiles in lateral and beam direction were evaluated. The shifts of the Bragg peak in different magnetic fields for different proton energies were compared and the magnetic field effects on the characters of the dose distribution were analyzed. Results: Significant effects of magnetic field have been observed on the proton beam dose distributions, especially for magnetic field of 1T and up. The effects are more significant for higher energy proton beam because higher energy protons travel longer distance in the magnetic field. The Bragg peak shift in the lateral direction is about 38mm for 180MeV and 11mm for 120MeV proton beams in 3T magnetic field. The peak positions are retracted back for 6mm and 2mm, respectively. The effect on the beam penumbra and dose falloff at the distal edge of the Bragg peak is negligible. Conclusion: Though significant magnetic effects on dose distribution have been observed for proton beams, MRI guided proton therapy is feasible because the magnetic effects on dose is predictable and can be considered in patient dose calculation.

60 APPLIED LIFE SCIENCES↗

WE-EF-303-11: Activity Distributions of Positron-Emitting-Isotopes Activated by Modulated Spot-Scanning Particle Beams

Purpose: To present the characteristics of positron-emitting-isotope (PEI) activity distributions on homogeneous and CIRS thorax phantoms irradiated by modulated spot-scanning carbon-ions and protons in Siemens IONTRIS system. Methods and Materials: Cylindrical homogeneous wax was irradiated by carbon-ions and protons of 10cm uniform square field with single-energy-layer ranges of 7cm, 16cm and 29cm. Images of PEI distributions were acquired over a period of 30 minutes at 10 minutes after each irradiation. Optimized uniform biological-equivalent doses of carbon-ions over a 5.0cm spherical target was delivered to CIRS phantom. Doses with range shifts in depths from 1mm to 6mm were also calculated and delivered to evaluate the accuracy of measuring activated PEI distributions. Results: Activated PEI distribution on homogeneous phantoms showed sharper peak near distal edge with flatter distribution toward proximal depth by carbon-ions than by protons. For depths near at Bragg-peak, penetration-depth spreading for energies from 10MeV/u to 60 MeV/u are from 0.4mm to 10.3mm, and 1.2mm to 30.4mm for projectile-fragments by carbon-ions and target-fragments by protons, respectively. For depths proximal to Bragg-peak, target-fragments for both carbon-ions and protons had minimal energy dependence in depth. For complex dose distributions delivered to CIRS thorax phantom, similar PEI peak-like distributions were still observed for carbon-ions. And, the changes at locations and edges of measured PEI peak were correlated within 0.5mm of shifted ranges. Mean activities over 5.0cm spherical target were similar for CISR phantom irradiated by doses with various range shifts. Conclusions: Peak-like PEI distributions by carbon-ions with good correlation to distal edges in both homogeneous and CIRS thorax phantoms present the potential for the in-vivo range verification while additional efforts is needed for protons. Due to flat distributions for depths at 6mm proximal to distal edges, mean activity at target might be used for in-vivo dose verification of target.

60 APPLIED LIFE SCIENCES↗