Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALENDARS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Site Environmental Report for 2020, Sandia National Laboratories, California

Sandia National Laboratories, California (SNL/CA) is a Department of Energy (DOE) facility. The management and operations of the facility are under a contract with the DOE's National Nuclear Security Administration (NNSA). On May 1, 2017, the name of the management and operating contractor changed from Sandia Corporation to National Technology & Engineering Solutions of Sandia, LLC (NTESS). The DOE, NNSA, Sandia Field Office administers the contract and oversees contractor operations at the site. DOE and its management and operating contractor for Sandia are committed to safeguarding environmental protection, compliance, and sustainability and to ensuring the validity and accuracy of the monitoring data presented in this Annual Site Environmental Report. This Site Environmental Report for 2020 was prepared in accordance with DOE Order 231.1B, Environment, Safety and Health Reporting (DOE 2012). The report provides a summary of environmental monitoring information and compliance activities that occurred at SNL/CA during calendar year 2020, unless noted otherwise. General site and environmental program information is also included.

54 ENVIRONMENTAL SCIENCES↗

Electric Vehicle Charging Infrastructure Trends from the Alternative Fueling Station Locator: First Quarter 2021

The U.S. Department of Energy’s (DOE’s) Alternative Fueling Station Locator contains information on public and private non-residential alternative fueling stations in the United States and Canada and currently tracks ethanol (E85), biodiesel, compressed natural gas, electric vehicle (EV) charging, hydrogen, liquefied natural gas, and propane stations. Of these fuels, EV charging continues to experience rapidly changing technology and growing infrastructure. This report provides a snapshot of the state of EV charging infrastructure in the United States in the first calendar quarter of 2021 (Q1). Using data from the Station Locator, this report breaks down the growth of public and private charging infrastructure by charging level, network, and location. Additionally, this report measures the current state of charging infrastructure compared with the target infrastructure volume for 2030. This information is intended to help transportation planners, policymakers, researchers, infrastructure developers, and others understand the rapidly changing landscape for EV charging. This is the fifth report in a series. Previous reports from 2020 can be found in the Alternative Fuels Data Center (AFDC) and National Renewable Energy Laboratory (NREL) publication databases, as well as the AFDC Charging Infrastructure Trends page (https://afdc.energy.gov/fuels/electricity_infrastructure_trends.html).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2020 Annual Site Environmental Report for Sandia National Laboratories, New Mexico

Sandia National Laboratories, hereinafter referred to as Sandia, is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration. This Annual Site Environmental Report was prepared in accordance with and as required by DOE O 231.1B, Admin Change 1, Environment, Safety and Health Reporting , and is approved for public release. The U.S. Department of Energy (DOE) and its management and operating contractor for Sandia are committed to safeguarding the environment, continually assessing sustainability practices, and ensuring the validity and accuracy of the monitoring data presented here. This report summarizes the environmental protection, restoration, and monitoring programs in place for Sandia National Laboratories, New Mexico (SNL/NM), during calendar year 2020.

54 ENVIRONMENTAL SCIENCES↗

2020 Annual Site Environmental Report for Sandia National Laboratories, Tonopah Test Range, Nevada, and Kaua'i Test Facility, Hawai'i

Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration. The National Nuclear Security Administration’s Sandia Field Office administers the contract and oversees contractor operations at Sandia National Laboratories, Tonopah Test Range (SNL/TTR) in Nevada and Sandia National Laboratories, Kaua‘i Test Facility (SNL/KTF) in Hawai‘i. Activities at SNL/TTR are conducted in support of U.S. Department of Energy weapons programs and have operated at the site since 1957. SNL/KTF has operated as a rocket preparation launching and tracking facility since 1962. The U.S. Department of Energy and its management and operating contractor are committed to safeguarding the environment, assessing sustainability practices, and ensuring the validity and accuracy of the monitoring data presented in this Annual Site Environmental Report. This report summarizes the environmental protection, restoration, and monitoring programs in place at SNL/TTR and SNL/KTF during calendar year 2020. Environmental topics include air quality, ecology, environmental restoration, oil storage, site sustainability, terrestrial surveillance, waste management, water quality, and implementation of the National Environmental Policy Act. This report is prepared in accordance with and as required by DOE O 231.1B, Admin Change 1, Environment, Safety and Health Reporting , and has been approved for public distribution.

54 ENVIRONMENTAL SCIENCES↗

Tank 50 Salt Solution Sample (2QCY21)

In this Technical Report, the chemical and radionuclide contaminant results from the Second Quarter Calendar Year 2021 (CY21) sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) Limits and Targets that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the Second Quarter CY21 sampling of Tank 50 were requested by SRR personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the SRR request, will be obtained semi-annually for the 1QCY21 and 3QCY21 Tank 50 samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Material Compatibility of Elastomers Used in the Salt Waste Processing Facility(SWPF)

Near the beginning of calendar year 2021, Salt Waste Processing Facility (SWPF) processed nearly a million gallons of initially diluted, and subsequently undiluted, supernatant. Higher than usual levels of Isopar L were detected in the Decontaminated Salt Solution (DSS). After shutting down the process and inspecting the DSS coalescers, personnel discovered the coalescers media appeared deformed and at least one had extruded out of the sealing surfaces. The gasket material was removed and sent to the Savannah River National Laboratory to possibly determine the cause of gasket degradation. A memorandum was issued documenting the results that could not rule out assembly error of the coalescer. For example, over torquing the gaskets beyond their recommended degree of compression, may have been a potential failure mode. SRNL recommended performing a quick compatibility test between the different process solutions used at SWPF and four different polymeric materials (the fifth one-Kalrez ® -arrived at the end of this test).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determining Unabated Airborne Radionuclide Emissions Monitoring Requirements Using Inventory-Based Methods

Compliance with the airborne radionuclide emission monitoring requirements in the National Emission Standards for Hazardous Air Pollutants (NESHAP; 40 CFR Part 61, Subpart H) and State requirements in Washington Administrative Code 246–247 and 173-480 were evaluated for Pacific Northwest National Laboratory (PNNL) operations. Additional guidance may be found in the U.S. Department of Energy Handbook, Environmental Radiological Effluent Monitoring and Environmental Surveillance. To meet regulatory requirements, reviews of planned or proposed projects and activities provide the basis for implementing necessary monitoring adjustments or for implementing changes to projects and activities in a timely manner. Potential unabated off-site doses were evaluated for emission locations managed by PNNL and licensed to the Department of Energy. These locations were at facilities in Richland, Washington (i.e., the Hanford Site and PNNL-Richland Campus) and in Sequim, Washington, (PNNL-Sequim Campus, which formerly was known as the Marine Sciences Laboratory). This report describes the inventory-based methods and provides the results for the NESHAP assessment performed in January 2021 for calendar year ending 2020.

40 CFR 61 Subpart H↗

3D Printed, Low Tortuosity Garnet Framework For Beyond 500 Wh/kg Batteries

In this project, we developed LLZO garnet ink recipes and processes for 3D-printing highly ordered ionically conductive garnet porous structures on dense garnet separators. Using this technique, we are able to fabricate controlled architecture LLZO garnet solid-state electrolyte (SSE) trilayers for application in solid-state lithium batteries. The trilayer comprises a thin dense center layer sandwiched between a 3D-printed patterned porous layer and a random porous layer. The dense layer functions as the ionic separator between the anode and cathode. The random porous layer hosts the lithium-metal anode and provides the structural support. The 3D-printed SSE patterned porous layer hosts the cathode, providing continuous, low tortuosity pathways for fast 3D Li+ transport through the cell while increasing the electrode/electrolyte interface area to decrease the interfacial resistance. Compared to the random porous structure, this ordered patterned structure possesses more vacant space for higher cathode loading without sacrificing ionically conducting capability, thus potentially greatly increasing the cell energy density. For demonstration purposes, we developed two patterns for the 3D-printed porous layer: grids and columns, for hosting sulfur and NMC cathode, respectively. The corresponding two types of cells were fabricated and tested, and have demonstrated achievement of theoretical discharge capacity without cathode calendaring. In addition, we developed a fundamental solid-state ionic and electronic transport model to optimize the 3D-printed structures for maximum energy and power density. The model was validated by experiment and provides the critical design criteria for achieving the >500 Wh/kg energy goal as function of C-rate.

25 ENERGY STORAGE↗

Analysis of Microbial Communities as Indicators of Microbially Induced Corrosion Potential in Stainless Steel Piping

The 200 West Area Pump-and-Treat (200W P&T) facility is part of the final remedy decision for the 200 ZP-1 Operable Unit (OU) and is the interim remedial action for 200-UP-1 OU at the Hanford Site. The facility also treats water from other sources across the site, including 200-DV-1 OU perched water, groundwater from the 200-BP-5 OU, and leachate from the Environmental Restoration Disposal Facility. The facility originally operated a biological treatment process for nitrate that resulted in systemic biofouling and loss of injection well capacity, requiring frequent and costly well rehabilitation. Biofouling has also contributed to corrosion of welds and pitting of stainless-steel piping at the facility. The biological treatment for nitrate was suspended at the end of 2019 calendar year to eliminate negative impacts from biological treatments which improve facility operations and treatment of carbon tetrachloride. Evaluation of the 200W P&T facility’s response to operational improvements, specifically the suspension of the biological treatment, provides information on the potential for continued microbially induced corrosion (MIC). To this end, historical data sets (2015-2017) were compared with molecular biological analyses of 200W P&T water samples from 2018-2020 to quantify trends in total microbial biomass and specific microbial indicator species (iron, sulfate, nitrate, and manganese reducing bacteria) known to cause and enhance metal corrosion. Results showed unequivocal reductions (in excess of 90%) in all microbiological indicators measured following the suspension of the biological treatment. Although abundance measurements for all corrosive MIC populations initially declined after removal of the treatment system, nitrate-reducing bacteria (nirK) and sulfate-reducing bacteria remain highly abundant in the system, an order of magnitude higher than the number of cells present prior to the removal of the biological treatment system [5.14e (1.4) cells/L, vs. 1.14e (0.07) cells/L, reported as average (±SD) for n=3]. In addition, there was an unexpected inflection point in 2019 where all microbial indicators increased unexpectedly in abundance in 2020 by as much as two orders of magnitude compared to 2019 samples. Given the limited number of water samples available for this analysis, the cause of the increase in microbial indicators post-biological treatment has not yet been determined. Systematic sampling of the facility for continued monitoring is recommended so that the responses of MIC populations can be evaluated to ensure that further corrosion is avoided, allowing the 200W P&T facility to operate safely and efficiently at design capacity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ganged-PV System Evaluation

The following report contains data and data summaries collected for the SkySun LLC elevated Ganged PV arrays. These arrays were fabricated as a series of PV panels in various orientations, suspended by cables, at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL). Starting in February of 2021, Sandia personnel have collected power and accelerometer data for these arrays to assess design and operational efficacy of varying ganged- PV configurations. The purpose of this power data collection was to see how the various array orientations compare in power collection capability depending on the time of day, year, and the specific daily solar direct normal irradiance (DNI). The power data was collected as a measurement of the power output from the various series strings. The project team measured direct current (DC) voltage and current from the respective arrays. The accelerometer data was collected with the purpose of demonstrating potential destructive mode shapes that could take place with each of the arrays when exposed to high winds. This allowed the team to evaluate whether impacts with respect to specific array orientations using suspended cables is a safe design. All data collection was performed during calendar year 2021.

14 SOLAR ENERGY↗

Precision Electroweak and QCD Studies with Polarized Electrons (Final Technical Report)

In this final technical report, we report on the main products from the scope of the work of the award, in particular the Ph.D. dissertations that summarize the work done by the three graduate students who completed their requirements and defenses during calendar 2021, after completing data analyses on the PREX-II and CREX experiments which made precision measurements of neutron RMS radii of 208 Pb and 48 Ca nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electric Vehicle Charging Infrastructure Trends from the Alternative Fueling Station Locator: Second Quarter 2021

The U.S. Department of Energy's (DOE's) Alternative Fueling Station Locator contains information on public and private non-residential alternative fueling stations in the United States and Canada and currently tracks ethanol (E85), biodiesel, compressed natural gas, electric vehicle (EV) charging, hydrogen, liquefied natural gas, and propane stations. Of these fuels, EV charging continues to experience rapidly changing technology and growing infrastructure. This report provides a snapshot of the state of EV charging infrastructure in the United States in the second calendar quarter of 2021 (Q2). Using data from the Station Locator, this report breaks down the growth of public and private charging infrastructure by charging level, network, and location. Additionally, this report measures the current state of charging infrastructure compared with the target infrastructure volume for 2030. This information is intended to help transportation planners, policymakers, researchers, infrastructure developers, and others understand the rapidly changing landscape for EV charging. This is the sixth report in a series. Reports from previous quarters can be found in the Alternative Fuels Data Center (AFDC) and National Renewable Energy Laboratory (NREL) publication databases, as well as the AFDC Charging Infrastructure Trends page (https://afdc.energy.gov/fuels/electricity_infrastructure_trends.html).

33 ADVANCED PROPULSION SYSTEMS↗

Universal Utility Data Exchange (UUDEX) - Workflow Design - Rev 1

This workflow design document describes the process of establishing a Universal Utility Data Exchange (UUDEX) Connection between two or more UUDEX Endpoints. The existing processes required to establish a data link using Inter Control Center Communications Protocol (ICCP) are very time consuming, from both the perspectives of effort and calendar time. The intent of UUDEX is to provide a more streamlined alternative. The UUDEX Workflow is also used to establish UUDEX Connections to exchange data other than that found in traditional ICCP data exchanges such as exchanges of power system model files, security events and mitigations, disturbance reports, and market data.

97 MATHEMATICS AND COMPUTING↗

Automation of Plot Generation for Strategic Petroleum Reserve Cavern Leaching Monitoring

Monitoring cavern leaching after each calendar year of oil sales is necessary to support cavern stability efforts and long-term availability for oil drawdowns in the U.S. Strategic Petroleum Reserve. Modeling results from the SANSMIC code and recent sonars are compared to show projected changes in the cavern’s geometry due to leaching from raw-water injections. This report aims to give background on the importance of monitoring cavern leaching and provide a detailed explanation of the process used to create the leaching plots used to monitor cavern leaching. In the past, generating leaching plots for each cavern in a given leaching year was done manually, and every cavern had to be processed individually. A Python script, compatible with Earth Volumetric Studio, was created to automate most of the process. The script makes a total of 26 plots per cavern to show leaching history, axisymmetric representation of leaching, and SANSMIC modeling of future leaching. The current run time for the script is one hour, replacing 40-50 hours of the monitoring cavern leaching process.

02 PETROLEUM↗

Meteorological Services Annual Data Report for 2021

This document presents the meteorological data collected at Brookhaven National Laboratory (BNL) by Meteorological Services (Met Services) for the calendar year 2021. The purpose is to publicize the data sets available to emergency personnel, researchers and facility operations. Met services has been collecting data at BNL since 1949. Data from 1994 to the present is available in digital format. Data is presented in monthly plots of one-minute data. This allows the reader the ability to peruse the data for trends or anomalies that may be of interest to them. Full data sets are available to BNL personnel and to a limited degree outside researchers. The full data sets allow plotting the data on expanded time scales to obtain greater details (e.g., daily solar variability, inversions, etc.).

54 ENVIRONMENTAL SCIENCES↗

Freight Analysis Framework Version 5 (FAF5) Base Year 2017 Data Development Technical Report

The Freight Analysis Framework (FAF) integrates data from a variety of sources to create a comprehensive national picture of freight movements among states and major metropolitan areas by all modes of transportation. The latest of this data series is FAF5, which is the fifth generation FAF and is benchmarked on Commodity Flow Survey (CFS) 2017. Except for FAF1 that provided estimates for truck, rail, and water tonnage for calendar year 1998, later generations of FAF (FAF2 through FAF5) were built based on their benchmark year CFS data, for 2002, 2007, 2012, and 2017 respectively. The FAF is produced under a partnership between Bureau of Transportation Statistics (BTS) and Federal Highway Administration (FHWA). As a major data product of the FAF program, the FAF regional database provides a national picture of freight flows to, from, and within the United States (among regions and states), by commodity and mode for the base year, as well as for forecasts up to 30 years into the future in a 5-year interval. Additional FAF data products also include FAF network flows database, where truck movements are routed onto the national highway network, estimates of annual projections, and synchronized historical data series. This report is a technical document prepared to describe the data sources and methodologies applied in the process of building the FAF5 base-year 2017 regional database, released as FAF5.0 in February 2021. This report offers a description of the diverse data sources and modeling methods used in constructing the base year FAF5 regional database. The FAF5 base-year database is used as the base for development of forecasts and for assignment of truck flows on highway network. Similarly, the FAF5 base-year database will be used as the base to generate FAF5 annual estimates. In addition to this report, users are encouraged to refer to the FAF5 User’s Guide, which provides basic information of the data, including definitions of the data attributes, information on how to access the data and tool, as well as detailed data dictionary and code tables.

42 ENGINEERING↗

Surface 3D Electrical Resistivity Tomography Inversion of 2005 BC Cribs and Trenches Datasets

Hydrogeophysics, Inc. (HGI) conducted an electrical resistivity tomography (ERT) dataset at the BC Cribs and Trenches site, located in the Central Plateau of the Hanford Site. The 20 trenches and 6 cribs received large volumes of liquid inorganic waste in the 1950s, resulting in a large inventory of contaminants in the vadose zone. The objective of the ERT survey was to map plume extents resulting from the legacy discharges. The HGI interpretation of the resistivity data was performed using geometric inversion to interpolate 2D lines into a 3D image. To demonstrate a newly developed geophysical code capability (E4D), the resistivity data were re-processed to fit a full 3D model of the bulk electrical conductivity. This proof-of-concept model inversion was executed in calendar year 2011, as the large dataset was well-suited for the use of high-performance computing. The 3D re-processing of the BC Cribs and Trenches ERT data conducted in 2011 resolved the true bulk electrical conductivity. This means that all of the resistivity data were fit to a single model of the bulk electrical conductivity, with true horizontal and vertical dimensions. This differed from the HGI data interpretation approach that used geometric inversion to process 2D lines independently, which were then interpolated into a 3D image. Both the full 3D re-processing and the 2D interpolation to a 3D image demonstrated a higher electrical conductivity observed immediately beneath the trenches and cribs. The electrical conductivity is strongly correlated with nitrate concentrations, indicating the presence of nitrate and other co-located contaminants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗