Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mathematical Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Numerical and experimental studies on effects of moisture content on combustion characteristics of simulated municipal solid wastes in a fixed bed

Highlights: • The effects of moisture content on the burning process of MSW are investigated. • A two-dimensional mathematical model was built to simulate the combustion process. • Temperature distributions, process rates, gas species were measured and simulated. • The The conversion ratio of C/CO and N/NO in MSW are inverse to moisture content. - Abstract: In order to reveal the features of the combustion process in the porous bed of a waste incinerator, a two-dimensional unsteady state model and experimental study were employed to investigate the combustion process in a fixed bed of municipal solid waste (MSW) on the combustion process in a fixed bed reactor. Conservation equations of the waste bed were implemented to describe the incineration process. The gas phase turbulence was modeled using the k–ε turbulent model and the particle phase was modeled using the kinetic theory of granular flow. The rate of moisture evaporation, devolatilization rate, and char burnout was calculated according to the waste property characters. The simulation results were then compared with experimental data for different moisture content of MSW, which shows that the incineration process of waste in the fixed bed is reasonably simulated. The simulation results of solid temperature, gas species and process rate in the bed are accordant with experimental data. Due to the high moisture content of fuel, moisture evaporation consumes a vast amount of heat, and the evaporation takes up most of the combustion time (about 2/3 of the whole combustion process). The whole bed combustion process reduces greatly as MSW moisture content increases. The experimental and simulation results provide direction for design and optimization of the fixed bed of MSW.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Power Minimization techniques for Networked Data Centers.

Our objective is to develop a mathematical model to optimize energy consumption at multiple levels in networked data centers, and develop abstract algorithms to optimize not only individual servers, but also coordinate the energy consumption of clusters of servers within a data center and across geographically distributed data centers to minimize the overall energy cost and consumption of brown energy of an enterprise. In this project, we have formulated a variety of optimization models, some stochastic others deterministic, and have obtained a variety of qualitative results on the structural properties, robustness, and scalability of the optimal policies. We have also systematically derived from these models decentralized algorithms to optimize energy efficiency, analyzed their optimality and stability properties. Finally, we have conducted preliminary numerical simulations to illustrate the behavior of these algorithms. We draw the following conclusion. First, there is a substantial opportunity to minimize both the amount and the cost of electricity consumption in a network of datacenters, by exploiting the fact that traffic load, electricity cost, and availability of renewable generation fluctuate over time and across geographical locations. Judiciously matching these stochastic processes can optimize the tradeoff between brown energy consumption, electricity cost, and response time. Second, given the stochastic nature of these three processes, real-time dynamic feedback should form the core of any optimization strategy. The key is to develop decentralized algorithms that can be implemented at different parts of the network as simple, local algorithms that coordinate through asynchronous message passing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correction Factors Applied to Finger Dosimetry: A Theoretical Assessment of Appropriate Values for Use in Handling Radiopharmaceuticals

United States Nuclear Regulatory Commission (USNRC) regulations limit the dose to the skin to 500 mSv per year. This is also the dose limit recommended by the International Commission on Radiological Protection (ICRP). The operational quantity recommended by ICRP for quantifying dose to the skin is the personal dose equivalent, Hp(0.07) and is identical to NRC s shallow dose equivalent, Hs, also measured at a skin depth of 7 mg cm 2. However, whereas ICRP recommends averaging the dose to the skin over an area of 1 cm2 regardless of the size of the exposed area of skin, USNRC requires the shallow dose equivalent to be averaged over 10 cm2. To monitor dose to the skin of the hands of workers handling radioactive materials and particularly in radiopharmaceutical manufacturing facilities, which is the focus of this work, workers are frequently required to wear finger ring dosimeters. The dosimeters monitor the dose at the location of the sensitive element, but this is not the dose required to show compliance (i.e., the dose averaged over the highest exposed contiguous 10 cm2 of skin). Therefore, it may be necessary to apply a correction factor that enables estimation of the required skin dose from the dosimeter reading. This work explored the effects of finger ring placement and of the geometry of the radioactive materials being handled by the worker on the relationship between the dosimeter reading and the desired average dose. A mathematical model of the hand was developed for this purpose that is capable of positioning the fingers in any desired grasping configuration, thereby realistically modeling manipulation of any object. The model was then used with the radiation transport code MCNP to calculate the dose distribution on the skin of the hand when handling a variety of radioactive vials and syringes, as well as the dose to the dosimeter element. Correction factors were calculated using the results of these calculations and examined for any patterns that may be useful in establishing an appropriate correction factor for this type of work. It was determined that a correction factor of one applied to the dosimeter reading, with the dosimeter placed at the base of the middle finger, provides an adequate estimate of the required average dose during a monitoring period for most commonly encountered geometries. Different correction factors may be required for exceptional or unusual source geometries and must be considered on a case-by-case basis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 09: Impact of the distance of reflective markers from linac isocenter on the positional accuracy of an infrared tracking system

Purpose: The HexaPOD™ six degree of freedom couchtop is equipped with an optical tracking system, consisting of a stereoscopic camera and a reference frame (RF) carrying infrared reflective markers. The manufacturer recommends placing the RF within 50 cm from linac isocenter (ISO), which is a serious limitation since the RF does not fit around the shoulders of most brain patients. This study quantifies the impact of extended RF distances from ISO on positional accuracy. Methods: An in-house tool with an estimated resolution of 0.3 mm and 0.1° was used. It is a large cube and a mathematical model of HexaPOD motion to determine the intersection of room lasers with the ruled cube edges. Combinations of translations (±1 and ±3 cm) and rotations (±2.5°) were executed on two HexaPOD couchtops for multiple RF distances from ISO (35 to 77 cm). For each combination, ten laser readings were fed into a least squares algorithm to determine the executed translations and rotations while minimizing operator reading errors. Results: The usable tracking volume is up to an RF distance of 82 cm from ISO. Positional accuracy of the HexaPOD/iGuide system is 0.6 mm and 0.1° (95% confidence). Positional accuracy variations versus RF distance from ISO are statistically insignificant (p = 0.05). Our results generally confirm recent internal estimates by the manufacturer (for future release). Conclusions: RF distances up to 77 cm from ISO are clinically acceptable, provided performing a patient safety study with a verification scan.

60 APPLIED LIFE SCIENCES↗

Analysis of SO{sub 2} sorption capacity of rice husk ash (RHA)/CaO/NaOH sorbents using response surface methodology (RSM): untreated and pretreated RHA

The SO{sub 2} sorption capacity (SSC) of sorbents prepared from rice husk ash (RHA) with NaOH as additive was studied in a fixed-bed reactor. Rice husk ash is produced by burning rice husks at about 300{sup o}C and was chosen as a source of siliceous material, abundantly available in Malaysia. The sorbents were prepared using a water hydration method by slurrying RHA, CaO, and NaOH. Response surface methodology (RSM) based on four-variable central composite face centered design (CCFCD) was employed in the synthesis of the sorbents. The correlation between the sorbent SSC (as response) with four independent sorbent preparation variables, i.e. hydration period, RHA/CaO ratio, NaOH amount, and drying temperature, were presented as empirical mathematical models. Among all the variables studied, the amount of NaOH used was found to be the most significant variable affecting the SSC of the sorbents prepared. The SSC for sorbent prepared with the addition of NaOH was found to be significantly higher than sorbents prepared without NaOH. This is probably because NaOH is a deliquescent material, and its existence increases the amount of water collected on the surface of the sorbent, a condition required for sorbent-SO{sub 2} reaction to occur at low temperature. The effect of further treatment of RHA at 600{sup o}C was also investigated. Although pretreated RHA sorbents demonstrated higher SSC as compared to untreated RHA sorbents, nevertheless, at optimum conditions, sorbents prepared from untreated RHA was found to be more favorable due to practical and economic concerns. 33 refs., 3 figs., 1 tab.

09 BIOMASS FUELS↗

Robustness analysis of an air heating plant and control law by using polynomial chaos

This paper presents a robustness analysis of an air heating plant with a multivariable closed-loop control law by using the polynomial chaos methodology (MPC). The plant consists of a PVC tube with a fan in the air input (that forces the air through the tube) and a mass flux sensor in the output. A heating resistance warms the air as it flows inside the tube, and a thermo-couple sensor measures the air temperature. The plant has thus two inputs (the fan's rotation intensity and heat generated by the resistance, both measured in percent of the maximum value) and two outputs (air temperature and air mass flux, also in percent of the maximal value). The mathematical model is obtained by System Identification techniques. The mass flux sensor, which is nonlinear, is linearized and the delays in the transfer functions are properly approximated by non-minimum phase transfer functions. The resulting model is transformed to a state-space model, which is used for control design purposes. The multivariable robust control design techniques used is the LQG/LTR, and the controllers are validated in simulation software and in the real plant. Finally, the MPC is applied by considering some of the system's parameters as random variables (one at a time, and the system's stochastic differential equations are solved by expanding the solution (a stochastic process) in an orthogonal basis of polynomial functions of the basic random variables. This method transforms the stochastic equations in a set of deterministic differential equations, which can be solved by traditional numerical methods (That is the MPC). Statistical data for the system (like expected values and variances) are then calculated. The effects of randomness in the parameters are evaluated in the open-loop and closed-loop pole's positions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Linear and nonlinear verification of gyrokinetic microstability codes

Verification of nonlinear microstability codes is a necessary step before comparisons or predictions of turbulent transport in toroidal devices can be justified. By verification we mean demonstrating that a code correctly solves the mathematical model upon which it is based. Some degree of verification can be accomplished indirectly from analytical instability threshold conditions, nonlinear saturation estimates, etc., for relatively simple plasmas. However, verification for experimentally relevant plasma conditions and physics is beyond the realm of analytical treatment and must rely on code-to-code comparisons, i.e., benchmarking. The premise is that the codes are verified for a given problem or set of parameters if they all agree within a specified tolerance. True verification requires comparisons for a number of plasma conditions, e.g., different devices, discharges, times, and radii. Running the codes and keeping track of linear and nonlinear inputs and results for all conditions could be prohibitive unless there was some degree of automation. We have written software to do just this and have formulated a metric for assessing agreement of nonlinear simulations. We present comparisons, both linear and nonlinear, between the gyrokinetic codes GYRO[J. Candy and R. E. Waltz, J. Comput. Phys. 186, 545 (2003)] and GS2[W. Dorland, F. Jenko, M. Kotschenreuther, and B. N. Rogers, Phys. Rev. Lett. 85, 5579 (2000)]. We do so at the mid-radius for the same discharge as in earlier work [C. Holland, A. E. White, G. R. McKee, M. W. Shafer, J. Candy, R. E. Waltz, L. Schmitz, and G. R. Tynan, Phys. Plasmas 16, 052301 (2009)]. The comparisons include electromagnetic fluctuations, passing and trapped electrons, plasma shaping, one kinetic impurity, and finite Debye-length effects. Results neglecting and including electron collisions (Lorentz model) are presented. We find that the linear frequencies with or without collisions agree well between codes, as do the time averages of the nonlinear fluxes without collisions. With collisions, the differences between the time-averaged fluxes are larger than the uncertainties defined as the oscillations of the fluxes, with the GS2 fluxes consistently larger (or more positive) than those from GYRO. However, the electrostatic fluxes are much smaller than those without collisions (the electromagnetic energy flux is negligible in both cases). In fact, except for the electron energy fluxes, the absolute magnitudes of the differences in fluxes with collisions are the same or smaller than those without. None of the fluxes exhibit large absolute differences between codes. Beyond these results, the specific linear and nonlinear benchmarks proposed here, as well as the underlying methodology, provide the basis for a wide variety of future verification efforts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status and Targets for Polymer-Based Solid-State Batteries for Electric Vehicle Applications

There is growing interest in the development of Li-metal-based solid state batteries, driven by their promise in improving the energy density to satisfy electric vehicle requirements. In this work, we examine the status of Solid polymer electrolytes (SPEs) based solid state batteries for electric vehicle applications using a continuum scale mathematical model. We examine LiFePO4(LFP) cathode/lithium metal anode batteries containing three different electrolytes, namely (1) a liquid electrolyte, (2) the polystyrene-b-poly(ethylene oxide) (SEO) block copolymer electrolyte, and (3) a single-ion conducting (SIC) block copolymer electrolyte, with the liquid electrolyte serving as the baseline for the comparison. By using an optimization procedure, we assemble "virtual" batteries to identify the optimal design that maximizes energy density while allowing the power requirements of electric vehicles (EVs) to be satisfied. Results show the present status of different SPEs are still below what is considered acceptable and further improvements are needed to achieve electric vehicle targets. The optimization studies conducted here show that for low transference number electrolytes (similar to 0.2) the conductivity target is 5 x 10(-3)S cm(-1), while for a unity transference number electrolyte this target decreases to 4 x 10(-4)S cm(-1). These targets provide guidance for polymer synthesis researchers to develop better polymers for use in EVs.

25 ENERGY STORAGE↗

Simulation of the subnanosecond cutoff of current in high-power semiconductor diodes

The subnanosecond cutoff of high-density current in the structure of a semiconductor opening-switch diode is investigated within a physico-mathematical model. The model takes into account the space charge and the effect of the electric field, temperature, electron-hole scattering, and scattering by ionized impurities on the carrier mobility. It is established that subnanosecond cutoff of current with a density of several kA/cm{sup 2} occurs at a p-n junction depth exceeding 180 {mu}m, forward pumping time less than 60 ns, and reverse pumping time less than 20 ns. This process is due to the formation of three high-field regions in the stage of current cutoff. Two regions, expanding with a nearly constant velocity, are located in the p region, and the third one, slowly expanding, is in the n region. It is shown that, to implement subnanosecond current cut-off, a set of conditions for the circuit parameters (determining the pump current duration and density) and the dopant profile in the semiconductor structure should be satisfied simultaneously. The simulation results are compared with the experimental data.

36 MATERIALS SCIENCE↗

Regulation of flow through a T-Shaped open cavity by temperature dependent P, PI, and PID controllers

P (proportional), PI (proportional-integral), and PID (proportional-integral-derivative) controllers are popular means of controlling industrial processes. Due to superior response, accuracy, and stable performance, PID controllers are mostly used in control systems. This paper presents a mathematical model and subsequent response analysis regarding regulation of flow in mixed convection through a T-shaped open cavity by temperature dependent controllers. The T-shaped cavity has cold top and hot bottom walls, while air is flowing through the inlet at surrounding temperature. The inflow is regulated by a controlled gate which operates according to the signal received from the controller. Values of proportional gain (k{sub p}), integral gain (k{sub i}), and derivative gain (k{sub d}) are varied to obtain the desired system response and to ensure a stable system with fastest response. At first, only P controller is used and eventually PI and finally PID control scheme is applied for controller tuning. Tuning of different controllers (P, PI, and PID) are carried out systematically based on the reference temperature which is continuously monitored at a certain location inside the cavity. It is found that PID controller performs better than P or PI controller.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mapping the performance of PV modules, effects of module type and data averaging

A method is presented for estimating the energy yield of photovoltaic (PV) modules at arbitrary locations in a large geographical area. The method applies a mathematical model for the energy performance of PV modules as a function of in-plane irradiance and module temperature and combines this with solar irradiation estimates from satellite data and ambient temperature values from ground station measurements. The method is applied to three different PV technologies: crystalline silicon, CuInSe{sub 2} and CdTe based thin-film technology in order to map their performance in fixed installations across most of Europe and to identify and quantify regional performance factors. It is found that there is a clear technology dependence of the geographical variation in PV performance. It is also shown that using long-term average values of irradiance and temperature leads to a systematic positive bias in the results of up to 3%. It is suggested to use joint probability density functions of temperature and irradiance to overcome this bias. (author)

14 SOLAR ENERGY↗

Kinetics of the active medium of a He-Sr{sup +} recombination laser: 2. Achievable energy characteristics

The mechanisms limiting the improvement of the energy characteristics of He-Sr{sup +} recombination lasers with increasing pressure, active volume, and pulse repetition rate are analysed. It is found that the existence of optimal pressure is related to the cooling rate limitation for electrons at high pressures arising from the heating action of the trailing edge of a current pulse and that the average power saturation with increasing discharge tube diameter and pulse repetition rate occurs due to the formation of radial nonuniformity as well as due to the growth of the electron temperature in the afterglow. Calculations involving a mathematical model showed that the attainable maximum of the linear power is equal to {approx}6.2 W m{sup -1} for self-heating active elements of BeO ceramics and to {approx}7.8 W m{sup -1} with its surface blackened, to {approx}7.7 W m{sup -1} for an independent introduction of the vapour and to {approx}9.4 W m{sup -1} in combination with blackening, to {approx}17 W m{sup -1} for intense forced cooling of the active elements of cylindrical geometry and to {approx}29 W m{sup -1} with active elements of rectangular cross section for a wall dimension ratio of 1:3. We demonstrate the feasibility of raising the output power by {approx}21% in the excitation of the active medium by pulse bursts with a short interpulse separation. (lasers and amplifiers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new process sensitivity index to identify important system processes under process model and parametric uncertainty

Hydrological models are always composed of multiple components that represent processes key to intended model applications. When a process can be simulated by multiple conceptual-mathematical models (process models), model uncertainty in representing the process arises. While global sensitivity analysis methods have been widely used for identifying important processes in hydrologic modeling, the existing methods consider only parametric uncertainty but ignore the model uncertainty for process representation. To address this problem, this study develops a new method to probe multimodel process sensitivity by integrating the model averaging methods into the framework of variance-based global sensitivity analysis, given that the model averaging methods quantify both parametric and model uncertainty. A new process sensitivity index is derived as a metric of relative process importance, and the index includes variance in model outputs caused by uncertainty in both process models and model parameters. For demonstration, the new index is used to evaluate the processes of recharge and geology in a synthetic study of groundwater reactive transport modeling. The recharge process is simulated by two models that converting precipitation to recharge, and the geology process is also simulated by two models of different parameterizations of hydraulic conductivity; each process model has its own random parameters. The new process sensitivity index is mathematically general, and can be applied to a wide range of problems in hydrology and beyond.

Dai, Heng↗

Breaking Through Historical Biases in Performance Assessments - 18056

Performance assessments (referred to as safety assessments internationally), which include mathematical modeling of natural and engineered systems for many hundreds and thousands of years, play an important role in decision-making for disposal of radioactive waste and cleanup of sites and facilities contaminated with radioactive material. These decisions can involve options costing hundreds of millions or even billions of dollars. Thus, it is critical to understand the underlying assumptions behind regulatory and technical aspects of these assessments to better understand and communicate the basis for decisions. Policy and technical biases deliberately built into early assessment approaches allowed safety margin to account for uncertainties known to be present, but not quantitatively assessed. Many of these biases (e.g., regulatory standards, human habits, effectiveness of waste forms, inadvertent intrusion assumptions, etc.) continue to exist in spite of advances in technical approaches and knowledge. These built-in biases, often not effectively communicated, can lead to misleading interpretation of results and potentially influence public confidence and costly regulatory decisions regarding the safety of a disposal facility or a closure action. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surface complexation of neptunium (V) onto whole cells and cell componets of Shewanella alga

We systematically quantified surface complexation of neptunium(V) onto whole cells of Shewanella alga strain BrY and onto cell wall and extracellular polymeric substances (EPS) of S. alga. We first performed acid and base titrations and used the mathematical model FITEQL with constant-capacitance surface-complexation to determine the concentrations and deprotonation constants of specific surface functional groups. Deprotonation constants most likely corresponded to a carboxyl site associated with amino acids (pK{sub a} {approx} 2.4), a carboxyl group not associated with amino acids (pK{sub a} {approx} 5), a phosphoryl site (pK{sub a} {approx} 7.2), and an amine site (pK{sub a} > 10). We then carried out batch sorption experiments with Np(V) and each of the S. alga components at different pHs. Results show that solution pH influenced the speciation of Np(V) and each of the surface functional groups. We used the speciation sub-model of the biogeochemical model CCBATCH to compute the stability constants for Np(V) complexation to each surface functional group. The stability constants were similar for each functional group on S. alga bacterial whole cells, cell walls, and EPS, and they explain the complicated sorption patterns when they are combined with the aqueous-phase speciation of Np(V). For pH < 8, NpO{sub 2}{sup +} was the dominant form of Np(V), and its log K values for the low-pK{sub a} carboxyl, other carboxyl, and phosphoryl groups were 1.75, 1.75, and 2.5 to 3.1, respectively. For pH greater than 8, the key surface ligand was amine >XNH3+, which complexed with NpO{sub 2}(CO{sub 3}){sub 3}{sup 5-}. The log K for NpO{sub 2}(CO{sub 3}){sub 3}{sup 5-} complexed onto the amine groups was 3.1 to 3.6. All of the log K values are similar to those of Np(V) complexes with aqueous carboxyl and N-containing carboxyl ligands. These results point towards the important role of surface complexation in defining key actinide-microbiological interactions in the subsurface.

55↗

Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI{sub 100} as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI{sub 100} is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, {sigma}. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI{sub 100} calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good agreement between the measured dose profile data and the fitted Gaussian functions. The solid-state detector had no energy dependence--within the energy range of interest--and the analytical model succeeded in reproducing the absolute dose values obtained with the pencil ion chamber. For the case of large cone-beam single axial scans, the quantity that better characterizes the total energy imparted to the patient is the weighted dose profile integral (DPI{sub w}). The DPI{sub w} can be easily determined from the two parameters that define the Gaussian functions: f(0) and {sigma}. The authors found that the DLP underestimated the total energy imparted to the patient by more than 20%. The authors also found that the calculated CT dosimetric quantities were higher than those displayed on the scanner console. Conclusions: The authors described and validated a method to assess radiation dose in large cone-beam single axial scans. This method offers a simple and more accurate estimation of the total energy imparted to the patient, thus offering the possibility to update the bridge between CT dosimetry and the estimation of the effective dose for cone-beam CT examinations in radiology, nuclear medicine, and radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Stefan problem of solidification of ternary systems in the presence of moving phase transition regions

The process of solidification of ternary systems in the presence of moving phase transition regions has been investigated theoretically in terms of the nonlinear equation of the liquidus surface. A mathematical model is developed and an approximate analytical solution to the Stefan problem is constructed for a linear temperature profile in two-phase zones. The temperature and impurity concentration distributions are determined, the solid-phase fractions in the phase transition regions are obtained, and the laws of motion of their boundaries are established. It is demonstrated that all boundaries move in accordance with the laws of direct proportionality to the square root of time, which is a general property of self-similar processes. It is substantiated that the concentration of an impurity of the substance undergoing a phase transition only in the cotectic zone increases in this zone and decreases in the main two-phase zone in which the other component of the substance undergoes a phase transition. In the process, the concentration reaches a maximum at the interface between the main two-phase zone and the cotectic two-phase zone. The revealed laws of motion of the outer boundaries of the entire phase transition region do not depend on the amount of the components under consideration and hold true for crystallization of a multicomponent system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of immune escape mutations on HIV-1 fitness in the context of the cognate transmitted/founder genome

Background: A modest change in HIV-1 fitness can have a significant impact on viral quasispecies evolution and viral pathogenesis, transmission and disease progression. To determine the impact of immune escape mutations selected by cytotoxic T lymphocytes (CTL) on viral fitness in the context of the cognate transmitted/founder (T/F) genome, we developed a new competitive fitness assay using molecular clones of T/F genomes lacking exogenous genetic markers and a highly sensitive and precise parallel allele-specific sequencing (PASS) method. Results: The T/F and mutant viruses were competed in CD4+ T-cell enriched cultures, relative proportions of viruses were assayed after repeated cell-free passage, and fitness costs were estimated by mathematical modeling. Naturally occurring HLA B57-restricted mutations involving the TW10 epitope in Gag and two epitopes in Tat/Rev and Env were assessed independently and together. Compensatory mutations which restored viral replication fitness were also assessed. A principal TW10 escape mutation, T242N, led to a 42% reduction in replication fitness but V247I and G248A mutations in the same epitope restored fitness to wild-type levels. No fitness difference was observed between the T/F and a naturally selected variant carrying the early CTL escape mutation (R355K) in Env and a reversion mutation in the Tat/Rev overlapping region. Conclusions: These findings reveal a broad spectrum of fitness costs to CTL escape mutations in T/F viral genomes, similar to recent findings reported for neutralizing antibody escape mutations, and highlight the extraordinary plasticity and adaptive potential of the HIV-1 genome. Analysis of T/F genomes and their evolved progeny is a powerful approach for assessing the impact of composite mutational events on viral fitness.

Transmitted/founder virus↗