Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Gamma-ray Output Spectra from 239 Pu Fission

Gamma-ray multiplicities, individual gamma-ray energy spectra, and total gamma energy spectra following neutron-induced fission of 239Pu were measured using the DANCE detector at Los Alamos. Corrections for detector response were made using a forward-modeling technique based on propagating sets of gamma rays generated from a paramaterized model through a GEANT model of the DANCE array and adjusting the parameters for best fit to the measured spectra. The results for the gamma-ray spectrum and multiplicity are in general agreement with previous results, but the measured total gamma-ray energy is about 10% higher. A dependence of the gamma-ray spectrum on the gamma-ray multplicity was also observed. Global model calculations of the multiplicity and gamma energy distributions are in good agreement with the data, but predict a slightly softer total-energy distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward an Experimentally Determined {sup 26m}Al(p,{gamma}){sup 27}Si Reaction Rate in ONe Novae

Evidence of the ongoing nucleosynthesis of {sup 26}Al in our galaxy has been found in presolar grains and in observations of the 1.809-MeV {gamma} ray, which results from the {beta} decay of the ground state of {sup 26}Al({sup 26g}Al; t{sub 1/2} = 7.2x 10{sup 5} yrs) to an excited state in {sup 26}Mg. The nucleosynthesis of {sup 26}Al is complicated by the existence of the isomeric state, {sup 26m}Al, at 228 keV (t{sub 1/2} = 6.3 s), which must be treated independently from {sup 26g}Al in certain stellar environments, such as ONe novae, where temperatures are below 0.4 GK [1]. {sup 26m}Al{beta} decays directly to {sup 26g}Mg, bypassing the emission of the 1.809-MeV {gamma} ray. The {sup 26g}Al(p,{gamma}){sup 27}Si and {sup 26m}Al(p,{gamma}){sup 27}Si reactions destroy {sup 26}Al in novae and have a direct impact on the net amount of {sup 26}Al produced. While the {sup 26g}Al(p,{gamma}){sup 27}Si reaction rate has been studied extensively, there has been virtually no information published on resonances of the {sup 26m}Al(p,{gamma}){sup 27}Si reaction and previously published reaction rates [2] have been based on {sup 26g}Al+p resonances and Hauser-Feshbach calculations. The {sup 27}Al({sup 3}He,t){sup 27}Si*(p){sup 26}Al and {sup 28}Si({sup 3}He,{alpha}){sup 27}Si*(p){sup 26}Al reactions have been studied at the Wright Nuclear Structure Laboratory at Yale University. Proton decays from the excited states in {sup 27}Si populated via the {sup 27}Al({sup 3}He,t){sup 27}Si and {sup 28}Si({sup 3}He,{alpha}){sup 27}Si transfer reactions were detected in coincidence with the reaction products of interest, which were detected at the focal plane of the Yale Enge spectrograph. Angular correlations were measured to constrain spins and determine proton branching ratios for {sup 26m}Al+p resonances with E{sub cm}>450 keV and excitation energies of {sup 27}Si were measured. Using this information a {sup 26m}Al(p,{gamma}){sup 27}Si reaction rate based on experimental information has been calculated for the first time. The extreme differences in proton decays from excited states in {sup 27}Si to {sup 26g}Al and {sup 26m}Al show that {sup 26m}Al(p,{gamma}){sup 27}Si reaction rates found using experimental data for {sup 26g}Al+p resonances are not valid, and a direct {sup 26m}Al(p,{gamma}){sup 27}Si measurement must be made to reliably determine the strengths of low-energy resonances, which most likely dominate the reaction rate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural and Biochemical Basis for the Binding Selectivity of Peroxisome Proliferator-activated Receptor [gamma] to PGC-1[alpha]

The functional interaction between the peroxisome proliferator-activated receptor {gamma} (PPAR{gamma}) and its coactivator PGC-1{alpha} is crucial for the normal physiology of PPAR{gamma} and its pharmacological response to antidiabetic treatment with rosiglitazone. Here we report the crystal structure of the PPAR{gamma} ligand-binding domain bound to rosiglitazone and to a large PGC-1{alpha} fragment that contains two LXXLL-related motifs. The structure reveals critical contacts mediated through the first LXXLL motif of PGC-1{alpha} and the PPAR{gamma} coactivator binding site. Through a combination of biochemical and structural studies, we demonstrate that the first LXXLL motif is the most potent among all nuclear receptor coactivator motifs tested, and only this motif of the two LXXLL-related motifs in PGC-1{alpha} is capable of binding to PPAR{gamma}. Our studies reveal that the strong interaction of PGC-1{alpha} and PPAR{gamma} is mediated through both hydrophobic and specific polar interactions. Mutations within the context of the full-length PGC-1{alpha} indicate that the first PGC-1{alpha} motif is necessary and sufficient for PGC-1{alpha} to coactivate PPAR{gamma} in the presence or absence of rosiglitazone. These results provide a molecular basis for specific recruitment and functional interplay between PPAR{gamma} and PGC-1{alpha} in glucose homeostasis and adipocyte differentiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structural basis for distinctive recognition of fibrinogen [gamma]C peptide by the platelet integrin [alpha][subscript IIb][beta]3

Hemostasis and thrombosis (blood clotting) involve fibrinogen binding to integrin {alpha}{sub IIb}{beta}{sub 3} on platelets, resulting in platelet aggregation. {alpha}{sub v}{beta}{sub 3} binding fibrinogen via an Arg-Asp-Gly (RGD) motif in fibrinogen's {alpha} subunit. {alpha}{sub IIb}{beta}{sub 3} also binds to fibrinogen; however, it does so via an unstructured RGD-lacking C-terminal region of the {gamma} subunit ({gamma}C peptide). These distinct modes of fibrinogen binding enable {alpha}{sub IIb}{beta}{sub 3} and {alpha}{sub v}{beta}{sub 3} to function cooperatively in hemostasis. In this study, crystal structures reveal the integrin {alpha}{sub IIb}{beta}{sub 3}-{gamma}C peptide interface, and, for comparison, integrin {alpha}{sub IIb}{beta}{sub 3} bound to a lamprey {gamma}C primordial RGD motif. Compared with RGD, the GAKQAGDV motif in {gamma}C adopts a different backbone configuration and binds over a more extended region. The integrin metal ion-dependent adhesion site (MIDAS) Mg{sup 2+} ion binds the {gamma}C Asp side chain. The adjacent to MIDAS (ADMIDAS) Ca{sup 2+} ion binds the {gamma}C C terminus, revealing a contribution for ADMIDAS in ligand binding. Structural data from this natively disordered {gamma}C peptide enhances our understanding of the involvement of {gamma}C peptide and integrin {alpha}{sub IIb}{beta}{sub 3} in hemostasis and thrombosis.

59 BASIC BIOLOGICAL SCIENCES↗

Numerical methods and hypoexponential approximations for gamma distributed delay differential equations

Abstract Gamma distributed delay differential equations (DDEs) arise naturally in many modelling applications. However, appropriate numerical methods for generic gamma distributed DDEs have not previously been implemented. Modellers have therefore resorted to approximating the gamma distribution with an Erlang distribution and using the linear chain technique to derive an equivalent system of ordinary differential equations (ODEs). In this work, we address the lack of appropriate numerical tools for gamma distributed DDEs in two ways. First, we develop a functional continuous Runge–Kutta (FCRK) method to numerically integrate the gamma distributed DDE without resorting to Erlang approximation. We prove the fourth-order convergence of the FCRK method and perform numerical tests to demonstrate the accuracy of the new numerical method. Nevertheless, FCRK methods for infinite delay DDEs are not widely available in existing scientific software packages. As an alternative approach to solving gamma distributed DDEs, we also derive a hypoexponential approximation of the gamma distributed DDE. This hypoexponential approach is a more accurate approximation of the true gamma distributed DDE than the common Erlang approximation but, like the Erlang approximation, can be formulated as a system of ODEs and solved numerically using standard ODE software. Using our FCRK method to provide reference solutions, we show that the common Erlang approximation may produce solutions that are qualitatively different from the underlying gamma distributed DDE. However, the proposed hypoexponential approximations do not have this limitation. Finally, we apply our hypoexponential approximations to perform statistical inference on synthetic epidemiological data to illustrate the utility of the hypoexponential approximation.

97 MATHEMATICS AND COMPUTING↗

Effective Lagrangian approach to fermion electric dipole moments induced by a CP-violating WW{gamma} vertex

The one-loop contribution of the two CP-violating components of the WW{gamma} vertex, {kappa}-tilde{sub {gamma}}W{sub {mu}}{sup +}W{sub {nu}}{sup -}F-tilde{sup {mu}}{sup {nu}} and ({lambda}-tilde{sub {gamma}}/m{sub W}{sup 2})W{sub {mu}}{sub {nu}}{sup +}W{sub {rho}}{sup -{nu}}F-tilde{sup {rho}}{sup {mu}}, on the electric dipole moment (EDM) of fermions is calculated using dimensional regularization and its impact at low energies reexamined in the light of the decoupling theorem. The Ward identities satisfied by these couplings are derived by adopting a SU{sub L}(2)xU{sub Y}(1)-invariant approach and their implications in radiative corrections discussed. Previous results on {kappa}-tilde{sub {gamma}}, whose bound is updated to |{kappa}-tilde{sub {gamma}}|<5.2x10{sup -5}, are reproduced, but disagreement with those existing for {lambda}-tilde{sub {gamma}} is found. In particular, the upper bound |{lambda}-tilde{sub {gamma}}|<1.9x10{sup -2} is found from the limit on the neutron EDM, which is more than 2 orders of magnitude less stringent than that of previous results. It is argued that this difference between the {kappa}-tilde{sub {gamma}} and {lambda}-tilde{sub {gamma}} bounds is the one that might be expected in accordance with the decoupling theorem. This argument is reinforced by analyzing carefully the low-energy behavior of the loop functions. The upper bounds on the W EDM, |d{sub W}|<6.2x10{sup -21} e{center_dot}cm, and the magnetic quadrupole moment, |Q-tilde{sub W}|<3x10{sup -36} e{center_dot}cm{sup 2}, are derived. The EDM of the second and third families of quarks and charged leptons are estimated. In particular, EDM as large as 10{sup -20} e{center_dot}cm and 10{sup -21} e{center_dot}cm are found for the t and b quarks, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searching the inclusive l{gamma}Ee{sub T}+b-quark signature for radiative top quark decay and non-standard-model processes

We compare the inclusive production of events containing a lepton (l), a photon ({gamma}), significant transverse momentum imbalance (Ee{sub T}), and a jet identified as containing a b-quark, to SM predictions. The search uses data produced in proton-antiproton collisions at {radical}(s)=1.96 TeV corresponding to 1.9 fb{sup -1} of integrated luminosity taken with the CDF detector. We find 28 l{gamma}bEe{sub T} events versus an expectation of 31.0{sub -3.5}{sup +4.1} events. If we further require events to contain at least three jets and large total transverse energy, the largest SM source is radiative top-quark pair production, tt+{gamma}. In the data we observe 16 tt{gamma} candidate events versus an expectation from SM sources of 11.2{sub -2.1}{sup +2.3}. Assuming the difference between the observed number and the predicted non-top-quark total of 6.8{sub -2.0}{sup +2.2} is due to SM top-quark production, we estimate the tt{gamma} cross section to be 0.15{+-}0.08 pb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the Gamma Knife using a new phantom following the AAPM TG51 and TG21 protocols

Purpose: To compare calibration of the Leksell Gamma Knife according to the American Association of Physicists in Medicine Task Groups 21 and 51 protocols. A new phantom was fabricated for this purpose. Its design, physical properties, and composition are described. Materials and methods: The Gamma Knife TG-51 calibration phantom is designed to be filled with water and support an ionization chamber positioned at its center. The phantom is thimble-shaped, with a 2 mm plastic wall to contain water. The phantom and chamber assembly was mounted in a LeksellTM stereotactic frame. The location of the chamber's sensitive volume was determined using computed tomography. The chamber-phantom assembly was attached to the 18 mm helmet in the Gamma Knife by the stereotactic frame. The phantom's geometry allowed radiation beams from each of the 201 Gamma Knife cobalt-60 sources to converge after an 8 cm path to the ionization chamber's sensitive volume. This is similar to the arrangement by which one calibrates the Gamma Knife using the manufacturer-supplied polystyrene phantom. Results: The phantom was attached to the Gamma Knife so that the ionization chamber was reproducibly positioned at the convergence of the radiation beams. Because of the phantom's design, the phantom could be affixed to either trunnions or the automatic patient positioning system, once mounted in the LeksellTM stereotectic frame. Comparisons using different phantoms and protocols resulted in the following calibration ratios for TG-21 in the polystyrene sphere phantom, TG-21 in the water phantom, and TG-51 in the water phantom, respectively: 1.000, 1.008, 0.986, when corrected for transmission through the plastic water reservoir wall and using the same ionization chamber. Transmission measurements using a 1 cm thickness of the same material in the Co-60 beam determined that the phantom's 2 mm plastic wall resulted in a reduction in the measured the output by 0.5%. Conclusions: Calibration of the Gamma Knife can be performed in liquid water using the AAPM TG-51 protocol and this new phantom, thereby eliminating uncertainties with respect to the composition of the manufacturer's phantom. Perturbation of calibration measurements by nonwater materials was characterized and could be corrected. Calibration values for the Gamma Knife that were obtained using the three methods for our phantoms agree to within 1.4%. TG21 and TG51 calibration of the Gamma Knife using the water phantom agreed to within 2.2%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric interpretation of the {gamma} dose distribution comparison technique: Interpolation-free calculation

The {gamma} dose comparison tool has been used by numerous investigators to quantitatively compare multidimensional dose distributions. The {gamma} tool requires the specification of dose and distance-to-agreement (DTA) criteria for acceptable variations between the dose distributions. The tool then provides a comparison that simultaneously evaluates the dose difference and distance to agreement of the two dose distributions. One of the weaknesses of the tool is that the comparison requires one of the dose distributions to have a relatively high spatial resolution, with points spaced significantly closer than the DTA criterion. The determination of {gamma} involves an exhaustive search process, so the computation time is significant if an accurate {gamma} is desired. The reason for the need for high spatial resolution lies with the fact that the {gamma} tool measures the closest point in one of the dose distributions (the evaluated distribution) with individual points of the other distribution (the reference distribution) when the two distributions are normalized by the dose difference and DTA criteria for the dose and spatial coordinates, respectively. The closest point in the evaluated distribution to a selected reference distribution point is the value of {gamma} at that reference point. If individual evaluated dose distribution points are compared, the closest point may not accurately reflect the closest value of the evaluated distribution as if it were interpolated on an infinite resolution grid. Therefore, a reinterpretation of the {gamma} distribution as the closest geometric distance between the two distributions is proposed. This is conducted by subdividing the evaluated distribution into simplexes; line segments, triangles, and tetrahedra for one, two, and three-dimensional (3D) dose distributions. The closest distance between any point and these simplexes can be straightforwardly computed using matrix multiplication and inversion without the need of interpolating the original evaluated distribution. While an exhaustive search is still required, not having to interpolate the evaluated distribution avoids the drastic growth of calculation time incurred by interpolation and makes the {gamma} tool more practical and more accurate. In our experiment, the geometric method accurately computes {gamma} distributions between 3D dose distributions on a 200x200x50 grid within two minutes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-535: Preliminary 2D and 3D Gamma Calculation Comparison Using PRESAGE

Purpose: To compare gamma calculations from 2D and 3D dosimetry measurements for phantom quality assurance. Methods: An IROC Houston (RPC) head and neck phantom was irradiated with a 9 beam IMRT plan using two inserts: a TLD and film insert and a PRESAGE insert. Both inserts were irradiated 3 times. The film and PRESAGE doses were scaled to the TLD dose and 2D gamma calculations were made in the axial and sagittal planes bisecting the primary target. 3D gamma measurements were taken within the PRESAGE dosimeter volume. Gamma constraints of 3%/3mm distance to agreement (DTA), 5%/3mm DTA and 7%/4mm DTA were used in the study. The 3 irradiations for each insert were averaged together for comparison. Results: Film measurements for the 2D gamma showed 85% pixels passing at 3%/3mm in both planes. The 5%/3 mm constraint had 93% and 90% passing in the two planes. The 7%/4mm restraint resulted in 99% passing in both planes. The PRESAGE 2D gamma passed 66% and 61% of pixels in the both planes at 3%/3mm. At 5%/3mm 86% and 82% passed. For 7%/4mm, 94% of pixels passed in both planes. The 3D gamma resulted in a pass rate of 90% at 3%/3mm, 95% at 5%/3mm, and 99% at 7%/4mm. Conclusion: 2D gamma pass rates using film showed a higher pass rate than PRESAGE using the same criteria in the same planes. This may be due to poor 3D registration with the treatment plan compared to the 2D film registration system. The 3D gamma results had a higher pass rate (> 90% pass rate) possibly because it sampled many more pixels in noncritical volumes thus diluting the percent of pixels passing. 3D restraints should be more restrictive to be comparable to 2D results. Funding from NIH grant 5R01CA100835.

60 APPLIED LIFE SCIENCES↗

TU-C-BRE-08: IMRT QA: Selecting Meaningful Gamma Criteria Based On Error Detection Sensitivity

Purpose: To develop a strategy for defining meaningful tolerance limits and studying the sensitivity of IMRT QA gamma criteria by inducing known errors in QA plans. Methods: IMRT QA measurements (ArcCHECK, Sun Nuclear) were compared to QA plan calculations with induced errors. Many (>24) gamma comparisons between data and calculations were performed for each of several kinds of cases and classes of induced error types with varying magnitudes (e.g. MU errors ranging from -10% to +10%), resulting in over 3,000 comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using various gamma criteria. Results: This study demonstrates that random, case-specific, and systematic errors can be detected by the error curve analysis. Depending on location of the peak of the error curve (e.g., not centered about zero), 3%/3mm threshold=10% criteria may miss MU errors of up to 10% and random MLC errors of up to 5 mm. Additionally, using larger dose thresholds for specific devices may increase error sensitivity (for the same X%/Ymm criteria) by up to a factor of two. This analysis will allow clinics to select more meaningful gamma criteria based on QA device, treatment techniques, and acceptable error tolerances. Conclusion: We propose a strategy for selecting gamma parameters based on the sensitivity of gamma criteria and individual QA devices to induced calculation errors in QA plans. Our data suggest large errors may be missed using conventional gamma criteria and that using stricter criteria with an increased dose threshold may reduce the range of missed errors. This approach allows quantification of gamma criteria sensitivity and is straightforward to apply to other combinations of devices and treatment techniques.

60 APPLIED LIFE SCIENCES↗

SU-F-T-236: Comparison of Two IMRT/VMAT QA Systems Using Gamma Index Analysis

Purpose: The goal of this study is to assess differences in the Gamma index pass rates when using two commercial QA systems and provide optimum Gamma index parameters for pre-treatment patient specific QA. Methods: Twenty-two VMAT cases that consisted of prostate, lung, head and neck, spine, brain and pancreas, were included in this study. The verification plans have been calculated using AcurosXB(V11) algorithm for different dose grids (1.5mm, 2.5mm, 3mm). The measurements were performed on TrueBeam(Varian) accelerator using both EPID(S1000) portal imager and ArcCheck(SunNuclearCorp) devices. Gamma index criteria variation of 3%/3mm, 2%/3mm, 2%/2mm and threshold (TH) doses of 5% to 50% were used in analysis. Results: The differences in Gamma pass rates between two devices are not statistically significant for 3%/3mm, yielding pass rate higher than 95%. Increase of lower dose TH showed reduced pass rates for both devices. ArcCheck’s more pronounced effect can be attributed to higher contribution of lower dose region spread. As expected, tightening criteria to 2%/2mm (TH: 10%) decreased Gamma pass rates below 95%. Higher EPID (92%) pass rates compared to ArcCheck (86%) probably due to better spatial resolution. Portal Dosimetry results showed lower Gamma pass rates for composite plans compared to individual field pass rates. This may be due to the expansion in the analyzed region which includes pixels not included in the separate field analysis. Decreasing dose grid size from 2.5mm to 1.5mm did not show statistically significant (p<0.05) differences in Gamma pass rates for both QA devices. Conclusion: Overall, both system measurements agree well with calculated dose when using gamma index criteria of 3%/3mm for a variety of VMAT cases. Variability between two systems increases using different dose GRID, TH and tighter gamma criteria and must be carefully assessed prior to clinical use.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-06: Improving the Performance of Gamma Analysis QA with Radiomics- Based Image Analysis

Purpose: The use of gamma analysis for IMRT quality assurance has well-known limitations. Traditionally, a simple thresholding technique is used to evaluated passing criteria. However, like any image the gamma distribution is rich in information which thresholding mostly discards. We therefore propose a novel method of analyzing gamma images that uses quantitative image features borrowed from radiomics, with the goal of improving error detection. Methods: 368 gamma images were generated from 184 clinical IMRT beams. For each beam the dose to a phantom was measured with EPID dosimetry and compared to the TPS dose calculated with and without normally distributed (2mm sigma) errors in MLC positions. The magnitude of 17 intensity histogram and size-zone radiomic features were derived from each image. The features that differed most significantly between image sets were determined with ROC analysis. A linear machine-learning model was trained on these features to classify images as with or without errors on 180 gamma images.The model was then applied to an independent validation set of 188 additional gamma distributions, half with and half without errors. Results: The most significant features for detecting errors were histogram kurtosis (p=0.007) and three size-zone metrics (p<1e-6 for each). The sizezone metrics detected clusters of high gamma-value pixels under mispositioned MLCs. The model applied to the validation set had an AUC of 0.8, compared to 0.56 for traditional gamma analysis with the decision threshold restricted to 98% or less. Conclusion: A radiomics-based image analysis method was developed that is more effective in detecting error than traditional gamma analysis. Though the pilot study here considers only MLC position errors, radiomics-based methods for other error types are being developed, which may provide better error detection and useful information on the source of detected errors. This work was partially supported by a grant from the Agency for Healthcare Research and Quality, grant number R18 HS022244-01.

60 APPLIED LIFE SCIENCES↗

Automatic Energy Calibration of Gamma-Ray Spectrometers

The software provides automatic method for calibrating the energy scale of high-purity germanium (HPGe) and scintillation gamma-ray spectrometers, using natural background radiation as the source of calibration gamma rays. In field gamma-ray spectroscopy, radioactive check sources may not be available; temperature changes can shift detector electronic gain and scintillator light output; and a user's experience and training may not include gamma-ray energy calibration. Hence, an automated method of calibrating the spectrometer using natural background would simplify its operation, especially by technician-level users, and by enhancing spectroscopic data quality, it would reduce false detections. Following a typically one-minute count of background gamma-rays, the measured spectrum is searched for gamma-ray peaks, producing a list of peak centroids, in channels1. Next, the ratio algorithm attempts to match the peak centroids found in the search to a user-supplied list of calibration gamma-ray energies. Finally, if three or more calibration energies have been matched to peaks, the energy equation parameters are determined by a least-squares fit2, and the spectrum has been energy-calibrated. The ratio algorithm rests on the repeatable but irregular spacing of the background gamma-ray energies together they form a unique set of ratios, when normalized to the highest energy calibration gamma ray; so too, the corresponding peak centroids in the spectrum. The algorithm matches energy ratios to peak centroid ratios, to determine which peak matches a given calibration energy.

Caffrey, Gus↗

GAMSOR: Gamma Source Preparation and DIF3D Flux Solution

Nuclear reactors that rely upon the fission reaction have two modes of thermal energy deposition in the reactor system: neutron absorption and gamma absorption. The gamma rays are typically generated by neutron capture reactions or during the fission process which means the primary driver of energy production is of course the neutron interaction. In conventional reactor physics methods, the gamma heating component is ignored such that the gamma absorption is forced to occur at the gamma emission site. For experimental reactor systems like EBR-II and FFTF, the placement of structural pins and assemblies internal to the core leads to problems with power heating predictions because there is no fission power source internal to the assembly to dictate a spatial distribution of the power. As part of the EBR-II support work in the 1980s, the GAMSOR code was developed to assist analysts in calculating the gamma heating. The GAMSOR code is a modified version of DIF3D and actually functions within a sequence of DIF3D calculations. The gamma flux in a conventional fission reactor system does not perturb the neutron flux and thus the gamma flux calculation can be cast as a fixed source problem given a solution to the steady state neutron flux equation. This leads to a sequence of DIF3D calculations, called the GAMSOR sequence, which involves solving the neutron flux, then the gamma flux, and then combining the results to do a summary edit. In this manuscript, we go over the GAMSOR code and detail how it is put together and functions. We also discuss how to setup the GAMSOR sequence and input for each DIF3D calculation in the GAMSOR sequence.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification of the MC2-3 Gamma Library

The new gamma library was generated based on the 94-group gamma structure, including delayed gamma and beta data, using the PreGAMMA and GenGAMMA codes with ENDF/BVII. 0 data. The new gamma library was first verified using the 2D benchmark problems that were introduced in the GAMSOR manual, showing that the neutron and gamma heatings from DIF3D were in good agreement with MCNP solutions within 5% even in the non-fuel regions of both cores with uranium or plutonium dominant fuel compositions. Similarly, the DIF3D power solutions for additional simpler 1D problems with 3 or 6 regions showed good agreement with MCNP solutions. Note that all DIF3D calculations were based on the 230- group neutron and 94-group gamma data. For the EBR-II benchmark problem, the DIF3D solution with the new gamma library maintained good agreement in the power distribution with the MCNP solution, which is comparable to the DIF3D results with the current 21-group gamma library. The use of delayed gamma and beta data increased powers at the dummy assemblies by 26%, which appears to be reasonable. Further detailed verification tests may be necessary and, more importantly, validation tests are required against measurement data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Gamma-ray Assay for Nuclear Materials Safeguards. Comprehensive Technology Readiness Assessment

Spectroscopic analysis of beta-delayed gamma-rays emitted from fission products following active interrogation was investigated as a non-destructive assay technique for detection and characterization of nuclear materials in shielded and complex configurations. This measurement technique is expected to be applicable to a variety of applications within the nuclear material safeguards, arms control, and emergency response areas, where active neutron interrogation is acceptable. Potential applications of the delayed gamma-ray assay in the nuclear material safeguards area include characterization of U and Pu isotopic content in spent and unirradiated nuclear fuel, enrichment measurements, verification of bulk material in containers, and the characterization of nuclear wastes. In the arms control area, this method can be used as a part of warhead dismantlement measurements to confirm separation of components, and may be applicable in warhead confirmation. In the context of emergency response, it can be used for detailed diagnostics of an unknown item. At present, the delayed gamma-ray assay technology reliably qualifies for the Technical Readiness Level 3 (TRL 3). The R&D work completed under this project has successfully demonstrated the empirical proof-of-concept for this active interrogation technology for a variety of measurement configurations, neutron sources, and nuclear material samples. A robust first-principles analytical signature modeling methodology was developed, experimentally validated, and can be easily extrapolated to a range of realistic measurement scenarios. Several response analysis methodologies have been implemented and deemed reliable for a variety of active interrogation applications in the areas of nuclear material safeguards, arms control, and emergency response. The initial readiness level before the start of this project was assessed at TRL 0, since only fragmentary records of the signature observations and speculative statements of the relevant non-destructive assay applications existed at that time. The delayed gamma-ray technology readiness can be easily advanced to TRL 4 in a short period, if a certain measurement application is specified and set for a demonstration in a laboratory environment. The critical hardware components of the delayed gamma-ray measurement technology (neutron generators, gamma-ray spectrometers) are readily available as COTS and can be configured for a specific deployment configuration. The primary risk of the delayed gamma-ray assay methodology is defined by the applicationspecific uncertainties. Evaluation of the system performance can be effectively completed once the expected measurement purpose, nuclear material characteristics, dimensions, and radiation exposure constraints are specified. A minor risk can be associated with the delayed gamma-ray response analysis techniques. Several approaches were proposed and demonstrated primarily using the modeled signatures. The observed performance may not be easily transferrable to the conditions of a real measurement setup, and some additional R&D may be required. Overall, the delayed gamma-ray assay technology can be recommended for follow-up demonstrations addressing relevant measurement applications in the areas of nuclear material safeguards, arms control, and emergency response.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Statistical Study to Determine the Origin of Long-duration Gamma-Ray Flares

Two scenarios have been proposed to account for sustained ≥30 MeV gamma-ray emission in solar flares: (1) prolonged particle acceleration/trapping involving large-scale magnetic loops at the flare site, and (2) precipitation of high-energy (>300 MeV) protons accelerated at coronal/interplanetary shock waves. To determine which of these scenarios is more likely, we examine the associated soft X-ray flares, coronal mass ejections (CMEs), and solar energetic proton events for (a) the long-duration gamma-ray flares (LDGRFs) observed by the Large Area Telescope on Fermi , and (b) delayed and/or spatially extended high-energy gamma-ray flares observed by the Gamma-ray Spectrometer on the Solar Maximum Mission , the Gamma-1 telescope on the Gamma satellite, and the Energetic Gamma-Ray Experiment Telescope on the Compton Gamma-Ray Observatory . For the Fermi data set of 11 LDGRFs with >100 MeV emission lasting for ≥~2 hr, we search for associations and reverse associations between LDGRFs, X-ray flares, CMEs, and SEPs, i.e., beginning with the gamma-ray flares and also, in turn, with X-class soft X-ray flares, fast (≥1500 km s -1 ) and wide CMEs, and intense (peak flux ≥2.67 × 10 -3 protons cm -2 s -1 sr -1 , with peak to background ratio >1.38) >300 MeV SEPs at 1 au. While LDGRFs tend to be associated with bright X-class flares, we find that only one-third of the X-class flares during the time of Fermi monitoring coincide with an LDGRF. However, nearly all fast, wide CMEs are associated with an LDGRF. These preliminary association analyses favor the proton precipitation scenario, however there is a prominent counter-example of a potentially magnetically well-connected solar eruption with >100 MeV emission for ~10 hr for which the near-Earth >300 MeV proton intensity did not rise above background.

58 GEOSCIENCES↗