Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Real-time observation of valence electron motion.

The superposition of quantum states drives motion on the atomic and subatomic scales, with the energy spacing of the states dictating the speed of the motion. In the case of electrons residing in the outer (valence) shells of atoms and molecules which are separated by electronvolt energies, this means that valence electron motion occurs on a subfemtosecond to few-femtosecond timescale (1 fs = 10{sup -15} s). In the absence of complete measurements, the motion can be characterized in terms of a complex quantity, the density matrix. Here we report an attosecond pump-probe measurement of the density matrix of valence electrons in atomic krypton ions. We generate the ions with a controlled few-cycle laser field and then probe them through the spectrally resolved absorption of an attosecond extreme-ultraviolet pulse, which allows us to observe in real time the subfemtosecond motion of valence electrons over a multifemtosecond time span. We are able to completely characterize the quantum mechanical electron motion and determine its degree of coherence in the specimen of the ensemble. Although the present study uses a simple, prototypical open system, attosecond transient absorption spectroscopy should be applicable to molecules and solid-state materials to reveal the elementary electron motions that control physical, chemical and biological properties and processes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Near Discharge Cathode Assembly Plasma Potential Measurements in a 30-cm NSTAR Type Ion Engine During Beam Extraction

Floating emissive probe plasma potential data are presented over a two-dimensional array of locations in the near Discharge Cathode Assembly (DCA) region of a 30-cm diameter ring-cusp ion thruster. Discharge plasma data are presented with beam extraction at throttling conditions comparable to the NASA TH Levels 8, 12, and 15. The operating conditions of the Extended Life Test (ELT) of the Deep Space One (DS1) flight spare ion engine, where anomalous discharge keeper erosion occurred, were TH 8 and TH 12 consequently they are of specific interest in investigating discharge keeper erosion phenomena. The data do not validate the presence of a potential hill plasma structure downstream of the DCA, which has been proposed as a possible erosion mechanism. The data are comparable in magnitude to data taken by other researchers in ring-cusp electron-bombardment ion thrusters. The plasma potential structures are insensitive to thruster throttling level with a minimum as low as 14 V measured at the DCA exit plane and increasing gradually in the axial direction. A sharp increase in plasma potential to the bulk discharge value of 26 to 28 volts, roughly 10 mm radially from DCA centerline, was observed. Plasma potential measurements indicate a low-potential plume structure that is roughly 20 mm in diameter emanating from the discharge cathode that may be attributed to a free-standing plasma double layer.

Herman, Daniel A.↗

EMIC Wave Scale Size in the Inner Magnetosphere: Observations From the Dual Van Allen Probes

Estimating the spatial scales of electromagnetic ion cyclotron (EMIC) waves is critical for quantifying their overall scattering efficiency and effects on thermal plasma, ring current, and radiation belt particles. Using measurements from the dual Van Allen Probes in 2013-2014, we characterize the spatial and temporal extents of regions of EMIC wave activity and how these depend on local time and radial distance within the inner magnetosphere. Observations are categorized into three types: waves observed by only one spacecraft, waves measured by both spacecraft simultaneously, and waves observed by both spacecraft with some time lag. Analysis reveals that dayside (and H+ band) EMIC waves more frequently span larger spatial areas, while nightside (and He+ band) waves are more often localized but can persist many hours. These investigations give insight into the nature of EMIC wave generation and support more accurate quantification of their effects on the ring current and outer radiation belt.

Blum, L. W.↗

Vibrational dynamics of aqueous hydroxide solutions probed using broadband 2DIR spectroscopy

We employed ultrafast transient absorption and broadband 2DIR spectroscopy to study the vibrational dynamics of aqueous hydroxide solutions by exciting the O–H stretch vibrations of the strongly hydrogen-bonded hydroxide solvation shell water and probing the continuum absorption of the solvated ion between 1500 and 3800 cm{sup −1}. We observe rapid vibrational relaxation processes on 150–250 fs time scales across the entire probed spectral region as well as slower vibrational dynamics on 1–2 ps time scales. Furthermore, the O–H stretch excitation loses its frequency memory in 180 fs, and vibrational energy exchange between bulk-like water vibrations and hydroxide-associated water vibrations occurs in ∼200 fs. The fast dynamics in this system originate in strong nonlinear coupling between intra- and intermolecular vibrations and are explained in terms of non-adiabatic vibrational relaxation. These measurements indicate that the vibrational dynamics of the aqueous hydroxide complex are faster than the time scales reported for long-range transport of protons in aqueous hydroxide solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Examining Interactions of Uranyl(VI) Ions with Amino Acids in the Gas Phase

Gas-phase experiments, using electrospray ionization quadrupole ion trap mass spectrometry (ESI-QIT/MS), were conducted to probe basic interactions of the uranyl(VI) ion, UO 2 2+ , with selected natural amino acids, namely, L-cysteine (Cys), L-histidine (His), and L-aspartic acid (Asp), which strongly bind to metal ions. The simplest amino acid, glycine (Gly), was also studied for comparison. Cys, His, and Asp have additional potentially coordinating groups beyond the amino and carboxylic acid functional groups, specifically thiol in Cys, imidazole in His, and a second carboxylate in Asp. Gas-phase experiments comprised collision-induced dissociation (CID) of uranyl–amino acid complexes and competitive CID to assess the relative binding strength of different amino acids in the same uranyl complex. Reactivity of selected uranyl–amino acid complexes with water provided further insights into relative stabilities. In positive ion mode, CID and ensuing reactions with water suggested that uranyl–neutral AA binding strength decreased in the order His > Asp > Cys > Gly, which is similar to amino acid proton affinities. In negative ion mode, CID revealed a decreasing dissociation tendency in the order Gly >> His ≈ Cys > Asp, presumably reflecting a reverse enhanced binding to uranyl of the doubly deprotonated amino acids formed in CID.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sputtering-induced vacancy cluster formation on TiO{sub 2}(110)

Defects are introduced on an atomically clean TiO{sub 2}(110) surface in a controllable manner via bombardment by 0.5 keV Ar{sup +} ions, and the resultant material is probed with scanning tunneling microscopy and x-ray photoelectron spectroscopy. It is shown that ion bombardment leads to a change of stoichiometry and the formation of vacancy clusters, while annealing after prolonged bombardment forms regular rectangular cavities with single-atomic-layer steps. It is concluded that curvature-dependent sputtering in combination with adatom and vacancy diffusion is responsible for the observed structures.

36 MATERIALS SCIENCE↗

Investigation of ion kinetic effects in direct-drive exploding-pusher implosions at the NIF

Measurements of yield, ion temperature, areal density (rhoR), shell convergence, and bang time have been obtained in shock-driven, D2 and D3He gas-filled “exploding-pusher” inertial confinement fusion (ICF) implosions at the National Ignition Facility (NIF) to assess the impact of ion kinetic effects. These measurements probed the shock convergence phase of ICF implosions, a critical stage in hot-spot ignition experiments. The data complement previous studies of kinetic effects in shock-driven implosions. Ion temperature and fuel rhoR inferred from fusion-product spectroscopy are used to estimate the ion-ion mean free path in the gas. A trend of decreasing yields relative to the predictions of 2D draco hydrodynamics simulations with increasing Knudsen number (the ratio of ion-ion mean free path to minimum shell radius) suggests that ion kinetic effects are increasingly impacting the hot fuel region, in general agreement with previous results. The long mean free path conditions giving rise to ion kinetic effects in the gas are often prevalent during the shock phase of both exploding pushers and ablatively-driven implosions, including ignition-relevant implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Ion Collective Thomson Scattering Diagnostic for ITER - Progress of Design

In the era of high power and burning plasma fusion experiments with significant populations of fast particles, the diagnosis of fast ion dynamics becomes an important topic. In ITER, populations of fast ions due to ICRH and NBI, as well as fusion born alphas will carry a significant fraction of the free energy of the plasma. This may affect instabilities and transport in the plasma. A key candidate for diagnosing confined fast ions in ITER is the technique of collective Thomson scattering (CTS). A fast ion CTS system with a probing frequency of 60 GHz has been proposed for ITER. Based on diagnostic experience from particularly TEXTOR and ASDEX Upgrade, work is now progressing towards a final design of a fast ion CTS diagnostic for ITER. The biggest challenge of the diagnostic design is the HFS receiver located in the restricted space behind the blanket modules. Calculations and a series of mock-up measurements have brought the design towards a four mirror quasi-optical solution. The development as well as the present design will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of Beam Ion Loss from the Compact Helical System

Beam ion loss from the Compact Helical System (CHS) has been measured with a scintillator-type probe. The total loss to the probe, and the pitch angle and gyroradius distributions of that loss, have been measured as various plasma parameters were scanned. Three classes of beam ion loss were observed at the probe position: passing ions with pitch angles within 10o of those of transition orbits, ions on transition orbits, and ions on trapped orbits, typically 15o or more from transition orbits. Some orbit calculations in this geometry have been performed in order to understand the characteristics of the loss. Simulation of the detector signal based upon the following of orbits from realistic beam deposition profiles is not able to reproduce the pitch angle distribution of the losses measured. Consequently it is inferred that internal plasma processes, whether magnetohydrodynamic modes, radial electric fields, or plasma turbulence, move previously confined beam ions to transition orbits, resulting in their loss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Modification and Chemical Sputtering of Graphite Induced by Low Energy Atomic and Molecular Deuterium Ions

The surface morphology, and chemical/structural modifications induced during chemical sputtering of ATJ graphite by low-energy (<200 eV/D) deuterium atomic and molecular ions are explored by Scanning Electron Microscopy (SEM), Raman and Auger Electron Spectroscopy (AES) diagnostics. At the lowest impact energies, the ion range may become less than the probe depth of Raman and AES spectroscopy diagnostics. We show that such diagnostics are still useful probes at these energies. As demonstration, we used these surface diagnostics to confirm the characteristic changes of surface texture, increased amorphization, enhanced surface reactivity to impurity species, and increased sp{sup 3} content that low-energy deuterium ion bombardment to steady-state chemical sputtering conditions produces. To put these studies into proper context, we also present new chemical sputtering yields for methane production of ATJ graphite at room temperature by impact of D{sub 2}{sup +} in the energy range 10-250 eV/D, and by impact of D{sup +} and D{sub 3}{sup +} at 30 eV/D and 125 eV/D, obtained using a Quadrupole Mass Spectroscopy (QMS) approach. Below 100 eV/D, the methane production in ATJ graphite is larger than that in HOPG by a factor of {approx} 2. In the energy range 10-60 eV/D, the methane production yield is almost independent of energy and then decreases with increasing ion energies. The results are in good agreement with recent molecular dynamics simulations.

03 NATURAL GAS↗

Revisiting plasma hysteresis with an electronically compensated Langmuir probe

The measurement of electron temperature in plasma by Langmuir probes, using ramped bias voltage, is seriously affected by the capacitive current of capacitance of the cable between the probe tip and data acquisition system. In earlier works a dummy cable was used to balance the capacitive currents. Under these conditions, the measured capacitive current was kept less than a few mA. Such probes are suitable for measurements in plasma where measured ion saturation current is of the order of hundreds of mA. This paper reports that controlled balancing of capacitive current can be minimized to less than 20 {mu}A, allowing plasma measurements to be done with ion saturation current of the order of hundreds of {mu}A. The electron temperature measurement made by using probe compensation technique becomes independent of sweep frequency. A correction of {<=}45% is observed in measured electron temperature values when compared with uncompensated probe. This also enhances accuracy in the measurement of fluctuation in electron temperature as {delta}T{sub pk-pk} changes by {approx}30%. The developed technique with swept rate {<=}100 kHz is found accurate enough to measure both the electron temperature and its fluctuating counterpart. This shows its usefulness in measuring accurately the temperature fluctuations because of electron temperature gradient in large volume plasma device plasma with frequency ordering {<=}50 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of ion source characterization diagnostics in INTF

INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lidar Probing of the Mesosphere: Simultaneous Observations of Sporadic Sodium and Iron Formations, Calcium Ion Layers, Neutral Temperature and Winds

Meteoritic ablation in the upper atmosphere is the commonly accepted source of the mesospheric metals between 80 and 105 km. The vertical and temporal behavior of some of these metals can be probed with high accuracy and resolution using resonance fluorescence lidar techniques. Of considerable interest in recent years has been the sporadic and rapid formation of thin, dense enhancements in these metallic layers. Since late Mar. 1991, the UIUC CEDAR lidar system, located at the Urbana Atmospheric Observatory, has been routinely operating at the Fe resonance line of 372 nm in order to probe the mesospheric Fe layer. In Nov. 1991, the capability to investigate mesospheric Ca(+) at the resonance line of 393.4 nm was added. The lidar's eximer-pumped dye laser uses Exciton QUI laser dye dissolved in p-dioxane, which can lase at both the Fe and Ca(+) frequencies. Various aspects of this investigation are discussed.

Kane, Timothy J.↗

An inverted cylindrical sputter magnetron as metal vapor supply for electron cyclotron resonance ion sources

An inverted cylindrical sputter magnetron device has been developed. The magnetron is acting as a metal vapor supply for an electron cyclotron resonance (ECR) ion source. FEM simulation of magnetic flux density was used to ensure that there is no critical interaction between both magnetic fields of magnetron and ECR ion source. Spatially resolved double Langmuir probe and optical emission spectroscopy measurements show an increase in electron density by one order of magnitude from 1 × 10{sup 10} cm{sup −3} to 1 × 10{sup 11} cm{sup −3}, when the magnetron plasma is exposed to the magnetic mirror field of the ECR ion source. Electron density enhancement is also indicated by magnetron plasma emission photography with a CCD camera. Furthermore, photographs visualize the formation of a localized loss-cone - area, when the magnetron is operated at magnetic mirror field conditions. The inverted cylindrical magnetron supplies a metal atom load rate of R > 1 × 10{sup 18} atoms/s for aluminum, which meets the demand for the production of a milliampere Al{sup +} ion beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature Dependence of Plasmaspheric Ion Composition

We assess a database of Dynamics Explorer-1 (DE-1) Retarding Ion Mass Spectrometer densities and temperatures to yield the first explicit measure of how cold ion concentration depends on temperature. We discover that cold H + and He + concentrations have very weak dependence on temperature, but cold O+ ion concentration increases steeply as these ions become warmer. We exhibit how this result can aid in analyzing composition data from other satellites without spacecraft potential mitigation, by applying the result to an example using data from the Van Allen Probes mission. Measurement of light ion concentrations above 1 electron volt (eV) are a reasonable proxy for the concentrations of colder (eV) ions. Warmer O + ion concentrations may be extrapolated to colder temperatures using our fit to the statistical distribution versus temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current Density Measurements of an Annular-Geometry Ion Engine

The concept of the annular-geometry ion engine, or AGI-Engine, has been shown to have many potential benefits when scaling electric propulsion technologies to higher power. However, the necessary asymmetric location of the discharge cathode away from thruster centerline could potentially lead to non-uniformities in the discharge not present in conventional geometry ion thrusters. In an effort to characterize the degree of this potential nonuniformity, a number of current density measurements were taken on a breadboard AGI-Engine. Fourteen button probes were used to measure the ion current density of the discharge along a perforated electrode that replaced the ion optics during conditions of simulated beam extraction. Three Faraday probes spaced apart in the vertical direction were also used in a separate test to interrogate the plume of the AGI-Engine during true beam extraction. It was determined that both the discharge and the plume of the AGI-Engine are highly uniform, with variations under most conditions limited to 10% of the average current density in the discharge and 5% of the average current density in the plume. Beam flatness parameter measured 30 mm from the ion optics ranged from 0.85 0.95, and overall uniformity was shown to generally increase with increasing discharge and beam currents. These measurements indicate that the plasma is highly uniform despite the asymmetric location of the discharge cathode.

Shastry, Rohit↗

Nanoscale view of assisted ion transport across the liquid–liquid interface

During solvent extraction, amphiphilic extractants assist the transport of metal ions across the liquid–liquid interface between an aqueous ionic solution and an organic solvent. Investigations of the role of the interface in ion transport challenge our ability to probe fast molecular processes at liquid–liquid interfaces on nanometer-length scales. Recent development of a thermal switch for solvent extraction has addressed this challenge, which has led to the characterization by X-ray surface scattering of interfacial intermediate states in the extraction process. Here, we review and extend these earlier results. We find that trivalent rare earth ions, Y(III) and Er(III), combine with bis(hexadecyl) phosphoric acid (DHDP) extractants to form inverted bilayer structures at the interface; these appear to be condensed phases of small ion–extractant complexes. The stability of this unconventional interfacial structure is verified by molecular dynamics simulations. The ion–extractant complexes at the interface are an intermediate state in the extraction process, characterizing the moment at which ions have been transported across the aqueous–organic interface, but have not yet been dispersed in the organic phase. In contrast, divalent Sr(II) forms an ion–extractant complex with DHDP that leaves it exposed to the water phase; this result implies that a second process that transports Sr(II) across the interface has yet to be observed. Calculations demonstrate that the budding of reverse micelles formed from interfacial Sr(II) ion–extractant complexes could transport Sr(II) across the interface. Our results suggest a connection between the observed interfacial structures and the extraction mechanism, which ultimately affects the extraction selectivity and kinetics.

Liang, Zhu↗

ENERGETIC PARTICLE ANISOTROPIES AT THE HELIOSPHERIC BOUNDARY

In 2012 August the Voyager 1 space probe entered a distinctly new region of space characterized by a virtual absence of heliospheric energetic ions and magnetic fluctuations, now interpreted as a part of the local interstellar cloud. Prior to their disappearance, the ion distributions strongly peaked at a 90° pitch angle, implying rapid escape of streaming particles along the magnetic field lines. Here we investigate the process of particle crossing from the heliosheath into the interstellar space, using a kinetic approach that resolves scales of the particle's cyclotron radius and smaller. It is demonstrated that a 'pancake' pitch-angle distribution naturally arises at a tangential discontinuity separating a weakly turbulent plasma from a laminar region with a very low pitch-angle scattering rate. The relatively long persistence of gyrating ions is interpreted in terms of field line meandering facilitating their cross-field diffusion within the depletion region.

79 ASTRONOMY AND ASTROPHYSICS↗