Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Renewable Electricity Futures for the United States

This paper highlights the key results from the Renewable Electricity (RE) Futures Study. It is a detailed consideration of renewable electricity in the United States. The paper focuses on technical issues related to the operability of the U. S. electricity grid and provides initial answers to important questions about the integration of high penetrations of renewable electricity technologies from a national perspective. The results indicate that the future U. S. electricity system that is largely powered by renewable sources is possible and the further work is warranted to investigate this clean generation pathway. The central conclusion of the analysis is that renewable electricity generation from technologies that are commercially available today, in combination with a more flexible electric system, is more than adequate to supply 80% of the total U. S. electricity generation in 2050 while meeting electricity demand on an hourly basis in every region of the United States.

Energy storage↗

Reversionary Control Modes for the Mitigation of Failures in a Partially Turboelectric Aircraft Propulsion System

In support of emission and fuel burn reduction goals, the aviation industry is actively pursuing the advancement of electrified aircraft propulsion (EAP) technology. This includes turboelectric and hybrid electric propulsion designs that combine gas turbine engine and electrical system hardware. Such architectures exhibit a high degree of coupling between subsystems. This drives the need for system-level control strategies to ensure the safe, coordinated, and efficient operation of all subsystems. The design and certification of any aircraft propulsion system requires that all potential subsystem failures are identified, and the hazards posed by these failures are appropriately mitigated. This requirement is particularly challenging for EAP systems due to their integrated nature. One approach to assist in EAP failure mitigation is the inclusion of automated reconfiguration capabilities within the propulsion control system. Such control modes, referred to as reversionary control modes, are designed to automatically detect failures and activate backup control modes upon failure detection. This paper covers the design and evaluation of reversionary control mode logic developed for a partially turboelectric propulsion concept. Test results from a real-time hardware-in-the-loop evaluation of the concept are also presented and discussed. The results show that the developed reversionary control logic can successfully detect and mitigate subsystem failures in a representative environment that includes actual electrical system hardware.

Electrified Aircraft Propulsion↗

Reversionary Control Modes for the Mitigation of Failures in a Partially Turboelectric Aircraft Propulsion System

In support of emission and fuel burn reduction goals, the aviation industry is actively pursuing the advancement of electrified aircraft propulsion (EAP) technology. This includes turboelectric and hybrid electric propulsion designs that combine gas turbine engine and electrical system hardware. Such architectures exhibit a high degree of coupling between subsystems. This drives the need for system-level control strategies to ensure the safe, coordinated, and efficient operation of all subsystems. The design and certification of any aircraft propulsion system requires that all potential subsystem failures are identified, and the hazards posed by these failures are appropriately mitigated. This requirement is particularly challenging for EAP systems due to their integrated nature. One approach to assist in EAP failure mitigation is the inclusion of automated reconfiguration capabilities within the propulsion control system. Such control modes, referred to as reversionary control modes, are designed to automatically detect failures and activate backup control modes upon failure detection. This paper covers the design and evaluation of reversionary control mode logic developed for a partially turboelectric propulsion concept. Test results from a real-time hardware-in-the-loop evaluation of the concept are also presented and discussed. The results show that the developed reversionary control logic can successfully detect and mitigate subsystem failures in a representative environment that includes actual electrical system hardware.

Electrified Aircraft Propulsion↗

Reversionary Control Modes for the Mitigation of Failures in a Partially Turboelectric Aircraft Propulsion System

In support of emission and fuel burn reduction goals, the aviation industry is actively pursuing the advancement of electrified aircraft propulsion (EAP) technology. This includes turboelectric and hybrid electric propulsion designs that combine gas turbine engine and electrical system hardware. Such architectures exhibit a high degree of coupling between subsystems. This drives the need for system-level control strategies to ensure the safe, coordinated, and efficient operation of all subsystems. The design and certification of any aircraft propulsion system requires that all potential subsystem failures are identified, and the hazards posed by these failures are appropriately mitigated. This requirement is particularly challenging for EAP systems due to their integrated nature. One approach to assist in EAP failure mitigation is the inclusion of automated reconfiguration capabilities within the propulsion control system. Such control modes, referred to as reversionary control modes, are designed to automatically detect failures and activate backup control modes upon failure detection. This paper covers the design and evaluation of reversionary control mode logic developed for a partially turboelectric propulsion concept. Test results from a real-time hardware-in-the-loop evaluation of the concept are also presented and discussed. The results show that the developed reversionary control logic can successfully detect and mitigate subsystem failures in a representative environment that includes actual electrical system hardware.

Electrified Aircraft Propulsion↗

Summary of Electric Distribution System Analyses with a Focus on DERs

Commonly used distribution system analyses (DSAs) include power flow, power quality, fault analysis and dynamic analysis. The DSA tools are often used by the electric distribution planning engineers to conduct different types of analyses. This paper has investigated the capability of ten DSA tools, including both commercial and open-source ones. The maturity levels of the DSA analyses and the corresponding studies are summarized based on percentage of the DSA tools capable of conducting each type of analysis. With increasing distributed energy resources (DERs) being integrated into the distribution system, detailed DER studies need to be conducted to investigate the potential effects of DERs on the grid. The DSAs associated with DERs are discussed, along with their relative maturity and tool capabilities to conduct the DER impact studies. This paper is to provide an overview of the DSAs that assist in analyzing DER impacts, the DSAs as the way to enable or support market activities on the distribution systems, and investigate the capability and gap of existing DSA tools to conduct DER studies.

Distribution Analysis, Distributed Energy Resource↗

Developing a Reduced 240-Bus WECC Dynamic Model for Frequency Response Study of High Renewable Integration

The ongoing changes in the generation resource mix, driven by the rapid adoption of inverter-based resources (IBR) as well as the early retirement of synchronous generators, are bringing new challenges to the planning and operation of bulk electric power systems. Consequently, there is an increasing need to understand, design, and quantify the reliability service provision from IBRs by performing integrated scheduling and dynamic simulations. However, test systems that have consistent scheduling and dynamic models rarely exist largely because of the decoupled nature of the two simulations on a synchronous generator-dominated system. This paper develops the dynamic model of a reduced Western Electricity Coordinating Council (WECC) system. In conjunction with the existing scheduling model, it is suitable for integrating scheduling and dynamic simulations. The reduced 240-bus WECC model reflects the generation resource mix of the Western Interconnection as of 2018. Moreover, the developed dynamic model is validated against field frequency events measured by FNET/GridEye and preserves the dominant inter-area oscillation mode in WECC.

dynamic simulation↗

Design and Analysis of a 200 kW Dynamic Wireless Charging System for Electric Vehicles

Dynamic wireless charging of electric vehicles can significantly alleviate or eliminate range anxiety while reducing the required on-board battery capacity. To achieve an electric vehicle charging balance with minimal infrastructure costs, power transfer levels around 200 kW are required. In this paper, a system architecture with a modularized power electronics and optimized power transfer couplers was adopted to enable efficient power transfer. A DC/DC converter was used for secondary-side charging control of the battery. The system performance was validated in an experimental setup at 120 kW with 91.31% efficiency from the DC input on the primary side to the vehicle battery.

Xue, Lincoln↗

Turbofan Engine Power Extraction Demonstration Final Report

As GE Aerospace advances toward a revolutionary step change in propulsion efficiency, the integration and demonstration of new engine architectures and technology systems are essential. The NASA Turbofan Engine Power Extraction Demonstration (PEx), conducted through the Hybrid Thermally Efficient Core (HyTEC) project, aims to develop and demonstrate megawatt-class hybrid electric capability on a modern commercial turbofan engine. The hybrid electric system is critical to meeting the needs of the U.S. aviation industry for next-generational propulsion systems with greater efficiency, durability, and range. This supports energy independence and helps ensure the security and resilience of one of America's largest export industries. The PEx project specifically targets three key objectives: mechanically integrating hybrid electric capability into a commercial turbofan engine, integrating electric machine control with turbofan control for advanced power management, and de-risking performance modeling of future hybrid electric architectures. To mature these technologies to Technology Readiness Level (TRL) 6, a series of electric power system component tests and a baseline engine performance test campaign were conducted. These efforts culminated in an integrated hybrid electric turbofan test campaign demonstrating power extraction, power insertion, and power transfer between spools. Tests of the electric power system were completed at GE Aerospace’s Electrical Power Integrated Systems Center in Dayton, Ohio and engine tests were completed at Peebles Test Operation in Peebles, Ohio. Hybrid electric trade studies extended the demonstrated capability to altitude using the validated cycle model from the PEx test campaigns, allowing for comments on expanded mission benefits not demonstrated in the ground campaign. The knowledge gained from PEx also supports GE Aerospace’s Compact Core Demonstrator as part of HyTEC Phase 2 and ultimately informs the implementation of hybrid electric systems in the next generation of GE Aerospace commercial engine products. This report provides a summary of the program background, test campaigns, trade studies, and insights into the technical maturation required to support future commercial products.

Hybrid Electric↗

Advanced Methods for Incorporating Solar Energy Technologies into Electric Sector Capacity-Expansion Models: Literature Review and Analysis

Because solar power is a rapidly growing component of the electricity system, robust representations of solar technologies should be included in capacity-expansion models. This is a challenge because modeling the electricity system--and, in particular, modeling solar integration within that system--is a complex endeavor. This report highlights the major challenges of incorporating solar technologies into capacity-expansion models and shows examples of how specific models address those challenges. These challenges include modeling non-dispatchable technologies, determining which solar technologies to model, choosing a spatial resolution, incorporating a solar resource assessment, and accounting for solar generation variability and uncertainty.

14 SOLAR ENERGY↗

Representation of Solar Capacity Value in the ReEDS Capacity Expansion Model

An important issue for electricity system operators is the estimation of renewables' capacity contributions to reliably meeting system demand, or their capacity value. While the capacity value of thermal generation can be estimated easily, assessment of wind and solar requires a more nuanced approach due to the resource variability. Reliability-based methods, particularly assessment of the Effective Load-Carrying Capacity, are considered to be the most robust and widely-accepted techniques for addressing this resource variability. This report compares estimates of solar PV capacity value by the Regional Energy Deployment System (ReEDS) capacity expansion model against two sources. The first comparison is against values published by utilities or other entities for known electrical systems at existing solar penetration levels. The second comparison is against a time-series ELCC simulation tool for high renewable penetration scenarios in the Western Interconnection. Results from the ReEDS model are found to compare well with both comparisons, despite being resolved at a super-hourly temporal resolution. Two results are relevant for other capacity-based models that use a super-hourly resolution to model solar capacity value. First, solar capacity value should not be parameterized as a static value, but must decay with increasing penetration. This is because -- for an afternoon-peaking system -- as solar penetration increases, the system's peak net load shifts to later in the day -- when solar output is lower. Second, long-term planning models should determine system adequacy requirements in each time period in order to approximate LOLP calculations. Within the ReEDS model we resolve these issues by using a capacity value estimate that varies by time-slice. Within each time period the net load and shadow price on ReEDS's planning reserve constraint signals the relative importance of additional firm capacity.

14 SOLAR ENERGY↗

Exploring Propulsion System Requirements for More and All-Electric Helicopters

Helicopters offer unique capabilities that are important for certain missions. More and all-electric propulsion systems for helicopters offer the potential for improved efficiency, reliability, vehicle and mission capabilities as well as reduced harmful emissions. To achieve these propulsion system-based benefits, the relevant requirements must be understood and developed for the various component, sub-component and ancillary systems of the overall propulsion system. Three representative helicopters were used to explore propulsion and overall vehicle and mission requirements. These vehicles varied from light utility (one to three occupants) to highly capable (three crew members plus ten passengers and cargo). Assuming 15 and 30 year technology availability, analytical models for electric system components were developed to understand component and ancillary requirements. Overall propulsion system characteristics were developed and used for vehicle sizing and mission analyses to understand the tradeoffs of component performance and weight, with increase in vehicle size and mission capability. Study results indicate that only the light utility vehicle retained significant payload for an arbitrary 100 nautical mile range assuming 15 year technology. Thirty year technology assumptions for battery energy storage are sufficient to enable some range and payload capabilities, but further improvements in energy density are required to maintain or exceed payload and range capabilities versus present systems. Hydrocarbon-fueled range extenders can be prudently used to recover range and payload deficiencies resulting from battery energy density limitations. Thermal loads for electric systems are low heat quality, but seem manageable. To realize the benefits from more and all-electric systems, technology goals must be achieved, as well as identify vehicles, missions and systems that are best suited to take advantage of their unique characteristics.

gearbox↗

Exploring Propulsion System Requirements for More and All-Electric Helicopters

Helicopters offer unique capabilities that are important for certain missions. More and all-electric propulsion systems for helicopters offer the potential for improved efficiency, reliability, vehicle and mission capabilities as well as reduced harmful emissions. To achieve these propulsion system-based benefits, the relevant requirements must be understood and developed for the various component, sub-component and ancillary systems of the overall propulsion system. Three representative helicopters were used to explore propulsion and overall vehicle and mission requirements. These vehicles varied from light utility (one to three occupants) to highly capable (three crew members plus ten passengers and cargo). Assuming 15 and 30 year technology availability, analytical models for electric system components were developed to understand component and ancillary requirements. Overall propulsion system characteristics were developed and used for vehicle sizing and mission analyses to understand the tradeoffs of component performance and weight, with increase in vehicle size and mission capability. Study results indicate that only the light utility vehicle retained significant payload for an arbitrary 100 nautical mile range assuming 15 year technology. Thirty year technology assumptions for battery energy storage are sufficient to enable some range and payload capabilities, but further improvements in energy density are required to maintain or exceed payload and range capabilities versus present systems. Hydrocarbon-fueled range extenders can be prudently used to recover range and payload deficiencies resulting from battery energy density limitations. Thermal loads for electric systems are low heat quality, but seem manageable. To realize the benefits from more and all-electric systems, technology goals must be achieved, as well as vehicles, missions and systems identified that are best suited to take advantage of their unique characteristics.

mission analysis↗

Achieving a 100% Renewable Grid: Operating Electric Power Systems with Extremely High Levels of Variable Renewable Energy

What does it mean to achieve a 100% renewable grid? Several countries already meet or come close to achieving this goal. Iceland, for example, supplies 100% of its electricity needs with either geothermal or hydropower. Other countries that have electric grids with high fractions of renewables based on hydropower include Norway (97%), Costa Rica (93%), Brazil (76%), and Canada (62%). Hydropower plants have been used for decades to create a relatively inexpensive, renewable form of energy, but these systems are limited by natural rainfall and geographic topology. Around the world, most good sites for large hydropower resources have already been developed. So how do other areas achieve 100% renewable grids? Variable renewable energy (VRE), such as wind and solar photovoltaic (PV) systems, will be a major contributor, and with the reduction in costs for these technologies during the last five years, large-scale deployments are happening around the world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dual-purpose self-deliverable lunar surface PV electrical power system

A safe haven and work supported PV power systems on the lunar surface will likely be required by NASA in support of the manned outpost scheduled for the post-2000 lunar/Mars exploration and colonization initiative. Initial system modeling and computer analysis shows that the concept is workable and contains no major high risk technology issues which cannot be resolved in the circa 2000 to 2025 timeframe. A specific selection of the best suited type of electric thruster has not been done; the initial modeling was done using an ion thruster, but Rocketdyne must also evaluate arc and resisto-jets before a final design can be formulated. As a general observation, it appears that such a system can deliver itself to the Moon using many system elements that must be transported as dead payload mass in more conventional delivery modes. It further appears that a larger power system providing a much higher safe haven power level is feasible if this delivery system is implemented, perhaps even sufficient to permit resource prospecting and/or lab experimentation. The concept permits growth and can be expanded to include cargo transport such as habitat and working modules. In short, the combined payload could be manned soon after landing and checkout. NASA has expended substantial resources in the development of electric propulsion concepts and hardware that can be applied to a lunar transport system such as described herein. In short, the paper may represent a viable mission on which previous investments play an invaluable role. A more comprehensive technical paper which embodies second generation analysis and system size will be prepared for near-term presentation.

Arnold, Jack H.↗

Understanding the Capabilities and Limitations of the Controls and Operations of High Voltage Direct Current (HVdc) Converters in Interconnected Electric Power Systems

This project will seek to build a fundamental understanding, and capability, to model and simulate the controls and operations of high voltage direct current (HVdc) converter stations in an electromagnetic simulation environment. While HVdc stations have been operated in the United States for over 50 years, these are typically simple two terminal point-to-point systems. Recently multi-terminal systems have begun to be deployed. The challenge with these new multi-terminal systems is that they often use different control schemes on the different terminals. The interactions of existing and new controls, and the fact that HVdc systems are rates in the 1,000’s of MWs means that small control instabilities can have dramatic impacts to bulk power systems. Despite these challenges, the operational capabilities of HVdc make them an attractive option for the transfer of the large amounts of renewable electricity that will be necessary for decarbonization of the nation’s electrical infrastructure and other sectors.

42 ENGINEERING↗

Discharging a DC bus capacitor of an electrical converter system

A system and method of discharging a bus capacitor of a bidirectional matrix converter of a vehicle are presented here. The method begins by electrically shorting the AC interface of the converter after an AC energy source is disconnected from the AC interface. The method continues by arranging a plurality of switching elements of a second energy conversion module into a discharge configuration to establish an electrical current path from a first terminal of an isolation module, through an inductive element, and to a second terminal of the isolation module. The method also modulates a plurality of switching elements of a first energy conversion module, while maintaining the discharge configuration of the second energy conversion module, to at least partially discharge a DC bus capacitor.

30 DIRECT ENERGY CONVERSION↗

Interoperability Strategic Vision

The Interoperability Strategic Vision whitepaper aims to promote a common understanding of the meaning and characteristics of interoperability and to provide a strategy to advance the state of interoperability as applied to integration challenges facing grid modernization. This includes addressing the quality of integrating devices and systems and the discipline to improve the process of successfully integrating these components as business models and information technology improve over time. The strategic vision for interoperability described in this document applies throughout the electric energy generation, delivery, and end-use supply chain. Its scope includes interactive technologies and business processes from bulk energy levels to lower voltage level equipment and the millions of appliances that are becoming equipped with processing power and communication interfaces. A transformational aspect of a vision for interoperability in the future electric system is the coordinated operation of intelligent devices and systems at the edges of grid infrastructure. This challenge offers an example for addressing interoperability concerns throughout the electric system.

24 POWER TRANSMISSION AND DISTRIBUTION↗