Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microfluidic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

On Single-Cell Enzyme Assays in Marine Microbial Ecology and Biogeochemistry

Extracellular enzyme activity is a well-established parameter for evaluating microbial biogeochemical roles in marine ecosystems. The presence and activity of extracellular enzymes in seawater provide insights into the quality and quantity of organic matter being processed by the present microorganisms. A key challenge in our understanding of these processes is to decode the extracellular enzyme repertoire and activities of natural communities at the single-cell level. Current measurements are carried out on bulk or size-fractionated samples capturing activities of mixed populations. This approach – even with size-fractionation – cannot be used to trace enzymes back to their producers, nor distinguish the active microbial members, leading to a disconnect between measured activities and the producer cells. By targeting extracellular enzymes and resolving their activities at the single-cell level, we can investigate underlying phenotypic heterogeneity among clonal or closely related organisms, characterize enzyme kinetics under varying environmental conditions, and resolve spatio-temporal distribution of individual enzyme producers within natural communities. In this perspective piece, we discuss state-of-the-art technologies in the fields of microfluidic droplets and functional screening of prokaryotic cells for measuring enzyme activity in marine seawater samples, one cell at a time. We further elaborate on how this single-cell approach can be used to address research questions that cannot be answered with current methods, as pertinent to the enzymatic degradation of organic matter by marine microorganisms.

54 ENVIRONMENTAL SCIENCES↗

Rapid, portable, multiplexed detection of bacterial pathogens directly from clinical sample matrices

Enteric and diarrheal diseases are a major cause of childhood illness and death in countries with developing economies. Each year, more than half of a million children under the age of five die from these diseases. We have developed a portable, microfluidic platform capable of simultaneous, multiplexed detection of several of the bacterial pathogens that cause these diseases. Furthermore, this platform can perform fast, sensitive immunoassays directly from relevant, complex clinical matrices such as stool without extensive sample cleanup or preparation. Using only 1 µL of sample per assay, we demonstrate simultaneous multiplexed detection of four bacterial pathogens implicated in diarrheal and enteric diseases in less than 20 min.

47 OTHER INSTRUMENTATION↗

Studying Corrosion Using Miniaturized Particle Attached Working Electrodes and the Nafion Membrane

We developed a new approach to attach particles onto a conductive layer as a working electrode (WE) in a microfluidic electrochemical cell with three electrodes. Nafion, an efficient proton transfer molecule, is used to form a thin protection layer to secure particle electrodes. Spin coating is used to develop a thin and even layer of Nafion membrane. The effects of Nafion (5 wt% 20 wt%) and spinning rates were evaluated using multiple sets of replicates. The electrochemical performance of various devices was demonstrated. Additionally, the electrochemical performance of the devices is used to select and optimize fabrication conditions. The results show that a higher spinning rate and a lower Nafion concentration (5 wt%) induce a better performance, using cerium oxide (CeO2) particles as a testing model. The WE surfaces were characterized using atomic force microscopy (AFM), scanning electron microscopy-focused ion beam (SEM-FIB), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and X-ray photoelectron spectroscopy (XPS). The comparison between the pristine and corroded WE surfaces shows that Nafion is redistributed after potential is applied. Our results verify that Nafion membrane offers a reliable means to secure particles onto electrodes. Furthermore, the electrochemical performance is reliable and reproducible. Thus, this approach provides a new way to study more complex and challenging particles, such as uranium oxide, in the future.

42 ENGINEERING↗

Cascade Dielectrophoretic Separation for Selective Enrichment of Polyhydroxybutyrate (PHB)-Producing Cyanobacterium Synechocystis sp. PCC 6803

Maintaining favorable biological productivities in photosynthetic biomanufacturing systems, especially when the risk of contamination with competing microbes is high, remains a challenge to achieve while maintaining economic feasibility. This study presents a dielectrophoresis (DEP)-based microfluidic approach for isolating a desired strain within a co-culture. The cyanobacterium Synechocystis sp. PCC 6803 (a strain capable of producing the bioplastic precursor polyhydroxybutyrate, or PHB) was enriched from mixed cultures containing the competing cyanobacterium Synechococcus elongatus PCC 7942 (which does not naturally produce PHB). A DEP cascade electrode system was established to increase purification efficiency through sequential enrichment, which leveraged inherent differences in cell morphology and dielectric properties, to achieve the selective separation of these strains under physiological conditions. A substantial increase in the relative abundance of PHB-producing cells was assessed by optical microscopy and flow cytometry characterization, confirming more than five-fold reduction of the Synechococcus fraction in the refined cell mix. The presented electrokinetic platform offers a scalable and effective approach for selectively enhancing desired microbial components within microbial biomanufacturing systems, leading towards improved product yields.

60 APPLIED LIFE SCIENCES↗

Rapid Nucleic Acid Extraction and Purification Using a Miniature Ultrasonic Technique

Miniature ultrasonic lysis for biological sample preparation is a promising technique for efficient and rapid extraction of nucleic acids and proteins from a wide variety of biological sources. Acoustic methods achieve rapid, unbiased, and efficacious disruption of cellular membranes while avoiding the use of harsh chemicals and enzymes, which interfere with detection assays. In this work, a miniature acoustic nucleic acid extraction system is presented. Using a miniature bulk acoustic wave (BAW) transducer array based on 36° Y-cut lithium niobate, acoustic waves were coupled into disposable laminate-based microfluidic cartridges. To verify the lysing effectiveness, the amount of liberated ATP and the cell viability were measured and compared to untreated samples. The relationship between input power, energy dose, flow-rate, and lysing efficiency were determined. DNA was purified on-chip using three approaches implemented in the cartridges: a silica-based sol-gel silica-bead filled microchannel, nucleic acid binding magnetic beads, and Nafion-coated electrodes. Using E. coli, the lysing dose defined as ATP released per joule was 2.2× greater, releasing 6.1× more ATP for the miniature BAW array compared to a bench-top acoustic lysis system. An electric field-based nucleic acid purification approach using Nafion films yielded an extraction efficiency of 69.2% in 10 min for 50 µL samples.

59 BASIC BIOLOGICAL SCIENCES↗

Time-lapse Fluorescence Imaging of Arabidopsis Root Growth with Rapid Manipulation of The Root Environment Using The RootChip

The root functions as the physical anchor of the plant and is the organ responsible for uptake of water and mineral nutrients such as nitrogen, phosphorus, sulfate and trace elements that plants acquire from the soil. If we want to develop sustainable approaches to producing high crop yield, we need to better understand how the root develops, takes up a wide spectrum of nutrients, and interacts with symbiotic and pathogenic organisms. To accomplish these goals, we need to be able to explore roots in microscopic detail over time periods ranging from minutes to days. We developed the RootChip, a polydimethylsiloxane (PDMS)- based microfluidic device, which allows us to grow and image roots from Arabidopsis seedlings while avoiding any physical stress to roots during preparation for imaging1 (Figure 1). The device contains a bifurcated channel structure featuring micromechanical valves to guide the fluid flow from solution inlets to each of the eight observation chambers2 . This perfusion system allows the root microenvironment to be controlled and modified with precision and speed. The volume of the chambers is approximately 400 nl, thus requiring only minimal amounts of test solution. Here we provide a detailed protocol for studying root biology on the RootChip using imaging-based approaches with real time resolution. Roots can be analyzed over several days using time lapse microscopy. Roots can be perfused with nutrient solutions or inhibitors, and up to eight seedlings can be analyzed in parallel. This system has the potential for a wide range of applications, including analysis of root growth in the presence or absence of chemicals, fluorescence-based analysis of gene expression, and the analysis of biosensors, e.g. FRET nanosensors3.

59 BASIC BIOLOGICAL SCIENCES↗

MRI Zooms in on Microscopic Flow

MRI images of water flow through a constricted microfluidic channel with the XZ axis on the left and the YZ axis on the right. Note that fast moving components directly aligned with the constricted region emerge at the detector first, followed by components that are not aligned with the constriction.

47 OTHER INSTRUMENTATION↗

Advances in Online Monitoring for Measurement within Nuclear Fuel Reprocessing Streams

Abstract – Significant effort has been focused on the back end of the nuclear fuel cycle including treatment and reuse of irradiated fuel. Solvent extraction reprocessing methods that have been developed often contain various steps, with each one tailored to the separation of specific radionuclides, which are highly dependent upon solution properties. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. Our group has been investigating the use of optical spectroscopy for the on-line monitoring of actinides, lanthanides, and acid strength within fuel reprocessing streams. This paper describes the application of the electronic and vibrational spectroscopic techniques for radiochemical process monitoring. In this context, our team experimentally assessed the potential of Raman and UV-vis spectroscopic techniques for online real-time monitoring of the U(VI)/nitrate ion/nitric acid and Pu(VI/IV)/Np(VI/V/IV)/Nd(III) in solutions relevant to used nuclear fuel reprocessing. These techniques demonstrated robust performance in the repetitive batch measurements of each analyte in a wide concentration range using simulant and commercial dissolved used fuel solutions. Currently this has been demonstrated on the macroscopic scale, using sample probes requiring large solution volumes. In an effort to minimize waste and reduce dose to personnel, we have modified this technique to allow measurement at the microfluidic scale using a Raman microprobe. Under the current sampling environment, Raman samples typically require upwards of 10 mL and larger. Using the new sampling system, we can sample volumes at 10 µL or less, which is a scale reduction of over 1,000 fold in sample size. This will significantly reduce the requirements for handling hazardous materials, and greatly reduce the costs associated with worker protection from exposure to radioactive and hazardous materials, and costs due to waste disposal.

process monitoring, U, nitric acid, microfluidic, ↗

Impact of viscous fingering and permeability heterogeneity on fluid mixing in porous media

Fluid mixing plays a fundamental role in many natural and engineered processes, including groundwater flows in porous media, enhanced oil recovery, and microfluidic lab-on-a-chip systems. Recent developments have explored the effect of viscosity contrast on mixing, suggesting that the unstable displacement of fluids with different viscosities, or viscous fingering, provides a powerful mechanism to increase fluid-fluid interfacial area and enhance mixing. However, existing studies have not incorporated the effect of medium heterogeneity on the mixing rate. Here, we characterize the evolution of mixing between two fluids of different viscosity in heterogeneous porous media. We focus on a practical scenario of divergent-convergent flow in a quarter five spot geometry prototypical of well-driven groundwater flows. We study by means of numerical simulations the impact of permeability heterogeneity and viscosity contrast on the breakthrough curves and mixing efficiency, and we rationalize the nontrivial mixing behavior that emerges from the competition between the creation of fluid-fluid interfacial area and channeling.

58 GEOSCIENCES↗

On the dynamics and kinematics of two-fluid-phase flow in porous media

A model formulated in terms of both conservation and kinematic equations for phases and interfaces in two-fluid-phase flow in a porous medium system is summarized. Macroscale kinematic equations are derived as extensions of averaging theorems and do not rely on conservation principles. Models based on both conservation and kinematic equations can describe multiphase flow with varying fidelity.When only phase-based equations are considered, a model similar in form to the traditional model for two-fluid-phase flow results. When interface conservation and kinematic equations are also included, a novel formulation results that naturally includes evolution equations that express dynamic changes in fluid saturations, pressures, the capillary pressure, and the fluid-fluid interfacial area density in a two-fluid-system. This dynamic equation set is unique to this work, and the importance of the modeled physics is shown through both microfluidic experiments and high-resolution lattice Boltzmann simulations. The validation work shows that the relaxation of interface distribution and shape toward an equilibrium state is a slow process relativeto the time scale typically allowed for a system to approach an apparent equilibrium state based upon observations of fluid saturations and external pressure measurements. Consequently, most pressure-saturation data intended to denote an equilibrium state are likely a sampling from a dynamic system under-going changes of interfacial curvatures that are not typically monitored. The results confirm the importance of kinematic analysis in combination with conservation equations for faithful modeling of system physics.

54 ENVIRONMENTAL SCIENCES↗

An adaptive lattice Boltzmann scheme for modeling two-fluid-phase flow in porous medium systems

In this paper, we formulate a multiple-relaxation-time (MRT) lattice-Boltzmann method (LBM) to simulate two-fluid-phase flow in porous medium systems. The MRT LBM is applied to simulate the displacement of a wetting fluid by a nonwetting fluid in a system corresponding to a microfluidic cell. Analysis of the simulation shows widely varying time scales for the dynamics of fluid pressures, fluid saturations, and interfacial curvatures that are typical characteristics of such systems. Displacement phenomena include Haines jumps, which are relatively short duration isolated events of rapid fluid displacement driven by capillary instability. An adaptive algorithm is advanced using a level-set method to locate interfaces and estimate their rate of advancement. Because the displacement dynamics are confined to the interfacial regions for a majority of the relaxation time, the computational effort is focused on these regions. The proposed algorithm is shown to reduce computational effort by an order of magnitude, while yielding essentially identical solutions to a conventional fully coupled approach. Finally, the challenges posed by Haines jumps are also resolved by the adaptive algorithm. Possible extensions to the advanced method are discussed.

42 ENGINEERING↗

Transparent, Anisotropic Biofilm with Aligned Bacterial Cellulose Nanofibers

Abstract Cellulose nanofibrils are attractive as building blocks for advanced photonic, optoelectronic, microfluidic, and bio‐based devices ranging from transistors and solar cells to fluidic and biocompatible injectable devices. For the first time, an ultrastrong and ultratough cellulose film, which is composed of densely packed bacterial cellulose (BC) nanofibrils with hierarchical fibril alignments, is successfully demonstrated. The molecular level alignment stems from the intrinsic parallel orientation of crystalline cellulose molecules produced by Acetobacter xylinum. These aligned long‐chain cellulose molecules form subfibrils with a diameter of 2–4 nm, which are further aligned to form nanofibril bundles. The BC film yields a record‐high tensile strength (≈1.0 GPa) and toughness (≈25 MJ m −3 ). Being ultrastrong and ultratough, yet the BC film is also highly flexible and can be folded into desirable shapes. The BC film exhibits a controllable manner of alignment and is highly transparent with modulated optical properties, paving the way to enabling new functionalities in mechanical, electrical, fluidic, photonics, and biocompatible applications.

Wang, Sha↗

Porous Enzymatic Membrane for Nanotextured Glucose Sweat Sensors with High Stability toward Reliable Noninvasive Health Monitoring

Development of reliable glucose sensors for noninvasive monitoring without interruption or limiting users' mobility is highly desirable, especially for diabetes diagnostics, which requires routine/long-term monitoring. However, their applications are largely limited by the relatively poor stability. In this paper, a porous membrane is synthesized for effective enzyme immobilization and it is robustly anchored to the modified nanotextured electrode solid contacts, so as to realize glucose sensors with significantly enhanced sensing stability and mechanical robustness. To the best of our knowledge, this is the first report of utilizing such nanoporous membranes for electrochemical sensor applications, which eliminates enzyme escape and provides a sufficient surface area for molecular/ion diffusion and interactions, thus ensuring the sustainable catalytic activities of the sensors and generating reliable measureable signals during noninvasive monitoring. The as-assembled nanostructured glucose sensors demonstrate reliable long-term stable monitoring with a minimal response drift for up to 20 h, which delivers a remarkable enhancement. Moreover, they can be integrated into a microfluidic sensing patch for noninvasive sweat glucose monitoring. The as-synthesized nanostructured glucose sensors with remarkable stability can inspire developments of various enzymatic biosensors for reliable noninvasive composition analysis and their ultimate applications in predictive clinical diagnostics, personalized health-care monitoring, and chronic diseases management.

36 MATERIALS SCIENCE↗

Fluidic Flow Assisted Deterministic Folding of Van der Waals Materials

Origami offers a distinct approach for designing and engineering new material structures and properties. The folding and stacking of atomically thin van der Waals (vdW) materials, for example, can lead to intriguing new physical properties including bandgap tuning, Van Hove singularity, and superconductivity. On the other hand, achieving well-controlled folding of vdW materials with high spatial precision has been extremely challenging and difficult to scale toward large areas. In this paper, a deterministic technique is reported to fold vdW materials at a defined position and direction using microfluidic forces. Electron beam lithography (EBL) is utilized to define the folding area, which allows precise control of the folding geometry, direction, and position beyond 100 nm resolution. Using this technique, single-atomic-layer vdW materials or their heterostructures can be folded without the need for any external supporting layers in the final folded structure. In addition, arrays of patterns can be folded across a large area using this technique and electronic devices that can reconfigure device functionalities through folding are also demonstrated. Such scalable formation of folded vdW material structures with high precision can lead to the creation of new atomic-scale materials and superlattices as well as opening the door to realizing foldable and reconfigurable electronics.

2D materials↗

Soft materials with recoverable shape factors from extreme distortion states

We present elastomeric polysiloxane nanocomposites with elongations of >5000% (more than 3× greater than any previously reported material) with excellent shape recovery. Highly deformable materials are desirable for the fabrication of stretchable implants and microfluidic devices. No crosslinking or domain formation is observed by a variety of analytical techniques, suggesting that their elastomeric behavior is caused by polymer chain entanglements.

36 MATERIALS SCIENCE↗

Liquid Letters

Abstract Using the interfacial jamming of cellulose nanocrystal (CNC) surfactants, a new concept, termed all‐liquid molding, is introduced to produce all‐liquid objects that retain the shape and details of the mold with high fidelity, yet remain all liquid and are responsive to external stimuli. This simple process, where the viscosity of the CNC dispersion can range from that of water to a crosslinked gel, opens tremendous opportunities for encapsulation, delivery systems, and unique microfluidic devices. The process described is generally applicable to any functionalized nanoparticles dispersed in one liquid and polymer ligands having complementary functionality dissolved in a second immiscible liquid. Such sculpted liquids retain all the characteristics of the liquids but retain shape indefinitely, very much like a solid, and provide a new platform for next‐generation soft materials.

Shi, Shaowei↗

A Highly Porous Copper Electrocatalyst for Carbon Dioxide Reduction

Electrochemical reduction of carbon dioxide (CO 2 ) is an appealing approach toward tackling climate change associated with atmospheric CO 2 emissions. This approach uses CO 2 as the carbon feedstock to produce value-added chemicals, resulting in a carbon-neutral (or even carbon-negative) process for chemical production. Many efforts have been devoted to the development of CO 2 electrolysis devices that can be operated at industrially relevant rates; however, limited progress has been made, especially for valuable C 2+ products. Herein, we synthesized a nanoporous copper CO 2 reduction catalyst and integrated it into a microfluidic CO 2 flow cell electrolyzer. The CO 2 electrolyzer exhibited a current density of 653 mA/cm -2 with a C 2+ product selectivity of ~62% at an applied potential of -0.67 V (vs. reversible hydrogen electrode). Here, the highly porous electrode structure facilitated rapid gas transport across the electrode-electrolyte interface at high current densities. Further investigations on electrolyte effects revealed that the surface pH value was substantially different from the pH of bulk electrolyte, especially for non-buffering near-neutral electrolytes when operating at high currents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗