Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Identifying Optimal Temporal Scale for the Correlation of AOD and Ground Measurements of PM2.5 to Improve the Modeling Performance in a Real-Time Air Quality Estimation System

Aerosol optical depth (AOD), derived from satellite measurements using Moderate Resolution Imaging Spectrometer (MODIS), offers indirect estimates of particle matter. Research shows a significant positive correlation between satellite-based measurements of AOD and ground-based measurements of particulate matter with aerodynamic diameter less than or equal to 2.5 micrometers (PM2.5). In addition, satellite observations have also shown great promise in improving estimates of PM2.5 air quality surface. Research shows that correlations between AOD and ground PM2.5 are affected by a combination of many factors such as inherent characteristics of satellite observations, terrain, cloud cover, height of the mixing layer, and weather conditions, and thus might vary widely in different regions, different seasons, and even different days in a same location. Analysis of correlating AOD with ground measured PM2.5 on a day-to-day basis suggests the temporal scale, a number of immediate latest days for a given run's day, for their correlations needs to be considered to improve air quality surface estimates, especially when satellite observations are used in a real-time pollution system. The second reason is that correlation coefficients between AOD and ground PM2.5 cannot be predetermined and needs to be calculated for each day's run for a real-time system because the coefficients can vary over space and time. Few studies have been conducted to explore the optimal way to apply AOD data to improve model accuracies of PM2.5 surface estimation in a real-time air quality system. This paper discusses the best temporal scale to calculate the correlation of AOD and ground particle matter data to improve the results of pollution models in real-time system.

Li,Hui↗

A Neural Optimizer With Decision-Focused Learning for Optimal Energy Storage Operation

Here, this article introduces a neural optimizer-based framework for optimizing battery energy storage system (BESS) control for grid services, including demand charge and energy cost reduction. By leveraging decision-focused learning (DFL), the proposed framework ensures seamless integration and adaptation, significantly enhancing control performance. A patch time-series transformer is employed for peak load forecasting, incorporating aleatoric uncertainty quantification to account for forecasting uncertainties within the decision-making process. The framework utilizes a solver-in-the-loop approach to generate optimal BESS actions, which are then used to train the neural optimizer-based agent. By co-optimizing both BESS operational modes and output power within the NN, the system achieves improved performance and robustness. After initial training, the forecasting and control models are jointly fine-tuned to account for forecasting errors, further improving decision precision and efficiency through DFL. Case studies are performed to validate the performance of the framework using multiple real-world datasets, demonstrating superior performance in monthly peak load forecasting compared to state-of-the-art models. In addition, the results are compared against existing decision-making approaches. The results demonstrate a reduction in monthly peak forecasting error by approximately 15% across various performance measures and achieve an optimization gap for BESS operation that is about three times smaller compared to existing methods.

Kim, Hyeonjin [Pacific Northwest National Laborato↗

Optimal configurations of filter cavity in future gravitational-wave detectors

Sensitivity of future laser interferometric gravitational wave detectors can be improved using squeezed light with frequency-dependent squeeze angle and/or amplitude, which can be created using additional so-called filter cavities. Here we compare performances of several variants of this scheme, proposed during the last few years, assuming the case of a single relatively short (tens of meters) filter cavity suitable for implementation already during the life cycle of the second-generation detectors, like Advanced LIGO. Using numerical optimization, we show that the phase filtering scheme proposed by Kimble et al [H. J. Kimble, Yu. Levin, A. B. Matsko, K. S. Thorne, and S. P. Vyatchanin, Phys. Rev. D 65, 022002 (2001).] looks like the best candidate for this scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the structure of gallium-arsenide-based detectors with taking into account recombination losses

The model describing the physical processes accompanying the interaction of heavy charged particles with an ionizing-radiation semiconductor detector is proposed. The problem of optimization of electrical characteristics and construction of the detector cell is solved. The model makes it possible to calculate the output current of the detector as a function of its active-region's thickness and the voltage applied across the sensor under conditions of the presence of recombination processes.

36 MATERIALS SCIENCE↗

Identifying Shocked Feldspar on Mars Using Perseverance Spectroscopic Instruments: Implications for Geochronology Studies on Returned Samples

The Perseverance rover (Mars 2020) mission, the first step in NASA’s Mars Sample Return (MSR) program, will select samples for caching based on their potential to improve understanding Mars’ astrobiological, geological, geochemical, and climatic evolution. Geochronologic analyses will be among the key measurements planned for returned samples. Assessing a sample’s shock history will be critical because shock metamorphism could influence apparent sample age. Shock effects in one Mars-relevant mineral class, plagioclase feldspar, have been well- documented using various spectroscopy techniques (thermal infrared reflectance, emission, and transmission spectroscopy, Raman, and luminescence). A subset of these data will be obtained with the SuperCam and SHERLOC (Scanning Habitable Environments with Raman & Luminescence for Organics & Chemicals) instruments onboard Perseverance to inform caching decisions for MSR. Here, we review shock indicators in plagioclase feldspar as revealed in Raman, luminescence, and IR spectroscopy lab data, with an emphasis on Raman spectroscopy. We consider how this information may inform caching decisions for selecting optimal samples for geochronology measurements. We then identify challenges and make recommendations for both in situ measurements performed with SuperCam and SHERLOC and for supporting lab studies to enhance the success of geochronologic analyses after return to Earth.

mars↗

A Requirements-Driven Optimization Method for Acoustic Treatment Design

Acoustic treatment designers have long been able to target specific noise sources inside turbofan engines. Facesheet porosity and cavity depth are key design variables of perforate-over-honeycomb liners that determine levels of noise suppression as well as the frequencies at which suppression occurs. Layers of these structures can be combined to create a robust attenuation spectrum that covers a wide range of frequencies. Looking to the future, rapidly-emerging additive manufacturing technologies are enabling new liners with multiple degrees of freedom, and new adaptive liners with variable impedance are showing promise. More than ever, there is greater flexibility and freedom in liner design. Subject to practical considerations, liner design variables may be manipulated to achieve a target attenuation spectrum. But characteristics of the ideal attenuation spectrum can be difficult to know. Many multidisciplinary system effects govern how engine noise sources contribute to community noise. Given a hardwall fan noise source to be suppressed, and using an analytical certification noise model to compute a community noise measure of merit, the optimal attenuation spectrum can be derived using multidisciplinary systems analysis methods. The subject of this paper is an analytical method that derives the ideal target attenuation spectrum that minimizes noise perceived by observers on the ground.

Aircraft Noise↗

Optimization of the first order gradiometer for small sample magnetization measurements using pulse integrating magnetometer

In the paper we present an analytical calculation method for determination of the sensitivity of a pulse field magnetometer working with a first order gradiometer. Our considerations here are especially focused on a case of magnetic moment measurements of very small samples. Derived in the work analytical equations allow for a quick estimation of the magnetometer's sensitivity and give also the way to its calibration using the sample simulation coil method. On the base of the given in the paper calculations we designed and constructed a simple homemade magnetometer and performed its sensitivity calibration.

36 MATERIALS SCIENCE↗

A Preliminary Comparison of Three Dimensional Particle Tracking and Sizing using Plenoptic Imaging and Digital In-line Holography

Digital in-line holography and plenoptic photography are two techniques for single-shot, volumetric measurement of 3D particle fields. Here we present a preliminary comparison of the two methods by applying plenoptic imaging to experimental configurations that have been previously investigated with digital in-line holography. These experiments include the tracking of secondary droplets from the impact of a water drop on a thin film of water and tracking of pellets from a shotgun. Both plenoptic imaging and digital in-line holography successfully quantify the 3D nature of these particle fields. This includes measurement of the 3D particle position, individual particle sizes, and three-component velocity vectors. For the initial processing methods presented here, both techniques give out-of-plane positional accuracy of approximately 1-2 particle diameters. For a fixed image sensor, digital holography achieves higher effective in-plane spatial resolutions. However, collimated and coherent illumination makes holography susceptible to image distortion through index of refraction gradients, as demonstrated in the shotgun experiments. On the other hand, plenotpic imaging allows for a simpler experimental configuration. Furthermore, due to the use of diffuse, white-light illumination, plenoptic imaging is less susceptible to image distortion in the shotgun experiments. Additional work is needed to better quantify sources of uncertainty, particularly in the plenoptic experiments, as well as develop data processing methodologies optimized for the plenoptic measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Preliminary Comparison of Three Dimensional Particle Tracking and Sizing using Plenoptic Imaging and Digital In-line Holography [PowerPoint]

Digital in-line holography and plenoptic photography are two techniques for single-shot, volumetric measurement of 3D particle fields. Here we present a preliminary comparison of the two methods by applying plenoptic imaging to experimental configurations that have been previously investigated with digital in-line holography. These experiments include the tracking of secondary droplets from the impact of a water drop on a thin film of water and tracking of pellets from a shotgun. Both plenoptic imaging and digital in-line holography successfully quantify the 3D nature of these particle fields. This includes measurement of the 3D particle position, individual particle sizes, and three-component velocity vectors. For the initial processing methods presented here, both techniques give out-of-plane positional accuracy of approximately 1-2 particle diameters. For a fixed image sensor, digital holography achieves higher effective in-plane spatial resolutions. However, collimated and coherent illumination makes holography susceptible to image distortion through index of refraction gradients, as demonstrated in the shotgun experiments. On the other hand, plenotpic imaging allows for a simpler experimental configuration. Furthermore, due to the use of diffuse, white-light illumination, plenoptic imaging is less susceptible to image distortion in the shotgun experiments. Additional work is needed to better quantify sources of uncertainty, particularly in the plenoptic experiments, as well as develop data processing methodologies optimized for the plenoptic measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast electron diffraction with radio-frequency compressed electron pulses

We report on the complete characterization of time resolution in an ultrafast electron diffraction (UED) instrument based on radio-frequency electron pulse compression. The temporal impulse response function of the instrument was determined directly in pump-probe geometry by performing electron-laser pulse cross-correlation measurements using the ponderomotive interaction. With optimal settings, a stable impulse response of 334{+-}10 fs was measured at a bunch charge of 0.1 pC (6.24 Multiplication-Sign 10{sup 5} electrons/pulse); a dramatic improvement compared to performance without pulse compression. Phase stability currently limits the impulse response of the UED diffractometer to the range of 334-500 fs, for bunch charges ranging between 0.1 and 0.6 pC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring Irradiance for Bifacial PV Systems

The advent of bifacial PV systems drives new requirements for irradiance measurement at PV projects for monitoring and assessment purposes. While there are several approaches, there is still no uniform guidance for what irradiance parameters to measure and for the optimal selection and placement of irradiance sensors at bifacial arrays. Standards are emerging to address these topics but are not yet available. In this paper we review approaches to bifacial irradiance monitoring which are being discussed in the research literature and pursued in early systems, to provide a preliminary guide and framework for developers planning bifacial projects.

bifacial↗

Measuring Irradiance for Bifacial PV Systems: Preprint

The advent of bifacial PV systems drives new requirements for irradiance measurement at PV projects for monitoring and assessment purposes. While there are several approaches, there is still no uniform guidance for what irradiance parameters to measure and for the optimal selection and placement of irradiance sensors at bifacial arrays. Standards are emerging to address these topics but are not yet available. In this paper we review approaches to bifacial irradiance monitoring which are being discussed in the research literature and pursued in early systems, to provide a preliminary guide and framework for developers planning bifacial projects.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Plasma impurities observed by a pulse height analysis diagnostic during the divertor campaign of the Wendelstein 7-X stellarator

The paper reports on the optimization process of the soft X-ray pulse height analyzer installed on the Wendelstein 7-X (W7-X) stellarator. It is a 3-channel system that records X-ray spectra in the range from 0.6 to 19.6 keV. X-ray spectra, with a temporal and spatial resolution of 100 ms and 2.5 cm (depending on selected slit sizes), respectively, are line integrated along a line-of-sight that crosses near to the plasma center. In the second W7-X operation phase with a carbon test divertor unit, we report light impurities, e.g., carbon and oxygen, were observed as well as mid- to high-Z elements, e.g., sulfur, chlorine, chromium, manganese, iron, and nickel. In addition, X-ray lines from several tracer elements have been observed after the laser blow-off injection of different impurities, e.g., silicon, titanium, and iron, and during discharges with prefill or a gas puff of neon or argon. These measurements were achieved by optimizing light absorber-foil selection, which defines the detected energy range, and remotely controlled pinhole size, which defines photon flux. The identification of X-ray lines was confirmed by other spectroscopic diagnostics, e.g., by the High-Efficiency XUV Overview Spectrometer, HEXOS, and high-resolution X-ray imaging spectrometer, HR-XIS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal Estimation Inversion of Ionospheric Electron Density from GNSS-POD Limb Measurements: Part I-Algorithm and Morphology

GNSS-LEO radio links from Precise Orbital Determination (POD) and Radio Occultation (RO) antennas have been used increasingly in characterizing the global 3D distribution and variability of ionospheric electron density (N e ). In this study, we developed an optimal estimation (OE) method to retrieve N e profiles from the slant total electron content (hTEC) measurements acquired by the GNSS-POD links at negative elevation angles (ε < 0°). Although both OE and onion-peeling (OP) methods use the Abel weighting function in the N e inversion, they are significantly different in terms of performance in the lower ionosphere. The new OE results can overcome the large N e oscillations, sometimes negative values, seen in the OP retrievals in the E-region ionosphere. In the companion paper in this Special Issue, the HmF2 and NmF2 from the OE retrieval are validated against ground-based ionosondes and radar observations, showing generally good agreements in NmF2 from all sites. Nighttime hmF2 measurements tend to agree better than the daytime when the ionosonde heights tend to be slightly lower. The OE algorithm has been applied to all GNSS-POD data acquired from the COSMIC-1 (2006–2019), COSMIC-2 (2019–present), and Spire (2019–present) constellations, showing a consistent ionospheric N e morphology. The unprecedented spatiotemporal sampling of the ionosphere from these constellations now allows a detailed analysis of the frequency–wavenumber spectra for the N e variability at different heights. In the lower ionosphere (~150 km), we found significant spectral power in DE1, DW6, DW4, SW5, and SE4 wave components, in addition to well-known DW1, SW2, and DE3 waves. In the upper ionosphere (~450 km), additional wave components are still present, including DE4, DW4, DW6, SE4, and SW4. The co-existence of eastward- and westward-propagating wave4 components implies the presence of a stationary wave4 (SPW4), as suggested by other earlier studies. Further improvements to the OE method are proposed, including a tomographic inversion technique that leverages the asymmetric sampling about the tangent point associated with GNSS-LEO links.

GNSS constellation↗

Optimized Extraction Method To Remove Humic Acid Interferences from Soil Samples Prior to Microbial Proteome Measurements

The microbial composition and their activities in soil environments play a critical role in organic matter transformation and nutrient cycling, perhaps most specifically with respect to impact on plant growth but also more broadly to global impact on carbon and nitrogen-cycling. Liquid chromatography coupled to high performance mass spectrometry provides a powerful approach to characterize soil microbiomes; however, the limited microbial biomass and the presence of abundant interferences in soil samples present major challenges to soil proteome extraction and subsequent MS measurement. To address some of the major issues, we have designed and optimized an experimental method to enhance microbial proteome extraction concomitant with minimizing the soil-borne humic substances co-extraction from soils. Among the range of interferences, humic substances are often the worst in terms of adversely impacting proteome extraction and mass spectrometry measurement. Our approach employs an in-situ detergent-based microbial lysis / TCA precipitation coupled with an additional acidification precipitation step at the peptide level which efficiently removes humic acids. By combing filtration and pH adjustment of the final peptide solution, the remaining humic acids can be differentially precipitated and removed with a membrane filter, thereby leaving much cleaner proteolytic peptide samples for MS measurement. As a result, this modified method is a reliable and straight-forward protein extraction method that efficiently removes soil-borne humic substances without inducing proteome sample loss or reducing or biasing protein identification in mass spectrometry.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient Neural Network Approaches for Conditional Optimal Transport with Applications in Bayesian Inference

In this work, we present two neural network approaches that approximate the solutions of static and dynamic conditional optimal transport (COT) problems. Both approaches enable conditional sampling and conditional density estimation, which are core tasks in Bayesian inference—particularly in the simulation-based (“likelihood-free”) setting. Our methods represent the target conditional distribution as a transformation of a tractable reference distribution. Obtaining such a transformation, chosen here to be an approximation of the COT map, is computationally challenging even in moderate dimensions. To improve scalability, our numerical algorithms use neural networks to parameterize candidate maps and further exploit the structure of the COT problem. Our static approach approximates the map as the gradient of a partially input convex neural network. It uses a novel numerical implementation to increase computational efficiency compared to state-of-the-art alternatives. Our dynamic approach approximates the conditional optimal transport via the flow map of a regularized neural ODE; compared to the static approach, it is slower to train but offers more modeling choices and can lead to faster sampling. We demonstrate both algorithms numerically, comparing them with competing state-of-the-art approaches, using benchmark datasets and simulation-based Bayesian inverse problems.

97 MATHEMATICS AND COMPUTING↗

Stochastic Approximation for Multi-period Simulation Optimization with Streaming Input Data

We consider a continuous-valued simulation optimization (SO) problem, where a simulator is built to optimize an expected performance measure of a real-world system while parameters of the simulator are estimated from streaming data collected periodically from the system. At each period, a new batch of data is combined with the cumulative data and the parameters are re-estimated with higher precision. The system requires the decision variable to be selected in all periods. Therefore, it is sensible for the decision-maker to update the decision variable at each period by solving a more precise SO problem with the updated parameter estimate to reduce the performance loss with respect to the target system. We define this decision-making process as the multi-period SO problem and introduce a multi-period stochastic approximation (SA) framework that generates a sequence of solutions. Two algorithms are proposed: Re-start SA (ReSA) reinitializes the stepsize sequence in each period, whereas Warm-start SA (WaSA) carefully tunes the stepsizes, taking both fewer and shorter gradient-descent steps in later periods as parameter estimates become increasingly more precise. We show that under suitable strong convexity and regularity conditions, ReSA and WaSA achieve the best possible convergence rate in expected sub-optimality either when an unbiased or a simultaneous perturbation gradient estimator is employed, while WaSA accrues significantly lower computational cost as the number of periods increases. In addition, we present the regularized ReSA, which obviates the need to know the strong convexity constant and achieves the same convergence rate at the expense of additional computation.

Computer Science↗

State Estimation-Based Distributed Energy Resource Optimization for Distribution Voltage Regulation in Telemetry-Sparse Environments Using a Real-Time Digital Twin

Real-time state estimation using a digital twin can overcome the lack of in-field measurements inside an electric feeder to optimize grid services provided by distributed energy resources (DERs). Optimal reactive power control of DERs can be used to mitigate distribution system voltage violations caused by increased penetrations of photovoltaic (PV) systems. In this work, a new technology called the Programmable Distribution Resource Open Management Optimization System (ProDROMOS) issued optimized DER reactive power setpoints based-on results from a particle swarm optimization (PSO) algorithm wrapped around OpenDSS time-series feeder simulations. This paper demonstrates the use of the ProDROMOS in a RT simulated environment using a power hardware-in-the-loop PV inverter and in a field demonstration, using a 678 kW PV system in Grafton (MA, USA). The primary contribution of the work is demonstrating a RT digital twin effectively provides state estimation pseudo-measurements that can be used to optimize DER operations for distribution voltage regulation.

Darbali-Zamora, Rachid↗