Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inverter Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

High-Efficiency High-Density Critical Mode Rectifier/Inverter for WBG-Device-Based On-Board Charger

We report a widebandgap-based bidirectional on-board charger (OBC) has been proposed with a variable dc-link voltage, which tracks the battery voltage fluctuation. Although this approach is deemed most efficient for the resonant dc/dc stage, it posts significant challenges for the rectifier/inverter stage, which operates in the critical mode to realize zero-voltage switching (ZVS), while subjecting to the large variations of input and output voltages. Design considerations of the ac/dc stage are presented in this paper, including: the evaluation of 1.2-kV SiC MOSFETs; the ZVS extension techniques to realize ZVS under all input/output variations; and a novel universal control strategy for both the rectifier mode and the inverter mode. A prototype is built which achieves 98.5% efficiency at a switching frequency higher than 300 kHz. Lastly, a 6.6-kW OBC system is demonstrated, using both SiC and GaN devices with 37-W/in 3 power density and above 96% efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Molecular solid-state inverter-converter system

A modular approach for aerospace electrical systems has been developed, using lightweight high efficiency pulse width modulation techniques. With the modular approach, a required system is obtained by paralleling modules. The modular system includes the inverters and converters, a paralleling system, and an automatic control and fault-sensing protection system with a visual annunciator. The output is 150 V dc, or a low distortion three phase sine wave at 120 V, 400 Hz. Input power is unregulated 56 V dc. Each module is rated 2.5 kW or 3.6 kVA at 0.7 power factor.

Birchenough, A. G.↗

Lunar PMAD technology assessment

This report documents an initial set of power conditioning models created to generate 'ballpark' power management and distribution (PMAD) component mass and size estimates. It contains converter, rectifier, inverter, transformer, remote bus isolator (RBI), and remote power controller (RPC) models. These models allow certain studies to be performed; however, additional models are required to assess a full range of PMAD alternatives. The intent is to eventually form a library of PMAD models that will allow system designers to evaluate various power system architectures and distribution techniques quickly and consistently. The models in this report are designed primarily for space exploration initiative (SEI) missions requiring continuous power and supporting manned operations. The mass estimates were developed by identifying the stages in a component and obtaining mass breakdowns for these stages from near term electronic hardware elements. Technology advances were then incorporated to generate hardware masses consistent with the 2000 to 2010 time period. The mass of a complete component is computed by algorithms that calculate the masses of the component stages, control and monitoring, enclosure, and thermal management subsystem.

Metcalf, Kenneth J.↗

Free-spinning-tunnel Tests of a 1/26th Scale Model of the Douglas XTB2D-1 Airplane

A spin-tunnel investigation of a 1/26 scale model of the Douglas XTB2D-1 airplane has been conducted in the Langley 20-foot free-spinning tunnel. The effects of control settings and movements upon the erect- and inverted-spin and recovery characteristics of the model were determined for various loading conditions. Tests were also performed to determine the effects of various tail modifications. The investigation included emergency spin-recovery parachute tests as well as crew-escape and rudder- and elevator-force tests. All tests were performed at an equivalent spin altitute of 20,000 feet. The recovery characteristics of the model in the original design were found to be unsatisfactory. Installation of a large ventral fin, installation of tip fins on the horizontal tail, or installation of a small ventral fin in combination with antispan fillets and a spanwise extension of the horizontal-tail surfaces satisfactorily improved the recovery characteristics of the model.

Stone, Ralph W↗

Shoot inversion-induced ethylene in Pharbitis nil induces the release of apical dominance by restricting shoot elongation

Shoot inversion induces outgrowth of the highest lateral bud (HLB) adjacent to the bend in the stem in Pharbitis nil. In order to determine whether or not ethylene produced by shoot inversion plays a direct role in promoting or inhibiting bud outgrowth, comparisons were made of endogenous levels of ethylene in the HLB and HLB node of plants with and without inverted shoots. That no changes were found suggests that the control of apical dominance does not involve the direction action of ethylene. This conclusion is further supported by evidence that the direct application of ethylene inhibitors or ethrel to inactive or induced lateral buds has no significant effect on bud outgrowth. The hypothesis that ethylene evolved during shoot inversion indirectly promotes the outgrowth of the highest lateral bud (HLB) in restricting terminal bud (TB) growth is found to be supported by the following observations: (1) the restriction of TB growth appears to occur before the beginning of HLB outgrowth; (2) the treatment of the inverted portion of the shoot with AgNO3, an inhibitor of ethylene action, dramatically eliminates both the restriction of TB growth and the promotion of HLB outgrowth which usually accompany shoot inversion; and (3) the treatment of the upper shoot of an upright plant with ethrel mimics shoot inversion by retarding upper shoot growth and inducing outgrowth of the lateral bud basipetal to the treated region.

NASA Discipline Plant Biology↗

Grid-Forming Frequency Shaping Control for Low-Inertia Power Systems

As power systems transit to a state of high renewable penetration, little or no presence of synchronous generators makes the prerequisite of well-regulated frequency for grid-following inverters unrealistic. As such, there is a trend to resort to grid-forming inverters which set frequency directly. We propose a novel grid-forming frequency shaping control that is able to shape the aggregate system frequency dynamics into a first-order one with the desired steady-state frequency deviation and Rate of Change of Frequency (RoCoF) after a sudden power imbalance. The no overshoot property resulting from the first-order dynamics allows the system frequency to monotonically move towards its new steady-state without experiencing frequency Nadir, which largely improves frequency security. We prove that our grid-forming frequency-shaping control renders the system internally stable under mild assumptions. The performance of the proposed control is verified via numerical simulations on a modified Icelandic Power Network test case.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Harmonic control using matrix converter of unbalanced input voltage supplied from solar power system

Most of the renewable energy sources are not distributed directly to consumer. It gone through several section to get optimum output voltage and current with the almost zero distortion. Direct Matrix converters are well known of its better power quality and low power distortion to the reactive loads. Conversely, multilevel H bridge inverters are broadly used to attain a sinusoidal output voltage in solar photovoltaic application. Reactive power is subject to high importance for the operation of alternating current (AC) power systems. Moreover there is always a challenge to obtain the balance current control from an unbalanced supply voltage with minimum harmonic distortion for reactive load application from solar power system. The main objective of the proposed system is to maximize the power usage by maintaining the current and power factor nearby unity. There are many different optimization techniques are used so far in matrix converter, a novel method of optimization BAT algorithm is proposed for the power quality to get the best result. This work mainly deals with the compensation of reactive power used in Solar Photovoltaic Power System. Bidirectional energy flow is possible with matrix converter for battery charging. Simulation results are presented to confirm the appropriate operation of the system under different of operating conditions. Also, in the proposed method the percentage of the higher order harmonics can reduced less than 9% of matrix converter for solar photovoltaic application.

14 SOLAR ENERGY↗

Inverted Region in Bimolecular Electron Transfer in Solution Enabled by Delocalization

Rate constants for bimolecular electron transfer (ET) increased with driving force, -ΔG°, reached a plateau, and then decreased in an inverted region. This rate data was described well by electron transfer theory subject to a diffusion-controlled limit. These were for ET from radical anions of polydecylthiophene (P3DT) to a series of acceptors in THF solution. When the donor was the smaller anion of quaterthiophene (T4 •- ) the inverted region was much less prominent, and still less so for when the donor was the anion of bithiophene (T2 •- ). Description of the data using ET theory identifies smaller electronic couplings for the highly-delocalized P3DT anions as enabling the inverted behavior: The presence of a Marcus inverted region is a consequence of delocalized electronic states. The results of this study further imply that electronic couplings smaller than usually found for molecules in contact could boost efficiency of energy storage by electron transfer, and identifies size-mismatch as an important concept in control of electronic couplings.

14 SOLAR ENERGY↗

A grid-connected photovoltaic power conversion system with single-phase multilevel inverter

This paper presents a grid-connected photovoltaic (PV) power conversion system based on a single-phase multilevel inverter. The proposed system fundamentally consists of PV arrays and a single-phase multilevel inverter structure. First, configuration and structural parts of the PV assisted inverter system are introduced in detail. To produce reference output voltage waves, a simple switching strategy based on calculating switching angles is improved. By calculated switching angles, the reference signal is produced as a multilevel shaped output voltage wave. The control algorithm and operational principles of the proposed system are explained. Operating PV arrays in the same load condition is a considerable point; therefore a simulation study is performed to arrange the PV arrays. After determining the number and connection types of the PV arrays, the system is configured through the arrangement of the PV arrays. The validity of the proposed system is verified through simulations and experimental study. The results demonstrate that the system can achieve lower total harmonic distortion (THD) on the output voltage and load current, and it is capable of operating synchronous and transferring power values having different characteristic to the grid. Hence, it is suitable to use the proposed configuration as a PV power conversion system in various applications. (author)

14 SOLAR ENERGY↗

Wind-powered asynchronous AC/DC/AC converter system

Two asynchronous ac/dc/ac systems are modelled that utilize wind power to drive a variable or constant hertz alternator. The first system employs a high power 60-hertz inverter tie to the large backup supply of the power company to either supplement them from wind energy, storage, or from a combination of both at a preset desired current; rectifier and inverter are identical and operate in either mode depending on the silicon control rectifier firing angle. The second system employs the same rectification but from a 60-hertz alternator arrangement; it provides mainly dc output, some sinusoidal 60-hertz from the wind bus and some high harmonic content 60-hertz from an 800-watt inverter.

Reitan, D. K.↗

Cascaded Quadruple Active Bridge Structures for Multilevel DC to Three-Phase AC Conversion

This paper introduces a multilevel architecture comprised of interconnected dc to three-phase ac converter units. To enable series connected operation, each converter unit contains a quadruple active bridge (QAB) converter that provides isolation between the dc side and each of the three ac sides. Since each converter unit transfers dc-side power as constant balanced three-phase power on the ac side, this implies instantaneous input-output power balance and allows elimination of bulk capacitive energy storage. In addition to minimizing required capacitance, the proposed approach simultaneously enables simplified dc-link controllers amenable to decentralized implementation, supports bidirectional power transfer, and exhibits a modular structure to enhance scalability. Isolation provided by the QAB allows a wide range of electrical configurations among multiple units in various dc-ac, ac-dc or ac-ac applications. In this paper, the focus is on series connections on the ac side to emphasize multilevel operation, and the approach is experimentally validated in a dc-ac system containing two cascaded converter units.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A link-segment model of upright human posture for analysis of head-trunk coordination

Sensory-motor control of upright human posture may be organized in a top-down fashion such that certain head-trunk coordination strategies are employed to optimize visual and/or vestibular sensory inputs. Previous quantitative models of the biomechanics of human posture control have examined the simple case of ankle sway strategy, in which an inverted pendulum model is used, and the somewhat more complicated case of hip sway strategy, in which multisegment, articulated models are used. While these models can be used to quantify the gross dynamics of posture control, they are not sufficiently detailed to analyze head-trunk coordination strategies that may be crucial to understanding its underlying mechanisms. In this paper, we present a biomechanical model of upright human posture that extends an existing four mass, sagittal plane, link-segment model to a five mass model including an independent head link. The new model was developed to analyze segmental body movements during dynamic posturography experiments in order to study head-trunk coordination strategies and their influence on sensory inputs to balance control. It was designed specifically to analyze data collected on the EquiTest (NeuroCom International, Clackamas, OR) computerized dynamic posturography system, where the task of maintaining postural equilibrium may be challenged under conditions in which the visual surround, support surface, or both are in motion. The performance of the model was tested by comparing its estimated ground reaction forces to those measured directly by support surface force transducers. We conclude that this model will be a valuable analytical tool in the search for mechanisms of balance control.

NASA Discipline Neuroscience↗

Resilient Control of Networked Microgrids Using Vertical Federated Reinforcement Learning: Designs and Real-Time Test-Bed Validations

Improving system-level resiliency of networked microgrids against adversarial cyber-attacks is an important aspect in the current regime of increased inverter-based resources (IBRs). To achieve that, this paper contributes in designing a hierarchical control layer, in conjunction with the existing control layers, resilient to adversarial attack signals. Considering model complexities, unknown dynamical behaviors of IBRs, and privacy issues regarding data sharing in multi-party-owned microgrids, designing such a control layer is non-trivial. Here, to tackle these issues, a novel federated reinforcement learning (Fed-RL) method is proposed. To grasp the interconnected dynamics of networked microgrids, the paper develops Federated Soft Actor-Critic (FedSAC) algorithm following the vertical structure of implementing Fed-RL. Next, utilizing the OpenAI Gym interface, we built a custom set-up in GridLAB-D/HELICS co-simulation platform, named Resilient RL Co-simulation (ResRLCoSIM), to train the RL agents with IEEE 123-bus benchmark comprising 3 interconnected microgrids. Finally, the learned policies in the simulation are transferred to the real-time hardware-in-the-loop (HIL) test-bed developed using the high-fidelity Hypersim platform. Finally, experiments show that the simulator-trained RL controllers achieve desirable performance with the test-bed platform, validating the minimization of the sim-to-real gap.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Hardware-in-the-Loop Evaluation of PV Inverter Grid Support on Hawaiian Electric Feeders

As more grid-connected photovoltaic (PV) inverters become compliant with evolving interconnections requirements, there is increased interest from utilities in understanding how to best deploy advanced grid-support functions (GSF) in the field. One efficient and cost-effective method to examine such deployment options is to leverage power hardware-in-the-loop (PHIL) testing methods, which combine the fidelity of hardware tests with the flexibility of computer simulation. This paper summarizes a study wherein two Hawaiian Electric feeder models were converted to real-time models using an OPAL-RT real-time digital testing platform, and integrated with models of GSF capable PV inverters based on characterization test data. The integrated model was subsequently used in PHIL testing to evaluate the effects of different fixed power factor and volt-watt control settings on voltage regulation of the selected feeders using physical inverters. Selected results are presented in this paper, and complete results of this study were provided as inputs for field deployment and technical interconnection requirements for grid-connected PV inverters on the Hawaiian Islands.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Design of Series-connected PV-powered Grid-forming Converters via Singular Perturbation

We report modular architectures that consist of several series-connected dc-ac converters have been a focal point of recent innovations in transformerless medium-voltage applications. In this paper, we consider an architecture consisting of dc-ac modules containing a quadruple active bridge dc-dc converter, which generates three floating dc links that feed grid-side dc-ac inverters. Practical implementation of such a converter module in PV systems requires a variety of controllers that collectively achieve maximum power point tracking, dc-link regulation, and ac-side power control. Design of such multi-loop systems is generally quite challenging due to the potential for destabilizing interactions among loops. Here we propose a design approach where singular perturbation theory is used to decompose the timescales at which each control loop operates and provides a systematic framework for parametric selection. Our approach also ensures system stability of multiple modules with identical controls connected in series across a grid. The paper concludes with experimental results of three 1000 W series-connected converter modules across a stiff grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters

Smart inverters (SIs) have demonstrated their potential to provide grid services for both transmission and distribution systems. One of these grid services, distribution network voltage regulation by SIs, has the potential to improve network voltage regulation through controlling the reactive and active power output of the SIs. Voltage regulation by SIs will be distributed and might be better suited to controlling local conditions to complement traditional voltage-regulating assets, e.g., tap-changing transformers, capacitor banks, and line voltage regulators. There is a gap in the literature on comparing the SI response characteristics when the SIs are controlled by a local controller or external control signals. This paper presents an experimental study to characterize SI reactive power regulation responses to two different control methods: autonomous control and remote dispatch. We found that SI reactive power regulation responses exhibit important differences between these methods in terms of delays and ramp rate. Finally, power-hardware-in-the-loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL test results show that the SI response characteristics for autonomous control and remote dispatch need to be considered when planning for distribution network voltage regulation using SIs.

autonomous control↗

Distributed Control and Optimization of Virtual Inertia in Power Systems

The integration of renewable energy sources into power grids through inverter-based resources (IBRs) reduces system inertia, leading to faster frequency dynamics and potential grid instability. This paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources during system disturbances, enhancing both system stability and economic performance. Furthermore, we integrate this approach with the traditional inertia placement problem, demonstrating its suitability for existing frameworks. We validate its effectiveness in a 4-bus test system and a two-area 8-bus test system, showcasing its potential for scalable, dynamic inertia management in low-inertia grids.

Yadav, Ajay [ORNL] (ORCID:000000016111881X)↗