Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Dynamic fault weakening and strengthening by gouge compaction and dilatancy in a fluid-saturated fault zone

Fault gouge deformation likely plays a significant role in controlling the strength of mature, large-displacement faults. Experiments show that intact gouge deforms in an overall ductile and stable manner, readily compacting, but dilates and experiences brittle failure under large strain rate. Inelastic gouge compaction and dilatancy are modeled here using a combined Mohr-Coulomb and end-cap yield criterion in a dynamic rupture model of a strike-slip fault with strongly velocity-weakening friction. We show that large shear stress concentration ahead of the rupture associated with the rupture front causes the gouge layer to compact (e.g., by structural collapse and comminution), leading to rapidly elevated pore pressure and significant weakening of the principal fault surface. Shortly after the rupture front passes, strong dilatancy during strength drop and rapid sliding reduces pore pressure and strengthens the fault, promoting slip pulses. Large strain localization in the gouge layer occurs as a result of rapid gouge dilatancy and strain softening. The combination of prerupture weakening from compaction and restrengthening from dilatancy hardening leads to a smaller-strength drop, and limits the stress concentration outside the gouge layer. Furthermore, this leads to a reduction of inelastic shear strain in the damage zone, which is more consistent with geological observations and high-speed frictional experiments. With the presence of well-developed fault gouge, the strength of mature faults may be limited by end-cap rather than Mohr-Coulomb failure; thus, their frictional strengths are significantly smaller than Byerlee friction.

58 GEOSCIENCES↗

Matched Cohort Analysis of Outcomes of Definitive Radiotherapy for Prostate Cancer in Human Immunodeficiency Virus-Positive Patients

Purpose: To compare the biochemical outcome and toxicity scores of men with human immunodeficiency virus (HIV) and prostate cancer with a matched control population with negative or unknown HIV status when treated with external-beam radiotherapy (EBRT). Methods and Materials: A single-institution database of men with prostate cancer treated with EBRT from 1999 to 2009 was reviewed. Thirteen men with HIV were identified and matched to 2 control patients according to age, race, T stage, prostate-specific antigen level, Gleason score, RT dose, intensity-modulated RT vs. three-dimensional conformal RT, and whole-pelvis vs. prostate-only RT, for a total of 39 cases. The median follow-up time was 39 months (range, 3-110 months). Results: The 4-year biochemical failure (BF)-free survival rate was 87% in the HIV-positive group vs. 89% in the controls (p = 0.94). Pre- and post-RT viral loads were found to be predictive of BF (p = 0.04 and p = 0.04, respectively). No men with HIV died, whereas 2 in the control group died of causes unrelated to prostate cancer. Acute and chronic genitourinary and gastrointestinal toxicity were less in the HIV-positive patients than in controls (p < 0.001, p < 0.001, p = 0.003, and p < 0.001, respectively). The HIV-positive men experienced an average decline in CD4 count of 193 cells/mm{sup 3}. Conclusions: Our findings suggest that men with HIV treated with EBRT have a similar risk of BF; however, high viral loads may contribute to an increased risk. This analysis supports that HIV-positive men with prostate cancer can be treated with definitive EBRT with similar disease control and toxicity outcomes as in the general population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Embolization Before Liver Resection: A Systematic Review

This is a review of literature on the indications, technique, and outcome of portal vein embolization (PVE). A systematic literature search on outcome of PVE from 1990 to 2011 was performed in Medline, Cochrane, and Embase databases. Forty-four articles were selected, including 1,791 patients with a mean age of 61 {+-} 4.1 years. Overall technical success rate was 99.3 %. The mean hypertrophy rate of the FRL after PVE was 37.9 {+-} 0.1 %. In 70 patients (3.9 %), surgery was not performed because of failure of PVE (clinical success rate 96.1 %). In 51 patients (2.8 %), the hypertrophy response was insufficient to perform liver resection. In the other 17 cases, 12 did not technically succeed (0.7 %) and 7 caused a complication leading to unresectability (0.4 %). In 6.1 %, resection was cancelled because of local tumor progression after PVE. Major complications were seen in 2.5 %, and the mortality rate was 0.1 %. A head-to-head comparison shows a negative effect of liver cirrhosis on hypertrophy response. The use of n-butyl cyanoacrylate seems to have a greater effect on hypertrophy, but the difference with other embolization materials did not reach statistical significance. No difference in regeneration is seen in patients with cholestasis or chemotherapy. Preoperative PVE has a high technical and clinical success rate. Liver cirrhosis has a negative effect on regeneration, but cholestasis and chemotherapy do not seem to have an influence on the hypertrophy response. The use of n-butyl cyanoacrylate may result in a greater hypertrophy response compared with other embolization materials used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatic Tract Plug-Embolisation After Biliary Stenting. Is It Worthwhile?

PurposePTC and stenting procedures are associated with significant risks including life-threatening haemorrhage, sepsis, renal failure and high mortality rates. PTC tract closure methods are utilised to reduce haemorrhagic complications despite little evidence to support their use. The current study assesses the incidence of haemorrhagic complications following PTC and stenting procedures, both prior to and following the introduction of a dedicated expanding gelatin foam-targeted embolisation liver tract closure technique.Materials and MethodsHaemorrhagic complications were retrospectively identified in patients undergoing PTC procedures both prior to (subgroup 1) and following (subgroup 2) the introduction of a dedicated targeted liver tract closure method between 9/11/2010 and 10/08/2012 in a single tertiary referral centre. Mean blood Hb decrease following PTC was established in subgroups 1 and 2. Kaplan–Meier life-table analysis was performed to compare survival outcomes between subgroups using the log-rank test.ResultsHaemorrhagic complications were significantly reduced following the introduction of the targeted PTC tract closure method [(12 vs. 3 % of subgroups 1 (n = 101) and 2 (n = 92), respectively (p = 0.027)]. Mean blood Hb decrease following PTC was 1.40 versus 0.68 g/dL in subgroups 1 and 2, respectively (p = 0.069). 30-day mortality was 14 and 12 % in subgroups 1 and 2, respectively. 50 % of the entire cohort had died by 174 days post-PTC.ConclusionIntroduction of liver tract embolisation significantly reduced haemorrhagic complications in our patient cohort. Utilisation of this method has the potential to reduce the morbidity and mortality burden associated with post-PTC haemorrhage by preventing bleeding from the liver access tract.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Appropriateness of Renal Angioplasty. The ANPARIA Software: A Multidisciplinary Expert Panel Approach

Percutaneous transluminal renal angioplasty (PTRA) is an invasive technique that is costly and involves the risk of complications and renal failure. The ability of PTRA to reduce the administration of antihypertensive drugs has been demonstrated. A potentially greater benefit, which nevertheless remains to be proven, is the deferral of the need for chronic dialysis. The aim of the study (ANPARIA) was to assess the appropriateness of PTRA to impact on the evolution of renal function. A standardized expert panel method was used to assess the appropriateness of medical treatment alone or medical treatment with revascularization in various clinical situations. The choice of revascularization by either PTRA or surgery was examined for each clinical situation. Analysis was based on a detailed literature review and on systematically elicited expert opinion, which were obtained during a two-round modified Delphi process. The study provides detailed responses on the appropriateness of PTRA for 1848 distinct clinical scenarios. Depending on the major clinical presentation, appropriateness of revascularization varied from 32% to 75% for individual scenarios (overal 48%). Uncertainty as to revascularization was 41% overall. When revascularization was appropriate, PTRA was favored over surgery in 94% of the scenarios, except in certain cases of aortic atheroma where sugery was the preferred choice. Kidney size >7 cm, absence of coexisting disease, acute renal failure, a high degree of stenosis ({>=}70%), and absence of multiple arteries were identified as predictive variables of favorable appropriateness ratings. Situations such as cardiac failure with pulmonary edema or acute thrombosis of the renal artery were defined as indications for PTRA. This study identified clinical situations in which PTRA or surgery are appropriate for renal artery disease. We built a decision tree which can be used via Internet: the ANPARIA software (http://www.chu-clermontferrand.fr/anpariahttp://www.chu-clermontferrand.fr/anparia/). In numerous clinical situations uncertainty remains as to whether PTRA prevents deterioration of renal function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alternative Treatment for Bleeding Peristomal Varices: Percutaneous Parastomal Embolization

Purpose: To describe how peristomal varices can be successfully embolized via a percutaneous parastomal approach. Methods: The medical records of patients who underwent this procedure between December 1, 2000, and May 31, 2008, were retrospectively reviewed. Procedural details were recorded. Median fluoroscopy time and bleeding-free interval were calculated. Results: Seven patients underwent eight parastomal embolizations. The technical success rate was 88 % (one failure). All embolizations were performed with coils combined with a sclerosant, another embolizing agent, or both. Of the seven successful parastomal embolizations, there were three cases of recurrent bleeding; the median time to rebleeding was 45 days (range 26-313 days). The remaining four patients did not develop recurrent bleeding during the follow-up period; their median bleeding-free interval was 131 days (range 40-659 days). Conclusion: This case review demonstrated that percutaneous parastomal embolization is a feasible technique to treat bleeding peristomal varices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coupled geomechanical investigation of depletion-induced fault reactivation

Fault reactivation during subsurface fluid production pose significant challenges to safe and sustainable resource extraction. Here, this study presents a three-dimensional coupled geomechanical framework to investigate the processes driving fault reactivation, capturing the interactions between reservoir dynamics and geomechanical responses. Verification against theoretical estimations based on linear poroelasticity confirms the model's capacity in representing reservoir background stress responses. However, the study reveals that relying solely on background stress states can underestimate or overestimate fault reactivation potential, emphasizing the importance of including localized stress perturbations such as differential compaction and stress redistribution. Applied to a fault (M1) inspired by the geological characteristics of the Groningen field, the model shows slip initiation at 2965 m depth with 16.0 MPa depletion, aligning with field observations where seismicity occurred at approximately 3 km depth after 15.8 MPa depletion. Parametric studies reveal: (1) inelastic reservoir compaction delays fault reactivation and mitigates fault slip by reducing stress concentration, (2) higher intermediate in-situ stress magnitudes decrease the Coulomb Failure Stress (CFS) increase rate and reduce fault slip, (3) larger fault offsets amplify shear stress near the offset zone, promoting earlier reactivation and longer rupture propagation, and (4) fault permeability significantly influences pressure diffusion, with low-permeability faults leading to sharper stress changes and earlier fault destabilization. These insights highlight the critical role of geological and mechanical parameters in fault reactivation and provide a predictive framework for mitigating induced seismicity risks.

Coupled geomechanical modeling↗

High-Dose, Single-Fraction Image-Guided Intensity-Modulated Radiotherapy for Metastatic Spinal Lesions

Purpose: To report tumor control and toxicity for patients treated with image-guided intensity-modulated radiotherapy (RT) for spinal metastases with high-dose single-fraction RT. Methods and Materials: A total of 103 consecutive spinal metastases in 93 patients without high-grade epidural spinal cord compression were treated with image-guided intensity-modulated RT to doses of 18-24 Gy (median, 24 Gy) in a single fraction between 2003 and 2006. The spinal cord dose was limited to a 14-Gy maximal dose. The patients were prospectively examined every 3-4 months with clinical assessment and cross-sectional imaging. Results: The overall actuarial local control rate was 90% (local failure developed in 7 patients) at a median follow-up of 15 months (range, 2-45 months). The median time to local failure was 9 months (range, 2-15 months) from the time of treatment. Of the 93 patients, 37 died. The median overall survival was 15 months. In all cases, death was from progression of systemic disease and not local failure. The histologic type was not a statistically significant predictor of survival or local control. The radiation dose was a significant predictor of local control (p = 0.03). All patients without local failure also reported durable symptom palliation. Acute toxicity was mild (Grade 1-2). No case of radiculopathy or myelopathy has developed. Conclusion: High-dose, single-fraction image-guided intensity-modulated RT is a noninvasive intervention that appears to be safe and very effective palliation for patients with spinal metastases, with minimal negative effects on quality of life and a high probability of tumor control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Chemoradiation for Rectal Cancer Using Capecitabine and Celecoxib Correlated With Posttreatment Assessment of Thymidylate Synthase and Thymidine Phosphorylase Expression

Purpose: Thymidylate synthase (TS) and thymidine phosphorylase (TP) expression have been shown to be predictors of response to therapy. The toxicity, efficacy, surgical morbidity, and immunohistochemical TS and TP expression were assessed in surgical resection specimens after preoperative chemoradiation. Methods and Materials: Twenty patients with clinical stage I to III rectal adenocarcinoma received preoperative chemoradiation and underwent surgical resection 6 weeks later. Results: Posttreatment tumor stages were T1 to T2 and N0 in 30% of patients; T3 to T4 and N0 in 30% of patients; and T1 to T3 and N1 to N2 in 15% of patients. Pathologic complete response (pCR) was evident in 25% and tumor regression occurred in a total of 80% of patients. Anal sphincter-sparing surgery was performed in 80% of cases. Acute and perioperative complications were minimal, with no grade 3/4 toxicity or treatment breaks. Pelvic control was obtained in 90% of patients. With a median follow-up of 65.5 months (range, 8-80 months), the 6-year actuarial survival rate was 75%. Local failure was significantly associated with nonresponse to therapy and with high TS and low TP expression (p = 0.008 and p = 0.04, respectively). Conclusions: The combination of capecitabine, celecoxib, and x-radiation therapy yields excellent response: a 25% pathologic pCR, no acute grade 3/4 toxicity, and minimal surgical morbidity. Nonresponders expressed significantly increased TS levels and decreased TP levels in posttreatment resection specimens compared to responders.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unilateral Radiotherapy for the Treatment of Tonsil Cancer

Purpose: To assess, through a retrospective review, clinical outcomes of patients with squamous cell carcinoma of the tonsil treated at the M. D. Anderson Cancer Center with unilateral radiotherapy techniques that irradiate the involved tonsil region and ipsilateral neck only. Methods and Materials: Of 901 patients with newly diagnosed squamous cell carcinoma of the tonsil treated with radiotherapy at our institution, we identified 102 that were treated using unilateral radiotherapy techniques. All patients had their primary site of disease restricted to the tonsillar fossa or anterior pillar, with <1 cm involvement of the soft palate. Patients had TX (n = 17 patients), T1 (n = 52), or T2 (n = 33) disease, with Nx (n = 3), N0 (n = 33), N1 (n = 23), N2a (n = 21), or N2b (n = 22) neck disease. Results: Sixty-one patients (60%) underwent diagnostic tonsillectomy before radiotherapy. Twenty-seven patients (26%) underwent excision of a cervical lymph node or neck dissection before radiotherapy. Median follow-up for surviving patients was 38 months. Locoregional control at the primary site and ipsilateral neck was 100%. Two patients experienced contralateral nodal recurrence (2%). The 5-year overall survival and disease-free survival rates were 95% and 96%, respectively. The 5-year freedom from contralateral nodal recurrence rate was 96%. Nine patients required feeding tubes during therapy. Of the 2 patients with contralateral recurrence, 1 experienced an isolated neck recurrence and was salvaged with contralateral neck dissection only and remains alive and free of disease. The other patient presented with a contralateral base of tongue tumor and involved cervical lymph node, which may have represented a second primary tumor, and died of disease. Conclusions: Unilateral radiotherapy for patients with TX-T2, N0-N2b primary tonsil carcinoma results in high rates of disease control, with low rates of contralateral nodal failure and a low incidence of acute toxicity requiring gastrostomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Dose–Response Analysis of Biochemical Control Outcomes After {sup 125}I Monotherapy for Patients With Favorable-Risk Prostate Cancer

Purpose: To define the optimal dose for {sup 125}I prostate implants by correlating postimplantation dosimetry findings with biochemical failure and toxicity. Methods and Materials: Between 2003 and 2009, 683 patients with prostate cancer were treated with {sup 125}I prostate brachytherapy without supplemental external beam radiation therapy and were followed up for a median time of 80 months. Implant dose was defined as the D90 (the minimal dose received by 90% of the prostate) on postoperative day 1 and 1 month after implantation. Therefore, 2 dosimetric variables (day 1 D90 and day 30 D90) were analyzed for each patient. We investigated the dose effects on biochemical control and toxicity. Results: The 7-year biochemical failure-free survival (BFFS) rate for the group overall was 96.4% according to the Phoenix definition. A multivariate analysis found day 1 D90 and day 30 D90 to be the most significant factors affecting BFFS. The cutoff points for day 1 D90 and day 30 D90, calculated from ROC curves, were 163 Gy and 175 Gy, respectively. By use of univariate analysis, various dosimetric cutoff points for day 30 D90 were tested. We found that day 30 D90 cutoff points from 130 to 180 Gy appeared to be good for the entire cohort. Greater D90s were associated with an increase in late genitourinary or gastrointestinal toxicity ≥ grade 2, but the increase was not statistically significant. Conclusions: Improvements in BFFS rates were seen with increasing D90 levels. Day 30 D90 doses of 130 to 180 Gy were found to serve as cutoff levels. For low-risk and low-tier intermediate-risk prostate cancer patients, high prostate D90s, even with doses exceeding 180 Gy, achieve better treatment results and are feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monitoring of Wind Turbine Gearbox Condition through Oil and Wear Debris Analysis: A Full-Scale Testing Perspective

Despite the wind industry's dramatic development during the past decade, it is still challenged by premature turbine subsystem/component failures, especially for turbines rated above 1 MW. Because a crane is needed for each replacement, gearboxes have been a focal point for improvement in reliability and availability. Condition monitoring (CM) is a technique that can help improve these factors, leading to reduced turbine operation and maintenance costs and, subsequently, lower cost of energy for wind power. Although technical benefits of CM for the wind industry are normally recognized, there is a lack of published information on the advantages and limitations of each CM technique confirmed by objective data from full-scale tests. This article presents first-hand oil and wear debris analysis results obtained through tests that were based on full-scale wind turbine gearboxes rated at 750 kW. The tests were conducted at the 2.5-MW dynamometer test facility at the National Wind Technology Center at the National Renewable Energy Laboratory. The gearboxes were tested in three conditions: run-in, healthy, and damaged. The investigated CM techniques include real-time oil condition and wear debris monitoring, both inline and online sensors, and offline oil sample and wear debris analysis, both onsite and offsite laboratories. The reported results and observations help increase wind industry awareness of the benefits and limitations of oil and debris analysis technologies and highlight the challenges in these technologies and other tribological fields for the Society of Tribologists and Lubrication Engineers and other organizations to help address, leading to extended gearbox service life.

17 WIND ENERGY↗

Positive- and negative-frequency noise from an ensemble of two-level fluctuators

The analysis of charge noise based on the Bloch-Redfield treatment of an ensemble of dissipative two-level fluctuators generally results in a violation of the fluctuation-dissipation theorem. The standard Markov approximation (when applied to the two-level fluctuators coupled to a bath) can be identified as the main origin of this failure. The resulting decoherence rates only involve the bath response at the fluctuator frequency, and thus completely neglect the effects of frequency broadening. A systematic and computationally convenient way to overcome this issue is to employ the spectator-qubit method: by coupling an auxiliary qubit to the two-level fluctuator ensemble, an analytical approximation for S(ω) fully consistent with the fluctuation-dissipation theorem can be obtained. We discuss the resulting characteristics of the noise which exhibits distinct behavior over several frequency ranges, including a 1/f to 1/f2 crossover with a T3 temperature dependence of the crossover frequency.

2-dimensional systems↗

An Investigation of Potential Intermittency Induced Outage Modes for Wind Generation

In a deterministic contingency analysis (DCA), renewable generation such as wind is modeled similar to a conventional generator. In the current practices of a probabilistic contingency analysis (PCA), the outage parameters for a renewable generator reflect only failures of its parts. Intermittency due to wind speed changes or cloud cover may cause renewable generation to ramp up or down within a short time period and, after the transient is finished, stay at a certain generation level before a new ramp starts. A fast ramp-down transient can last for some time and thus, have an effect similar to a failure or de-rated generation of a conventional generator. This paper investigates potential outage modes that are induced by the intermittency of renewable generation, as well as the modeling and parameterization of such outage modes in the PCA framework. Historical time-series wind generation data are used in this study to extract different types of transients and perform statistical analyses to obtain input data such that the intermittency induced outages (IIOs) can be included in PCA.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Indoor Occupancy Sensing via Networked Nodes (2012–2022): A Review

In the past decade, different sensing mechanisms and algorithms have been developed to detect or estimate indoor occupancy. One of the most recent advancements is using networked sensor nodes to create a more comprehensive occupancy detection system where multiple sensors can identify human presence within more expansive areas while delivering enhanced accuracy compared to a system that relies on stand-alone sensor nodes. The present work reviews the studies from 2012 to 2022 that use networked sensor nodes to detect indoor occupancy, focusing on PIR-based sensors. Methods are compared based on pivotal ADPs that play a significant role in selecting an occupancy detection system for applications such as Health and Safety or occupant comfort. These parameters include accuracy, information requirement, maximum sensor failure and minimum observation rate, and feasible detection area. We briefly describe the overview of occupancy detection criteria used by each study and introduce a metric called “sensor node deployment density” through our analysis. This metric captures the strength of network-level data filtering and fusion algorithms found in the literature. It is hinged on the fact that a robust occupancy estimation algorithm requires a minimal number of nodes to estimate occupancy. This review only focuses on the occupancy estimation models for networked sensor nodes. It thus provides a standardized insight into networked nodes’ occupancy sensing pipelines, which employ data fusion strategies, network-level machine learning algorithms, and occupancy estimation algorithms. This review thus helps determine the suitability of the reviewed methods to a standard set of application areas by analyzing their gaps.

Emad-Ud-Din, Muhammad (ORCID:0000000279515538)↗

Prediction of gas leakage of environmental control systems

Mathematical models of leakage configurations and various flow theories are presented with the substantive experimental test data to provide background material for future design and failure analysis. Normal-rate leakage and emergency, high-rate leakage are considered.

Jackson, J. K.↗

JANTX1N5615 switching diode

Diodes manufactured by Semtech and Micro Semiconductor were tested. Both sample lots exceeded 50% fail-rate in all groups. Failure analysis was performed for groups 2 and 3.

Source record↗

Corrosion of graphite composites in phosphoric acid fuel cells

Polymers, polymer-graphite composites and different carbon materials are being considered for many of the fuel cell stack components. Exposure to concentrated phosphoric acid in the fuel cell environment and to high anodic potential results in corrosion. Relative corrosion rates of these materials, failure modes, plausible mechanisms of corrosion and methods for improvement of these materials are investigated.

Christner, L. G.↗