Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Real time observation of binder jetting printing process using high-speed X-ray imaging

A high-speed synchrotron X-ray imaging technique was used to investigate the binder jetting additive manufacturing (AM) process. A commercial binder jetting printer with droplet-on-demand ink-jet print-head was used to print single lines on powder beds. The printing process was recorded in real time using high-speed X-ray imaging. The ink-jet droplets showed distinct elongated shape with spherical head, long tail, and three to five trailing satellite droplets. Significant drift was observed between the impact points of main droplet and satellite droplets. The impact of the droplet on the powder bed caused movement and ejection of the powder particles. The depth of disturbance in the powder bed from movement and ejection was defined as interaction depth, which is found to be dependent on the size, shape, and material of the powder particles. For smaller powder particles (diameter less than 10 μm), three consecutive binder droplets were observed to coalesce to form large agglomerates. As a result, the observations reported here will facilitate the understanding of underlying physics that govern the binder jetting processes, which will then help in improving the quality of parts manufactured using this AM process.

42 ENGINEERING↗

Characterization of Reactant Mixing in a Rotating Detonation Engine Using Schlieren Imaging and Planar Laser Induced Fluorescence

A linearized version of an axial flow injector used in an air breathing rotating detonation engine (RDE) has been developed to aid in the study of reactant mixing. The test bed was designed with optical access so that a variety of qualitative and quantitative imaging techniques may be applied. Non-reacting, pure mixing studies are presented here. In this initial study high speed Schlieren video is used to understand the evolution of the flow field in time and across an operating regime analogous to its RDE counterpart. Basic flow features are identified and average flow field images are generated and used to assess how the average flow field evolves across the operating regime. Acetone-tracer planar laser induced fluorescence (PLIF) is used to generate plots of instantaneous and average molar fraction and initial data is presented here.

Duvall, James↗

Ultrasonic NDE of structural ceramics for power and propulsion systems

A review of research investigations of several ultrasonic evaluation techniques applicable to structural ceramics for advanced heat engines is presented. This review highlights recent work conducted under the sponsorship of and at the Lewis Research Center. Results obtained with scanning acoustic microscopy, scanning laser acoustic microscopy, photo acoustic microscopy, and scanning electron acoustic microscopy are compared. In addition to these flaw imaging techniques, microstructure characterization by analytical ultrasonics is described. The techniques were evaluated by application to research samples of monolithic silicon nitride and silicon carbide in the form of discs and bars containing naturally occurring and deliberately-introduced flaws and microstructural anomalies. Strengths and limitations of the techniques are discussed.

Vary, Alex↗

An Off-Axis Four-Quadrant Phase Mask (FQPM) Coronagraph for Palomar: High-Contrast Near Bright Stars Imager

Direct detection of planets around nearby stars requires the development of high-contrast imaging techniques because of the high difference between their respective fluxes. This led us to test a new coronagraphic approach based on the use of phase mask instead of dark occulting ones. Combined with high-level wavefront correction on an unobscured off-axis section of a large telescope, this method allows imaging very close to the star. Calculations indicate that for a given ground-based on-axis telescope, use of such an off-axis coronagraph provides a near-neighbor detection capability superior to that of a traditional coronagraph utilizing the full telescope aperture. Setting up a laboratory experiment working in near infrared allowed us to demonstrate the principle of the method, and a rejection of 2000:1 has already been achieved.

coronagraphy↗

Structure of the runaway electron loss during induced disruptions in TEXTOR

The loss of runaway electrons during an induced disruption is recorded by a synchrotron imaging technique using a fast infrared CCD camera. The loss is predominantly diffuse. During the “spiky-loss phase”, when the runaway beam moves close to the wall, a narrow channel between the runaway column and a scintillator probe is formed and lasts until the runaway beam is terminated. In some cases, the processed images show a stripe pattern at the plasma edge. A comparison between the MHD dominated disruptions and the MHD-free disruption is performed. A new mechanism of plasma disruptions with the runaway electron generation and a novel model which reproduces many characteristic features of the plasma beam evolution during a disruption is briefly described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of Femtosecond Laser Ablation Plume Studied With Ultrafast X-ray Absorption Fine Structure Imaging

We investigated the dynamic process of an expanding femtosecond laser ablation plume of aluminum generated in an irradiation intensity range of 10{sup 13}-10{sup 15} W/cm{sup 2} with the ultrafast x-ray absorption fine structure (XAFS) imaging technique. The XAFS spectra of the aluminum L{sub II,III} edge of the plume revealed that the plume consists of doubly and singly charged ions, neutral atoms, liquid particles, and possible atomic clusters. Scanning electron microscopy of deposited ablation particles confirmed that the liquid particles corresponds to the spherical nanoparticles with a size ranging from several tens nanometers to approximately 200 nm. The spatiotemporal evolution of the XAFS image of the plume shows the sequential appearance of each ablation particle from aluminum surface according to its ejection velocity. The result suggests that the photomechanical fragmentation process, which was theoretically proposed, is dominant mechanism for the nanoparticle ejection under the irradiation intensity far from the ablation threshold of aluminum. This study clearly demonstrates the potential of our technique for measuring the ultrafast dynamics of femtosecond laser ablation process.

36 MATERIALS SCIENCE↗

Validation of Imaging With Pathology in Laryngeal Cancer: Accuracy of the Registration Methodology

Purpose: To investigate the feasibility and accuracy of an automated method to validate gross tumor volume (GTV) delineations with pathology in laryngeal and hypopharyngeal cancer. Methods and Materials: High-resolution computed tomography (CT{sub HR}), magnetic resonance imaging (MRI), and positron emission tomography (PET) scans were obtained from 10 patients before total laryngectomy. The GTV was delineated separately in each imaging modality. The laryngectomy specimen was sliced transversely in 3-mm-thick slices, and whole-mount hematoxylin-eosin stained (H and E) sections were obtained. A pathologist delineated tumor tissue in the H and E sections (GTV{sub PATH}). An automatic three-dimensional (3D) reconstruction of the specimen was performed, and the CT{sub HR}, MRI, and PET were semiautomatically and rigidly registered to the 3D specimen. The accuracy of the pathology-imaging registration and the specimen deformation and shrinkage were assessed. The tumor delineation inaccuracies were compared with the registration errors. Results: Good agreement was observed between anatomical landmarks in the 3D specimen and in the in vivo images. Limited deformations and shrinkage (3% {+-} 1%) were found inside the cartilage skeleton. The root mean squared error of the registration between the 3D specimen and the CT, MRI, and PET was on average 1.5, 3.0, and 3.3 mm, respectively, in the cartilage skeleton. The GTV{sub PATH} volume was 7.2 mL, on average. The GTVs based on CT, MRI, and PET generated a mean volume of 14.9, 18.3, and 9.8 mL and covered the GTV{sub PATH} by 85%, 88%, and 77%, respectively. The tumor delineation inaccuracies exceeded the registration error in all the imaging modalities. Conclusions: Validation of GTV delineations with pathology is feasible with an average overall accuracy below 3.5 mm inside the laryngeal skeleton. The tumor delineation inaccuracies were larger than the registration error. Therefore, an accurate histological validation of anatomical and functional imaging techniques for GTV delineation is possible in laryngeal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental analysis on the effects of DC arc discharges at various flow regimes

This paper addresses the control of the boundary layer on a compression ramp by means of DC electrical arc discharges. The development and realization of the control system are first described and then assessed in the wind tunnel. The objective of the research was to control the supersonic flow using the minimum amount of energy. The array of electrodes was located at the base of a ramp, where a low momentum flow develops. The electrical discharge was generated by a custom designed electronic facility based on high-voltage ignition coils. The slanted tungsten electrodes were insulated by mounting them in a ceramic support. The discharge evolution was studied through high-speed flow visualizations, while electrical measurements at the high-voltage section of the circuitry allowed to estimate the energy release. The development of a high-speed short exposure Schlieren imaging technique, based on a very short duration laser pulse illumination and a double shot CCD camera, allowed to observe the macroscopic effects associated with the arc establishment between the electrodes (glow, sound wave and heat release). Due to the long residence time, the thermal perturbation spread along the streamwise direction. Cross correlation of Schlieren images with short time separation revealed that in supersonic conditions, the discharges led to an overall acceleration of the flow field underneath the oblique shock wave.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Holotomography Phase-Retrieval

Holotomography is a non-destructive x-ray imaging technique which allows to visualize the interior morphology of object without damaging them. It is similar to x-ray computed tomography (CT), but unlike conventional CT, which is based on the attenuation of x-rays passing through the object, holotomography exploits the phase shift caused by the sample. This phase-contrast imaging allows to increase image contrast by recovering refractive index of materials and is proven to be more sensitive to density variations than conventional absorption-based X-ray imaging when applied to low-Z materials. In holotomography, the phase is retrieved by measuring the variations in intensity of the object at different sample to detector distances. Several algorithms exist to perform this task such as, contrast transfer function (CTF), transport of intensity equation (TIE), and a mixed approach which combine both TIE and CTF.

Forien, Jean-Baptiste↗

Bio-Medical and Plant Biology Imaging Tools Derived from Nuclear Physics Detector Development

Basic nuclear physics research requires continuing advances in detector technology. Often, new detection technology can have applications outside basic nuclear physics research. For over 80 years various sciences have been using radioactive isotopes as tracers for increasing our understanding of biological processes in living systems. New nuclear physics detection technologies using scintillators and photo multipliers have been used to develop imaging tools for radioisotope detection and imaging in bio-medical and plant biology applications. Nuclear imaging techniques such as positron emission tomography (PET) and single photon emission computed tomography (SPECT) benefit greatly from advances in nuclear physics detector technology. Bio-medical research utilizing animals as in pre-clinical research and in clinical applications such as cancer detection and treatment have benefited much from nuclear physics detector advances. New imaging tools are being developed for plant biology research to enhance our understanding of metabolic processes necessary for efficient biofuel production in a changing environment and of best bioassays for environmental remediation. The Radiation Detector and Imaging Group at Thomas Jefferson National Accelerator Facility has been applying detector technology to these applications. The examples of detector systems for medical and plant biology applications as well as scientific motivations driving use of radioisotope tracers in these applications will be presented.

Weisenberger, Andrew↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

In-Situ Spatial Mapping of Hydrogen in Yttrium Hydrides at LANSCE

This report summarizes the neutron imaging techniques and experimental activities performed at the Los Alamos Neutron Science Center (LANSCE) with the main goal of measuring temperature driven hydrogen diffusion within bulk-yttrium hydride (YH x ) materials. The experimental results and technique developments reported herein support the US Department of Energy Office of Nuclear Energy’s (DOE-NE) Microreactor Program under Technology Maturation. In particular, the critical need to experimentally validate and verify hydrogen-diffusion models of metal hydrides used in hightemperature microreactor designs is addressed by means of high-spatial-resolution neutron imaging coupled with custom-built and application-specific furnaces. These capabilities were designed to apply large temperature gradients across centimeter-sized YH x pellets to simulate conditions faced in the microreactor environment. Neutron imaging, combined with in-situ sample heating, enables near real-time tracking of hydrogen diffusion in YH x on the sub-millimeter scale. In this report, an overview of neutron imaging methodology and technologies are given in the context of recent spatial measures of hydrogen concentrations in similar metals hydrides. Additionally, the commissioning and operation of a custom-built compact dual-zone furnace is given along with details on the first two in-situ heating measurements of YH x performed over the 2020 and 2021 LANSCE operation cycles. In parallel with in-situ heating measurements, neutron computed tomography scans were performed to visualize hydrogen aggregates in post-heated YH x samples. Analysis and results from these neutron imaging measurements are given along with outlooks and plans for improving future hydrogen diffusion measurements at LANSCE.

47 OTHER INSTRUMENTATION↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AXIOM: Advanced X-Ray Imaging of the Magnetosphere

Planetary plasma and magnetic field environments can be studied in two complementary ways by in situ measurements, or by remote sensing. While the former provide precise information about plasma behaviour, instabilities and dynamics on local scales, the latter offers the global view necessary to understand the overall interaction of the magnetospheric plasma with the solar wind. Some parts of the Earth's magnetosphere have been remotely sensed, but the majority remains unexplored by this type of measurements. Here we propose a novel and more elegant approach employing remote X-ray imaging techniques, which are now possible thanks to the relatively recent discovery of solar wind charge exchange X-ray emissions in the vicinity of the Earth's magnetosphere. In this article we describe how an appropriately designed and located X-ray telescope, supported by simultaneous in situ measurements of the solar wind, can be used to image the dayside magnetosphere, magnetosheath and bow shock, with a temporal and spatial resolution sufficient to address several key outstanding questions concerning how the solar wind interacts with the Earth's magnetosphere on a global level. Global images of the dayside magnetospheric boundaries require vantage points well outside the magnetosphere. Our studies have led us to propose AXIOM: Advanced X-ray Imaging Of the Magnetosphere, a concept mission using a Vega launcher with a LISA Pathfinder-type Propulsion Module to place the spacecraft in a Lissajous orbit around the Earth Moon L1 point. The model payload consists of an X-ray Wide Field Imager, capable of both imaging and spectroscopy, and an in situ plasma and magnetic field measurement package. This package comprises a Proton-Alpha Sensor, designed to measure the bulk properties of the solar wind, an Ion Composition Analyser, to characterize the minor ion populations in the solar wind that cause charge exchange emission, and a Magnetometer, designed to measure the strength and direction of the solar wind magnetic field. We also show simulations that demonstrate how the proposed X-ray telescope design is capable of imaging the predicted emission from the dayside magnetosphere with the sensitivity and cadence required to achieve the science goals of the mission.

Branduardi-Raymont, G.↗

AXIOM: Advanced X-ray Imaging of the Magnetosphere

Planetary plasma and magnetic field environments can be studied in two complementary ways - by in situ measurements, or by remote sensing. While the former provide precise information about plasma behaviour, instabilities and dynamics on local scales, the latter offers the global view necessary to understand the overall interaction of the magnetospheric plasma with the solar wind. Some parts of the Earth's magnetosphere have been remotely sensed, but the majority remains unexplored by this type of measurements. Here we propose a novel and more elegant approach employing remote X-ray imaging techniques. which are now possible thanks to the relatively recent discovery of solar wind charge exchange X-ray emissions in the vicinity of the Earth's magnetosphere. In this article we describe how an appropriately designed and located. X-ray telescope, supported by simultaneous in situ measurements of the solar wind, can be used to image the dayside magnetosphere, magnetosheath and bow shock. with a temporal and spatial resolution sufficient to address several key outstanding questions concerning how the solar wind interacts with the Earth's magnetosphere on a global level. Global images of the dayside magnetospheric boundaries require vantage points well outside the magnetosphere. Our studies have led us to propose 'AXIOM: Advanced X-ray Imaging Of the Magnetosphere', a concept mission using a Vega launcher with a LISA Pathfinder-type Propulsion Module to place the spacecraft in a Lissajous orbit around the Earth - Moon Ll point. The model payload consists of an X-ray Wide Field Imager, capable of both imaging and spectroscopy, and an in situ plasma and magnetic field measurement package. This package comprises a Proton-Alpha Sensor, designed to measure the bulk properties of the solar wind, an Ion Composition Analyser, to characterize the minor ion populations in the solar wind that cause charge exchange emission, and a Magnetometer, designed to measure the strength and direction of the solar wind magnetic field. We also show simulations that demonstrate how the proposed X-ray telescope design is capable of imaging the predicted emission from the dayside magnetosphere with the sensitivity and cadence required to achieve the science goals of the mission.

Branduardi-Raymont, G.↗

Optical contrast analysis of α -RuCl 3 nanoflakes on oxidized silicon wafers

α-RuCl 3 , a narrow-band Mott insulator with a large work function, offers intriguing potential as a quantum material or as a charge acceptor for electrical contacts in van der Waals devices. In this work, we perform a systematic study of the optical reflection contrast of α-RuCl 3 nanoflakes on oxidized silicon wafers and estimate the accuracy of this imaging technique to assess the crystal thickness. Via spectroscopic micro-ellipsometry measurements, we characterize the wavelength-dependent complex refractive index of α-RuCl 3 nanoflakes of varying thickness in the visible and near-infrared. Building on these results, we simulate the optical contrast of α-RuCl 3 nanoflakes with thicknesses below 100 nm on SiO 2 /Si substrates under different illumination conditions. We compare the simulated optical contrast with experimental values extracted from optical microscopy images and obtain good agreement. Finally, we show that optical contrast imaging allows us to retrieve the thickness of the RuCl 3 nanoflakes exfoliated on an oxidized silicon substrate with a mean deviation of –0.2 nm for thicknesses below 100 nm with a standard deviation of only 1 nm. Our results demonstrate that optical contrast can be used as a non-invasive, fast, and reliable technique to estimate the α-RuCl 3 thickness.

2D materials↗

Single-particle scattering spectroscopy: fundamentals and applications

Metallic nanoparticles supporting a localized surface plasmon resonance have emerged as promising platforms for nanoscopic labels, sensors, and (photo-) catalysts. To use nanoparticles in these capacities, and to gain mechanistic insight into the reactivity of inherently heterogeneous nanoparticles, single-particle characterization approaches are needed. Single-particle scattering spectroscopy has become an important, highly sensitive tool for localizing single plasmonic nanoparticles and studying their optical properties, local environment, and reactivity. In this review, we discuss approaches taken for collecting the scattered light from single particles, their advantages and disadvantages, and present some recent applications. We introduce techniques for the excitation and detection of single-particle scattering such as high-angle dark-field excitation, total internal reflection dark-field excitation, scanning near-field microscopy, and interferometric scattering. We also describe methods to achieve polarization-resolved excitation and detection. We then discuss different approaches for scanning, ratiometric, snapshot, and interferometric hyperspectral imaging techniques used to extract spectral information. Finally, we provide a brief overview of specialized setups for in situ measurements of nanoparticles in liquid systems and setups coupled to scanning tip microscopes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗