Search NASA⌕ Search

SEARCH · Search NASA

Results for “Buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Assessing the hygrothermal performance of bio-based materials in building wall systems

Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.

Bio-based materials↗

Methodology of CO{sub 2} emission evaluation in the life cycle of office building facades

The construction industry is one of the greatest sources of pollution because of the high level of energy consumption during its life cycle. In addition to using energy while constructing a building, several systems also use power while the building is operating, especially the air-conditioning system. Energy consumption for this system is related, among other issues, to external air temperature and the required internal temperature of the building. The facades are elements which present the highest level of ambient heat transfer from the outside to the inside of tall buildings. Thus, the type of facade has an influence on energy consumption during the building life cycle and, consequently, contributes to buildings' CO{sub 2} emissions, because these emissions are directly connected to energy consumption. Therefore, the aim is to help develop a methodology for evaluating CO{sub 2} emissions generated during the life cycle of office building facades. The results, based on the parameters used in this study, show that facades using structural glazing and uncolored glass emit the most CO{sub 2} throughout their life cycle, followed by brick facades covered with compound aluminum panels or ACM (Aluminum Composite Material), facades using structural glazing and reflective glass and brick facades with plaster coating. On the other hand, the typology of facade that emits less CO{sub 2} is brickwork and mortar because its thermal barrier is better than structural glazing facade and materials used to produce this facade are better than brickwork and ACM. Finally, an uncertainty analysis was conducted to verify the accuracy of the results attained. - Highlights: Black-Right-Pointing-Pointer We develop a methodology for evaluating CO{sub 2} emissions generated during the life cycle of office building facades. Black-Right-Pointing-Pointer This methodology is based in LCA. Black-Right-Pointing-Pointer We use an uncertainty analysis to verify the accuracy of the results attained. Black-Right-Pointing-Pointer We study three typologies of facades. Black-Right-Pointing-Pointer Facades using structural glazing and uncolored glass emit the most CO{sub 2} throughout their life cycle.

54 ENVIRONMENTAL SCIENCES↗

Variability of building environmental assessment tools on evaluating carbon emissions

With an increasing importance of sustainability in construction, more and more clients and designers employ building environmental assessment (BEA) tools to evaluate the environmental friendliness of their building facilities, and one important aspect of evaluation in the BEA models is the assessment of carbon emissions. However, in the absence of any agreed framework for carbon auditing and benchmarking, the results generated by the BEA tools might vary significantly which could lead to confusion or misinterpretation on the carbon performance of a building. This study thus aims to unveil the properties of and the standard imposed by the current BEA models on evaluating the life cycle carbon emissions. The analyses cover the (i) weighting of energy efficiency and emission levels among various environmental performance indicators; (ii) building life cycle stages in which carbon is taken into consideration; (iii) objectiveness of assessment; (iv) baseline set for carbon assessment; (v) mechanism for benchmarking the emission level; and (v) limitations of the carbon assessment approaches. Results indicate that the current BEA schemes focus primarily on operational carbon instead of the emissions generated throughout the entire building life cycle. Besides, the baseline and benchmark for carbon evaluation vary significantly among the BEA tools based on the analytical results of a hypothetical building. The findings point to the needs for a more transparent framework for carbon auditing and benchmarking in BEA modeling. - Highlights: Black-Right-Pointing-Pointer Carbon emission evaluation in building environmental assessment schemes are studied. Black-Right-Pointing-Pointer Simulative carbon emission is modeled for building environmental assessment schemes. Black-Right-Pointing-Pointer Carbon assessments focus primarily on operational stage instead of entire lifecycle. Black-Right-Pointing-Pointer Baseline and benchmark of carbon assessment vary greatly among BEA schemes. Black-Right-Pointing-Pointer A more transparent and comprehensive framework for carbon assessment is required.

54 ENVIRONMENTAL SCIENCES↗

A multi-scale calibration approach for process-oriented aggregated building energy demand models

Long-term energy planning relies largely on projections of future energy demand and hourly load profiles. Aggregate building models are increasingly being utilized to characterize the sensitivity of current and future building stocks to changes in climate, population, and building technology on city-to-regional-to-national scales. Due to challenges in the availability of data, those analyses have been limited to projection of energy demand at a single scale, usually state or country, while long-term planning power system models and production cost models might operate at different spatial scales such as energy regions which are focused on ensuring adequate generation infrastructure. In this work, we propose and evaluate a novel method to calibrate an aggregate building energy demand model (PNNL’s BEND model) against the best available data at the spatial scale of balancing authorities. This approach extends previous work on aggregated building energy demand by facilitating analysis of building energy demand across scales, in particular policy and operational decision-making scales. We show that the bias-corrected model estimates building electric loads reasonably well compared with estimates from a statistical model, but has the additional feature of flexibility across spatial scales. While the calibration approach is presently U.S.-centric and associated with U.S. energy regions, it can be extrapolated to other worldwide regions with similar scale challenges between policy and operational implementation decision making. We discuss the significant challenges involved in formulating and calibrating a complex physical model based on simulations of roughly 100,000 individual buildings against available aggregate regional electric load data and highlight areas for potential future work and improved data collection.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Device-level plug load disaggregation in a zero energy office building and opportunities for energy savings

Along with heating, cooling, ventilation, and lighting, plug loads are one of the principal consumers of energy in commercial buildings. Managing ever-changing plug loads is a great challenge given the quantity and variety of devices in commercial buildings and the cost of monitoring equipment. To address this issue, we propose a method for developing a disaggregated model of an office building's plug loads that utilizes power data from a small portion of monitored devices and a device inventory. Using data from metering and control devices in the Research Support Facility at the National Renewable Energy Laboratory, we compared our model to the building's plug load submeters. We found that the model was effective in predicting the shape of the building's average plug loads; however, it did not account for the entire magnitude of the load. With the disaggregated breakdown, we identified devices that contributed significantly to the building's unoccupied load, such as the audio visual equipment as well as devices that contributed significantly at specific times of the day, such as the microwaves at noon. This disaggregated information enables building owners to make more informed decisions with respect to plug load controls and energy efficiency upgrades. Furthermore, we highlight how the plug loads in the Research Support Facility have changed over time and offer recommendations for implementing this disaggregation method in other buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The good, the bad, and the ugly: Data-driven load profile discord identification in a large building portfolio

Reducing the overall energy consumption and associated greenhouse gas emissions in the building sector is essential for meeting our future sustainability goals. Recently, smart energy metering facilities have been deployed to enable monitoring of energy consumption data with hourly or subhourly temporal resolution. This unprecedented data collection has created various opportunities for advanced data analytics involving load profiles (e.g., building energy benchmarking programs, building-to-grid integration, and calibration of urban-scale energy models). These applications often need preprocessing steps to detect daily load profile discords, such as: 1) outliers due to system malfunctions (the bad) and 2) irregular energy consumption patterns, such as those resulting from holidays (the ugly) compared to normal consumption patterns (the good). However, current preprocessing methods predominantly focus on filtering using statistical threshold values, which fail to capture the contextual discords of daily profiles. In addition, discord detection algorithms in building research are often aimed at finding individual building-level discords, which are not suitable at a large scale. Thus, here, we develop a method for automated load profile discord identification (ALDI) in a large portfolio of buildings (more than 100 buildings). Specifically, ALDI 1) uses the matrix profile (MP) method to quantify the similarities of daily subsequences in time series meter data, 2) compares daily MP values with typical-day MP distributions using the Kolmogorov-Smirnov test, and 3) identifies daily load profile discords in a large building portfolio. We evaluate ALDI using the metering data of both an academic campus and a residential neighborhood. Our results demonstrate that ALDI efficiently discovers measurement errors by system malfunctions and low energy consumption days in the academic campus portfolio, and it detects unique load shape patterns likely driven by occupant behavior and extreme weather conditions in the residential neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental investigation on thermal inertia characterization of commercial buildings for demand response

Characterizing the thermal inertia of commercial buildings is of great importance in quantifying demand flexibility. Experimental tests can be used to investigate the thermal inertia of commercial buildings. However, existing studies tend to be qualitative and have limited scope. In this study, a comprehensive field test has been performed to assess the thermal inertia of commercial buildings. In this field test, six buildings are selected with different sizes, vintages, and types of heating, ventilation, and air conditioning (HVAC) systems to represent the majority of the U.S. commercial building stock. We quantify the thermal inertia with building operation data collected under various thermostat excitation signals. We then studied the relationship between thermal inertia and intrinsic properties, such as floor area, HVAC system, etc., as well as the operation condition indicators such as outdoor air temperature, zone temperature, and occupancy. The testing results indicate that the median values of the normalized charge response time and the normalized discharge response time of the five buildings are 1~5 hr/ °C and -5~-1 hr/ °C, respectively. The results also show that the thermal inertia of commercial buildings may be sensitive to the HVAC system type but not the floor area or location of zones, i.e., core vs. perimeter. Finally, our results suggest that the relationships between the charging/discharging normalized response time and the zone/outdoor temperature may vary among zones and be highly nonlinear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The metal alloys from the XIX century and weathering action in the Mercado do Ver-o-Peso building, northern Brazil: Identification with the usage of laboratory analysis

The fabrication of metallic buildings started in Europe after the Industrial Revolution in the 18th century. Metallic constructions became very popular, and started being imported by several countries, due to the facility of constructing or assembling. Belém, a northern Brazilian city, holds a great number of buildings entirely made of iron, including the Ver-o-Peso, a fish market which structures were imported from England by the end of the 19th century. This building represents a unique type of architecture and it's an important part of the city's heritage. However, research so far did not focus on its construction materials. Ver-o-Peso building's metal alloys haven't been thoroughly studied concerning physical, chemical and mineralogical characterizations. This paper aims to identify the types of metal alloys used in the building, and also corrosion products' result from weathering actions. The methods used to characterize the materials were scanning electron microscopy and X-ray diffraction. Through this research it was possible to identify four types of iron alloys used in the different parts of the building, characterize the paint coats, and determine types of corrosion. The characterization of the materials in the building allows enrolling basis for restoration processes, documenting the types of metal alloy used in architectural heritage from the 19th century, as well as understanding the advances of corrosion. - Highlights: • Ver-o-peso is a heritage building from the 19th century with unidentified alloys. • Alloy and weathering product characterization was done using SEM/EDS and XRD. • Four metal alloy types were described, indicating different types of foundries. • Weathering products showed distinct mineral phases and physical characteristics. • Original paint coats were found among corrosion products.

36 MATERIALS SCIENCE↗

Comparative Study on Code-based Linear Evaluation of an Existing RC Building Damaged during 1998 Adana-Ceyhan Earthquake

Determination of seismic performance of existing buildings has become one of the key concepts in structural analysis topics after recent earthquakes (i.e. Izmit and Duzce Earthquakes in 1999, Kobe Earthquake in 1995 and Northridge Earthquake in 1994). Considering the need for precise assessment tools to determine seismic performance level, most of earthquake hazardous countries try to include performance based assessment in their seismic codes. Recently, Turkish Earthquake Code 2007 (TEC'07), which was put into effect in March 2007, also introduced linear and non-linear assessment procedures to be applied prior to building retrofitting. In this paper, a comparative study is performed on the code-based seismic assessment of RC buildings with linear static methods of analysis, selecting an existing RC building. The basic principles dealing the procedure of seismic performance evaluations for existing RC buildings according to Eurocode 8 and TEC'07 will be outlined and compared. Then the procedure is applied to a real case study building is selected which is exposed to 1998 Adana-Ceyhan Earthquake in Turkey, the seismic action of Ms = 6.3 with a maximum ground acceleration of 0.28 g It is a six-storey RC residential building with a total of 14.65 m height, composed of orthogonal frames, symmetrical in y direction and it does not have any significant structural irregularities. The rectangular shaped planar dimensions are 16.40 mx7.80 m = 127.90 m{sup 2} with five spans in x and two spans in y directions. It was reported that the building had been moderately damaged during the 1998 earthquake and retrofitting process was suggested by the authorities with adding shear-walls to the system. The computations show that the performing methods of analysis with linear approaches using either Eurocode 8 or TEC'07 independently produce similar performance levels of collapse for the critical storey of the structure. The computed base shear value according to Eurocode is much higher than the requirements of the Turkish Earthquake Code while the selected ground conditions represent the same characteristics. The main reason is that the ordinate of the horizontal elastic response spectrum for Eurocode 8 is increased by the soil factor. In TEC'07 force-based linear assessment, the seismic demands at cross-sections are to be checked with residual moment capacities; however, the chord rotations of primary ductile elements must be checked for Eurocode safety verifications. On the other hand, the demand curvatures from linear methods of analysis of Eurocode 8 together with TEC'07 are almost similar.

58 GEOSCIENCES↗

Creating high performance buildings: Lower energy, better comfort

Buildings play a critical role in the challenge of mitigating and adapting to climate change. It is estimated that buildings contribute 39% of the total U.S. greenhouse gas (GHG) emissions [1] primarily due to their operational energy use, and about 80% of this building energy use is for heating, cooling, ventilating, and lighting. An important premise of this paper is about the connection between energy and comfort. They are inseparable when one talks about high performance buildings. Worldwide data suggests that we are significantly overcooling buildings in the summer, resulting in increased energy use and problems with thermal comfort. In contrast, in naturally ventilated buildings without mechanical cooling, people are comfortable in much warmer temperatures due to shifting expectations and preferences as a result of occupants having a greater degree of personal control over their thermal environment; they have also become more accustomed to variable conditions that closely reflect the natural rhythms of outdoor climate patterns. This has resulted in an adaptive comfort zone that offers significant potential for encouraging naturally ventilated buildings to improve both energy use and comfort. Research on other forms for providing individualized control through low-energy personal comfort systems (desktop fans, foot warmed, and heated and cooled chairs) have also demonstrated enormous potential for improving both energy and comfort performance. Studies have demonstrated high levels of comfort with these systems while ambient temperatures ranged from 64–84°F. Energy and indoor environmental quality are inextricably linked, and must both be important goals of a high performance building.

42 ENGINEERING↗

Occupancy schedule development and its effect on OpenStudio prototype college building model

College buildings have unique characteristics compared with school buildings. Therefore, defining the realistic occupancy schedule in a prototype college building has significant research opportunities. In this study, the actual operating schedules of each space type were collected and generated based on the class reservation schedule and compared with the previous reference schedule (primary/secondary school). Here, the schedules were analyzed for their effect on the OpenStudio prototype college building model. The findings highlight that the use of a typical school building schedule in a college building impairs the granularity of information. The analysis shows significant differences between the previous occupancy schedule and the updated occupancy schedule of the college building, leading to a considerable decrease in occupancy density. Furthermore, the effect of these occupancy pattern changes on the prototype building model is examined. The variations were observed in minimum ventilation requirements, the average mechanical ventilation rate, and energy consumption attributed to changes in occupancy density.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Energy Dispatch Controller for Fuel Cell-Integrated Multi-Zone Building

Stationary fuel cells provide potential opportunities for energy savings when integrated with buildings. Through smart dispatch of both electrical power and heat generated by the fuel cells and managing the building loads, the buildings can achieve more efficient operation. In this paper, we develop an optimal energy dispatch controller to operate a fuel cell-integrated building. The controller leverages the inherent thermal storage and the dispatchable fuel cell to reduce its operating cost and to allow the building to participate in grid services. The proposed controller is implemented on two types of commercial buildings, a large office building and a large hotel, and the effectiveness of the controller is demonstrated through simulations. The results also indicate that the potential saving varies significantly with different system parameters, including season, fuel prices, and equipment sizing, which provide helpful insights for building operators and other stake holders.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Performance-based earthquake early warning for tall buildings

The ShakeAlert Earthquake Early Warning (EEW) system aims to issue an advance warning to residents on the West Coast of the United States seconds before the ground shaking arrives, if the expected ground shaking exceeds a certain threshold. However, residents in tall buildings may experience much greater motion due to the dynamic response of the buildings. Therefore, there is an ongoing effort to extend ShakeAlert to include the contribution of building response to provide a more accurate estimation of the expected shaking intensity for tall buildings. Currently, the supposedly ideal solution of analyzing detailed finite element models of buildings under predicted ground-motion time histories is not theoretically or practically feasible. The authors have recently investigated existing simple methods to estimate peak floor acceleration (PFA) and determined these simple formulas are not practically suitable. Instead, this article explores another approach by extending the Pacific Earthquake Engineering Research Center (PEER) performance-based earthquake engineering (PBEE) to EEW, considering that every component involved in building response prediction is uncertain in the EEW scenario. Additionally, while this idea is not new and has been proposed by other researchers, it has two shortcomings: (1) the simple beam model used for response prediction is prone to modeling uncertainty, which has not been quantified, and (2) the ground motions used for probabilistic demand models are not suitable for EEW applications. In this article, we address these two issues by incorporating modeling errors into the parameters of the beam model and using a new set of ground motions, respectively. We demonstrate how this approach could practically work using data from a 52-story building in downtown Los Angeles. Using the criteria and thresholds employed by previous researchers, we show that if peak ground acceleration (PGA) is accurately estimated, this approach can predict the expected level of human comfort in tall buildings.

58 GEOSCIENCES↗

Enforcing Building Energy Codes in China: Progress and Comparative Lessons

From 1995 to 2005, building energy use in China increased more rapidly than the world average. China has been adding 0.4 to 1.6 billion square meters of floor space annually , making it the world’s largest market for new construction. In fact, by 2020, China is expected to comprise half of all new construction. In response to this, China has begun to make important steps towards achieving building energy efficiency, including the implementation of building energy standards that requires new buildings to be 65% more efficient than buildings from the early 1980s. Making progress on reducing building energy use requires both a comprehensive code and a robust enforcement system. The latter – the enforcement system – is a particularly critical component for assuring that a building code has an effect. China has dramatically enhanced its enforcement system in the past two years, with more detailed requirements for ensuring enforcement and new penalties for non-compliance. We believe that the U.S. and other developed countries could benefit from learning about the multiple checks and the documentation required in China. Similarly, some of the more user-friendly enforcement approaches developed in the U.S. and elsewhere may be useful for China as it strives to improve enforcement in rural and smaller communities. In this article, we provide context to China’s building codes enforcement system by comparing it to the U.S. Among some of the enforcement mechanisms we look at are testing and rating procedures, compliance software, and training and public information.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Dashboards to Improve Energy and Comfort in Federal Buildings

Federal agencies are taking many steps to improve the sustainability of their operations, including improving the energy efficiency of their buildings, promoting recycling and reuse of materials, encouraging carpooling and alternative transit schemes, and installing low flow water fixture units are just a few of the common examples. However, an often overlooked means of energy savings is to provide feedback to building users about their energy use through information dashboards connected to a building?s energy information system. An Energy Information System (EIS), broadly defined, is a package of performance monitoring software, data acquisition hardware, and communication systems that is used to collect, store, analyze, and display energy information. At a minimum, the EIS provides the whole-building energy-use information (Granderson 2009a). We define a ?dashboard? as a display and visualization tool that utilizes the EIS data and technology to provide critical information to users. This information can lead to actions resulting in energy savings, comfort improvements, efficient operations, and more. The tools to report analyzed information have existed in the information technology as business intelligence (Few 2006). The dashboard is distinguished from the EIS as a whole, which includes additional hardware and software components to collect and storage data, and analysis for resources and energy management (Granderson 2009b). EIS can be used for a variety of uses, including benchmarking, base-lining, anomaly detection, off-hours energy use evaluation, load shape optimization, energy rate analysis, retrofit and retro-commissioning savings (Granderson 2009a). The use of these EIS features depends on the specific users. For example, federal and other building managers may use anomaly detection to identify energy waste in a specific building, or to benchmark energy use in similar buildings to identify energy saving potential and reduce operational cost. There are several vendors of EIS technology that provide information on energy and other environmental variables in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance Buildings – Value, Messaging, Financial and Policy Mechanisms

At the request of the Pacific Northwest National Laboratory, an in-depth analysis of the rapidly evolving state of real estate investments, high-performance building technology, and interest in efficiency was conducted by HaydenTanner, LLC, for the U.S. Department of Energy (DOE) Building Technologies Program. The analysis objectives were • to evaluate the link between high-performance buildings and their market value • to identify core messaging to motivate owners, investors, financiers, and others in the real estate sector to appropriately value and deploy high-performance strategies and technologies across new and existing buildings • to summarize financial mechanisms that facilitate increased investment in these buildings. To meet these objectives, work consisted of a literature review of relevant writings, examination of existing and emergent financial and policy mechanisms, interviews with industry stakeholders, and an evaluation of the value implications through financial modeling. This report documents the analysis methodology and findings, conclusion and recommendations. Its intent is to support and inform the DOE Building Technologies Program on policy and program planning for the financing of high-performance new buildings and building retrofit projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance - United States Pacific Command (PACOM) Guam, Task 3.3: Building Retuning Training

Document describes an onsite workshop and building retuning training conducted in Guam in August 2010. Document reports on issues identified during an audit of several buildings and recommendations to save energy throughout the site. During the workshop, it became apparent that as site personnel maintain the facilities at Guam, the following retuning efforts and strategies should be prioritized: (1) Controlling the mechanical systems operational hours and zone temperature set points appeared to present the best opportunities for savings; (2) Zone temperature set points in some buildings are excessively low, especially at night, when the zone temperatures are so cold that they approached the dewpoint; and (3) Manually-set outside air dampers are providing excessive outside air, especially for spaces that are unoccupied. Two of the larger schools, one on the Naval Base and one on Anderson AFB, are in need of a significant recommissioning effort. These facilities are relatively new, with direct digital controls (DDC) but are significantly out of balance. The pressure in one school is extremely negative, which is pulling humid air through the facility each time a door is opened. The draft can be felt several feet down the halls. The pressure in the other school is extremely positive relative to the outside, and you can stand 20-feet outside and still feel cool drafts of air exiting the building. It is recommended that humidity sensors be installed in all new projects and retrofitted into exist facilities. In this humid climate, control of humidity is very important. There are significant periods of time when the mechanical systems in many buildings can be unloaded and dehumidification is not required. The use of CO{sub 2} sensors should also be considered in representative areas. CO{sub 2} sensors determine whether spaces are occupied so that fresh air is only brought into the space when needed. By reducing the amount of outside air brought into the space, the humidity load is also substantially reduced. CO{sub 2} and humidity sensors, combined with outside air sensors, can be used to predict whether conditions are amenable to mold growth and to automatically adjust systems to help prevent mold without using extra energy. The goal of this training is to give the building operators the knowledge needed to make positive changes in the operation of building systems. As class participants apply this knowledge, building systems will run more efficiently, occupant comfort should improve, while saving energy and reducing greenhouse gas emissions.

54 ENVIRONMENTAL SCIENCES↗

Life-Cycle Evaluation of Concrete Building Construction as a Strategy for Sustainable Cities

Structural materials in commercial buildings in the United States account for a significant fraction of national energy use, resource consumption, and greenhouse gas (GHG) emissions. Robust decisions for balancing and minimizing these various environmental effects require that structural materials selections follow a life-cycle, systems modeling approach. This report provides a concise overview of the development and use of a new life-cycle assessment (LCA) model for structural materials in U.S. commercial buildings-the Berkeley Lab Building Materials Pathways (B-PATH) model. B-PATH aims to enhance environmental decision-making in the commercial building LCA, design, and planning communities through the following key features: (1) Modeling of discrete technology options in the production, transportation, construction, and end of life processes associated U.S. structural building materials; (2) Modeling of energy supply options for electricity provision and directly combusted fuels across the building life cycle; (3) Comprehensiveness of relevant building mass and energy flows and environmental indicators; (4) Ability to estimate modeling uncertainties through easy creation of different life-cycle technology and energy supply pathways for structural materials; and (5) Encapsulation of the above features in a transparent public use model. The report summarizes literature review findings, methods development, model use, and recommendations for future work in the area of LCA for commercial buildings.

25 ENERGY STORAGE↗