Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

The Vision for Space Exploration

With last year's budget, NASA released a new Strategic Plan outlining a new approach to space exploration using a 'building block' strategy to explore scientifically valuable destinations across our solar system. At the same time that we released the Strategic Plan, our Nation and the NASA family also suffered the loss of the seven brave astronauts aboard the Space Shuttle Columbia. The report of the Columbia Accident Investigation Board emphasized the need for a clearer direction from which to drive NASA's human exploration agenda. On January 14, 2004, the President articulated a new vision for space exploration. You hold in your hands a new, bolder framework for exploring our solar system that builds upon the policy that was announced by the President after months of careful deliberations within the Administration. This plan does not undertake exploration merely for the sake of adventure, however exciting that may be, but seeks answers to profound scientific and philosophical questions, responds to recent discoveries, will put in place revolutionary technologies and capabilities for the future, and will genuinely inspire our Nation, the world, and the next generation. Our aim is to explore in a sustainable, affordable, and flexible manner. We believe the principles and roadmap set down in this document will stand the test of time. Its details will be subject to revision and expansion as new discoveries are made, new technologies are applied, and new challenges are met and overcome. This plan is guided by the Administration's new space exploration policy, 'A Renewed Spirit of Discovery: The President's Vision for U.S. Space Exploration,' a copy of which is provided on the following pages. NASA is releasing this plan simultaneously with NASA's FY 2005 Budget Justification. This plan is fiscally responsible, consistent with the Administration s goal of cutting the budget deficit in half within the next five years. I cannot overstate how much NASA will change in the coming years as this plan is implemented. I also cannot overstate how profound the rewards will be on this new course. With the support of Congress, the science community, the NASA civil and contractor workforce, and most importantly, the American public, we will embark on this very exciting future. When Christopher Columbus made his voyages across the Atlantic in the 15th and 16th centuries, his ships carried the inscription 'Following the light of the sun, we left the Old World.' I look forward to joining you as we follow the light of the planets and the stars into the new worlds of the 21st century.

Source record↗

Single-Frame Terrain Mapping Software for Robotic Vehicles

This software is a component in an unmanned ground vehicle (UGV) perception system that builds compact, single-frame terrain maps for distribution to other systems, such as a world model or an operator control unit, over a local area network (LAN). Each cell in the map encodes an elevation value, terrain classification, object classification, terrain traversability, terrain roughness, and a confidence value into four bytes of memory. The input to this software component is a range image (from a lidar or stereo vision system), and optionally a terrain classification image and an object classification image, both registered to the range image. The single-frame terrain map generates estimates of the support surface elevation, ground cover elevation, and minimum canopy elevation; generates terrain traversability cost; detects low overhangs and high-density obstacles; and can perform geometry-based terrain classification (ground, ground cover, unknown). A new origin is automatically selected for each single-frame terrain map in global coordinates such that it coincides with the corner of a world map cell. That way, single-frame terrain maps correctly line up with the world map, facilitating the merging of map data into the world map. Instead of using 32 bits to store the floating-point elevation for a map cell, the vehicle elevation is assigned to the map origin elevation and reports the change in elevation (from the origin elevation) in terms of the number of discrete steps. The single-frame terrain map elevation resolution is 2 cm. At that resolution, terrain elevation from 20.5 to 20.5 m (with respect to the vehicle's elevation) is encoded into 11 bits. For each four-byte map cell, bits are assigned to encode elevation, terrain roughness, terrain classification, object classification, terrain traversability cost, and a confidence value. The vehicle s current position and orientation, the map origin, and the map cell resolution are all included in a header for each map. The map is compressed into a vector prior to delivery to another system.

Rankin, Arturo L.↗

Cyber Security for Lighting Systems

Fact sheet discusses cyber threats unique to lighting control systems in buildings and helps facility managers identify the types of lighting control systems that could introduce cybersecurity risks. Download the fact sheet.

Cyber security↗

PV Storm Hardening Costs

While solar arrays often survive severe weather events, systems are occasionally compromised and left unable to provide power. For PV systems to act as resilient power providers, they must remain operational. Building a system that is more likely to survive a storm comes at a cost, though. Previous efforts have identified various system measures and practices that can increase the likelihood of a PV system surviving a severe weather event. But what is the cost premium for a storm hardened PV system? This report provides initial estimates for the up-front cost premiums for various methods of storm hardening PV systems.

14 SOLAR ENERGY↗

Infrastructure-Based Cooperative Perception at a Traffic Intersection: Overview and Challenges: Preprint

Recent advancement in autonomous driving vehicles and V2X communication has attracted increasing attention towards Intelligent Transportation Systems to build a safe and reliable traffic intersection. However, most of the systems are still at the initial stages and require significant progress to become a reality. This paper presents an overview of NREL Infrastructure Perception and Control (IPC) framework which is an open-source track-data fusion engine which takes input from infrastructure-based perception sensors and cooperatively shared messages from Connected Autonomous Vehicles (CAVs) and Connected Vehicle (CVs) and the challenges associated with deploying such cooperative perception framework at a four-way traffic intersection in the city of Colorado Springs, CO, USA. The sensor data is collected by deploying two radars and two LiDAR sensors on the IPC mobile lab and two radars on diagonally opposite traffic poles at the proposed intersection. The sensor output results imply the need for rapid sensor calibration to bring the collective perception to a common coordinate frame, the importance of time synchronization between the sensors in order to capture accurate spatial and temporal alignment of the objects, and the need for a health monitoring system with fail safe closed-loop detection model for real-time deployment.

camera↗

A Living Laboratory for Building-Grid Integration

At PNNL we’re developing a test bed for control of how buildings interact with the grid—an important step toward helping buildings achieve their potential for reducing energy use and improving the management of the nation’s power systems. The test bed works by allowing researchers to conduct experiments on PNNL’s specially-equipped Systems Engineering Building. This unique resource will help the Department of Energy achieve its mission of reducing buildings energy use by 50 percent by 2030.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design, Construction, and Field Validation of a Blown-In Fiberglass Wall System in a Cold, Wet, and Windy Climate

In the Native Village of Tununak, located on Nelson Island in Southwest Alaska,buildings are exposed to wind-driven rain and snow throughout the year. The Cold Climate Housing Research Center (CCHRC) and Knauf Insulation partnered with the community in 2018 to design a residence for a public safety officer. Construction began in fall 2021 and is scheduled to conclude in summer 2022. The house will use integrated trusses with floor, attic, and wall cavities filled with blown-in fiberglass insulation. Hygrothermal models of the building envelope system demonstrate that the high ambient moisture load will wet the outer edges of the insulation annually regardless of the extent and integrity of exterior weather sealing measures; blown-in fiberglass is expected to be more resilient to this wetting than blown-in cellulose. To verify this, researchers will embed temperature, relative humidity, and moisture sensors in the two windward walls of the house to monitor the ability of the blown-in fiberglass insulation to dry out after wetting events that may have occurred during the transport of the insulation to the building site, storage of the insulation on site, construction process, or after installation in the wall. Sensors will remain in place for two years,documenting the wall's performance over time and verifying the design's potential for use in buildings located in climates where the chance for moisture damage is high. Here, we describe the wall system , design criteria, and the results from the hygrothermal modeling. We share details on the monitoring system's components and the planned management and analysis of data. Finally, we explain how the experiences and data from this project will inform future builds in similar locations.

building design↗

New Thermochemical Salt Hydrate System for Energy Storage in Buildings

This paper introduces an innovative design for an “inorganic salt-expanded graphite” composite thermochemical system. The storage unit is made of a perforated, compressed, expanded graphite block impregnated with molten CaCl 2 ∙6H 2 O; the humid air passes through the holes that allow the moisture to diffuse and react with the salt. The prepared block underwent 90 hydration-dehydration cycles. Although most of the performed cycles were carried out with salt overhydration and deliquescence, the treated samples have remained mechanically and thermally stable with no drop in energy density. The volumetric energy density of the composite ranged from 135.5 to 277.6 kWh/m 3 , depending on airflow rate and absolute humidity. To ensure composite material cycling stability, the energy density of the block was measured during hydration at similar conditions of absolute humidity, inlet temperature, and airflow rate (0.01 kg water /kg air , 20 °C, 400 l/min). The average energy density at these conditions was sustained at 219 kWh/m 3 . The block integrity was monitored by visual inspection after removing it from the reactor chamber every few cycles. Both the composite material and its manufacturing process are simple and easy to scale up for future commercialization.

25 ENERGY STORAGE↗

Model calibration of a variable refrigerant flow system with a dedicated outdoor air system: A case study

With increased use of variable refrigerant flow (VRF) systems in the U.S. building sector, interests in capability and rationality of various building energy modeling tools to simulate VRF systems are rising. This paper presents the detailed procedures for model calibration of a VRF system with a dedicated outdoor air system (DOAS) by comparing to detailed measured data from an occupancy emulated small office building. The building energy model is first developed based on as-built drawings, and building and system characteristics available. The whole building energy modeling tool used for the study is U.S. DOE’s EnergyPlus version 8.1. The initial model is, then, calibrated with the hourly measured data from the target building and VRF-DOAS system. In a detailed calibration procedures of the VRF-DOAS, the original EnergyPlus source code is modified to enable the modeling of the specific VRF-DOAS installed in the building. After a proper calibration during cooling and heating seasons, the VRF-DOAS model can reasonably predict the performance of the actual VRF-DOAS system based on the criteria from ASHRAE Guideline 14-2014. The calibration results show that hourly CV-RMSE and NMBE would be 15.7% and 3.8%, respectively, which is deemed to be calibrated. As a result, the whole-building energy usage after calibration of the VRF-DOAS model is 1.9% (78.8 kWh) lower than that of the measurements during comparison period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing Building Energy Efficiency through Advanced Sizing and Dispatch Methods for Energy Storage

Energy storage and electrification of buildings hold great potential for future decarbonization. However, there are several technical and economic barriers that prevent large-scale adoption and integration of energy storage in buildings. These barriers include integration with building control systems, high capital costs, and the necessity to identify and quantify value streams for different stakeholders. To overcome these obstacles, it is crucial to develop advanced sizing and dispatch methods to assist planning and operational decision-making for integrating energy storage in buildings. This work develops simple and flexible optimal sizing and dispatch framework for thermal energy storage (TES) and battery energy storage (BES) systems in large-scale office building. The optimal sizes of TES, BES, as well as other building assets are determined in a joint manner instead of sequentially to avoid sub-optimal solutions. The interaction between the sizing at the planning stage and hourly or sub-hourly dispatch at the operating stage is explicitly modeled. The solution is determined considering both capital costs in optimal sizing and operational benefits in optimal dispatch. Comprehensive assessments are performed using simulation studies to quantify potential energy, economic, and emission benefits by different utility tariffs and climate locations, to improve our understanding of the techno-economic performance of different TES and BES systems, and to identify barriers for adopting energy storage for buildings. Finally, the proposed framework will provide guidance to a broad range of stakeholders to properly design energy storage in buildings and maximizes potential benefits, thereby advancing affordable building energy storage deployment and helping us accelerating the transition towards a cleaner and more equitable energy economy.

Yu, Mingyung↗

Advanced human-machine interface for collaborative building control

A system for collaborative energy management and control in a building, including an energy management controller, one or more occupant HMIs that supports two-way communication between building occupants and a facility manager, and between building occupants and the energy management controller, and a facility manager HMI that supports two-way communication between the facility manager and the building occupants, and between the facility manager and the energy management controller, in which the occupant HMI allows building occupants to provide temperature preferences to the facility manager and the energy management controller, and the facility manager HMI allows the facility manager to configure an energy policy for the building as a set of rules and to view occupants' aggregated temperature preferences, and the energy management controller determines an optimum temperature range that resolves conflicting occupant temperature preferences and occupant temperature preferences that conflict with the facility manager's energy policy for the building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗

Electronic Escape Trails for Firefighters

A proposed wireless-communication and data-processing system would exploit recent advances in radio-frequency identification devices (RFIDs) and software to establish information lifelines between firefighters in a burning building and a fire chief at a control station near but outside the building. The system would enable identification of trails that firefighters and others could follow to escape from the building, including identification of new trails should previously established trails become blocked. The system would include a transceiver unit and a computer at the control station, portable transceiver units carried by the firefighters in the building, and RFID tags that the firefighters would place at multiple locations as they move into and through the building (see figure). Each RFID tag, having a size of the order of a few centimeters, would include at least standard RFID circuitry and possibly sensors for measuring such other relevant environmental parameters as temperature, levels of light and sound, concentration of oxygen, concentrations of hazardous chemicals in smoke, and/or levels of nuclear radiation. The RFID tags would be activated and interrogated by the firefighters and control-station transceivers. Preferably, RFID tags would be configured to communicate with each other and with the firefighters units and the control station in an ordered sequence, with built-in redundancy. In a typical scenario, as firefighters moved through a building, they would scatter many RFID tags into smoke-obscured areas by use of a compressed-air gun. Alternatively or in addition, they would mark escape trails by dropping RFID tags at such points of interest as mantraps, hot spots, and trail waypoints. The RFID tags could be of different types, operating at different frequencies to identify their functions, and possibly responding by emitting audible beeps when activated by signals transmitted by transceiver units carried by nearby firefighters.

Jorgensen, Charles↗

Continuous thermostat setpoint monitoring and correction (Thermostat setpoint correction) v1.0

The Continuous Thermostat Setpoint Monitoring and Correction software is a set of fault detection and correction algorithms that can be implemented in thermostats with two-way OpenAPIs. It is written in the Python language. The algorithms aim to detect the most common and impactful efficiency problems associated with thermostat setpoints - overly aggressive heating or cooling setpoints, incorrect schedules/setbacks, and overly narrow deadbands. These algorithms can automatically detect faults, and implement associated corrective actions to bring the system back to a state of efficient operation. The algorithms can run remotely in the cloud, and directly implemented by connected thermostat manufacturers, or by third party service providers. The software enables a lightweight cost-effective energy management strategy for HVAC systems. The solution is specially viable for small and medium sized commercial buildings, where a full scale building automation system and fault detection and diagnostic tools are often unavailable.

Granderson, Jessica↗

Building America Summer 2012 Technical Update Meeting Report

The Building America Summer 2012 Technical Update Meeting was held on July 24-26, 2012, in Denver, Colorado. More than 300 professionals representing organizations with vested interest in energy efficiency improvements in residential buildings registered for the event. This meeting served to create a forum to discuss issues related to energy efficiency in housing—specifically nine critical challenges without current definitive guidance—and to define recommendations from the BA program for housing industry stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling Exascale Hardware and Software Design through Scalable System Virtualization (Final Report)

The purpose of this project has been to extend the state of the art of systems software for high-end computing (HEC) platforms, and to use systems software to better enable the evaluation of potential future HEC platforms, for example exascale platforms. Such platforms, and their systems software, have the goal of providing scientific computation at new scales, thus enabling new research in the physical sciences and engineering. Over time, the innovations in systems software for such platforms also become applicable to more widely used computing clusters, data centers, and clouds. This was a five-institution project, centered on the Palacios virtual machine monitor (VMM) systems software, a project begun at Northwestern, and originally developed in a previous collaboration between Northwestern University and the University of New Mexico. In this project, Northwestern (including via our subcontract to the University of Pittsburgh) contributed to the continued development of Palacios, along with other team members. We took the leadership role in (1) continued extension of support for emerging Intel and AMD hardware, (2) integration and performance enhancement of overlay networking, (3) connectivity with architectural simulation, (4) binary translation, and (5) support for modern Non-Uniform Memory Access (NUMA) hosts and guests. We also took a supporting role in support for specialized hardware for I/O virtualization, profiling, configurability, and integration with configuration tools. The efforts we led (1-5) were largely successful and executed as expected, with code and papers resulting from them. The project demonstrated the feasibility of a virtualization layer for HEC computing, similar to such layers for cloud or datacenter computing. For effort (3), although a prototype connecting Palacios with the GEM5 architectural simulator was demonstrated, our conclusion was that such a platform was less useful for design space exploration than anticipated due to inherent complexity of the connection between the instruction set architecture level and the microarchitectural level. For effort (4), we found that a code injection approach proved to be more fruitful. The results of our efforts are publicly available in the open source Palacios codebase and published papers, all of which are available from the project web site, v3vee.org. Palacios is currently one of the two codebases (the other being Sandia’s Kitten lightweight kernel) that underlies the node operating system for the DOE Hobbes Project, one of two projects tasked with building a systems software prototype for the national exascale computing effort.

97 MATHEMATICS AND COMPUTING↗