Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

A High-Fidelity Electromagnetic Transient Model of Inverter-based Resources Integrated to an IEEE-9 Bus System for Benchmarking Studies

An inverter-based resource (IBR) is a source of electricity that is asynchronously connected to the electrical grid via an electronic power converter. These power sources lack the intrinsic behaviors of the standard power plants, presenting specific challenges to system stability. These power sources lack the intrinsic behaviors of the standards power plants and their features are almost entirely defined by the control strategy used on them, presenting specific challenges to system stability as their penetration increases into the already fragile Bulk Power System (BPS). Utilizing renewable energy has a great upside but the electrical industry needs to understand the requirements like performing electromagnetic transient (EMT) simulation studies in planning and/or in interconnection studies. This paper presents the development of a high-fidelity EMT model based on commercial equipment and field parameters, which at the same time aims to study the increasing penetration of IBRs and their impact on the actual BPS. The open-source EMT model developed will be a benchmarking example that can be used to evaluate algorithms in the power grid (including evaluating grid-forming controls, power system monitoring and operation, etc.).

Martinez Montejano, Misael↗

Jitter Controller Software

Sinusoidal jitter is produced by simply modulating a clock frequency sinusoidally with a given frequency and amplitude. But this can be expressed as phase jitter, frequency jitter, or cycle-to-cycle jitter, rms or peak, absolute units, or normalized to the base clock frequency. Jitter using other waveforms requires calculating and downloading these waveforms to an arbitrary waveform generator, and helping the user manage relationships among phase jitter crest factor, frequency jitter crest factor, and cycle-to-cycle jitter (CCJ) crest factor. Software was developed for managing these relationships, automatically configuring the generator, and saving test results documentation. Tighter management of clock jitter and jitter sensitivity is required by new codes that further extend the already high performance of space communication links, completely correcting symbol error rates higher than 10 percent, and therefore typically requiring demodulation and symbol synchronization hardware to operating at signal-to-noise ratios of less than one. To accomplish this, greater demands are also made on transmitter performance, and measurement techniques are needed to confirm performance. It was discovered early that sinusoidal jitter can be stepped on a grid such that one can connect points by constant phase jitter, constant frequency jitter, or constant cycle-cycle jitter. The tool automates adherence to a grid while also allowing adjustments off-grid. Also, the jitter can be set by the user on any dimension and the others are calculated. The calculations are all recorded, allowing the data to be rapidly plotted or re-plotted against different interpretations just by changing pointers to columns. A key advantage is taking data on a carefully controlled grid, which allowed a single data set to be post-analyzed many different ways. Another innovation was building a software tool to provide very tight coupling between the generator and the recorded data product, and the operator's worksheet. Together, these allowed the operator to sweep the jitter stimulus quickly along any of three dimensions and focus on the response of the system under test (response was jitter transfer ratio, or performance degradation to the symbol or codeword error rate). Additionally, managing multi-tone and noise waveforms automated a tedious manual process, and provided almost instantaneous decision- making control over test flow. The code was written in LabVIEW, and calls Agilent instrument drivers to write to the generator hardware.

Lansdowne, Chatwin↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

The U.S. Department of Energy (DOE) has launched a Connected Communities program that supports projects that expand DOE's network of grid-interactive, efficient building communities nationwide. As an early pilot of Connected Communities, the National Renewable Energy Laboratory (NREL) and its partners have developed and demonstrated a community-scale, hierarchical control solution to address the potential grid issues arising from high penetration of solar photovoltaics (PV) as well as to improve grid reliability and resilience in this residential community. A field pilot study has been performed at an affordable housing development called the Basalt Vista Community, which was built for school teachers and other professionals in the local workforce and represents an autonomous energy grid with all-electric, energy-efficient homes. With no natural gas line in the community, this is the first all-electric net-zero community in rural Colorado. In the field pilot study, NREL has validated the performance of the hierarchical control solution, which consists of NREL's foresee home energy management systems (HEMS) and community aggregators, in increasing demand flexibility and self-consuming PV, reducing potential over-voltages, and supporting critical loads during emergency events. In this presentation, we will present the methodology, simulation and field pilot results, and lessons learned from the project.

all-electric community↗

Design and dispatch optimization of packaged ice storage systems within a connected community

The traditional implementation of cool thermal energy storage (CTES) must be reimagined within the context of a dynamic grid and smart buildings operating as connected communities. As most buildings do not operate central chillers or connect to district cooling loops, this necessitates a broader use of packaged CTES. Our objective is to begin answering the question of how such packaged CTES should be implemented within a connected community. We do so by presenting a simulation–optimization workflow employing building energy modeling software and a mixed-integer linear program to design and dispatch a packaged CTES technology to achieve minimum total annual cost. We demonstrate this methodology on a seven-building case study using current utility rates and find that total annual cooling energy costs can be reduced by 17.8% compared to baseline, after accounting for the cost of storage. We perform three parametric sensitivity studies to evaluate modeling assumptions and obtain the prioritization of storage procurement as a function of annualized life-cycle cost of storage. We find that a community optimization approach provides significantly different results than individual building optimizations and provides greater savings compared to baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The OSG open facility: A sharing ecosystem

The Open Science Grid (OSG) ties together individual experiments’ computing power, connecting their resources to create a large, robust computing grid, this computing infrastructure started primarily as a collection of sites associated with large HEP experiments such as ATLAS, CDF, CMS, and DZero. In the years since, the OSG has broadened its focus to also address the needs of other US researchers and increased delivery of Distributed High Through-put Computing (DHTC) to users from a wide variety of disciplines via the OSG Open Facility. Presently, the Open Facility delivers about 100 million computing wall hours per year to researchers who are not already associated with the owners of the computing sites, this is primarily accomplished by harvesting and organizing the temporarily unused capacity (i.e. opportunistic cycles) from the sites in the OSG. Using these methods, OSG resource providers and scientists share computing hours with researchers in many other fields to enable their science, striving to make sure that these computing power used with maximal efficiency. Furthermore, we believe that expanded access to DHTC is an essential tool for scientific innovation and work continues in expanding this service.

97 MATHEMATICS AND COMPUTING↗

Gating grid driver for gas radiation detectors

A gating grid driver for use with radiation detectors, such as time projection chambers and other similar devices that require a gating grid that operates in a bipolar mode with different electrostatic potentials on alternating wires. To open such gating grids, the driver shorts the alternate wires to a common voltage Va. Later, this driver closes the grid by restoring the voltage differences in the adjacent wires. By connecting the driver circuit to the gating grid via low impedance transmission lines, the driver circuit opens the gating grid in 0.35 μs, minimizing the lost drift length associated with this opening time. The circuit consists of 2 pairs of N- and P-MOSFET switches and includes two adjustable capacitors and resistors that can be used to adjust the opening time, and shift the balance of positive and negative charge for individual radiation detector.

Tangwancharoen, Suwat↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Insulation Requirements

Medium voltage SiC devices facilitate direct (without 50/60 Hz transformer) connection of the power electronics converter to the medium voltage grid using simple topology. Compared to the insulation design of medium voltage inductors that have been widely used in the power system, the insulation design of directly connected medium voltage converter filter inductors has more challenges. Although some works has been done discussing that, the grid insulation requirements on converter filter inductors are rarely discussed. This paper introduces the insulation design of a grid-side filter inductor for a 13.8 kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, as well as the local electrical field have been taken into consideration. Experimental tests are provided to validate the design.

Li, Haiguo↗

Three-phase Four-leg Inverter LabVIEW FPGA Control Code [SWR-16-26]

In the area of power electronics control, Field Programmable Gate Arrays (FPGAs) have the capability to outperform their Digital Signal Processor (DSP) counterparts due to the FPGA’s ability to implement true parallel processing and therefore facilitate higher switching frequencies, higher control bandwidth, and/or enhanced functionality. National Instruments (NI) has developed two platforms, Compact RIO (cRIO) and Single Board RIO (sbRIO), which combine a real-time processor with an FPGA. The FPGA can be programmed with a subset of the well-known LabVIEW graphical programming language. The use of cRIO and sbRIO for power electronics control has developed over the last few years to include control of three-phase inverters. Most three-phase inverter topologies include three switching legs. The addition of a fourth-leg to natively generate the neutral connection allows the inverter to serve single-phase loads in a microgrid or stand-alone power system and to balance the three-phase voltages in the presence of significant load imbalance. However, the control of a four-leg inverter is much more complex. In particular, instead of standard two-dimensional space vector modulation (SVM), the inverter requires three-dimensional space vector modulation (3D-SVM). The candidate software implements complete control algorithms in LabVIEW FPGA for a three-phase four-leg inverter. The software includes feedback control loops, three-dimensional space vector modulation gate-drive algorithms, advanced alarm handling capabilities, contactor control, power measurements, and debugging and tuning tools. The feedback control loops allow inverter operation in AC voltage control, AC current control, or DC bus voltage control modes based on external mode selection by a user or supervisory controller. The software includes the ability to synchronize its AC output to the grid or other voltage-source before connection. The software also includes provisions to allow inverter operation in parallel with other voltage regulating devices on the AC or DC buses. This flexibility allows the Inverter to operate as a stand-alone voltage source, connected to the grid, or in parallel with other controllable voltage sources as part of a microgrid or remote power system. In addition, as the inverter is expected to operate under severe unbalanced conditions, the software includes algorithms to accurately compute real and reactive power for each phase based on definitions provided in the IEEE Standard 1459: IEEE Standard Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced, or Unbalanced Conditions. Finally, the software includes code to output analog signals for debugging and for tuning of control loops. The software fits on the Xilinx Virtex V LX110 FPGA embedded in the NI cRIO-9118 FPGA chassis, and with a 40 MHz base clock, supports a modulation update rate of 40 MHz, user-settable switching frequencies and synchronized control loop update rates of tens of kHz, and reference waveform generation, including Phase Lock Loop (PLL), update rate of 100 kHz.

Martin, Gregory↗

Radiation-hardened fast acquisition/weak signal tracking system and method

A global positioning system (GPS) receiver and method of acquiring and tracking GPS signals comprises an antenna adapted to receive GPS signals; an analog radio frequency device operatively connected to the antenna and adapted to convert the GPS signals from an analog format to a digital format; a plurality of GPS signal tracking correlators operatively connected to the analog RF device; a GPS signal acquisition component operatively connected to the analog RF device and the plurality of GPS signal tracking correlators, wherein the GPS signal acquisition component is adapted to calculate a maximum vector on a databit correlation grid; and a microprocessor operatively connected to the plurality of GPS signal tracking correlators and the GPS signal acquisition component, wherein the microprocessor is adapted to compare the maximum vector with a predetermined correlation threshold to allow the GPS signal to be fully acquired and tracked.

Winternitz, Luke↗

Assessing the vulnerability of solar inverters to EMPs: Port testing, PCI modeling, and protection strategies

Renewable energy sources are becoming an ever-larger contributor to the power grid. These renewable energy sources depend upon the power electronic devices, specifically inverters, being essential for connecting Photovoltaic (PV) generation to the grid. However, the Electromagnetic Pulses (EMPs) caused by the high-altitude nuclear explosions can generate fast broad-band pulses with nanosecond rise time, potentially causing damage or destruction to electronic components. To assess the vulnerability of PV inverters to high-altitude EMPs, the port testing and Pulsed Current Injection (PCI) modeling schemes are proposed based on the port impedance analysis. Wide-band frequency measurements are achieved by fusing impedance results from three vector network analyzers. Then, a PCI model is used to simulate the induced response to EMP, with two typical immunity levels of EC5 and EC8 tested. Here, the experiment successfully excites the induced voltage and current under EMP, where the voltage and current can reach 1500V/40A and 8000V/150Aunder EC5 andEC8, respectively. The port vulnerability analysis results demonstrate that only some ports can survive under EC5. To defend against the impact of EMP, three protection strategies are discussed.

42 ENGINEERING↗

Model Predictive Voltage Control of Large-Scale PV or Hybrid PV-BESS Plants

Increased penetration level of inverter-based resources (IBRs) and renewable energy in the power grid has called for more requirements from the control of IBRs. In this paper, the voltage-reactive power control of a photovoltaic (PV) power plant or hybrid PV-battery energy storage system (BESS) plant connected to a bulk power grid, whilst meeting the grid requirements, is studied. In this paper, a continuous-set model predictive control (MPC) formulation is proposed for voltage-reactive power control. For the same, an aggregated dynamic PV plant model is developed based on the recursive system equivalencing method. The formulation is then implemented in PSCAD simulation on a 125 MW PV plant or hybrid PV-BESS plant. The MPC implementation achieves 10.13% voltage improvement based on PSCAD simulation results in a balanced fault case study. Simulation results further demonstrate that MPC provides improved voltage support over the conventional proportional-integral (PI) controller post-fault occurrence.

Abu rub, Omar↗

Facilitating the Portability of User Applications in Grid Environments

Grid computing promises the ability to connect geographically and organizationally distributed resources to increase effective computational power, resource utilization, and resource accessibility. For grid computing to be successful, however, users must be able to easily execute the same application on different resources. Different resources, however, may be administered by different organizations with different software installed, different file system structures, and different default environment settings. Even within the same organization, the set of software installed on a given resource is in constant flux with additions, upgrades, and removals. Users cannot be expected to understand all of the idiosyncrasies of each resource they may wish to execute jobs on, thus must be provided with automated assistance. This paper describes a new OGSI-compliant grid service (the Portability Manager) that has been implemented as part of NASA's Information Power Grid (IPG) project to automatically estab!ish the execution environment for user applications.

Kolano, Paul Z.↗

A Guide to Current Limiting and Stability with Grid-Forming Inverters

The electric power grid is changing. For many decades, the synchronous generator - an electromechanical device invented in 1887 - has been the workhorse and backbone of power grids across the globe. Our entire infrastructure is built around it. But times change, and so does the power grid. Since the early 21st century, we have seen a gradual shift in modern power grids away from synchronous generators to ones dominated by power electronic inverter-based resources (IBRs). Sources such as photovoltaics, wind turbines, battery storage, fuel cells, and other technologies like high-voltage DC transmission interconnections all rely on an inverter to connect and interface with the grid. They are increasingly being installed on the grid to augment, or even replace, traditional energy sources. This change is a fundamental shift that brings tremendous technical challenges and questions: Can a power grid remain stable with many more inverter-based resources? How do we avoid more blackouts on the grid? How do we keep the grid secure and resilient during disturbances? After all, power electronic inverters are nothing like the big, rotating, iron-and-copper machines that the grid heavily relies on. Many of these questions can be answered by using grid-forming (GFM) inverters, yet many research challenges remain. This document explores GFM inverters and how they can help stabilize the future grid, especially during disturbances and contingencies. It summarizes a two-year research and development fellowship program at NREL. We point interested readers to more detailed works developed during the project along the way. Let's dive in

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Refrigeration Units in Off Grid PV/Wind Hybrid Systems on Tribal Land

This paper looks at the performance of residential refrigeration units in off-grid photovoltaic and small wind hybrid (PV/wind) systems with battery storage. Off grid hybrid power systems, dispatched by Navajo Tribal Utility Authority (NTUA), allow Navajo Nation residents in rural areas to have the benefits of electricity. On the Navajo Nation, the rural and rugged nature of the land results in a high capital cost to connecting a house to the grid. In this case, a hybrid PV/wind power generation system may be used at a much lower cost to the customer. In providing affordable power systems to customers, the systems are designed to provide adequate power for use. This requires a constant conservative use of electricity. For systems with refrigerators which are large alternating current (AC) loads, there are performance issues that arise. NTUA reports that new energy star rated refrigerators have performance issues in working with these off grid systems. This paper looks at ways to improve the performance of these systems with the use of a refrigeration unit. This involves looking at conventional refrigerators with its operation. This paper also looks at alternative methods of refrigeration. Also, the power system is looked at to increase the performance in maintaining a proper balance of the system. Lastly, solutions will be recommended to solve the refrigeration issues faced by NTUA.

14 SOLAR ENERGY↗

The Feasibility of Moving PMU Data in the Future Power Grid

The power grid is a complex network connecting electricity providers with their consumers. With an increasing consumer base requiring more resources and the requirement to integrate significant renewable sources, maintaining the network requires new and innovative management solutions. To manage this complexity and provide precise, real-time views of the grid, Phasor Measurement Units (PMUs) are undergoing widespread deployment. These units provide measurements as often as 60 times per second, with an accurate time identifier attached to each reading, enabling real-time monitoring of the network. However, this new capability generates much more data than the current infrastructure is designed to handle. With the expectation that there will eventually be tens of thousands of PMUs monitoring the transmission lines, the power community is looking towards accumulating multiple terabytes of data per day - several orders of magnitude beyond current data acquisition rates. This has led to questions being raised in the power community about whether or not a significant research effort is required to effectively transfer the volume of information generated by these new data streams. This paper answers that question by comparing a worst-case data generation scenario with several alternative networking protocols and historical trends in protocol advancement. Based on this analysis we are able to conclude that transferring the information between the PMUs and the resulting data repositories is feasible. We recognize that there are issues beyond transferring the data that need to be addressed such as effective access to historical data, data transfer latency, cyber security, and data analysis. There is also an extensive engineering trade-off that the power companies will need to make to decide the best mix of networking protocols for their particular PMU deployments, since that requires significant assumptions about proprietary information including deployment cost, deployment schedules, PMU locations, and available resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Requirements

Medium voltage (MV) SiC devices facilitate direct (without 50-/60-Hz transformer) connection of the power electronics converter to the MV grid using simple topology. Compared to the insulation design of MV inductors that have been widely used in the power system, the insulation design of the MV converter filter inductors has new challenges. Particularly, the grid impact on insulation requirements on converter filter inductors is rarely discussed. This article introduces the insulation design of a grid-side filter inductor for a 13.8-kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, the local electric field, as well as the interturn transient voltage distribution are considered. Furthermore, the designed inductors are validated by the 46 kV (>1 min) dc hi-pot test, 12-kV ac partial discharge test, one-hour single-phase converter full rating test, as well as three-phase converter full rating test.

42 ENGINEERING↗