Search NASA⌕ Search

SEARCH · Search NASA

Results for “Generations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Plasma Activated Water: A Technology for Acid Generation and Space Crop Production

As humanity returns to the moon and onward to Mars, sustainable space travel becomes essential for cost and independence from Earth. Astronaut activities in low Earth orbit resupply consumable materials and can require alternative technologies if transportation of chemicals is deemed hazardous. Plasma technology and applications are able to generate commodities that assist in achieving Earth independence. Plasma interaction with water generates acid in-situ using on-board resources of electricity and breathable air without the need for large infrastructure. At Kennedy Space Center, researchers have shown that plasma is able to produce nitric acid, and therefore nitrates, in a plant-usable form in water. In this report, the team presents results on acid generation in g/kW-hr as well as provides results on plasma activated water for plant growth assistance. Plasma was generated utilizing DC, AC, and pulsed power supplies in order to determine optimizing parameters for generation of this useful commodity.

Plasma↗

Airfoil Table Generation and Validation for the VR-12 and SSC-A09 Airfoils and Quadrotor Performance Prediction

As part of NASA’s Urban Air Mobility (UAM) mission, the Revolutionary Vertical Lift Technology (RVLT) project is creating rotorcraft reference designs that can be used by the rotorcraft community to develop quiet, efficient, and safer air vehicles. At NASA, this effort is made possible by the use of the RVLT toolchain software. Airfoil tables are often a critical part of the conceptual design process as they inform both comprehensive analysis and Computational Fluid Dynamics (CFD) codes of 2D aerodynamic coefficients, such as lift, drag, and moment coefficients. These airfoil tables, typically generated during experimental testing, are often proprietary and thus not widely distributable; further, there is not always clear or available reference documentation that provides information on the test conditions. The airfoil tables from these experiments are referred to in this work as Legacy airfoil tables. The scope of this study is to generate airfoil tables with the NASA OVERset grid CFD FLOW solver (OVERFLOW) coupled with the AirFoil Table Generator (AFTGen) software and validate these airfoil tables based on performance predictions calculated in Comprehensive Hierarchical Aeromechanics Rotorcraft Model (CHARM). The overall goal is to provide CFD generated airfoil tables, validate them through comprehensive analysis, and publish the airfoil tables for public distribution. The RVLT quadrotor reference model was selected as the basis for all analyses. The quadrotor uses the VR-12 and SSC-A09 airfoils for its rotor blades. Simulations were run in OVERFLOW for the VR-12 and SSC-A09 airfoils for ±20° angles of attack, Mach numbers from 0.3 to 1.0, and a Reynolds-Mach proportionality constant of 1.023x107. The C81 format airfoil tables from AFTGen were then blended with Legacy NACA 0012 airfoil table data for ±20° to ±180° angle of attack range. CHARM was used to compute thrust coefficient, power coefficient, and figure of merit for an isolated rotor in hover using proprietary legacy airfoil tables for the VR-12 and SSC-A09, as well as with the OVERFLOW generated airfoil tables for the VR-12 and SSC-A09. Overall, the OVERFLOW and Legacy performance predictions agreed well, with the best correlation between simulated and Legacy data observed with the VR-12 airfoil tables.

Airfoil↗

Simulated Multipath Using Software Generated GPS Signals

Depending on the environment, multipath can be one of the largest error sources contributing to degradation in Global Navigation Satellite System (GNSS) (e.g., GPS) performance. Multipath is a phenomenon that occurs as radio signals reflect off of surfaces, such as buildings, producing multiple copies of the original signal. When this occurs with GPS signals, it results in one or more delayed signals arriving at the receiver with or without the on-time/direct GPS signal. The receiver measures the composite of these signals which, depending on the severity of the multipath, can substantially degrade the accuracy of the receiver's calculated position. Multipath is commonly experienced in cities due to tall buildings and its mitigation is an ongoing area of study. This research demonstrates a novel approach for simulating GPS multipath through the modification of an open-source tool, GPS-SDR-SIM. The resulting additional testing capability could allow for improved development of multipath mitigating technologies. Currently, open-source tools for simulating GPS signals are available and can be used in the testing and evaluation of GPS receiver equipment. These tools can generate GPS signals that, when used by a GPS receiver, result in computation of a position solution that was pre-determined at the time of signal generation. That is, the signals produced are properly formed for the pre-determined location and result in the receiver reporting that position. This allows for a GPS receiver under test to be exposed to various simulated locations and conditions without having to be physically subjected to them. Additionally, while these signals are generated by a software simulation, they can be processed by real or software defined GPS receivers. This work utilizes the GPS-SDR-SIM software tool for GPS signal generation and while this tool does implement some sources of error that are inherent to GPS, it cannot inject multipath. GPS-SDR-SIM was modified in this effort to produce additional copies of signals with pre-determined delays. These additional delayed signals mimic multipath and represent what happens to GPS signals in the real world as they reflect off of surfaces and arrive at a receiver in place of or alongside the direct GPS signal. A successful proof of concept was prototyped and demonstrated using this modified version of GPS-SDR-SIM to produce simulated GPS signals as well as additional simulated multipath signals. The generated data was processed using a software defined GPS receiver and it was found that the introduction of simulated multipath signals successfully produced the expected characteristics of a composite multipath signal. Further maturation of this work could allow for the development of a GPS receiver testing and evaluation framework and aid in the development of multipath mitigating technologies.

GPS↗

Oxygen transport membrane reactor based method and system for generating electric power

A carbon capture enabled system and method for generating electric power and/or fuel from methane containing sources using oxygen transport membranes by first converting the methane containing feed gas into a high pressure synthesis gas. Then, in one configuration the synthesis gas is combusted in oxy-combustion mode in oxygen transport membranes based boiler reactor operating at a pressure at least twice that of ambient pressure and the heat generated heats steam in thermally coupled steam generation tubes within the boiler reactor; the steam is expanded in steam turbine to generate power; and the carbon dioxide rich effluent leaving the boiler reactor is processed to isolate carbon. In another configuration the synthesis gas is further treated in a gas conditioning system configured for carbon capture in a pre-combustion mode using water gas shift reactors and acid gas removal units to produce hydrogen or hydrogen-rich fuel gas that fuels an integrated gas turbine and steam turbine system to generate power. The disclosed method and system can also be adapted to integrate with coal gasification systems to produce power from both coal and methane containing sources with greater than 90% carbon isolation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Controllable Grid Interface for Testing Ancillary Service Controls and Fault Performance of Utility-Scale Wind Power Generation: Preprint

The rapid expansion of wind power has led many transmission system operators to demand modern wind power plants to comply with strict interconnection requirements. Such requirements involve various aspects of wind power plant operation, including fault ride-through and power quality performance as well as the provision of ancillary services to enhance grid reliability. During recent years, the National Renewable Energy Laboratory (NREL) of the U.S. Department of Energy has developed a new, groundbreaking testing apparatus and methodology to test and demonstrate many existing and future advanced controls for wind generation (and other renewable generation technologies) on the multimegawatt scale and medium-voltage levels. This paper describes the capabilities and control features of NREL's 7-MVA power electronic grid simulator (also called a controllable grid interface, or CGI) that enables testing many active and reactive power control features of modern wind turbine generators -- including inertial response, primary and secondary frequency responses, and voltage regulation -- under a controlled, medium-voltage grid environment. In particular, this paper focuses on the specifics of testing the balanced and unbalanced fault ride-through characteristics of wind turbine generators under simulated strong and weak medium-voltage grid conditions. In addition, this paper provides insights on the power hardware-in-the-loop feature implemented in the CGI to emulate (in real time) the conditions that might exist in various types of electric power systems under normal operations and/or contingency scenarios. Using actual test examples and simulation results, this paper describes the value of CGI as an ultimate modeling validation tool for all types of 'grid-friendly' controls by wind generation.

17 WIND ENERGY↗

Fully Solid State Thermomagnetoelectric Generator: Cycle Model and Proof-of-Concept Results

Electricity generation from heat in small-scale systems is currently limited to internal and external combustion heat engine generators or thermoelectric elements. This study introduces a new concept for a solid state thermomagnetoelectric power generator and presents a theoretical study of the cycle. While magnetocaloric materials (MCMs) are common in cryogenic cooling applications, in this work the magnetocaloric thermodynamic heat pump cycle is reversed to generate electricity from low-grade heat. A critical distinguishing feature of the approach is that there are no moving parts: the system directly converts heat into electricity with no moving magnet or regenerators (similar to thermoelectric elements). By periodic heating and cooling of the MCM, the magnetic field inside the copper coil changes in time, generating alternating current electricity. This fully solid state system can directly convert heat into electricity and is modeled at 54% of Carnot efficiency. Compared with state-of-the-art thermoelectric elements, the proposed technology has 3-4 times higher heat-to-electricity conversion efficiency at the same driving temperature difference.

Zhang, Mingkan↗

Temporal Graph Generation Based on a Distribution of Temporal Motifs

Generating a synthetic graph that is similar to a given real-world graph is a critical requirement for privacy preservation and benchmarking purposes. Various generative models attempt to generate static graphs similar to real-world graphs. However, generation of temporal graphs is still an open research area. We present a temporal-motif based approach to generate synthetic temporal graph datasets and results from three real-world use cases.

Purohit, Sumit↗

Steam generator with inclined tube sheet

A steam generation system may include a plurality of heat transfer tubes configured to circulate a secondary coolant of the steam generation system. The steam generation system may be thermally coupled to a reactor vessel, and the reactor vessel may be configured to house a primary coolant. Heat generated from within the reactor vessel may be transferred from the primary coolant to the secondary coolant. The steam generation system may further include an inclined tube sheet fluidly coupled to the plurality of heat transfer tubes. The inclined tube sheet may be attached to a wall of the reactor vessel in a non-horizontal orientation.

42 ENGINEERING↗

A Scalable Parallel Hypergraph Generator (HyGen)

Graphs are extensively used to model real-world complex systems. An edge in a graph can model pairwise relationships. However, multiway relationships (connections between three or more vertices) are common in many complex systems such as cellular process, image segmentation, and circuit design. A graph edge cannot model multiway relationships. A hypergraph, which can connect more than two vertices, is thus a better option to model multiway relationships. A large-scale hypergraph analysis has the potential to find useful insights from a complex system and assist in knowledge discovery. Currently a limited number of hypergraphs exists that are representative of real-world datasets. Moreover, real-world hypergraph datasets are small in size and inadequate to incorporate future needs. A graph generator that can produce large-scale synthetic hypergraphs can solve the above mentioned problems. In this paper, we present a scalable parallel hypergraph generator (HyGen) based on the Message Passing Interface (MPI) standard. To generate hypergraphs, HyGen takes the following parameter values as inputs: i) number of vertices, ii) number of hyperedges, iii) number of clusters, iv) vertex distribution, v) hyperedge distribution, vi) local cluster cardinality, and vii) global cluster cardinality. We have demonstrated that HyGen can generate hypergraphs of various sizes in a scalable fashion. HyGen takes approximately four minutes to generate a hypergraph with 4.8 million vertices, 1.6 million hyperedges, and 800 clusters using 1,024 processes on a leadership class computing platform. Our strong and weak scaling experiments on supercomputers demonstrate that HyGen can quickly create large-scale hypergraphs in a parallel manner, thus providing a useful capability for hypergraph analysis.

Hasan, S M Shamimul↗

Load following power generation and power storage using REP and PEM technology

A hydrogen generation system for generating hydrogen and electrical power includes a power supply, a reformer-electrolyzer-purifier (REP) assembly including at least one fuel cell including an anode and a cathode separated by an electrolyte matrix, at least one low temperature fuel cell, and a hydrogen storage. The at least one fuel cell is configured to receive a reverse voltage supplied by the power supply and generate hydrogen-containing gas in the anode of the at least one fuel cell. The at least one low temperature fuel cell is configured to receive the hydrogen-containing gas output from the REP assembly. The at least one low temperature fuel cell is configured to selectably operate in a power generation mode in which the hydrogen-containing gas is used to generate electrical power and a power storage mode in which the hydrogen-containing gas is pressurized and stored in the hydrogen storage.

Jahnke, Fred C.↗

Synthetic High Impedance Fault Data through Deep Convolutional Generated Adversarial Network

High impedance faults (HIFs) have always been significant challenge in the power grids. Researchers have developed some advanced protective methods to detect the HIFs. To test and validate these methods, large amounts of HIF data are required. This paper presents a synthetic HIF data generating method using the deep convolutional generated adversarial network (DCGAN). The DCGAN includes a generator module to create synthetic HIF waveform from random noises; and a discriminator module to identify the flaws of those synthetic data, which ultimately help improve the quality of the synthetic data created by the generator. To test the fidelity of the generated synthetic HIF data, two different HIF-detection methods have been applied. Extensive simulation results have validated the effectiveness of using the DCGAN to create synthetic HIF data.

Yang, Kun↗

System and method for combined heat and electric power generation

A system for combined heat and electric power generation, preferably including a heat reservoir and one or more electric generators, each preferably including a heat source and an energy converter. A method for combined heat and electric power generation, preferably including activating an electric generator, deactivating the electric generator, and/or providing heat from a heat reservoir.

Lorimer, Adam↗

Integrated rectifier-generator system for AC-to-DC conversion

This disclosure relates AC-to-DC rectification and power flow control of electrical power generators. An integrated rectifier-generator AC-DC conversion circuit and system are disclosed for providing a regulated DC output. The integrated rectifier-generator AC-DC conversion circuit and system may include serially stacked passive and active rectifiers connected to multiple AC ports of an electrical power generator driven by mechanical energy captured by an energy harvester. The integrated rectifier-generator AC-DC conversion circuit and system may be configured to perform active ripple control and a maximum power tracking from the energy harvester by controlling a fraction of an overall power that flow through the active rectifier.

Huynh, Phuc Thanh↗

Computer-aided design file format for additive manufacturing and methods of file generation

A method of generating a tessellated output file comprising receiving a computer-aided design (CAD) model file defining a CAD model including a plurality of vertices, a plurality of curves, a plurality of surfaces, and at least one volume; generating base polygon data defining the CAD model for additive manufacturing, the base polygon data including a plurality of connected polygons, each polygon including a plurality of nodes, a plurality of edges, and a face; generating data for a vertex metadata container including a listing of CAD model vertices and one polygon node associated with each CAD model vertex; generating data for a curve metadata container including a listing of CAD model curves and at least one polygon edge associated with each CAD model curve; and generating data for a surface metadata container including a listing of CAD model surfaces and at least one polygon face associated with each CAD model surface.

Vernon, Gregory John↗

Steam generator for fuel cell applications

A steam vaporizer assembly includes an internal steam generator having a vessel configured to hold water, a vaporizer unit having a heating element configured to heat the water to generate saturated steam; and a controller configured to: cause the heating element to heat the water to a stand-by temperature; and while maintaining a water level of the water in the vessel between two control points: maintain the water in the vessel at the stand-by temperature until steam generation is required, and when steam generation is required, heating the water in the vessel from the stand-by temperature to a temperature at or above a vaporization temperature of the water using a heating element, to generate the steam.

Dobek, Frank↗

Generation of Isocurvature from Curvature Inhomogeneities on Super-Horizon Scales

Here it is shown 1) how isocurvature inhomogeneities correlated on causally disconnected (super-horizon) scales are generated from curvature inhomogeneities which are known to be correlated on these scales 2) that super-horizon isocurvature generation is nearly inevitable for non-equilibrium chemical processes 3) that the amplitude of the compositional isocurvature correlations a) can be large for production of rare objects, b) falls off rapidly with separation c) falls off at scales below the horizon when these modes are generated. These two fall-offs results in an "isocurvature bump" in the power spectrum. Isocurvature generation is illustrated by the process of dark matter freeze-in, computed here with both separate universe modelling and linear perturbation theory. For freeze-in the most prominent isocurvature modes are inhomogeneities in the ratio of dark matter to standard model matter. Much smaller inhomogeneities in the ratio of baryons to standard model entropy are also produced. Previous constraints on freeze-in from Ly-$\alpha$ clouds limit the bump enhancement to $\lesssim10\%$ on comoving scales $\lesssim1\,$Mpc. Current observations are not sensitive to the isocurvature modes generated in viable freeze-in models. Results are obtained using a somewhat novel framework to describe cosmological inhomogeneities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

System and method for combined heat and electric power generation

A system for combined heat and electric power generation, preferably including a heat reservoir and one or more electric generators, each preferably including a heat source and an energy converter. A method for combined heat and electric power generation, preferably including activating an electric generator, deactivating the electric generator, and/or providing heat from a heat reservoir.

Lorimer, Adam G.↗

Evaluating the Impact of Managed EV Charging for Reliable Operation of Bulk Power Systems with High Non-Dispatchable Generation

The growth of electric vehicles (EVs) and variable-generation (VG) sources introduces new challenges for power-system operations. This study introduces a modeling framework and evaluates five EV charging strategies under projected 2040 grid conditions in the Evergy service territory with high non-dispatchable generation. Using realistic EV behavior and generation models, their impacts on system peak demand, ramp rate, and reserve capacity are evaluated. Results show that only the peak-avoidance strategy effectively reduces system peak demand, while decentralized strategies-particularly cost based dynamic charging-can exacerbate peaks due to synchronized user behavior. However, ramp-rate minimization strategy significantly reduce the stress on dispatchable generation achieving the lowest maximum absolute ramp rate (MARR) (56.81 MW) and lowest reserve requirement (2.39 GW). In contrast, unmanaged and TOU random strategies increase the stress on dispatchable generation sources with increased MARR and reserve requirements. These findings highlight the importance of coordinated, system-aware managed charging strategies to ensure reliable and affordable grid operation in the presence of EVs and VG sources.

14 - SOLAR ENERGY↗