Search NASA⌕ Search

SEARCH · Search NASA

Results for “High resolution data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Remote Radiation Sensing Using Aerial and Ground Platforms

Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-resolution microcalorimeter detectors as a tool in the future of nuclear safeguards

New measurements are presented from the LANL-NIST microcalorimeter array for two standard plutonium sources. The results demonstrate substantially smaller error bars obtained from the spectral analysis program FRAM. Some areas of improvement to the analysis technique have been identified, indicating that the micro calorimeter results can be improved upon. These results support the viability of a device for performing real nuclear safeguards measurements in the near future. The challenge of providing reliably accurate and precise data is a critical component of any safeguards initiative. In the realm of nuclear safeguards, this is an especially daunting task since inaccurate and/or imprecise data could have very serious international consequences. As such, there is a constant drive within the community to establish better measurement and analysis techniques in order to further reduce the associated errors and uncertainties. Even with todays state of the art equipment, measurement uncertainties can extend to several significant quantities worth of material over a relatively modest period of time. Furthermore, there is a strong desire for improved nondestructive analysis techniques in order to reduce both the cost, turnover rate, and inconvenience of destructive analyses. One promising new technology that may help to realize these goals is that of gamma-ray microcalorimeter detectors. The hallmark quality of this new technique is the ability to achieve energy resolution nearly an order of magnitude better than typical planar high-purity germanium (HPGe) detectors. Such an improvement may help reduce uncertainties associated with, for instance, plutonium isotopics or uranium enrichment measurements. This may, in turn, help to reduce uncertainties in total plutonium and/or uranium content in a given sample without the need for destructive analysis. In this paper, we will describe this new detector technology as well as some recent measurements carried out with the LANL-NIST gamma-ray microcalorimeter ({micro}cal) array. Discussion will focus on the capabilities of this technology as well as the progress toward a practical measurement device.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Precession electron diffraction for SiC grain boundary characterization in unirradiated TRISO fuel

Precession electron diffraction (PED), a transmission electron microscopy-based technique, has been evaluated for the suitability for evaluating grain boundary character in the SiC layer of tristructural isotropic (TRISO) fuel. Although the ultimate goal is to determine the grain boundary characteristics of fission product containing grain boundaries of neutron irradiated SiC, our work reports the effect of transmission electron microscope (TEM) lamella thickness on quality of data and establishes a baseline comparison on grain boundary characteristics determined previously using a conventional EBSD scanning electron microscope (SEM) based technique. In general, it was determined that the lamella thickness produced using the standard FIB fabrication process, is sufficient to provide reliable PED measurements with thicker lamellae (~120 nm) produce higher quality orientation data. Analysis of grain boundary character from the TEM-based PED data showed a much lower fraction of low angle grain boundaries compared to SEM-based EBSD data from the SiC layer of the same TRISO-coated particle as well as a SiC layer deposited at a slightly lower temperature. The fractions of high angle and CSL-related grain boundaries determined by PED are similar to those found using SEM-based EBSD. Since the grain size of the SiC layer of TRSIO fuel can be as small as 250 nm [12], depending on the fabrication parameters, and grain boundary fission product precipitates can be nano-sized, the TEM-based PED orientation data collection method is preferred to determine an accurate representation of the relative fractions of low angle, high angle and CSL-related grain boundaries. It was concluded that although the resolution of the PED data is better by more than an order of magnitude, data acquisition times may be significantly longer or the number of areas analyzed significantly larger than the SEM-based method to obtain a statistically relevant distribution. Also, grain size could be accurately determined but significantly larger analysis areas than those used in this study would be required.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Polarimetric Radar Analysis of Ice Microphysical Processes in Melting Layers of Winter Storms Using S-Band Quasi-Vertical Profiles

Quasi-vertical profiles (QVPs) obtained from a database of U.S. WSR-88D data are used to document polarimetric characteristics of the melting layer (ML) in cold-season storms with high vertical resolution and accuracy. A polarimetric technique to define the top and bottom of the ML is first introduced. Using the QVPs, statistical relationships are developed to gain insight into the evolution of microphysical processes above, within, and below the ML, leading to a statistical polarimetric model of the ML that reveals characteristics that reflectivity data alone are not able to provide, particularly in regions of weak reflectivity factor at horizontal polarization Z H . QVP ML statistics are examined for two regimes in the ML data: Z H ≥ 20 dB Z and Z H < 20 dB Z . Regions of Z H ≥ 20 dB Z indicate locations of MLs collocated with enhanced differential reflectivity Z DR and reduced copolar correlation coefficient ρ hv , while for Z H < 20 dB Z a well-defined ML is difficult to discern using Z H alone. Evidence of large Z DR up to 4 dB, backscatter differential phase δ up to 8°, and low ρ hv down to 0.80 associated with lower Z H (from -10 to 20 dB Z ) in the ML is observed when pristine, nonaggregated ice falls through it. Positive correlation is documented between maximum specific differential phase K DP and maximum Z H in the ML; these are the first QVP observations of K DP in MLs documented at S band. Negative correlation occurs between minimum ρ hv in the ML and ML depth and between minimum ρ hv in the ML and the corresponding enhancement of Z H (Δ Z H = Z H max - Z H rain ).

Meteorology & Atmospheric Sciences↗

Comparison of Gafchromic EBT2 and EBT3 for patient-specific quality assurance: Cranial stereotactic radiosurgery using volumetric modulated arc therapy with multiple noncoplanar arcs

Purpose: Patient-specific quality assurance in volumetric modulated arc therapy (VMAT) brain stereotactic radiosurgery raises specific issues on dosimetric procedures, mainly represented by the small radiation fields associated with the lack of lateral electronic equilibrium, the need of small detectors and the high dose delivered (up to 30 Gy). Gafchromic{sup TM} EBT2 and EBT3 films may be considered the dosimeter of choice, and the authors here provide some additional data about uniformity correction for this new generation of radiochromic films.Methods: A new analysis method using blue channel for marker dye correction was proposed for uniformity correction both for EBT2 and EBT3 films. Symmetry, flatness, and field-width of a reference field were analyzed to provide an evaluation in a high-spatial resolution of the film uniformity for EBT3. Absolute doses were compared with thermoluminescent dosimeters (TLD) as baseline. VMAT plans with multiple noncoplanar arcs were generated with a treatment planning system on a selected pool of eleven patients with cranial lesions and then recalculated on a water-equivalent plastic phantom by Monte Carlo algorithm for patient-specific QA. 2D quantitative dose comparison parameters were calculated, for the computed and measured dose distributions, and tested for statistically significant differences.Results: Sensitometric curves showed a different behavior above dose of 5 Gy for EBT2 and EBT3 films; with the use of inhouse marker-dye correction method, the authors obtained values of 2.5% for flatness, 1.5% of symmetry, and a field width of 4.8 cm for a 5 × 5 cm{sup 2} reference field. Compared with TLD and selecting a 5% dose tolerance, the percentage of points with ICRU index below 1 was 100% for EBT2 and 83% for EBT3. Patients analysis revealed statistically significant differences (p < 0.05) between EBT2 and EBT3 in the percentage of points with gamma values <1 (p= 0.009 and p= 0.016); the percent difference as well as the mean difference between calculated and measured isodoses (20% and 80%) were found not to be significant (p= 0.074, p= 0.185, and p= 0.57).Conclusions: Excellent performances in terms of dose homogeneity were obtained using a new blue channel method for marker-dye correction on both EBT2 and EBT3 Gafchromic{sup TM} films. In comparison with TLD, the passing rates for the EBT2 film were higher than for EBT3; a good agreement with estimated data by Monte Carlo algorithm was found for both films, with some statistically significant differences again in favor of EBT2. These results suggest that the use of Gafchromic{sup TM} EBT2 and EBT3 films is appropriate for dose verification measurements in VMAT stereotactic radiosurgery; taking into account the uncertainty associated with Gafchromic film dosimetry, the use of adequate action levels is strongly advised, in particular, for EBT3.

61 RADIATION PROTECTION AND DOSIMETRY↗

Polarization Sensitivity of the DAGATA Polarimeter

In comparison to common Compton Polarimeters the DAGATA (Darmstadt GAmma-ray Tracking Assembly) polarimeter will significantly enhance the sensitivity for gamma-rays above 4 MeV making use of its large volume 36-fold segmented HPGe AGATA crystal and the resulting superior position resolution. Results from Monte Carlo Simulations will be presented as well as approaches for data analysis to further improve the sensitivity. Application limits and realistic simulated spectra will be compared to results from existing polarimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupling of an atmospheric pressure microplasma ionization source with an Orbitrap Fusion Lumos Tribrid 1M mass analyzer for ultra-high resolution isotopic analysis of uranium

The coupling of a combined atomic and molecular (CAM) ionization source, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to an Orbitrap Fusion Lumos Tribrid 1M mass spectrometer is described as a significant step towards the elimination of isobaric interferences in elemental/isotopic mass spectrometry. The developed setup permits broadband, elemental mass spectra to be easily acquired at a mass resolution (m/Δm) of 500 000. A new ion source housing and integrated control system provide enhanced stability and sensitivity of the microplasma ion source in comparison to the previous designs. Detailed evaluation of the ion sampling parameters provided insight into differences with other Orbitrap platforms leading to a 5-fold increase in resolution in elemental/isotopic analysis. The roles of data acquisition/ion processing parameters were evaluated with regards to the precision and accuracy of 235 U/ 238 U isotope ratios. Significantly, the precision of those measurements improves as a function of pre-set mass resolution up to a value of 1 000 000, where a precision of 0.086% RSD is obtained for uranium concentrations of 100 ng mL− 1 . Analytical response curves (log–log), acquired for the two uranium isotopes at a resolution of 120 000 were linear (R 2 = 0.9969) over more than 5 orders of magnitude, with limits of detection of 1 pg mL −1 for U. Based on 60 μL injection volumes, this represents a mass of 70 fg 235 U. These figures of merit satisfy International Target Values (ITVs) for Measurement Uncertainties in Safeguarding Nuclear Materials set by the International Atomic Energy Agency (IAEA). Ultimately, and totally unique from beam-type instruments, the move to the higher-resolution Orbitrap platform provides all of the benefits of high mass resolution, with no penalties in sensitivity, precision, or dynamic range for uranium analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Twentieth Century Reanalysis Project

The Twentieth Century Reanalysis (20CR) project is an international effort to produce a comprehensive global atmospheric circulation dataset spanning the twentieth century, assimilating only surface pressure reports and using observed monthly sea-surface temperature and sea-ice distributions as boundary conditions. It is chiefly motivated by a need to provide an observational dataset with quantified uncertainties for validations of climate model simulations of the twentieth century onall time-scales,with emphasisonthe statistics of daily weather. It uses an Ensemble Kalman Filter data assimilation method with background ‘first guess’ fields supplied by an ensemble of forecasts from a global numerical weather prediction model. This directly yields a global analysis every 6 hours as the most likely state of the atmosphere, and also an uncertainty estimate of that analysis. The 20CR dataset provides the first estimates of global tropospheric variability, and of the dataset’s time-varying quality, from 1871 to the present at 6-hourly temporal and 2° spatial resolutions. Intercomparisons with independent radiosonde data indicate that the reanalyses are generally of high quality. The quality in the extratropical Northern Hemisphere throughout the century is similar to that of current three-day operational NWP forecasts. Intercomparisons over the second half-century of these surface-based reanalyses with other reanalyses that also make use of upper-air and satellite data are equally encouraging. It is anticipated that the 20CR dataset will be a valuable resource to the climate research community for both model validations and diagnostic studies. Some surprising results are already evident. For instance, the long-term trends of indices representing the North Atlantic Oscillation, the tropical Pacific Walker Circulation, and the Pacific–North American pattern are weak or non-existent over the full period of record. The long-term trends of zonally averaged precipitation minus evaporation also differ in character from those in climate model simulations of the twentieth century.

Meteorology & Atmospheric Sciences↗

WMAP five-year constraints on lepton asymmetry and radiation energy density: implications for Planck

In this paper we set bounds on the radiation content of the Universe and neutrino properties by using the WMAP (Wilkinson microwave anisotropy probe) five-year CMB (cosmic microwave background) measurements complemented with most of the existing CMB and LSS (large scale structure) data (WMAP5+All), imposing also self-consistent BBN (big bang nucleosynthesis) constraints on the primordial helium abundance. We consider lepton asymmetric cosmological models parametrized by the neutrino degeneracy parameter {xi}{sub {nu}} and the variation of the relativistic degrees of freedom, {Delta}N{sub eff}{sup oth}, due to possible other physical processes occurring between BBN and structure formation epochs. We get a mean value of the effective number of relativistic neutrino species of N{sub eff} = 2.98 {sub 2.27}{sup 3.60} {sub 1.65}{sup 4.37}, providing an important improvement over the similar result obtained from WMAP5+BAO+SN+HST (BAO: baryonic acoustic oscillations; SN: supernovae; HST: Hubble Space Telescope) data (Komatsu et al (WMAP Collaboration), 2008 Astrophys. J. Suppl. submitted [0803.0547]). We also find a strong correlation between {Omega}{sub m}h{sup 2} and z{sub eq}, showing that we observe N{sub eff} mainly via the effect of z{sub eq}, rather than via neutrino anisotropic stress as claimed by the WMAP team (Komatsu et al (WMAP Collaboration), 2008 Astrophys. J. Suppl. submitted [0803.0547]). WMAP5+All data provide a strong bound on the helium mass fraction of Y{sub p} = 0.2486 {+-} 0.0085 (68% CL), that rivals the bound on Y{sub p} obtained from the conservative analysis of the present data on helium abundance. For the neutrino degeneracy parameter we find a bound of -0.216{<=}{xi}{sub {nu}}{<=}0.226 (68% CL), which represents an important improvement over the similar result obtained by using the WMAP three-year data. The inclusion in the analysis of LSS data reduces the upper limit of the neutrino mass to m{sub {nu}}<0.46 eV (95% CL) with respect to the values obtained from the analysis from WMAP5-only data (Dunkley et al (WMAP Collaboration), 2008 Astrophys. J. Suppl. submitted [0803.0586]) and WMAP5+BAO+SN+HST data (Komatsu et al (WMAP Collaboration), 2008 Astrophys. J. Suppl. submitted [0803.0547]). We forecast that the CMB temperature and polarization measurements observed with high angular resolutions and sensitivities by the future Planck satellite will reduce the errors on {xi}{sub {nu}} and Y{sub p} down to {sigma}({xi}{sub {nu}}){approx_equal}0.089 (68% CL) and {sigma}(Y{sub p}) = 0.013 (68% CL) respectively, values fully consistent with the BBN bounds on these parameters. This work has been done on behalf of Planck-LFI (low frequency instrument) activities.

79 ASTRONOMY AND ASTROPHYSICS↗

Molecular Breast Imaging Using Emission Tomosynthesis

Purpose: Tour objective is to design a novel SPECT system for molecular breast imaging (MBI) and evaluate its performance. The limited angle SPECT system, or emission tomosynthesis, is designed to achieve 3D images of the breast with high spatial resolution/sensitivity. The system uses a simplified detector motion and is conducive to on-board biopsy and mult-modal imaging with mammography. Methods: The novel feature of the proposed gamma camera is a variable-angle, slant-hole (VASH) collimator, which is well suited for limited angle SPECT of a mildly compressed breast. The collimator holes change slant angle while the camera surface remains flush against the compression paddle. This allows the camera to vary the angular view ({+-}30{degrees}, {+-}45{degrees}) for tomographic imaging while keeping the camera close to the object for high spatial resolution and/or sensitivity. Theoretical analysis and Monte Carlo simulations were performed assuming a point source and isolated breast phantom. Spatial resolution, sensitivity, contrast and SNR were measured. Results were compared to single-view, planar images and conventional SPECT. For both conventional SPECT and VASH, data were reconstructed using iterative algorithms. Finally, a proof-of-concept VASH collimator was constructed for experimental evaluation. Results: Measured spatial resolution/sensitivity with VASH showed good agreement with theory including depth-of-interaction (DOI) effects. The DOI effect diminished the depth resolution by approximately 2 mm. Increasing the slant angle range from {+-}30{degrees} to {+-}45{degrees} resulted in an approximately 1 mm improvement in the depth resolution. In the breast phantom images, VASH showed improved contrast and SNR over conventional SPECT and improved contrast over planar scintimmammography. Reconstructed images from the proof-of-concept VASH collimator demonstrated reasonable depth resolution capabilities using limited angle projection data. Conclusion: We conclude that this limited angle SPECT approach using a VASH collimator can achieve superior 3D image quality for MBI in a design that has attractive characteristics for clinical imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ↗

Morphological Properties of the Crab Nebula: A Detailed Multiwavelength Study Based on New VLA, HST, Chandra, and XMM-Newton Images

We present a detailed analysis of the morphological properties of the Crab Nebula across the electromagnetic spectrum based on new and previous high-quality data from radio to X-rays. In the radio range we obtained an image of the entire nebula at 3 GHz with subarcsecond angular resolution using the VLA (NRAO) and an image at 100 GHz of the central region using the ALMA array. Simultaneously with the VLA observations we performed HST WFPC3 near-infrared (λ∼1.5 μm) and Chandra X-ray (0.5–8 keV band) observations of the central region of the nebula. In addition we produced a new UV image of the Crab Nebula at 291 nm by co-adding 75 individual exposures of the Optical-UV Monitor on board XMM-Newton. The high-angular resolution and high-dynamic range radio image at 3 GHz allowed us to improve the detection and characterization of peculiar morphological features including arches with foot brightening and intercrossed loop-like structures, likely originating in plasma confined to magnetic field lines. Based on the new radio image, we carried out a detailed multiwavelength correlation. In the central area, the comparison of the almost simultaneous images confirms that the wisps in the three spectral ranges do not generally coincide in location, the radio emission being the most discordant, which is suggestive of the existence of two different synchrotron components. The X-ray pulsar jet does not have a radio counterpart. Instead, another jet-like feature is seen in radio, though with different curvature and starting point.

79 ASTRONOMY AND ASTROPHYSICS↗

Virgo Redux: The Masses and Stellar Content of Nuclei in Early-type Galaxies from Multiband Photometry and Spectroscopy

We present an analysis of 39 nuclei and their early-type hosts in the Virgo Cluster using 10 broadband filters: F300W, F475W, F850LP, F160W, u{sup ∗}griz, and K {sub s}. We describe the Virgo Redux program, which provides high-resolution UV and NIR imaging. Combining this data with optical and NIR imaging from the ACS Virgo Cluster Survey and the Next Generation Virgo Cluster Survey, we estimate masses, metallicities, and ages using simple stellar population (SSP) models. For 19 nuclei, we compare to SSP parameters derived from Keck and Gemini spectra and find reasonable agreement between the photometric and spectroscopic metallicity: the rms scatter is 0.3 dex. We reproduce the nucleus–galaxy mass fraction of 0.33{sub −0.07}{sup +0.09}% for galaxy stellar masses 10{sup 8.4}--10{sup 10.3} M{sub ⊙} with a typical precision of ∼35% for the nuclei masses. Based on available model predictions, there is no single preferred formation scenario for nuclei, suggesting that nuclei are formed stochastically through a mix of processes. Nuclei metallicities are statistically identical to those of their hosts, appearing 0.07 ± 0.3 dex more metal-rich on average; however, omitting galaxies with unusual origins, nuclei are 0.20 ± 0.28 dex more metal-rich. Nuclei appear to be 0.56 ± 0.12 dex more metal-rich than ultracompact dwarf galaxies (UCDs) at fixed mass. We find no clear age difference between nuclei and their galaxies, with nuclei displaying a broad range of ages. Interestingly, we find that the most massive nuclei may be flatter and more closely aligned with the semimajor axes of their hosts, suggesting that they formed through predominantly dissipative processes.

79 ASTRONOMY AND ASTROPHYSICS↗

Wind Energy Accomplishments and Year-End Performance Report: Fiscal Year 2022

Four decades ago, construction was just beginning on experimental turbines at the National Wind Technology Center (NWTC). Today, the U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory (NREL) facility is the centerpiece of the laboratory's Flatirons Campus, a world-class hub for renewable energy research. The nation's shift to 100% clean electricity by 2035 will require a mix of renewable energy sources and strategies - and together, wind and solar energy could account for 60% to 80% of that clean energy resource. In Fiscal Year (FY) 2022, NREL scientists, engineers, and analysts contributed to these visionary goals through their wind energy research. As wind innovations push into new areas, NREL continues to play a vital role in advancing technology and addressing deployment barriers in pursuit of more efficient, reliable, and predictable wind energy systems. FY 2022 wind research and development explored the potential for dramatic growth in land-based systems, the launch of the nation's first commercial-scale offshore installations, and transmission infrastructure buildout. Land-based wind energy is one of the most cost-effective electricity supply options - but utility-scale deployment will require up to 10 times the current number of turbines. An NREL plan addressed this need to accelerate U.S. wind technology rollout at distributed and utility scales. Another project conducted by NREL and the Pacific Northwest National Laboratory (PNNL) helps position the nation's first major offshore wind corridor for success. The WETO-funded Atlantic Offshore Wind Transmission Study is evaluating options for balancing electricity supply and demand, while supporting resilience of the grid and marine industries. WETO, NREL, and other partners are working to enable the enormous supply chain and workforce changes the U.S. wind energy industry will need to meet net-zero-carbon-emissions targets. As part of a seminal series of DOE-funded supply chain studies, NREL analysts reported on the trade-offs involved in manufacturing large volumes of wind technologies, while addressing cost, workforce, and logistics issues. All of this research is supported by NREL's outstanding research teams, tools, data, and facilities. A WETO-funded international wind energy field campaign, the American WAKE experimeNt (AWAKEN), has brought together experts from NREL, PNNL, and Sandia National Laboratories to create the world's most comprehensive set of high-resolution data on wind energy atmospheric phenomenon. This study could lead to more accurate predictions of losses from turbine-to-turbine wake interactions, eventually helping wind plants capture more energy and operators save millions of dollars. In addition, NREL researchers developed testing, modeling, and analysis tools to improve the security of power grids by identifying wind power plant dynamic stability problems. A new Stochastic Soaring Raptor Simulator (SSRS) protects golden eagles from turbine encounters by predicting flight paths. This report provides more detail on these top achievements and other accomplishments made by NREL and its partners during FY 2022 (between October 1, 2021, and September 30, 2022).

accomplishments↗

Measurement and Modeling of Density-Sensitive Lines of Fe XIII in the Extreme Ultraviolet

We present an analysis of the spectral emission of Fe XIII near 200 {angstrom}. High resolution spectra were recorded at two densities ({approx} x 10{sup 11} and {approx} 10{sup 13} cm{sup -3}) in the laboratory and compared to collisional radiative model calculations based on the CHIANTI data base as well as to models using atomic data from distorted-wave and R-matrix calculations. The Fe XIII lines in this wavelength range are sensitive indicators of plasma density below {approx} 10{sup 11} cm{sup -3}. The laboratory data thus test the calculations in the astrophysically high-density limit. Significant differences between the measurements and models were found for several line ratios. Differences in the wavelengths employed in the different models also changed the agreement with the measurements. Best agreement was found in the comparisons with CHIANTI.

74 ATOMIC AND MOLECULAR PHYSICS↗

Wave climate and energy resources in American Samoa from a 42-year high-resolution hindcast

Here, this paper presents an analysis of the wave climate and a characterization of the wave energy resources in American Samoa, a U.S. territory covering seven south central Pacific islands and atolls. A numerical wave model based on WAVEWATCH III® and unstructured SWAN was developed, validated, and executed for 1979–2020 to generate a hindcast dataset suitable for resource characterization. Model-data comparisons were performed with measurements collected in situ and from satellite-based altimeters. The model was found to perform well with a bias in significant wave height of -0.14 m and -0.06 m against buoy and altimeters, respectively. The multimodal sea state of American Samoa is investigated by identifying the sources of energy reaching the islands and partitioning the wave spectrum accordingly. The wave resources characterization follows the International Electrotechnical Commission Technical Specifications to be compatible with studies performed for other U.S. regions. The average omnidirectional wave power at 2 km from shore around Tutuila, the main island of American Samoa, is 14 kW/m. Locations east and west of the islands have a more consistent resource throughout the year because the northwest and southwest swells that are dominant during different seasons complement each other.

16 TIDAL AND WAVE POWER↗

A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct prediction of inelastic neutron scattering spectra from the crystal structure*

Abstract Inelastic neutron scattering (INS) is a powerful technique to study vibrational dynamics of materials with several unique advantages. However, analysis and interpretation of INS spectra often require advanced modeling that needs specialized computing resources and relevant expertise. This difficulty is compounded by the limited experimental resources available to perform INS measurements. In this work, we develop a machine-learning based predictive framework which is capable of directly predicting both one-dimensional INS spectra and two-dimensional INS spectra with additional momentum resolution. By integrating symmetry-aware neural networks with autoencoders, and using a large scale synthetic INS database, high-dimensional spectral data are compressed into a latent-space representation, and a high-quality spectra prediction is achieved by using only atomic coordinates as input. Our work offers an efficient approach to predict complex multi-dimensional neutron spectra directly from simple input; it allows for improved efficiency in using the limited INS measurement resources, and sheds light on building structure-property relationships in a variety of on-the-fly experimental data analysis scenarios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗