Search NASA⌕ Search

SEARCH · Search NASA

Results for “High precision control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Merits of flywheels for spacecraft energy storage

Flywheel energy storage systems which have a very good potential for use in spacecraft are discussed. This system can be superior to alkaline secondary batteries and regenerable fuel cells in most of the areas that are important in spacecraft applications. Of special importance, relative to batteries, are lighter weight, longer cycle and operating life, and high efficiency which minimizes solar array size and the amount of orbital makeup fuel required. Flywheel systems have a long shelf life, give a precise state of charge indication, have modest thermal control needs, are capable of multiple discharges per orbit, have simple ground handling needs, and have characteristics which would be useful for military applications. The major disadvantages of flywheel energy storage systems are that: power is not available during the launch phase without special provisions; and in flight failure of units may force shutdown of good counter rotating units, amplifying the effects of failure and limiting power distribution system options; no inherent emergency power capability unless specifically designed for, and a high level of complexity compared with batteries. The potential advantages of the flywheel energy storage system far outweigh the disadvantages.

Gross, S.↗

Optimal control of quaternion propagation errors in spacecraft navigation

Optimal control techniques are used to drive the numerical error (truncation, roundoff, commutation) in computing the quaternion vector to zero. The normalization of the quaternion is carried out by appropriate choice of a performance index, which can be optimized. The error equations are derived from Friedland's (1978) theoretical development, and a matrix Riccati equation results for the computation of the gain matrix. Simulation results show that a high precision of the order of 10 to the -12th can be obtained using this technique in meeting the q(T)q=1 constraint. The performance of the estimator in the presence of the feedback control that maintains the normalization, is studied.

Vathsal, S.↗

Self-Assembly of Quantum Dot–Gold Heterodimer Nanocrystals with Orientational Order

The self-assembly of nanocrystals into ordered superlattices is a powerful strategy for the production of functional nanomaterials. The assembly of well-ordered target structures, however, requires control over the building blocks’ size and shape as well as their interactions. While nanocrystals with homogeneous composition are now routinely synthesized with high precision and assembled into various ordered structures, high-quality multicomponent nanocrystals and their ordered assemblies are rarely reported. In this paper, we demonstrate the synthesis of quantum dot–gold (QD-Au) heterodimers. These heterodimers possess a uniform shape and narrow size distribution and are capped with oleylamine and dodecyltrimethylammonium bromide (DTAB). Assembly of the heterodimers results in a superlattice with long-range orientational alignment of dimers. Using synchrotron-based X-ray measurements, we characterize the complex superstructure formed from the dimers. Molecular dynamics simulations of a coarse-grained model suggest that anisotropic interactions between the quantum dot and gold components of the dimer drive superlattice formation. The high degree of orientational order demonstrated in this work is a potential route to nanomaterials with useful optoelectronic properties.

36 MATERIALS SCIENCE↗

Detecting defects that reduce breakdown voltage using machine learning and optical profilometry

Abstract Semiconductor wafer manufacturing relies on the precise control of various performance metrics to ensure the quality and reliability of integrated circuits. In particular, GaN has properties that are advantageous for high voltage and high frequency power devices; however, defects in the substrate growth and manufacturing are preventing vertical devices from performing optimally. This paper explores the application of machine learning techniques utilizing data obtained from optical profilometry as input variables to predict the probability of a wafer meeting performance metrics, specifically the breakdown voltage (V bk ). By incorporating machine learning techniques, it is possible to reliably predict performance metrics that cause devices to fail at low voltage. For diodes that fail at a higher (but still below theoretical) breakdown voltage, alternative inspection methods or a combination of several experimental techniques may be necessary.

42 ENGINEERING↗

Roadmap on basic research needs for laser technology

Motivated by the profound impact of laser technology on science, arising from an increase in focused light intensity by seven orders of magnitude and flashes so short electron motion is visible, this roadmap outlines the paths forward in laser technology to enable the next generation of science and applications. Despite remarkable progress, the field confronts challenges in developing compact, high-power sources, enhancing scalability and efficiency, and ensuring safety standards. Future research endeavors aim to revolutionize laser power, energy, repetition rate and precision control; to transform mid-infrared sources; to revolutionize approaches to field control and frequency conversion. These require reinvention of materials and optics to enable intense laser science and interdisciplinary collaboration. The roadmap underscores the dynamic nature of laser technology and its potential to address global challenges, propelling progress and fostering sustainable development. Ultimately, advancements in laser technology hold promise to revolutionize myriad applications, heralding a future defined by innovation, efficiency, and sustainability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applied metrology in the production of superconducting model magnets for particle accelerators

The production of superconducting magnets for particle accelerators involves high precision assemblies and tight tolerances, in order to achieve the requirements for their appropriate performance. It is therefore essential to have a strict control and traceability over the geometry of each component of the system, and also to be able to compensate possible inherent deviations coming from the production process.

43 PARTICLE ACCELERATORS↗

Facet-selective etching trajectories of individual semiconductor nanocrystals

The size and shape of semiconductor nanocrystals govern their optical and electronic properties. Liquid cell transmission electron microscopy (LCTEM) is an emerging tool that can directly visualize nanoscale chemical transformations and therefore inform the precise synthesis of nanostructures with desired functions. However, it remains difficult to controllably investigate the reactions of semiconductor nanocrystals with LCTEM, because of the highly reactive environment formed by radiolysis of liquid. Here, we harness the radiolysis processes and report the single-particle etching trajectories of prototypical semiconductor nanomaterials with well-defined crystalline facets. Lead selenide nanocubes represent an isotropic structure that retains the cubic shape during etching via a layer-by-layer mechanism. The anisotropic arrow-shaped cadmium selenide nanorods have polar facets terminated by either cadmium or selenium atoms, and the transformation trajectory is driven by etching the selenium-terminated facets. LCTEM trajectories reveal how nanoscale shape transformations of semiconductors are governed by the reactivity of specific facets in liquid environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Protein Turnover Signaling Motif Controls the Stimulus-Sensitivity of Stress Response Pathways

Stimulus-induced perturbations from the steady state are a hallmark of signal transduction. In some signaling modules, the steady state is characterized by rapid synthesis and degradation of signaling proteins. Conspicuous among these are the p53 tumor suppressor, its negative regulator Mdm2, and the negative feedback regulator of NFkB, IkBa. We investigated the physiological importance of this turnover, or flux, using a computational method that allows flux to be systematically altered independently of the steady state protein abundances. Applying our method to a prototypical signaling module, we show that flux can precisely control the dynamic response to perturbation. Next, we applied our method to experimentally validated models of p53 and NFkB signaling. We find that high p53 flux is required for oscillations in response to a saturating dose of ionizing radiation (IR). In contrast, high flux of Mdm2 is not required for oscillations but preserves p53 sensitivity to sub-saturating doses of IR. In the NFkB system, degradation of NFkB-bound IkB by the IkB kinase (IKK) is required for activation in response to TNF, while high IKK-independent degradation prevents spurious activation in response to metabolic stress or low doses of TNF. Our work identifies flux pairs with opposing functional effects as a signaling motif that controls the stimulus-sensitivity of the p53 and NFkB stress-response pathways, and may constitute a general design principle in signaling pathways.

59 BASIC BIOLOGICAL SCIENCES↗

A search for the prewetting line

This paper describes efforts to locate the prewetting line in a binary liquid system (isopropanol-perfluoromethylcyclohexane) at the vapor-liquid interface. Tight upper bounds were placed on the temperature separation (0.2 K) between the prewetting line and the line of bulk liquid phase separation. The prewetting line in systems at equilibrium was not detected. Experimental signatures indicative of the prewetting line occurred only in nonequilibrium situations. Several theories predict that the adsorption of one of the components (the fluorocarbon, in this case) at the liquid-vapor interface should increase abruptly, at a temperature sightly above the temperature at which the mixture separates into two liquid phases. A regular solution calculation indicates that this prewetting line should have been easily detectable with the instruments used in this experiment. Significant features of the experiment are: (1) low-gradient thermostatting, (2) in situ stirring, (3) precision ellipsometry from the vapor-liquid interface, (4) high resolution differential index of refraction measurements using a novel cell design, and (5) computer control.

Schmidt, J. W.↗

Digital identification of cartographic control points

Techniques have been developed for the sub-pixel location of control points in satellite images returned by the Voyager spacecraft. The procedure uses digital imaging data in the neighborhood of the point to form a multipicture model of a piece of the surface. Comparison of this model with the digital image in each picture determines the control point locations to about a tenth of a pixel. At this level of precision, previously insignificant effects must be considered, including chromatic aberration, high level imaging distortions, and systematic errors due to navigation uncertainties. Use of these methods in the study of Jupiter's satellite Io has proven very fruitful.

Gaskell, R. W.↗

Precise Measurement for Manufacturing

A metrology instrument known as PhaseCam supports a wide range of applications, from testing large optics to controlling factory production processes. This dynamic interferometer system enables precise measurement of three-dimensional surfaces in the manufacturing industry, delivering speed and high-resolution accuracy in even the most challenging environments.Compact and reliable, PhaseCam enables users to make interferometric measurements right on the factory floor. The system can be configured for many different applications, including mirror phasing, vacuum/cryogenic testing, motion/modal analysis, and flow visualization.

Source record↗

Micro-Slit Collimators for X-Ray/Gamma-Ray Imaging

A hybrid photochemical-machining process is coupled with precision stack lamination to allow for the fabrication of multiple ultra-high-resolution grids on a single array substrate. In addition, special fixturing and etching techniques have been developed that allow higher-resolution multi-grid collimators to be fabricated. Building on past work of developing a manufacturing technique for fabricating multi-grid, high-resolution coating modulation collimators for arcsecond and subarcsecond x-ray and gamma-ray imaging, the current work reduces the grid pitch by almost a factor of two, down to 22 microns. Additionally, a process was developed for reducing thin, high-Z (tungsten or molybdenum) from the thinnest commercially available foil (25 microns thick) down to approximately equal to 10 microns thick using precisely controlled chemical etching

Appleby, Michael↗

Systematic Error Mitigation for the PIXIE Instrument

The Primordial Ination Explorer (PIXIE) uses a nulling Fourier Transform Spectrometer to measure the absoluteintensity and linear polarization of the cosmic microwave background and diuse astrophysical foregrounds.PIXIE will search for the signature of primordial ination and will characterize distortions from a blackbodyspectrum, both to precision of a few parts per billion. Rigorous control of potential instrumental eects isrequired to take advantage of the raw sensitivity. PIXIE employs a highly symmetric design using multipledierential nulling to reduce the instrumental signature to negligible levels. We discuss the systematic errorbudget and mitigation strategies for the PIXIE mission.

Kogut, Alan↗

Multinozzle Emitter Arrays for Nanoelectrospray Mass Spectrometry

Mass spectrometry (MS) is the enabling technology for proteomics and metabolomics. However, dramatic improvements in both sensitivity and throughput are still required to achieve routine MS-based single cell proteomics and metabolomics. Here, we report the silicon-based monolithic multinozzle emitter array (MEA), and demonstrate its proof-of-principle applications in high-sensitivity and high-throughput nanoelectrospray mass spectrometry. Our MEA consists of 96 identical 10-nozzle emitters in a circular array on a 3-inch silicon chip. The geometry and configuration of the emitters, the dimension and number of the nozzles, and the micropillar arrays embedded in the main channel, can be systematically and precisely controlled during the microfabrication process. Combining electrostatic simulation and experimental testing, we demonstrated that sharpened-end geometry at the stem of the individual multinozzle emitter significantly enhanced the electric fields at its protruding nozzle tips, enabling sequential nanoelectrospray for the high-density emitter array. We showed that electrospray current of the multinozzle emitter at a given total flow rate was approximately proportional to the square root of the number of its spraying-nozzles, suggesting the capability of high MS sensitivity for multinozzle emitters. Using a conventional Z-spray mass spectrometer, we demonstrated reproducible MS detection of peptides and proteins for serial MEA emitters, achieving sensitivity and stability comparable to the commercial capillary emitters. Our robust silicon-based MEA chip opens up the possibility of a fully-integrated microfluidic system for ultrahigh-sensitivity and ultrahigh-throughput proteomics and metabolomics.

47 OTHER INSTRUMENTATION↗

Development of X-ray Wavefront Sensing Techniques for Adaptive Optics Control at the Advanced Photon Source

The planning and construction of new and upgraded high-brightness X-ray synchrotron and free electron laser sources, such as the Advanced Photon Source upgrade project (APS-U), are driving numerous opportunities to advance X-ray science and technologies. At the same time, an increasing number of highly diverse beamline experiments demand wavefront-preserving adaptive X-ray optics with both high precision and flexibility. At the APS, significant effort has been devoted to developing next-generation adaptive and corrective optics combined with state-of-the-art at-wavelength wavefront sensing techniques and an intelligent feedback control system for the automation and self-alignment of beamline optical systems. This article reviews recent achievements in these areas at the APS. Further, these include the development of in-situ wavefront sensing, the application in active feedback control of ultra-precision deformable mirrors, and the exploration of non-invasive wavefront sensing techniques for adaptive optics and beamline diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SILEX experiment system operations

The European Space Agency is going to conduct an inter orbit link experiment which will connect a low Earth orbiting satellite and a Geostationary satellite via optical terminals. This experiment has been called SILEX (Semiconductor Inter satellite Link EXperiment). Two payloads will be built. One called PASTEL (PASsager de TELecommunication) will be embarked on the French Earth observation satellite SPOT4. The future European experimental data relay satellite ARTEMIS (Advanced Relay and TEchnology MISsion) will carry the OPALE terminal (Optical PAyload Experiment). The principal characteristic of the mission is a 50 Megabits flow of data transmitted via the optical satellite link. The relay satellite will route the data via its feeder link thus permitting a real time reception in the European region of images taken by the observation satellite. The PASTEL terminal has been designed to cover up to 9 communication sessions per day with an average of 5. The number of daily contact opportunities with the low earth orbiting satellite will be increased and the duration will be much longer than the traditional passes over a ground station. The terminals have an autonomy of 24 hours with respect to ground control. Each terminal will contain its own orbit model and that of its counter terminal for orbit prediction and for precise computation of pointing direction. Due to the very narrow field of view of the communication laser beam, the orbit propagation calculation needs to be done with a very high accuracy. The European Space Agency is responsible for the operation of both terminals. A PASTEL Mission Control System (PMCS) is being developed to control the PASTEL terminal on board SPOT4. The PMCS will interface with the SPOT4 Control Centre for the execution of the PASTEL operations. The PMCS will also interface with the ARTEMIS Mission Control System for the planning and the coordination of the operation. It is the first time that laser technology will be used to support inter-satellite links in Europe. Due to the complexity and experimental character of this new optical technology, the SILEX experiment control facilities will be designed to allow as much operational flexibility as possible.

Demelenne, B.↗

Feedback-Controlled LED Photobioreactor for Photophysiological Studies of Cyanobacteria

A custom photobioreactor (PBR) was designed to enable automatic light adjustments using computerized feedback control. A black anodized aluminum enclosure, constructed to surround the borosilicate reactor vessel, prevents the transmission of ambient light and serves as a mount for arrays of light-emitting diodes (LEDs). The high-output LEDs provide narrow-band light of either 630 or 680 nm for preferential excitation of the cyanobacterial light-harvesting pigments, phycobilin or chlorophyll a, respectively. Custom developed software BioLume provides automatic control of optical properties and a computer feedback loop can automatically adjust the incident irradiance as necessary to maintain a fixed transmitted light through the culture, based on user-determined set points. This feedback control serves to compensate for culture dynamics which have optical effects, (e.g., changing cell density, pigment adaptations) and thus can determine the appropriate light conditions for physiological comparisons or to cultivate light-sensitive strains, without prior analyses. The LED PBR may also be controlled as a turbidostat, using a feedback loop to continuously adjust the rate of media-dilution based on the transmitted light measurements, with a fast and precise response. This cultivation system gains further merit as a high-performance analytical device, using non-invasive tools (e.g., dissolved gas sensors, online mass spectrometry) to automate real-time measurements, thus permitting unsupervised experiments to search for optimal growth conditions, to monitor physiological responses to perturbations, as well as to quantitate photophysiological parameters using an in situ light-saturation response routine.

controlled cultivation↗