At least 919 records · Page 51

Data Acquisition with GPUs: The DAQ for the Muon $g$-$2$ Experiment at Fermilab

Graphical Processing Units (GPUs) have recently become a valuable computing tool for the acquisition of data at high rates and for a relatively low cost. The devices work by parallelizing the code into thousands of threads, each executing a simple process, such as identifying pulses from a waveform digitizer. The CUDA programming library can be used to effectively write code to parallelize such tasks on Nvidia GPUs, providing a significant upgrade in performance over CPU based acquisition systems. The muon $g$-$2$ experiment at Fermilab is heavily relying on GPUs to process its data. The data acquisition system for this experiment must have the ability to create deadtime-free records from 700 $\mu$s muon spills at a raw data rate 18 GB per second. Data will be collected using 1296 channels of $\mu$TCA-based 800 MSPS, 12 bit waveform digitizers and processed in a layered array of networked commodity processors with 24 GPUs working in parallel to perform a fast recording of the muon decays during the spill. The described data acquisition system is currently being constructed, and will be fully operational before the start of the experiment in 2017.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hunting Muon Neutrinos in MicroBooNE With Deep Learning Techniques

The MicroBooNE experiment is a large Liquid Argon TPC located on the Booster Neutrino Beam at Fermi National Laboratory. The primary goal is to investigate the source of the excess of low energy electron neutrino events observed by the MiniBooNE experiment. The main background to the oscillation signal arises from intrinsic electron neutrinos coming from decay of pions and muons in the beam rather than oscillation. To constrain the systematic uncertainty on this background, MicroBooNE will perform a combined fit to both the muon and electron neutrino spectra. This method provides constraints on flux, cross section, and detector uncertainties. This poster will discuss the identification and selection of muon neutrino events using a novel hybrid approach of Deep Learning and traditional reconstruction algorithms that can be used for this constraint.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of Monoenergetic Muon Neutrino Charged Current Interactions

aWe report the first measurement of monoenergetic muon neutrino charged current interactions. The NuMI beam absorber provides an intense source of 236 MeV muon neutrino events originating from kaon decay at rest ($K^+\rightarrow \mu^+\nu_\mu$) that are observed by the MiniBooNE detector. The kaon-decay-at-rest (KDAR) neutrino represents a standard candle for studying neutrino-nucleus interactions, cross sections, and energy reconstruction in the hundreds of MeV region and can be used for a number of precision measurements. The KDAR signal at MiniBooNE, observed with $3.9\sigma$ significance, is distinguished from $\nu_\mu$ and $\bar{\nu}_\mu$ backgrounds using arrival time and reconstructed muon energy. This result is the first known-energy, weak-interaction-only probe of the nucleus to yield a measurement of neutrino-nucleus energy transfer ($\omega=E_\nu-E_\mu$).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experiences from the Commissioning and First Physics Run of the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment (E989) at Fermilab is seeking to measure the anomalous magnetic moment of muon ($a_{\mu}$) with a precision of 140 parts-per-billion (ppb) and aiming to resolve the discrepancy between the E821 measurement and the Standard Model calculation of $a_{\mu}$. In E989, the muon beam is stored in a ring magnet. The anomalous spin precession frequency $\omega_{a}$ is measured by counting decay positrons in 24 calorimeters, and the magnetic field is measured by nuclear magnetic resonance (NMR) probes. Improvements in this experiment with respect to its predecessor and the progress achieved in the commissioning run and the first physics run, Run-1, are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and Analysis of Beam Phase-Space Distributions for the Fermilab Muon Campus Accelerator Complex

The Muon g-2 experiment at Fermilab is tasked with measuring the muon’s anomalous magnetic moment with high precision. Since the experiment requires large amounts of muons, it is imperative to systematically study the behavior of the beam along the transport line. Unfortunately, the available diagnostics only provide beam information in X-Y space. For a complete evaluation, information of the phase-space is required. This paper demonstrates a technique to measure the beam phase-direction distribution by using a set of beam profiles. First, we establish the theoretical framework that describes the principle of the technique. Next, we apply the technique at four different locations along the accelerator delivery line. Finally, we compare our findings to predictions from tracking simulations.

43 PARTICLE ACCELERATORS↗

Preliminary Report on the Study of Beam-Induced Background Effects at a Muon Collider

Physics at a multi-TeV muon collider needs a change of perspective for the detector design due to the large amount of background induced by muon beam decays. Preliminary studies, based on simulated data, on the composition and the characteristics of the particles originated from the muon decays and reaching the detectors are presented here. The reconstruction performance of the physics processes $H\to b\bar b$ and $Z\to b\bar b$ has been investigated for the time being without the effect of the machine induced background. A preliminary study of the environment hazard due to the radiation induced by neutrino interactions with the matter is presented using the FLUKA simulation program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The E989 Muon g-2 experiment at Fermilab aims to measure the anomalous magnetic moment, a$_\mu$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $\omega_a$, and the average magnetic field in terms of the equivalent, free proton Larmor frequency, $\omega_p$. The measurement of $\omega_p$ with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration in terms of $\omega_p$. A crucial element for the multi-step measurement of $\omega_p$ is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Fermilab Muon g - 2 Experiment

The muon anomalous magnetic moment, aµ = ( g - 2 )/2, is a low-energy observable which can be both measured and computed with very high precision, making it an excellent test of the Standard Model (SM) and a sensitive probe of new physics. Recent efforts improved the precision of both the theoretical prediction and the experimental measurement. On the theory side, the Muon g - 2 Theory Initiative, an international team of more than 130 physicists, reached in 2020 a consensus on the SM prediction for aµ. On the experimental side, the E989 Muon g - 2 Collaboration at Fermilab (FNAL) published in April 2021 a new measurement of aµ from the Run-1 dataset (2018) with 0.46 ppm precision, corroborating the previous Brookhaven National Laboratory (BNL) measurement and increasing the discrepancy with the SM value to 4.2 standard deviations. In this paper, I will discuss the experimental setup and report on the current status of the experiment.

Girotti, Paolo↗

Solving Critical Problems of the Muon Collider Higgs Factory: Optics, Magnets and their Protection, Detector Backgrounds

A low-energy medium-luminosity Muon Collider (MC) is being studied as a possible Higgs Factory (HF). Electrons from muon decays will deposit more than 300 kW in superconducting magnets of the HF collider ring. This imposes significant challenges to superconducting (SC) magnets used in the MC storage ring (SR) and interaction regions (IR). Magnet designs are proposed which provide high operating gradient and magnetic field in a large aperture to accommodate the large size of muon beams (due to low beta*), as well as a cooling system to intercept the large heat deposition from the showers induced by decay electrons. The distribution of heat deposition in the MC SR lattice elements requires large-aperture magnets in order to accommodate thick high-Z absorbers to protect the SC coils. Based on the developed MARS15 model and intensive simulations, a sophisticated radiation protection system was designed for the collider SR and IR to bring the peak power density in the superconducting coils below the quench limit and reduce the dynamic heat deposition in the cold mass by a factor of 100. The system consists of tight tungsten masks in the magnet interconnect regions and elliptical tungsten liners in the magnet aperture optimized individually for each magnet. These also reduce the background particle fluxes in the collider detector.

43 PARTICLE ACCELERATORS↗

Muon Collider Physics Summary

The perspective of designing muon colliders with high energy and luminosity, which is being investigated by the International Muon Collider Collaboration, has triggered a growing interest in their physics reach. We present a concise summary of the muon colliders potential to explore new physics, leveraging on the unique possibility of combining high available energy with very precise measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling the Effect of the Interplanetary Magnetic Field on Cosmic Ray Muon Shadows

Cosmic ray (CR) muon shadows were located using muon data from the MINOS Far Detector in Northern Minnesota. The shadows were located independently across 3 time periods; near solar minimum, solar maximum, and over the entire 13 year span of the data. A muon distribution for each shadow was then sampled to simulate CR motions near the Sun using the Parker Spiral model of the Sun’s IMF and a dipole model of the Earth’s GMF. The resulting particle distributions were then compared to their position with respect to the Sun. An analytical relationship between the primary CR cutoff energy E0 and the associated shadow deflections was observed. The minimum cutoff energy of the primary CR energy spectrum consistent with the Parker Spiral model was determined to be $E_0 = 22.8 \pm 1.2$~TeV. This value is 2-3 times higher than the experimentally determined value. Complexities that can be added to the Parker Spiral Model and affect the overall shift of the the Sun’s cosmic ray shadow are discuss ed to explain discrepancies. Results show that the Parker Spiral model is most consistent with the the solar minimum shadow and least consistent with the solar maximum shadow, as expected.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Staged Muon-based Facility to Enable Intensity and Energy Frontier Science in the US

Muon-based facilities offer a unique potential to provide capabilities at both the Intensity Frontier with Neutrino Factories and the Energy Frontier with Muon Colliders ranging from the Higgs energy to the multi-TeV energy range. They rely on novel technology with challenging parameters, for which the feasibility is currently being assessed by the U.S. Muon Accelerator Program (MAP) [1]. A realistic scenario for a complementary series of staged facilities with increasing complexity and significant physics potential at each stage has been developed. It takes advantage of and leverages the capabilities already planned at Fermilab, especially Project X and LBNE. Each stage is defined in such a way as to provide an R&D platform to validate the technologies required for subsequent stages. The rationale and sequence of a realistic staging process are presented.

Delahaye, Jean-Pierre↗

MATCHED OPTICS OF MUON RLA AND NON-SCALING FFAG ARCS

Recirculating Linear Accelerators (RLA) are an efficient way of accelerating short-lived muons to multi-GeV energies required for Neutrino Factories and TeV energies required for Muon Colliders. To reduce the number of required return arcs, we employ a Non-Scaling Fixed-Field Alternating-Gradient (NS-FFAG) arc lattice design. We present a complete linear optics design of a muon RLA with two-pass linear NS-FFAG droplet return arcs. The arcs are composed of symmetric cells with each cell designed using combined function magnets with dipole and quadrupole magnetic field components so that the cell is achromatic and has zero initial and final periodic orbit offsets for both passes? energies. Matching to the linac is accomplished by adjusting linac quadrupole strengths so that the linac optics on each pass is matched to the arc optics. We adjust the difference of the path lengths and therefore of the times of flight of the two momenta in each arc to ensure proper synchronization with the linac. We investigate the dynamic aperture and momentum acceptance of the arcs.

43 PARTICLE ACCELERATORS↗

First Measurement of Inclusive Muon Neutrino Charged Current Triple Differential Cross Section on Argon

The field of accelerator neutrino experiments is entering an era of precision oscillation measurements where the remaining unknown neutrino measurements will be determined. The upcoming DUNE and Hyper-K experiments aim to determine the neutrino mass hierarchy and degree of Charge-Parity (CP) violation in the neutrino sector, providing potential insight on the matter-antimatter imbalance observed in the universe. However, these experiments require highly accurate measurements, and neutrino cross section modeling uncertainties may limit their capabilities. Cross section measurements at current- generation experiments can aid the development of neutrino interaction models to reduce these uncertainties. This is especially true for measurements of neutrino energy, as it drives neutrino oscillations and is of key importance to oscillation experiments. The MicroBooNE experiment uses a Liquid Argon Time Projection Chamber (LArTPC) to produce neutrino-argon cross sections as one of its physics goals. The MicroBooNE detector’s fully active volume, precision reconstruction, and calorimetry information are leveraged in the Wire-Cell analysis to produce a muon neutrino selection that is 92% pure while maintaining 68% efficiency. A reconstruction chain featuring a fully 3D charge reconstruction and a graph-based particle trajectory fit are used to produce accurate measurements of lepton kinematics as well as visible hadronic energy produced in a neutrino interaction. This thesis presents the first neutrino-argon triple-differential cross section measurement, targeting inclusive charged-current final states. Wiener SVD unfolding is used to produce a measurement over neutrino energy, muon momentum, and muon scattering angle. A series of constrained goodness of fit tests are used to demonstrate the validity of MicroBooNE’s model in describing the distribution of reconstructed kinematics seen in data to ensure the accuracy of unfolding. The validated unfolding to neutrino energy represents a step forward in the field of neutrino cross sections, and demonstrates the capabilities of the LArTPC detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the double-differential cross section of muon-neutrino charged-current interactions with low hadronic energy in the NOvA Near Detector

The NOvA collaboration reports cross-section measurements for $\nu_{\mu}$ charged-current interactions with low hadronic energy (maximum kinetic energy of 250 MeV for protons and 175 MeV for pions) in the NOvA Near Detector. The results are presented as a double-differential cross section as a function of the direct observables of the final-state muon kinematics. Results are also presented as a single-differential cross section as a function of the derived square of the four-momentum transfer, $Q^{2}$, and as a function of the derived neutrino energy. The data correspond to an accumulated 8.09$\times10^{20}$ protons-on-target (POT) in the neutrino mode of the NuMI beam, with a narrow band of neutrino energies peaked at 1.8 GeV. The analysis provides a sample of neutrino-nucleus interactions with an enhanced fraction of quasi-elastic and two-particle-two-hole (2p2h) interactions. This enhancement allows quantitative comparisons with various nuclear models. We find strong disagreement between data and theory-based models in various regions of the muon kinematic phase space, especially in the forward muon direction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Anomalous Spin Precession Frequency Analysis in the Muon $g-2$ Experiment at Fermilab

The Muon $g-2$ experiment at Fermilab aims to measure the muon anomalous magnetic moment with an unprecedented precision of 140 parts per billion (ppb). Data collection concluded in June 2023, and analysis of the largest dataset (2021-2023) is underway. Previous publications based on data from 2018-2020 established the experimental foundation. This document provides an overview of the measurement of the muon anomalous spin precession frequency ($\omega_a$) and the associated systematic corrections. The precision of these results directly tests the Standard Model's completeness, making the experiment a cornerstone in the field of particle physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the Muon Neutrino Magnetic Moment in the NOvA Near Detector

Measuring an enhanced neutrino magnetic moment would be a clear indication of physics beyond the Standard Model, shedding light on the correct beyond Standard Model theory or the potential Majorana nature of neutrinos. It would manifest in the NOvA near detector as an excess of neutrino-on-electron elastic scattering interactions at low electron recoil energies. Leveraging an intense and highly pure muon neutrino beam, along with a finely segmented liquid scintillator detector technology specifically designed for electromagnetic shower separation, enables NOvA to achieve a potentially world-leading sensitivity in probing the effective muon neutrino magnetic moment. This analysis, based on neutrino data collected between 2014 and 2021, corresponding to an exposure of $13.8\times10^{20}$ protons-on-target, yields a result consistent with the Standard Model-only hypothesis with a p-value of 0.31. An upper limit on the effective muon neutrino magnetic moment is set at $\mu_{\nu_\mu}<19.1\times 10^{-10}\mu_B$ at $90\%$ confidence level. Despite facing statistical limitations stemming from low cross section of the signal process, systematic uncertainties have a significant impact on this result. To address these challenges, the NOvA Test Beam experiment focuses on mitigating some of the largest systematic uncertainties within NOvA by investigating particle interactions and energy deposition in a small-scale replica NOvA detector. This thesis describes the calibration of the NOvA Test Beam detector, which is a crucial step in analysing the Test Beam data before they can be utilised to reduce NOvA systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗