Search NASA⌕ Search

SEARCH · Search NASA

Results for “Implementation Plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

SU-G-JeP2-08: Image-Guided Radiation Therapy Using Synthetic CTs in Brain Cancer

Purpose: Synthetic-CTs(synCTs) are essential for MR-only treatment planning. However, the performance of synCT for IGRT must be carefully assessed. This work evaluated the accuracy of synCT and synCT-generated DRRs and determined their performance for IGRT in brain cancer radiation therapy. Methods: MR-SIM and CT-SIM images were acquired of a novel anthropomorphic phantom and a cohort of 12 patients. SynCTs were generated by combining an ultra-short echo time (UTE) sequence with other MRI datasets using voxel-based weighted summation. For the phantom, DRRs from synCT and CT were compared via bounding box and landmark analysis. Planar (MV/KV) and volumetric (CBCT) IGRT performance were evaluated across several platforms. In patients, retrospective analysis was conducted to register CBCTs (n=34) to synCTs and CTs using automated rigid registration in the treatment planning system using whole brain and local registration techniques. A semi-automatic registration program was developed and validated to rigidly register planar MV/KV images (n=37) to synCT and CT DRRs. Registration reproducibility was assessed and margin differences were characterized using the van Herk formalism. Results: Bounding box and landmark analysis of phantom synCT DRRs were within 1mm of CT DRRs. Absolute 2D/2D registration shift differences ranged from 0.0–0.7mm for phantom DRRs on all treatment platforms and 0.0–0.4mm for volumetric registrations. For patient planar registrations, mean shift differences were 0.4±0.5mm (range: −0.6–1.6mm), 0.0±0.5mm, (range: −0.9–1.2mm), and 0.1±0.3mm (range: −0.7–0.6mm) for the superior-inferior(S-I), left-right(L–R), and anterior-posterior(A-P) axes, respectively. Mean shift differences in volumetric registrations were 0.6±0.4mm (range: −0.2–1.6mm), 0.2±0.4mm (range: −0.3–1.2mm), and 0.2±0.3mm (range: −0.2–1.2mm) for S-I, L–R, and A–P axes, respectively. CT-SIM and synCT derived margins were within 0.3mm. Conclusion: DRRs generated via synCT agreed well with CT-SIM. Planar and volumetric registrations to synCT-derived targets were comparable to CT. This validation is the next step toward clinical implementation of MR-only planning for the brain. The submitting institution has research agreements with Philips Healthcare. Research sponsored by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

WE-A-16A-01: International Medical Physics Symposium: Increasing Access to Medical Physics Education/Training and Research Excellence

In response to a world in which cancer is a growing global health challenge, there is now a greater need for US Medical Physicists and other Radiation Oncology professionals across institutions to work together and be more globally engaged in the fight against cancer. There are currently many opportunities for Medical Physicists to contribute to alleviating this pressing need, especially in helping enhance access to Medical Physics Education/training and Research Excellence across international boundaries, particularly for low and middle-income countries (LMIC), which suffer from a drastic shortage of accessible knowledge and quality training programs in radiotherapy. Many Medical Physicists are not aware of the range of opportunities that even with small effort could have a high impact. Faculty at the two CAMPEP-accredited Medical Physics Programs in New England: the University of Massachusetts Lowell and Harvard Medical School have developed a growing alliance to increase Access to Medical Physics Education/training and Research Excellence (AMPERE), and facilitate greater active involvement of U.S. Medical Physicists in helping the global fight against cancer and cancer disparities. In this symposium, AMPERE Alliance members and partners from Europe and Africa will present and discuss the growing global cancer challenge, the dearth of knowledge, research, and other barriers to providing life-saving radiotherapy in LMIC, mechanisms for meeting these challenges, the different opportunities for participation by Medical Physicists, including students and residents, and how participation can be facilitated to increase AMPERE for global health. Learning Objectives: To learn about the growing global cancer challenge, areas of greatest need and limitations to accessing knowledge and quality radiotherapy training programs, especially in LMIC; To learn about the range of opportunities for Medical Physicists, including students and residents, to work together in global health to help increase AMPERE and alleviate the growing global burden of cancer; To present and discuss a new model for harmonizing Medical Physics Training across countries and how this model (UMass and Heidelberg) could be extended to LMIC in collaboration with the IAEA; To highlight a new platform and program for facilitating contributions by Medical Physicists to increase AMPERE towards the elimination of global cancer disparities. Challenges in Cancer Control in Africa Twalib A. Ngoma, MD, Professor, Executive Director, Ocean Road Cancer Institute, Dar Es Salaam, Tanzania Cancer care in Africa is beset by lack of attention, political will, cancer registries, cancer plans, human resources, financial resources and treatment facilities.. As a result of this, cancer patients in Africa are far more likely to die of their disease than those in developed countries. According to data from the WHO 750,000 new cancer cases occur in Africa every year and this number is predicted to rise by 70% by 2020. To make matters worse, an estimated 75% of cancer patients in Africa have advanced or incurable cancers at diagnosis making palliative care the most realistic approach to their management. Furthermore, Cancer prevention is nearly nonexistent, cancer detection is rare and treatment usually comes too late and is inefficient. The overall mortality-to-incidence ratio for men with cancer in the Africa is 0.75 compared with 0.54 in the developed world while the ratios for women in Africa, is 0.65 compared with 0.45 for women in the developed world. There is also limited access to radiotherapy. According to the International Atomic Energy Agency (IAEA), whilst developed countries usually have one radiotherapy machine per 250,000 people, most African nations have only one machine per ten million people. The above numbers are alarming and speak for themselves. The only solution to improve this alarming situation is to address the major challenges which African countries face in provision of cancer services which include but not limited to lack of cancer registries, lack of funding, lack of human resources, lack of radiotherapy machines, lack of cancer drugs and lack of accessible and affordable cancer screening, early diagnosis, treatment or palliative care services. Since there are considerable differences among African countries, in my presentation I will share with the audience how we address cancer control challenges in Tanzania in general and specifically in radiation oncology. The African continent cancer plan 2013 2017 Folakemi Odedina, PhD, Professor and Director of Health Disparities, UF Health Cancer Center, University of Florida The burden of cancer is rising in Africa, in addition to current heavy burden of communicable, and other non-cancer related non—communicable diseases. Conquering cancer in Africa will require a comprehensive collaborative approach with cancer clinicians, scientists, patients, advocates, policy makers and community leaders working hand-in-hand at the local, state, national, and continent levels with the primary mission: To reduce the number of deaths from cancer and improve the quality of life of cancer patients, survivors and caregivers. Unfortunately, less than 40% of African countries have a credible cancer control policy and program. The African Organization for Research and Training in Cancer (AORTIC) decided to create an African Cancer Plan to provide cost-effective strategies that can be employed throughout the continent to fight cancer. Based on the African proverb that “It takes a village to raise a child”, the Cancer Plan provides specific strategies that can be used by individuals, employers, organizations and policy-makers to fight cancer. In addition, we have provided overarching strategies to address cancer in Africa and targeted 5-year plan for prostate, breast, cervix, lung and liver cancers. In developing this Cancer Plan, our primary goal is to decrease cancer incidence and mortality in Africa. This goal can only be achieved by stakeholders and dedicated individuals to lead and implement the strategies outlined in this plan. If you are interested in partnering with AORTIC to reduce the burden of cancer in Africa, please send an email to info@aortic-africa.org. Synergies in research and clinical care through international collaboration Thomas Bortfeld and David Gierga, Massachusetts General Hospital, Harvard Medical School, MA Medical Physics relies on high technology that is not distributed equally. The whole spectrum of Medical Physics technologies is not available at every hospital or research institute, and not even in every high income country. One example is heavy ion therapy equipment which is currently only available in Japan, Germany and Italy. There is also a large global variation in terms of research infrastructure and focus. A student of Medical physics cannot gain broad experience, certainly not hands-on experience, by staying at one place only. While it is debatable what a good trade-off between breadth and depth in Medical Physics education is, it is generally agreed upon that some breadth is necessary. Researchers in Medical Physics have to cross borders if they need specific technologies for their projects. Therefore it is self-evident that international programs in Medical Physics education and research make sense. Yet, very few programs of this type exist. In this presentation we will report on our own experience of pursuing an international career in Medical Physics, with international student programs, and with the international exchange of researchers. We will present new or planned opportunities such as the medical beamline at CERN in Geneva. We will also report on the synergies in clinical care through international collaborations between partners in high and low income countries. One example is the partnership of the MGH/Harvard Medical School community with the oncology community and government of Botswana to form the BOTSOGO (BOTSwana Oncology Global Outreach) initiative. This collaborative effort in oncology care was spurred by existing relationships in HIV/AIDS research and care delivery developed within the Botswana-Harvard AIDS Institute Partnership (BHP). The initial efforts of the BOTSOGO initiative have been organized as follows: 1) on-site visits to share expertise in clinical cancer care for capacity building purposes (e.g. cervical brachytherapy), 2) developing a forum for multi-disciplinary case discussions and education and 3) relationship building with local stakeholders for long-term sustainability and growth. An international system for the certification of medical physicists Raymond K. Wu, Chairman, IOMP Professional Relations Committee; Chairman, AAPM Exchange Scientist Program Subcommittee An international system for the certification of medical physicists is an important issue. The International Organization for Medical Physicists (IOMP) has in collaboration with a number of member countries established the International Medical Physics Certification Board (IMPCB) to address this issue, and to provide a mechanism to mark the milestone for the professional development of clinical medical physicists. Raymond Wu, PhD, is the CEO of IMPCB and the Chairman of the IOMP Professional Relations Committee. He is the invited speaker recommended by IOMP to give a talk on this important subject. He will give the latest update of the work of IMPCB, its near term goals, and pathways to the goals. He will also discuss the importance of such an International System of certification in the training/education of next generation Medical Physicists, including those in low and middle income countries (LMIC) where such training is crucial in the fight against cancer. Learning Objectives: Understand the certification program as described in the IOMP Policy Statements. Understand the plan of the IMPCB to establish the accreditation process of national certification programs. Understand the goals of this international collaborative effort and the potential impacts to the quality of clinical medical physics practice. Medical Physics Education Across Continents: The UMass Lowell and Heidelberg University Joint Coordination Effort Erno Sajo, Director of Medical Physics, University of Massachusetts at Lowell Medical Physics education has unique flavors across institutions within the US and shows significant differences across continents. In the latter, even the definition of Medical Physics may differ. Not only is there a difference in topical coverage, but often what is considered a cohesive topic in one institution, and taught as a single course, is fragmented among several other courses in the other institution due to a different philosophy. Because of the regulatory and certification requirements, these differences impact the mobility of medical physicists across continents. As a result, physicists who wish to practice in the US or Canada but have completed their education elsewhere often find that they have to take remedial courses or even obtain a new degree in Medical Physics despite the fact that they already have one. Outreach to developing countries, therefore, is even more difficult. The University of Massachusetts Lowell and Heidelberg University recently completed a joint coordination effort, in which they identified topics that are common versus complementary in their medical physics curricula. A student exchange program was developed that permits students to take any of the common topics at the other institution while taking complementary courses as electives, which count towards their degree requirements at their home institution. Thesis research is also mutually accepted. When properly documented, in this way CAMPEP recommendations can be met across the institutions. Therefore, students participating in this program satisfy both the American Board of Radiology (ABR) requirements and the European regulatory requirements. The framework on which this collaboration rests and the cross-comparison methods developed therein may be implemented in other exchange programs and thus a similar approach can be adopted in outreach programs with developing countries. IAEA PACT Program and opportunities for support and collaboration Susan Morgan, Program Coordinator, International Atomic Energy Agency, Vienna, Austria In response to the developing world's cancer crisis, the International Atomic Energy Agency (IAEA) established the Program of Action for Cancer Therapy (PACT) in 2004 to fully realize the public health impact obtained through global partnerships in cancer control and technology transfer in radiation medicine. PACT's vision strives for global partnerships to confront the cancer crisis in developing countries, notably with our sister United Nations agency, the World Health Organization (WHO), and our Joint Programme on Cancer Control established in 2009. The IAEA, through PACT, the WHO, the International Agency for Research on Cancer (IARC) and other cancer-related organizations work together to make a coordinated global response in supporting low and middle income (LMI) IAEA Member States in the implementation of comprehensive national cancer control programmes. PACT's goals are: To build global partnerships of cancer-related organizations committed to addressing the challenge of cancer in LMI Member States in all its aspects; To mobilize resources from charitable trusts, foundations, and others in public and private sectors sources to assist LMI Member States to develop and implement their radiation medicine capacities within a national cancer control programme (NCCP); and, To ensure the effective and sustainable transfer of radiation medicine technologies or knowledge to all LMI Member States where unmet needs exist. PACT work focuses on: imPACT: Assessing Cancer Burden PMDS: Developing Global Partnerships VUCCnet: Promoting Cancer Control Training AGaRT: Making Radiotherapy Accessible Facilitating increased participation and professional development of Medical Physicists and other Radiation Oncology professionals in global health Wilfred Ngwa, Harvard Medical School, University of Massachusetts Lowell, MA The 2014 World Health Organization (WHO) Cancer report highlights an alarming increase in the global burden of cancer. It also highlights what it terms “the cancer divide”, or disparities, evinced by a substantially higher cancer burden in low and middle income countries (LMIC) in Asia, Central/South America and Africa. The WHO even predicts a potential African cancer epidemic by 2020 if significant progress is not made in global cancer control efforts. Evidence that collaborative global health approaches have led to major progress in controlling infectious diseases including in LMIC suggests that similar approaches will be useful for non-communicable diseases like cancer. In consonance with this, leaders in cancer policy from the USA and 14 economically diverse countries recently concluded that successful campaigns to control cancers with existing methods and to improve current strategies will increasingly depend onconcerted multinational collaborations (Sci Transl Med 5, p. 175, 2013). Hence there is growing urgency for increasing collaborative global cancer Care Research and Education (CaRE), as well as support for greater effectiveness of already existing initiatives involving partners from different nations, diverse economic and cultural backgrounds. The good news is that there is a growing awareness of the importance of global health and growing interest including amongst Medical Physicists and other Radiation oncology (RadOnc) professionals to participate in global health. However, many are unaware of currently existing opportunities for participation that even with small effort could have a high impact. Over 50% of cancer patients in the developed world depend on RadOnc professionals for their treatment, and hence participation of RadOnc professionals in global health efforts in the global fight against cancer is crucial. It is also important that the next generation of RadOnc professionals (students, and residents) be trained with a global perspective, to be global health leaders in cancer CaRE. This presentation will highlight a novel platform for enhancing participation and professional development of Medical Physicists and other RadOnc professionals in global health. Ways in which this platform can facilitate contributions by Medical Physicists and other RadOnc Professionals, students and residents in global health towards the elimination of global cancer disparities will be discussed. This will be followed by a panel discussion by some of the pioneers/leaders in collaborative global cancer CaRE on the growing cancer burden, challenges and opportunities for greater active involvement and professional development.

60 APPLIED LIFE SCIENCES↗

SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits.

60 APPLIED LIFE SCIENCES↗

Capacity building in rural Guatemala by implementing a solid waste management program

The development and implementation of a solid waste management program served to build local capacity in San Mateo Ixtatan between 2002 and 2003 as part of a public health action plan. The program was developed and implemented in two phases: (1) the identification and education of a working team from the community; and (2) the completion of a solid waste classification and quantification study. Social capital and the water cycle were two public health approaches utilized to build a sustainable program. The activities accomplished gained support from the community and municipal authorities. A description of the tasks completed and findings of the solid waste classification and quantification performed by a local working group are presented in this paper.

54 ENVIRONMENTAL SCIENCES↗

Monitoring Avian Productivity and Survivorship at the Sandia Wetlands at Los Alamos National Laboratory (2014-2019)

Biologists at Los Alamos National Laboratory completed six years (2014–2019) of demographic monitoring of passerines (songbirds) during the breeding season in Los Alamos, New Mexico. We captured songbirds at a mist netting station located in the Sandia Wetlands in Sandia Canyon (Technical Areas 60 and 61). We identified, measured, and then banded captured birds with federal migratory bird bands. Banding operations took place between May and August of each year, with 10 mist netting sessions annually. We conducted this project as part of the implementation of the Biological Resources Management Plan. The project complies with the 2013 Memorandum of Understanding between the United States Fish and Wildlife Service (USFWS) and the United States Department of Energy regarding the implementation of Executive Order 13186. The overall number of birds and species captured was variable, and we saw no decreases over the course of six years in bird species diversity, abundance, or the percentage of breeding birds. Our results indicate that the Sandia Wetlands support numerous species of breeding birds, including species of conservation concern. We did not see a declining trend for the top 10 most-captured species or for any of the species of conservation concern over time; however, we need more years of data to make robust conclusions about population trends through time. Our results indicated that adult recapture rates at the Sandia Wetlands are at least twice as low when compared with estimated adult survival in migratory passerines from peer-reviewed literature. We also did not recapture any birds that were banded as juveniles in subsequent years throughout the entire six-year period. Low recapture rates for adults and the non-existent recapture rates for juveniles should be explored further. To accurately assess individual species survival rates for adults and juveniles using mark-recapture models, we need a longer dataset, which would allow for a more robust analysis.

59 BASIC BIOLOGICAL SCIENCES↗

National Smart Manufacturing Strategic Plan: To Facilitate More Rapid Development, Deployment and Adoption of Smart Manufacturing Technologies

Smart manufacturing technologies provide real-time data and insight to improve the productivity, efficiency, and competitiveness of U.S. manufacturing, creating the potential for new jobs in the manufacturing sector. These technologies can support U.S. manufacturers’ ability to increase throughput and energy efficiency, and decrease waste, defects, and costs. A wide range of manufacturing and industrial subsectors, particularly energy-intensive and energy-dependent industries, have the potential to benefit from smart manufacturing technologies. There are technical improvements still needed to reduce the costs and barriers (trained workforce and upskilling, software-hardware integration, cost, and technical barriers to deployment of advanced sensors, computing, and communication technologies for existing manufacturing assets) to the adoption of smart manufacturing technologies, especially to small and medium-sized manufacturers, and subsequently, increase the overall adoption rate of smart manufacturing technologies. This report outlines the Department of Energy’s (DOE) strategic plan to accelerate the development and implementation of smart manufacturing technologies in the United States and the actions DOE has taken to use these technologies in smart manufacturing for the United States. DOE’s plan to facilitate more rapid development, deployment and widespread adoption of smart manufacturing technologies derive from the 2018 Strategy for American Leadership in Advanced Manufacturing. The strategy outlines a vision for America’s leadership in advanced manufacturing including the development of intelligent manufacturing systems to optimize manufacturing facilities and support the manufacturing of transformative materials. DOE’s Clean Energy Smart Manufacturing Innovation Institute (CESMII), a Manufacturing USA Institute, focuses on accelerating the development and adoption of advanced sensors, controls, platforms, and models needed for smart manufacturing. The objective is to enhance U.S. manufacturing productivity and global competitiveness through the research and development of these technologies. Smart manufacturing has the potential to improve the overall performance, energy productivity, and efficiency of manufacturing, fostering the economic competitiveness of the manufacturing sector.

99 GENERAL AND MISCELLANEOUS↗

Distribution System Plan Template and Guide for Electric Utilities for Adaptation by States and Utilities [Slides]

LBNL researchers developed a template and companion guide for structuring distribution system plans. The template covers 10 key sections in utility distribution system plans and underlying topics: -Executive Summary -Planning Objectives -Current Distribution System -Planning Approach -Asst Management, Reliability and Resilience -O&M Expenses -Capacity Expansion Planning -Solution Identification -Cost-effectiveness -Implementation For each section in the template, the companion guide provides: a description of the topics covered and their importance; the type of content to include in the plan; an example utility approach; and references to other utility plans that serve as models for the topic.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-F-T-241: Reduction in Planning Errors Via a Process Control Developed Using the Eclipse Scripting API

Purpose: Errors found during initial physics plan checks frequently require replanning and reprinting, resulting decreased departmental efficiency. Additionally, errors may be missed during physics checks, resulting in potential treatment errors or interruption. This work presents a process control created using the Eclipse Scripting API (ESAPI) enabling dosimetrists and physicists to detect potential errors in the Eclipse treatment planning system prior to performing any plan approvals or printing. Methods: Potential failure modes for five categories were generated based on available ESAPI (v11) patient object properties: Images, Contours, Plans, Beams, and Dose. An Eclipse script plugin (PlanCheck) was written in C# to check errors most frequently observed clinically in each of the categories. The PlanCheck algorithms were devised to check technical aspects of plans, such as deliverability (e.g. minimum EDW MUs), in addition to ensuring that policy and procedures relating to planning were being followed. The effect on clinical workflow efficiency was measured by tracking the plan document error rate and plan revision/retirement rates in the Aria database over monthly intervals. Results: The number of potential failure modes the PlanCheck script is currently capable of checking for in the following categories: Images (6), Contours (7), Plans (8), Beams (17), and Dose (4). Prior to implementation of the PlanCheck plugin, the observed error rates in errored plan documents and revised/retired plans in the Aria database was 20% and 22%, respectively. Error rates were seen to decrease gradually over time as adoption of the script improved. Conclusion: A process control created using the Eclipse scripting API enabled plan checks to occur within the planning system, resulting in reduction in error rates and improved efficiency. Future work includes: initiating full FMEA for planning workflow, extending categories to include additional checks outside of ESAPI via Aria database queries, and eventual automated plan checks.

60 APPLIED LIFE SCIENCES↗

LANL Water Protection Status Report - FY12 3rd Qtr. (Apr thru Jun 2012)

Continued monitoring of the Buckman Direct Diversion and Los Alamos County Water Supply Wells; Groundwater Protection - Continued implementation of the Interim Facility-Wide Groundwater Monitoring Plan (IFGMP); Surface Water Protection - Continued protection of surface water through implementation of the Individual Stormwater Permit (IP); Buckman Early Notification System operability at 100% per MOU Requirements.

Environmental Protection↗

IDAES GTEP 0.1 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Generation and Transmission Expansion Planning (GTEP) package provides a Pyomo-based implementation of a modular, flexible, Generalized Disjunctive Programming (GDP) formulation for power infrastructure planning problems. This package is designed with the following goals in mind: - Abstract GTEP modeling away from any particular case study or fixed modeling assumptions (e.g., technologies, temporal resolution, spatial resolution, policy implications, etc.) - Admit flexible decision sets and heterogeneous parameterization - Allow high-level modeling options to be understood easily, chosen modularly, and changed rapidly

AS↗

Seventh Oregon Climate Assessment

Consistent with its charge under Oregon House Bill 3543, the Oregon Climate Change Research Institute (OCCRI) conducts a biennial assessment of the state of climate change science, including biological, physical, and social science, as it relates to Oregon and the likely effects of climate change on Oregon. This seventh Oregon Climate Assessment, which builds on the previous assessments, is structured with the goal of supporting the state's mitigation planning for natural hazards and implementation of the Oregon Climate Change Adaptation Framework.

17 WIND ENERGY↗

Fully Automated Simultaneous Integrated Boosted-Intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical Study

Purpose: To prospectively determine whether overlap volume histogram (OVH)-driven, automated simultaneous integrated boosted (SIB)-intensity-modulated radiation therapy (IMRT) treatment planning for head-and-neck cancer can be implemented in clinics. Methods and Materials: A prospective study was designed to compare fully automated plans (APs) created by an OVH-driven, automated planning application with clinical plans (CPs) created by dosimetrists in a 3-dose-level (70 Gy, 63 Gy, and 58.1 Gy), head-and-neck SIB-IMRT planning. Because primary organ sparing (cord, brain, brainstem, mandible, and optic nerve/chiasm) always received the highest priority in clinical planning, the study aimed to show the noninferiority of APs with respect to PTV coverage and secondary organ sparing (parotid, brachial plexus, esophagus, larynx, inner ear, and oral mucosa). The sample size was determined a priori by a superiority hypothesis test that had 85% power to detect a 4% dose decrease in secondary organ sparing with a 2-sided alpha level of 0.05. A generalized estimating equation (GEE) regression model was used for statistical comparison. Results: Forty consecutive patients were accrued from July to December 2010. GEE analysis indicated that in APs, overall average dose to the secondary organs was reduced by 1.16 (95% CI = 0.09-2.33) with P=.04, overall average PTV coverage was increased by 0.26% (95% CI = 0.06-0.47) with P=.02 and overall average dose to the primary organs was reduced by 1.14 Gy (95% CI = 0.45-1.8) with P=.004. A physician determined that all APs could be delivered to patients, and APs were clinically superior in 27 of 40 cases. Conclusions: The application can be implemented in clinics as a fast, reliable, and consistent way of generating plans that need only minor adjustments to meet specific clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Evaluation and Preparation in Vascular and Interventional Radiology: What Every Interventional Radiologist Should Know (Part 1: Patient Assessment and Laboratory Tests)

Performing an interventional procedure imposes a commitment on interventional radiologists to conduct the initial patient assessment, determine the best course of therapy, and provide long-term care after the procedure is completed. After patient referral, contact with the referring physician and multidisciplinary team approach is vital. In addition, clinical history, physical examination, as well as full understanding of the pre-procedural laboratory results and imaging findings can guide the interventional radiologist to implement the most appropriate management plan, avoid unnecessary procedures, and prevent complications to achieve a successful outcome. We provide a comprehensive, methodical review of pre-procedural care and management in patients undergoing vascular and interventional radiology procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radioxenon detector calibration spike production and delivery systems

Abstract Beta-Gamma coincidence radioxenon detectors must be calibrated for each of the four-radioxenon isotopes (135Xe, 133Xe, 133mXe, and 131mXe). Without a proper calibration, there is potential for the misidentification of the amount of each isotope detected. It is important to accurately determine the amount of each radioxenon isotope, as the ratios can be used to distinguish between an anthropogenic source and a nuclear explosion. We have developed a xenon calibration system (XeCalS) that produces calibration spikes of known activity and pressure for field calibration of detectors. The activity concentrations of these calibration spikes are measured using a beta-gamma coincidence detector and a high purity germanium (HPGe) detector. We will present the results from the development and commissioning of XeCalS, along with the future plans for a portable spike implementation system.

beta-gamma coincidence detector↗

Adaptation of EVIAVE methodology for monitoring and follow-up when evaluating the environmental impact of landfills

Treatment and final disposal of Municipal Solid Waste can have a significant role in the generation of negative environmental impacts. As a prevention strategy, such activities are subjected to the process of Environmental Impact Assessment (EIA). Still, the follow-up of Environmental Management Plans or mitigation measures is limited, for one due to a lack of methodological approaches. In searching for possibilities, the University of Granada (Spain) developed a diagnostic methodology named EVIAVE, which allows one to quantify, by means of indexes, the environmental impact of landfills in view of their location and the conditions of exploitation. EVIAVE is applicable within the legal framework of the European Union and can be adapted to the environmental and legal conditions of other countries. This study entails its adaptation in Colombia, for the follow-up and control of the EIA process for landfills. Modifications involved inclusion of the environmental elements flora and fauna, and the evaluation of the environmental descriptors in agreement with the concept of vulnerability. The application of the modified EVIAVE in Colombian landfills allowed us to identify the elements affected by the operating conditions and maintenance. It may be concluded that this methodology is viable and effective for the follow-up and environmental control of EIA processes for landfills, and to analyze the associated risks, as it takes into account related environmental threats and vulnerabilities. - Highlights: • A modified methodology is used to monitor and follow-up environmental impacts in landfills. • The improved methodology includes the Vulnerability of Flora and Fauna to evaluate environmental impact of landfills. • The methodology serves to identify and evaluate the sources of risk generated in the construction and siting of landfills. • Environmental vulnerability indicators improve effectiveness of the control and follow-up phases of landfill management. • The follow-up of environmental management plans may help diminish the implementation gap in Environmental Impact Assessment.

54 ENVIRONMENTAL SCIENCES↗

Enhancements to the New TREAT Automatic Reactor Control System (ARCS)

The Transient Reactor Test (TREAT) facility recently replaced the automatic reactor control system (ARCS). Here, this paper discusses some of the enhancements that were made during the ARCS replacement such as calculations to take into account the nonadiabatic effects and increasing the dynamic range for power and period indication. This paper also discusses upgrades that had been planned but were unable to implemented and potential upgrades for the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PROTOTYPING NON-EQUILIBRIUM VISCOUS-TIMESCALE ACCRETION THEORY USING LMC X-3

Explaining variability observed in the accretion flows of black hole X-ray binary systems remains challenging, especially concerning timescales less than, or comparable to, the viscous timescale but much larger than the inner orbital period despite decades of research identifying numerous relevant physical mechanisms. We take a simplified but broad approach to study several mechanisms likely relevant to patterns of variability observed in the persistently high-soft Roche-lobe overflow system LMC X-3. Based on simple estimates and upper bounds, we find that physics beyond varying disk/corona bifurcation at the disk edge, Compton-heated winds, modulation of total supply rate via irradiation of the companion, and the likely extent of the partial hydrogen ionization instability is needed to explain the degree, and especially the pattern, of variability in LMC X-3 largely due to viscous dampening. We then show how evaporation-condensation may resolve or compound the problem given the uncertainties associated with this complex mechanism and our current implementation. We briefly mention our plans to resolve the question, refine and extend our model, and alternatives we have not yet explored.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessing the Optimality of LinDist3Flow for Optimal Tap Selection of Step Voltage Regulators in Unbalanced Distribution Networks

The adoption of distributed energy resources such as photovoltaics (PVs) has increased dramatically during the previous decade. The increased penetration of PVs into distribution networks (DNs) can cause voltage fluctuations that have to be mitigated. One of the key utility assets employed to this end are step-voltage regulators (SVRs). It is desirable to include tap selection of SVRs in optimal power flow (OPF) routines, a task that turns out to be challenging because the resultant OPF problem is nonconvex with added complexities stemming from accurate SVR modeling. While several convex relaxations based on semi-definite programming (SDP) have been presented in the literature for optimal tap selection, SDP based schemes do not scale well and are challenging to implement in large-scale planning or operational frameworks. This paper deals with the optimal tap selection (OPTS) problem for wye-connected SVRs using linear approximations of power flow equations. Specifically, the LinDist3Flow model is adopted and the effective SVR ratio is assumed to be continuous- enabling the formulation of a problem called LinDist3Flow-OPTS, which amounts to a linear program. The scalability and optimality gap of LinDist3Flow-OPTS are evaluated with respect to existing SDP-based and nonlinear programming techniques for optimal tap selection in three standard feeders, namely, the IEEE 13-bus, 123-bus, and 8500-node DNs. For all DNs considered, LinDist3Flow-OPTS achieves an optimality gap of approximately 1% or less while significantly lowering the computational burden.

linear approximations↗