Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational Method Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Efficient particle control in systems with large density gradients

Simulations of large density gradients present a number of challenges for direct Monte Carlo methods, since they lead to too few particles in dilute regions and prohibitively many in the dense regions. Here, we propose a particle control methodology that gives the user more control of the number of particles per cell by introducing a variable weight for each particle. The proposed scheme is based on the stochastic weighted particle method, requires only small modifications to DSMC, and exactly conserves mass, momentum, and energy. In validation tests of systems with density ratios of order 102-104, we observe 101-102 times less variance in the dilute region compared to a DSMC solution with the same number of system particles, while introducing a moderate additional computational cost.

DSMC↗

On the Stability of a Linear System of Difference Equations with Random Parameters

We study the asymptotic behavior of solutions to a linear system of difference equation whose right-hand side at each time moment depends not only on the value at the previous moment, but also on a random parameter that takes its values in a given set. We obtain conditions of the Lyapunov stability and the asymptotic stability of the equilibrium position that are valid for all values of the random parameter or with probability 1.

97 MATHEMATICS AND COMPUTING↗

Stochastic modeling of evaporating sprays within a consistent hybrid joint PDF framework

In the present study, a framework for modeling two-phase evaporating flow is presented, which employs an Eulerian-Lagrangian-Lagrangian approach. For the continuous phase, a joint velocity-composition probability density function (PDF) method is used. Opposed to other approaches, such PDF methods require no modeling for turbulent convection and chemical source terms. For the dispersed phase, the PDF of velocity, diameter, temperature, seen gas velocity and seen gas composition is calculated. This provides a unified formulation, which allows to consistently address the different modeling issues associated with such a system. Because of the high dimensionality, particle methods are employed to solve the PDF transport equations. To further enhance computational efficiency, a local particle time-stepping algorithm is implemented and a particle time-averaging technique is employed to reduce statistical and bias errors. In comparison to previous studies, a significantly smaller number of droplet particles per grid cell can be employed for the computations, which rely on two-way coupling between the droplet and gas phases. The framework was validated using established experimental data and a good overall agreement can be observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Studies of EMP generation using a Lienard-Wiechert formulation, and progress toward a 3-D EMP code

Here, we describe studies of the generation of electro-magnetic pulse (EMP) fields under the idealized conditions of a delta-function gamma pulse, a spherical cap of Compton electrons located at a common radius from the burst, and the absence of the conduction current. Various processes (geomagnetic rotation, drag, and scattering) contribute to the time derivative of the Compton current density, which appears as the source term in the Lienard–Wiechert expression for the radiation field. These processes are considered separately and in combination, and their influences on the waveform of the EMP assessed. Using a separate computational approach, different numerical models of multiple scattering are tested, in an effort to assess the validity of existing codes and earlier results. We also describe plans for and progress toward a comprehensive 3-D EMP code, which is to employ recently developed numerical methods and is to offer a variety of models, including the Lienard–Wiechert formulation described here.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computed Tomography Radiomics Predicts HPV Status and Local Tumor Control After Definitive Radiochemotherapy in Head and Neck Squamous Cell Carcinoma

Purpose: This study aimed to predict local tumor control (LC) after radiochemotherapy of head and neck squamous cell carcinoma (HNSCC) and human papillomavirus (HPV) status using computed tomography (CT) radiomics. Methods and Materials: HNSCC patients treated with definitive radiochemotherapy were included in the retrospective study approved by the local ethical commission (93 and 56 patients in the training and validation cohorts, respectively). Three hundred seventeen CT radiomic features, including those based on shape, intensity, texture, and wavelet transform, were calculated in the primary tumor region. Cox and logistic regression models were built to predict LC and HPV status, respectively. The best-performing features in the univariable analysis were included in the multivariable analysis after the exclusion of redundant features. The quality of the models was assessed using the concordance index (CI) for modeling of LC and receiver operating characteristics area under the curve (AUC) for HPV status prediction. The radiomics LC model was compared to a model incorporating clinical parameters (tumor stage, volume, and HPV status) and a mixed model. Results: A radiomic signature comprising 3 features was significantly associated with LC (CI{sub training} = 0.75 and CI{sub validation} = 0.78), showing that tumors with a more heterogeneous CT density distribution are at risk for decreased LC. The addition of clinical parameters to the radiomics model slightly improved the model in the training cohort but not in the validation cohort. Another radiomic signature showed good performance in HPV status prediction (AUC{sub training} = 0.85 and AUC{sub validation} = 0.78) and indicated that HPV-positive tumors have a more homogenous CT density distribution. Conclusions: Heterogeneity of HNSCC tumor density, quantified by CT radiomics, is associated with LC after radiochemotherapy and HPV status.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distinguishing correct from incorrect PML proposals and a corrected unsplit PML for anisotropic, dispersive media

We show that some previous proposals for perfectly matched layer (PML) absorbers in anisotropic media or for waveguides at oblique incidence are not, in fact true PMLs; in previous work we similarly showed a failure of several PML proposals for periodic media (photonic crystals). We therefore argue that a more careful validation scheme is required for PML proposals, in contrast to past authors who have typically checked only that reflections are small for a fixed resolution, and suggest a simple validation scheme that can be readily applied to any PML proposal regardless of derivation or implementation. We demonstrate this test for a corrected, unsplit-field PML valid for anisotropic, dispersive media, implemented in both planewave-expansion and finite-difference time-domain (FDTD) methods.

97 MATHEMATICS AND COMPUTING↗

Classical nuclear motion coupled to electronic non-adiabatic transitions

Based on the exact factorization of the electron-nuclear wave function, we have recently proposed a mixed quantum-classical scheme [A. Abedi, F. Agostini, and E. K. U. Gross, Europhys. Lett. 106, 33001 (2014)] to deal with non-adiabatic processes. Here we present a comprehensive description of the formalism, including the full derivation of the equations of motion. Numerical results are presented for a model system for non-adiabatic charge transfer in order to test the performance of the method and to validate the underlying approximations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of a deformable image registration technique for cone beam CT-based dose verification

Purpose: As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modulated radiotherapy (IMRT) dose based on multimodal deformable image registration (DIR) for prostate treatments. Methods: A pelvic phantom was scanned with CT and cone-beam computed tomography (CBCT). Both images were digitally deformed using two realistic patient-based deformation fields. The original CT was then registered to the deformed CBCT resulting in a secondary deformed CT. The registration quality was assessed as the ability of the DIR method to recover the artificially induced deformations. The primary and secondary deformed CT images as well as vector fields were compared to evaluate the efficacy of the registration method and it’s suitability to be used for dose calculation. PLASTIMATCH, a free and open source software was used for deformable image registration. A B-spline algorithm with optimized parameters was used to achieve the best registration quality. Geometric image evaluation was performed through voxel-based Hounsfield unit (HU) and vector field comparison. For dosimetric evaluation, IMRT treatment plans were created and optimized on the original CT image and recomputed on the two warped images to be compared. The dose volume histograms were compared for the warped structures that were identical in both warped images. This procedure was repeated for the phantom with full, half full, and empty bladder. Results: The results indicated mean HU differences of up to 120 between registered and ground-truth deformed CT images. However, when the CBCT intensities were calibrated using a region of interest (ROI)-based calibration curve, these differences were reduced by up to 60%. Similarly, the mean differences in average vector field lengths decreased from 10.1 to 2.5 mm when CBCT was calibrated prior to registration. The results showed no dependence on the level of bladder filling. In comparison with the dose calculated on the primary deformed CT, differences in mean dose averaged over all organs were 0.2% and 3.9% for dose calculated on the secondary deformed CT with and without CBCT calibration, respectively, and 0.5% for dose calculated directly on the calibrated CBCT, for the full-bladder scenario. Gamma analysis for the distance to agreement of 2 mm and 2% of prescribed dose indicated a pass rate of 100% for both cases involving calibrated CBCT and on average 86% without CBCT calibration. Conclusions: Using deformable registration on the planning CT images to evaluate the IMRT dose based on daily CBCTs was found feasible. The proposed method will provide an accurate dose distribution using planning CT and pretreatment CBCT data, avoiding the additional uncertainties introduced by CBCT inhomogeneity and artifacts. This is a necessary initial step toward future image-guided adaptive radiotherapy of the prostate.

60 APPLIED LIFE SCIENCES↗

Operational Reactor Depletion Analysis Capability

The milestone for the operational reactor depletion demonstrates a cycle depletion simulation of Watt's Bar Unit 1 Cycle 1. The simulation was performed using the VERA-CS components MPACT and COBRA-TF. The simulation was performed on the Titan and Eos machines at the Oak Ridge Leadership Computing Facility. The simulation results include the critical boron concentration, the pin resolved power, temperature, and fluid density distributions, and detector responses as a function of time. These results are presented and the critical boron concentration is compared with measured data. The comparison is reasonable given the modeling approximation used at this point. Several suggestions, both near and longer term, are given for areas of future work which include improving the methods, data, models, and computational performance. For those solution results which are not compared to measurement, e.g. power and temperature distributions, their behavior coincides with analysts' expectations. An important next step in the validation of VERA-CS will be the comparison of the computational results to the measured flux data. To satisfy this L1 milestone, numerous capabilities were successfully added as a part of supporting L2 and L3 milestones. These include: full core depletion, generation of a new cross section library, coupling of neutronics and thermal hydraulic feedback, and detector response modeling. In addition to the operational reactor depletion, several 2-D core parametric studies were performed to assess the new simulation capability and to develop guidelines on model approximations and discretizations. Some of the conclusions from these studies are: • The simulation of B-10 depletion in the coolant is necessary to accurately predict critical boron concentrations, • If the end of cycle state is of primary interest in the simulation, then significant approximations may be made in the cycle history. The ability to make use of this approximation without a notable loss in accuracy will considerably accelerate multi-cycle analysis, • The new 47-group cross section library with a transport correction of the P 0 scattering can provide solutions very efficiently and which are nearly as accurate as solutions generated with explicit P 2 scattering, and • Simplified modeling of the equilibrium xenon concentration is well predicted by the existing depletion solver, and only in certain circumstances (e.g. large and "instantaneous" changes to rod position or T/H conditions) would an explicit physical model need to be included. Overall the milestone is considered a success as the objectives were met and several new and important results were produced from this work. The results and conclusions of this milestone will continue to guide future work and become the basis for addressing the CASL Challenge Problems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Howard A. Hanson Dam Juvenile Fish Passage and Survival Study Live Fish Injury Assessment, Sensor Fish, and BioPA Modeling Tasks

The live fish injury assessment, Sensor Fish, and BioPA modeling study tasks were conducted by researchers from Pacific Northwest National Laboratory (PNNL). The four tasks were part of the larger Evaluation of Howard A. Hanson Dam (HAHD) Juvenile Fish Passage and Survival study, which had six total tasks. To achieve study objectives for each of the four tasks, field work occurred at Green Peter Dam (GPR) to evaluate the highest elevation steep slope bypass pipe, at HAHD to evaluate baseline conditions of the horseshoe tunnel, and at PNNL’s Aquatic Research Laboratory (ARL) to evaluate simulated dam passage conditions (i.e., shear forces and collision). Each of these evaluations utilized live fish injury assessment, Sensor Fish, and BioPA modeling. Live fish injury assessment and survival (tagged with and without balloon or passive integrated transponder [PIT] tags) was correlated with Sensor Fish to determine thresholds. The CFD analyses were then performed, and the computed values were compared to the corresponding measured values of Sensor Fish data. The results of the overall injury and survival of fish was also used in the validation of the CFD modeling method. Collectively, the results will aid in future modeling of fish passage at HAHD. Results from these tasks can be used by biologists, engineers, resource managers, and regional decision-makers to inform baseline conditions under current operations and the engineering design of the new FPF at HAHD. This draft report contains initial data and results from the four tasks. Table 8 1, Table 8 2, and Table 8 3, and Figure 8 1, Figure 8 2, and Figure 8 3 depict the CFD modeling findings for the GPR steep slope bypass, HAHD horseshoe tunnel, and laboratory testing. Table 8 4, Table 8 5, and Table 8 6 depict the Sensor Fish findings for the GPR steep slope bypass and HAHD horseshoe tunnel testing. The Mv values observed in the HAHD were significantly lower compared to the laboratory experiments conducted at PNNL. Currently, investigations are underway to understand the reasons for this disparity and to establish an appropriate threshold value for Mv. Survival predictions presented in the tables below should be considered preliminary and should not be used until further analyses and adjustments are completed. The next steps for modeling will include the flow regime, (i.e., density of flow regimes due to water and air mixing ) to continue to improve on the threshold value for Mv.

13 HYDRO ENERGY↗

Dual-purpose canister filling simulation and validation: Part II- Validation

A mock up spent fuel canister test section is designed and built at Oak Ridge National Laboratory to support the R&D efforts on the direct disposal of dual purpose spent fuel canisters. The objective of the experimental testing is to investigate feasibility and to identify the unknown to gain confidence in the filing process and to validate computational models designed to simulate the process. The scope of the initial studies is to validate single-physics scaled testing of flow simulation to determine injectability, void filling, filling time, and filling method (gravity vs. pump).

Cetiner, Nesrin↗

Experimentally Validated Computational Modeling of Creep and Creep-Cracking for Nuclear Concrete Structures

In a Nuclear Power Plant, one of the most important components is the concrete nuclear reactor cavity, which serves both a structural and protective function as the biological radiation shield. Given that creep has been identified as a major knowledge gap in the assessment of nuclear structures (NUREG/CR-7153), this work helps to further the understanding of creep behavior of massive concrete containment structures for decades to enable safe and long-term operation of these facilities. This project has developed a robust, experimentally validated model to predict creep in nuclear concrete structures for up 60 years using short-term creep data thereby enabling a longer service life of critical facilities and early detection of structural failure. The work presented in this report is a pairing of computational and experimental methods. For the first time, the time temperature superposition (TTS) principle was successfully used to generate a uniaxial creep compliance master curve to predict mortar creep response for up to 22,500 days (nearly 60 years) at a reference temperature of 20°C. These data were used as input into finite element analysis (FEA) codes that use highly realistic random, 3D concrete microstructures from reconstructed coarse limestone aggregates. Finite element analysis performed provides the ability to quickly upscale mortar viscoelastic behavior to long-term concrete creep/relaxation data. A master creep compliance curve, constructed from the TTS principle, spanning 27 years, was used to validate two and a half decades of simulated concrete creep. Concurrently, three different simulated wall specimens were designed to mimic the behavior of post-tensioned concrete nuclear containment facility vessel walls over time as a result of concrete creep. The specimens were designed with different thicknesses, transverse and longitudinal reinforcement ratios, and level of post-tensioning stress. Each specimen contained various instrumentation to measure internal concrete temperature, concrete strain, and post-tensioning strain hourly for over 3 years. The concrete creep model developed in this project, based on the FEA concrete simulations, was applied to simulate the structural-scale experiments of prestressed concrete walls conducted in this project using the Grizzly code. These models can represent the effects of reinforcing and prestressing. Although there are some discrepancies with the experimental data, the model can predict the overall trends of the creep response in these experiments. One of these experimental models was also applied to an extended time to demonstrate how the findings from this study can be used to predict the behavior of actual structures of interest that have been in service for extended periods of time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Study on the Effects of a Viscous Fluid Surrounding a Small Electrical Assembly

Currently there are limitations in computing chatter behavior of small electrical contacts embedded in components using finite element models. Reduced order models (ROM) have been developed of such electrical contact sub-assemblies to assess the chatter behavior of the contacts during vibration and shock environments. The current ROM method requires experimental validation. This ROM also neglects the frequency and damping effects of the viscous fluid that typically surrounds such sub-assemblies. Dynamic ring-down testing of the electrical contacts in air will be performed and will provide a validation data set for the current ROM. Additionally, dynamic ring-down testing of the electrical contact will be performed in fluids of varying viscosities that will help characterize the effect of the fluid on the contact for an improved ROM.

97 MATHEMATICS AND COMPUTING↗

Simulations of nonradiative processes in semiconductor nanocrystals

The description of carrier dynamics in spatially confined semiconductor nanocrystals (NCs), which have enhanced electron–hole and exciton–phonon interactions, is a great challenge for modern computational science. These NCs typically contain thousands of atoms and tens of thousands of valence electrons with discrete spectra at low excitation energies, similar to atoms and molecules, that converge to the continuum bulk limit at higher energies. Computational methods developed for molecules are limited to very small nanoclusters, and methods for bulk systems with periodic boundary conditions are not suitable due to the lack of translational symmetry in NCs. This perspective focuses on our recent efforts in developing a unified atomistic model based on the semiempirical pseudopotential approach, which is parameterized by first-principle calculations and validated against experimental measurements, to describe two of the main nonradiative relaxation processes of quantum confined excitons: exciton cooling and Auger recombination. Here, we focus on the description of both electron–hole and exciton–phonon interactions in our approach and discuss the role of size, shape, and interfacing on the electronic properties and dynamics for II–VI and III–V semiconductor NCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-C-BRA-05: Delineating High-Dose Clinical Target Volumes for Head and Neck Tumors Using Machine Learning Algorithms

Purpose: To develop and test population-based machine learning algorithms for delineating high-dose clinical target volumes (CTVs) in H&N tumors. Automating and standardizing the contouring of CTVs can reduce both physician contouring time and inter-physician variability, which is one of the largest sources of uncertainty in H&N radiotherapy. Methods: Twenty-five node-negative patients treated with definitive radiotherapy were selected (6 right base of tongue, 11 left and 9 right tonsil). All patients had GTV and CTVs manually contoured by an experienced radiation oncologist prior to treatment. This contouring process, which is driven by anatomical, pathological, and patient specific information, typically results in non-uniform margin expansions about the GTV. Therefore, we tested two methods to delineate high-dose CTV given a manually-contoured GTV: (1) regression-support vector machines(SVM) and (2) classification-SVM. These models were trained and tested on each patient group using leave-one-out cross-validation. The volume difference(VD) and Dice similarity coefficient(DSC) between the manual and auto-contoured CTV were calculated to evaluate the results. Distances from GTV-to-CTV were computed about each patient’s GTV and these distances, in addition to distances from GTV to surrounding anatomy in the expansion direction, were utilized in the regression-SVM method. The classification-SVM method used categorical voxel-information (GTV, selected anatomical structures, else) from a 3×3×3cm3 ROI centered about the voxel to classify voxels as CTV. Results: Volumes for the auto-contoured CTVs ranged from 17.1 to 149.1cc and 17.4 to 151.9cc; the average(range) VD between manual and auto-contoured CTV were 0.93 (0.48–1.59) and 1.16(0.48–1.97); while average(range) DSC values were 0.75(0.59–0.88) and 0.74(0.59–0.81) for the regression-SVM and classification-SVM methods, respectively. Conclusion: We developed two novel machine learning methods to delineate high-dose CTV for H&N patients. Both methods showed promising results that hint to a solution to the standardization of the contouring process of clinical target volumes. Varian Medical Systems grant.

60 APPLIED LIFE SCIENCES↗

Steps towards verification and validation of the Fetch code for Level 2 analysis, design, and optimization of aqueous homogeneous reactors

Babcock and Wilcox Technical Services Group (B and W) has identified aqueous homogeneous reactors (AHRs) as a technology well suited to produce the medical isotope molybdenum 99 (Mo-99). AHRs have never been specifically designed or built for this specialized purpose. However, AHRs have a proven history of being safe research reactors. In fact, in 1958, AHRs had 'a longer history of operation than any other type of research reactor using enriched fuel' and had 'experimentally demonstrated to be among the safest of all various type of research reactor now in use [1].' While AHRs have been modeled effectively using simplified 'Level 1' tools, the complex interactions between fluids, neutronics, and solid structures are important (but not necessarily safety significant). These interactions require a 'Level 2' modeling tool. Imperial College London (ICL) has developed such a tool: Finite Element Transient Criticality (FETCH). FETCH couples the radiation transport code EVENT with the computational fluid dynamics code (Fluidity), the result is a code capable of modeling sub-critical, critical, and super-critical solutions in both two-and three-dimensions. Using FETCH, ICL researchers and B and W engineers have studied many fissioning solution systems include the Tokaimura criticality accident, the Y12 accident, SILENE, TRACY, and SUPO. These modeling efforts will ultimately be incorporated into FETCH'S extensive automated verification and validation (V and V) test suite expanding FETCH'S area of applicability to include all relevant physics associated with AHRs. These efforts parallel B and W's engineering effort to design and optimize an AHR to produce Mo99. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-184: Stereo Time-Of-Flight System for Patient Positioning in Radiotherapy

Purpose: The objective of this work is to test the advantage of using the surface acquired by two stereo Time-of-Flight (ToF) cameras in comparison of the use of one camera only for patient positioning in radiotherapy. Methods: A first step consisted on validating the use of a stereo ToFcamera system for positioning management of a phantom mounted on a linear actuator producing very accurate and repeatable displacements. The displacements between two positions were computed from the surface point cloud acquired by either one or two cameras thanks to an iterative closest point algorithm. A second step consisted on determining the displacements on patient datasets, with two cameras fixed on the ceiling of the radiotherapy room. Measurements were done first on voluntary subject with fixed translations, then on patients during the normal clinical radiotherapy routine. Results: The phantom tests showed a major improvement in lateral and depth axis for motions above 10 mm when using the stereo-system instead of a unique camera (Fig1). Patient measurements validate these results with a mean real and measured displacement differences in the depth direction of 1.5 mm when using one camera and 0.9 mm when using two cameras (Fig2). In the lateral direction, a mean difference of 1 mm was obtained by the stereo-system instead of 3.2 mm. Along the longitudinal axis mean differences of 5.4 and 3.4 mm with one and two cameras respectively were noticed but these measurements were still inaccurate and globally underestimated in this direction as in the literature. Similar results were also found for patient subjects with a mean difference reduction of 35%, 7%, and 25% for the lateral, depth, and longitudinal displacement with the stereo-system. Conclusion: The addition of a second ToF-camera to determine patient displacement strongly improved patient repositioning results and therefore insures better radiation delivery.

60 APPLIED LIFE SCIENCES↗

Development of MOSCATO: A CFD-Level Electrochemistry and Corrosion Simulator for Molten Salt Systems

For both coolant and fueled variants of molten salt reactors (MSRs), the corrosion of structural materials is a significant challenge. The corrosion stems from chemical and electrochemical reactions initiated by fissile material, fission products, and impurities in the salt. Lower-fidelity models rely on empirical correlations for mass transfer, simplified lumped temperature profiles, and similar assumptions. They do not capture detailed spatial variations in complex geometries, creating the need for high-fidelity modeling to bridge this gap.As we approach the demonstration and possible deployment of MSRs in this decade, the development of a high-fidelity, high-performance simulator becomes imperative. To simulate the complex electrochemical environment and corrosion within molten salt systems, we have developed the Molten Salt Chemistry And TranspOrt (MOSCATO) code. This endeavor is comprised of three essential components. First, mass transfer equations are coupled with the Navier-Stokes equations in order to account for the transport of species in the salt. Second, the diffusion of alloy constituents, such as Cr, Fe, Ni, etc. is simulated within the structural metals. Third, the alloy and salt domains are coupled to account for the heterogeneous chemical and electrochemical reactions that occur at the salt-alloy interface.MOSCATO manages all three components within the framework of the highly scalable, open-source spectral element method computational fluid dynamics code Nek5000/NekRS. This integration enables MOSCATO to harness the immense computational power of modern high-performance computing resources, ensuring both high fidelity and computational speed.In addition to code development, we have initiated a comprehensive verification and validation campaign, utilizing data from diverse sources. First, MOSCATO's electrochemical solver was verified with reference numerical data. Then validation occurred against experiments: one of a thermal galvanic cell and the other for corrosion in flowing molten salt of FLiNaK (LiF-NaF-KF). This campaign verified and validated MOSCATO as a reliable tool for simulating electrochemical environments and corrosion in molten salt systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗