Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear data testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

New Los Alamos space instrument goes for a spin

Scientists and engineers at Los Alamos National Laboratory are using a unique centrifuge facility to evaluate a flight-ready telemetry system for evaluating a nuclear weapons test missile launch. "The telemetry unit was designed and manufactured by Los Alamos' Intelligence and Space Research Division," said Telemetry Program Manager Myles Fitzgerald. "Telemetry is a data stream of information on temperature, acceleration, vibration, strain, all the conditions a system encounters during a test flight." Because a test missile flight ultimately ends with the test system completely destroyed, telemetry data from the flight must be collected by receiving stations along the flight path. "The purpose of the centrifuge test is to subject the electronics to a high gravitational load (G-load) that's representative of what the system will experience when re-entering the Earth's atmosphere," said weapons test engineer Alex Cusick.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Pilot-Scale TRUEX Flowsheet Testing for Separation of Actinides and Lanthanides from Used Nuclear Fuel

Advanced aqueous separation processes are being developed for the recycling of used nuclear fuel as part of the U.S. Department of Energy Nuclear Energy Advanced Fuel Cycle Initiative. The Transuranic Extraction (TRUEX) Process is being developed as part of these advanced separations processes for the separation of actinides and lanthanides from the used nuclear fuel. Testing of a TRUEX flowsheet has been performed using a thirty stage, 5-cm centrifugal contactor pilot plant. This testing was performed using a non-radioactive feed surrogate and data were collected and analyzed to evaluate removal efficiencies of the lanthanides, mass transfer efficiency of the lanthanides in the extraction and strip sections of the flowsheet, and the temperature profile of the process solutions throughout the centrifugal contactor pilot plant. Results indicate >99.9% separation for all lanthanides and mass transfer efficiencies typically ranging from 85% to 100%. Solution temperatures for each contactor stage, as well as general process performance, are also described.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Roadmap for the Application of Ion Beam Technologies to Challenges for the Advancement and Implementation of Nuclear Energy Technologies

The use of ion beams in interrogating materials performance for nuclear energy applications is advancing at a rapid rate. Ion irradiations have been proven to produce radiation effects data that are of direct relevance for understanding neutron-induced displacement damage. This development reflects significant and continued investment in infrastructure by the U.S. Department of Energy (DOE) as well as support of science and engineering research at universities and national laboratories. Application of ion beam irradiation methods to enhance the deployment of materials in reactors is in the spirit of the Gateway for Accelerated Innovation in Nuclear (GAIN) initiative sponsored by DOE to accelerate the deployment of innovation in the U.S. nuclear industry. Ion beam irradiation shows considerable promise for assisting in down selecting candidate materials for use in both current and advanced nuclear energy systems. Ion beams allow rapid achievement of materials damage levels not accessible by neutron irradiation in test reactors due to cost and time constraints. Ion beam studies provide data on the effects of irradiation under very specific conditions of temperature, radiation dose, and radiation dose rate that are difficult or impossible to achieve via reactor irradiation experiments. This data can be used to develop and validate detailed predictive radiation effects models for use in reactor materials research and development. Despite the current high state of the art and the maturity of quality assurance, there are still challenges to the deployment of ion beam data in support of reactor materials qualification. For the most part, these challenges arise from the lack of a detailed mechanistic understanding of potential difference between ion induced and neutron induced materials damage, which is exacerbated by difficulties in obtaining bulk physical and mechanical properties data from the micron-scale heavy ion irradiation depths. In particular, improved understanding of dose rate effects, as a function of temperature, are needed. This document offers a roadmap for the development and enhancement of current U.S. ion beam irradiation technologies within university and national laboratory settings, and especially for the deployment of new highly controlled in situ interrogation of materials during irradiation to provide dynamic and mechanistic data for model development. The status and capabilities of relevant U.S. ion beam facilities are summarized and recommended “best practices” for performing ion irradiations are described. The potential role of ion beam irradiations to assist the development and deployment of reactor materials is outlined. Key principles include developing methods for rapid and cost-effective materials selection and development, characterizing fundamental material response under irradiation, and developing a robust mechanistic understanding of microstructure evolution under irradiation (including development and validation of reliable predictive models for microstructure evolution).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty quantification of fireball features extracted from nuclear test films using computer vision

Films from the US’s historic nuclear testing era comprise the only extensive collection of imagery depicting high-yield detonations. These films offer unique insights into the characteristics of flows occurring on scales that are difficult to replicate experimentally, and they are a valuable source of data for the validation of models used to describe nuclear detonations. In recent work, we implemented modern computer vision and machine learning techniques to extract features of the fireball following nuclear detonation. With a training dataset of fireball films, we fine-tuned a You Only Look Once 11 (YOLO11) model to detect and track the fireball. Applied to a video, the outer bounding box produced in each frame by YOLO11 is used as an input prompt to Meta’s Segment Anything Model 2 (SAM2), which is shown to accurately predict the boundary of the fireball over time with high resolution. These state-of-the-art computer vision foundation models exhibit impressive visual accuracy in their results but lack an output of values that robustly quantify uncertainty in scientific applications. In this paper, we develop procedures for uncertainty quantification of extracted fireball features. We outline the application of a parallel attention mechanism to calculate uncertainty ranges that complement and better pose model validation data. This higher quality fireball validation data may serve to improve prognostic models describing nuclear detonations in support of nuclear forensic and emergency response activities.

Khristy, Joel [ORNL] (ORCID:0000000209963060)↗

SU-E-T-673: Recent Developments and Comprehensive Validations of a GPU-Based Proton Monte Carlo Simulation Package, GPMC

Purpose: A GPU-based Monte Carlo (MC) simulation package gPMC has been previously developed and high computational efficiency was achieved. This abstract reports our recent improvements on this package in terms of accuracy, functionality, and code portability. Methods: In the latest version of gPMC, nuclear interaction cross section database was updated to include data from TOPAS/Geant4. Inelastic interaction model, particularly the proton scattering angle distribution, was updated to improve overall simulation accuracy. Calculation of dose averaged LET (LETd) was implemented. gPMC was ported onto an OpenCL environment to enable portability across different computing devices (GPUs from different vendors and CPUs). We also performed comprehensive tests of the code accuracy. Dose from electro-magnetic (EM) interaction channel, primary and secondary proton doses and fluences were scored and compared with those computed by TOPAS. Results: In a homogeneous water phantom with 100 and 200 MeV beams, mean dose differences in EM channel computed by gPMC and by TOPAS were 0.28% and 0.65% of the corresponding maximum dose, respectively. With the Geant4 nuclear interaction cross section data, mean difference of primary proton dose was 0.84% for the 200 MeV case and 0.78% for the 100 MeV case. After updating inelastic interaction model, maximum difference of secondary proton fluence and dose were 0.08% and 0.5% for the 200 MeV beam, and 0.04% and 0.2% for the 100 MeV beam. In a test case with a 150MeV proton beam, the mean difference between LETd computed by gPMC and TOPAS was 0.96% within the proton range. With the OpenCL implementation, gPMC is executable on AMD and Nvidia GPUs, as well as on Intel CPU in single or multiple threads. Results on different platforms agreed within statistical uncertainty. Conclusion: Several improvements have been implemented in the latest version of gPMC, which enhanced its accuracy, functionality, and code portability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NucD-25 Nuclear Diagnostics Development: NIS capability, Maximizing gamma ray dynamic range, (n,γ) measurements for carbon ρR [Slides]

The LANL Neutron Imaging team is preparing for NIS upgrades and novel capabilities with the advent of consistently higher yields at NIF. Novel scintillators, solid-state detectors, multiplexed imaging detectors, upgraded data acquisition systems, and camera testing are all areas in need of experimental study to further develop imaging capabilities and dynamic range at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-sensitive Magnetic Microscopy with an Atomic Magnetometer

The PowerPoint presentation focused on research goals, specific information about the atomic magnetometer, response and resolution factors of the SERF magnetometer, FC+AM systems, tests of field transfer and resolution on FC, gradient cancellation, testing of AM performance, ideas for a multi-channel AM, including preliminary sensitivity testing, and a description of a 6 channel DAQ system. A few ideas for future work ended the presentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integral and Separate Effects Test Facilities To Support Water Cooled Small Modular Reactors: A Review

This study reviews previous experimental facilities and test programs relevant to water-cooled reactor system design and analysis to meet regulatory compliances. This study aims to find the best solution for designing the required experiments, obtaining necessary test data, and verifying the developed computer code/models to support the new reactor design and development while minimizing cost and time while leveraging experiences from previous facilities to minimize. Nuclear reactor licensing requires supportive design, analysis, and experimental results to ensure the safety of the full-scale prototype reactor in regular operation, as well as during postulated accident scenarios. These reactor design analyses are generally performed using system codes and other associated simulation tools that require assessment, verification and validation using an appropriate experimental dataset. Experimental facilities used for reactor system safety analysis and system code assessments are categorized into integral effects test (IET) and separate effects test (SET) facilities. Further, these IET and SET experiments and studies use geometrically scaled systems to reproduce the prototype system behavior at a reasonable cost, albeit with some scaling-related distortions. The design challenge of these model facilities is to identify and minimize scaling distortions while reproducing the most important operational phenomena in steady-state operation and in postulated accident scenarios. Lessons learned from previous experimental facilities, models, and correlations can support the development of new multipurpose, scaled, hybrid, integrated, and modular experimental facilities for advanced light water-cooled small modular reactors (SMRs). Successful operation of these facilities can significantly reduce upfront reactor development and demonstration costs and time to deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Requalification of the ATR Core

The Advanced Test Reactor (ATR) creates a unique, high neutron flux materials testing environment that subsequently causes neutron embrittlement damage to its beryllium reflector. The reflector is eventually required to be replaced during a reactor Outage. Concurrently, a piece-for-piece core replacement is conducted to maintain reactor functionality called a core internals changeout (CIC). Once changeout is complete, ATR Reactor Engineering utilizes previous CIC data, notably 1977-1994 CIC data, to conduct predictive criticality analysis on the new, unirradiated core. However, CIC data has been inconsistently reported over the years making it difficult, and in some cases impossible, to utilize. These inconsistencies arise in various forms of not using correct units, inconsistent diagram usage, and not portraying the same kind of data similarly across the reports. To work around this inconsistency issue, Reactor Engineering is implementing the use of several new neutronic modeling codes that utilize modern computation speeds and methods to model the new core in different criticality environments. Further validation is then conducted by nuclear testing and bringing the reactor critical and conducting various irradiation tests. Upon completion and certification that the reactor passed all testing requirements, ATR can once again re-start normal operations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Uncertainty quantification of mass models using ensemble Bayesian model averaging

Developments in the description of the masses of atomic nuclei have led to various nuclear mass models that provide predictions for masses across the whole chart of nuclides. These mass models play an important role in understanding the synthesis of heavy elements in the rapid neutron capture ( r ) process. However, it is still a challenging task to estimate the size of uncertainty associated with the predictions of each mass model. In this work, a method called ensemble Bayesian model averaging (EBMA) is introduced to quantify the uncertainty of one-neutron separation energies (S 1 n ) which are directly relevant in the calculations of r -process observables. Here, this Bayesian method provides a natural way to perform model averaging, selection, and uncertainty quantification, by combining the mass models as a mixture of normal distributions whose parameters are optimized against the experimental data, employing the Markov chain Monte Carlo method using the no-u-turn sampler. The EBMA model optimized with all the experimental S 1 n from the AME2003 nuclides are shown to provide reliable uncertainty estimates when tested with the new data in the AME2020.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma-Ray Simulated Spectrum Deconvolution of a LaBr₃ 1-in. x 1-in. Scintillator for Nondestructive ATR Fuel Burnup On-Site Predictions

A deconvolution method for a LaBr₃ 1"x1" detector for nondestructive Advanced Test Reactor (ATR) fuel burnup applications was developed. The method consisted of obtaining the detector response function, applying a deconvolution algorithm to 1”x1” LaBr₃ simulated, data along with evaluating the effects that deconvolution have on nondestructively determining ATR fuel burnup. The simulated response function of the detector was obtained using MCNPX as well with experimental data. The Maximum-Likelihood Expectation Maximization (MLEM) deconvolution algorithm was selected to enhance one-isotope source-simulated and fuel- simulated spectra. The final evaluation of the study consisted of measuring the performance of the fuel burnup calibration curve for the convoluted and deconvoluted cases. The methodology was developed in order to help design a reliable, high resolution, rugged and robust detection system for the ATR fuel canal capable of collecting high performance data for model validation, along with a system that can calculate burnup and using experimental scintillator detector data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data and Analysis from a Time-Resolved Tomographic Optical Beam Diagnostic

An optical tomographic diagnostic instrument developed for the acquisition of high-speed time-resolved images has been fielded at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed for the creation of time histories of electron-beam cross section through the collection of Cerenkov light. Four optical lines of sight optically collapse an image and relay projections via an optical fiber relay to recording instruments; a tomographic reconstruction algorithm creates the time history. Because the instrument may be operated in an adverse environment, it may be operated, adjusted, and calibrated remotely. The instrument was operated over the course of various activities during and after DARHT commissioning, and tomographic reconstructions reported verifiable beam characteristics. Results from the collected data and reconstructions and analysis of the data are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Activation and Thermoluminescent Detector Responses to a Bare Pulse of the CEA Valduc SILENE Critical Assembly

This benchmark experiment was conducted as a joint venture between the US Department of Energy (DOE) and the French Commissariat à l'Energie Atomique (CEA). Staff at the Oak Ridge National Laboratory (ORNL) in the US and the Centre de Valduc in France planned this experiment. The experiment was conducted on October 11, 2010 in the SILENE critical assembly facility at Valduc. Several other organizations contributed to this experiment and the subsequent evaluation, including CEA Saclay, Lawrence Livermore National Laboratory (LLNL), the Y-12 National Security Complex (NSC), Babcock International Group in the United Kingdom, and Los Alamos National Laboratory (LANL). The goal of this experiment was to measure neutron activation and thermoluminescent dosimeter (TLD) doses from a source similar to a fissile solution critical excursion. The resulting benchmark can be used for validation of computer codes and nuclear data libraries as required when performing analysis of criticality accident alarm systems (CAASs). A secondary goal of this experiment was to qualitatively test performance of two CAAS detectors similar to those currently and formerly in use in some US DOE facilities. The detectors tested were the CIDAS MkX and the Rocky Flats NCD-91. These detectors were being evaluated to determine whether they would alarm, so they were not expected to generate benchmark quality data.

Miller, Thomas Martin↗

Gamma/neutron analysis for SNM signatures at high-data rates(greater than 107 cps) for single-pulse active interrogation

We are developing a high data gamma/neutron spectrometer suitable for active interrogation of special nuclear materials (SNM) activated by a single burst from an intense source. We have tested the system at Naval Research Laboratory's (NRL) Mercury pulsed-power facility at distances approaching 10 meters from a depleted uranium (DU) target. We have found that the gamma-ray field in the target room 'disappears' 10 milliseconds after the x-ray flash, and that gamma ray spectroscopy will then be dominated by isomeric states/beta decay of fission products. When a polyethylene moderator is added to the DU target, a time-dependent signature of the DU is produced by thermalized neutrons. We observe this signature in gamma-spectra measured consecutively in the 0.1-1.0 ms time range. These spectra contain the Compton edge line (2.2 MeV) from capture in hydrogen, and a continuous high energy gamma-spectrum from capture or fission in minority constituents of the DU.

08 HYDROGEN↗

Material Design, Selection, and Manufacturing Methods for System Sustainment

This paper describes a material selection and validation process proven to be successful for manufacturing high-reliability long-life product. The National Secure Manufacturing Center business unit of the Kansas City Plant (herein called KCP) designs and manufactures complex electrical and mechanical components used in extreme environments. The material manufacturing heritage is founded in the systems design to manufacturing practices that support the U.S. Department of Energy’s National Nuclear Security Administration (DOE/NNSA). Material Engineers at KCP work with the systems designers to recommend materials, develop test methods, perform analytical analysis of test data, define cradle to grave needs, present final selection and fielding. The KCP material engineers typically will maintain cost control by utilizing commercial products when possible, but have the resources and to develop and produce unique formulations as necessary. This approach is currently being used to mature technologies to manufacture materials with improved characteristics using nano-composite filler materials that will enhance system design and production. For some products the engineers plan and carry out science-based life-cycle material surveillance processes. Recent examples of the approach include refurbished manufacturing of the high voltage power supplies for cockpit displays in operational aircraft; dry film lubricant application to improve bearing life for guided munitions gyroscope gimbals, ceramic substrate design for electrical circuit manufacturing, and tailored polymeric materials for various systems. The following examples show evidence of KCP concurrent design-to-manufacturing techniques used to achieve system solutions that satisfy or exceed demanding requirements.

36 MATERIALS SCIENCE↗

INL/JOU-17-41026-Rev000

Graphite creep strain data from the irradiation creep capsule Advanced Graphite Creep-1 (AGC-1) are reported. This capsule was the first (prototype) of a series of five or six capsules planned as part of the AGC experiment, which was designed to fully characterize the effects of neutron irradiation and the radiation creep behavior of current nuclear graphite. The creep strain data and analysis are reported for the six graphite grades incorporated in the capsule. The AGC-1 capsule was irradiated in the Advanced Test Reactor at Idaho National Laboratory (INL) at approximately 700°C and to a peak dose of 7 dpa (displacements per atom). The specimen’s final dose, temperature, and stress conditions have been reported by INL and were used during this analysis. The derived creep coefficients (K) were calculated for each grade and were found to compare well to literature data for the creep coefficient, even under the wide range of AGC-1 specimen temperatures. Comparisons were made between AGC-1 data and historical grade data for creep coefficients.

36 MATERIALS SCIENCE↗

Experimental study of the downstream effect of LOCA-generated debris on the pressure drop of full scale fuel assembly

The emergency core cooling system (ECCS) works to cool the reactor core in the event of a postulated loss-of-coolant accident (LOCA). The long-term reactor cooling water of ECCS comes from containment sump. Usually, the containment sump contains one or more screens to prevent the components of the ECCS from debris which could be washed into the sump. Large debris is blocked by the sump screens. However, some of the debris, such as fibrous, chemical precipitates and small particles may be ingested into the ECCS and subsequently into the reactor coolant systems (RCS), which would challenge the long-term core cooling (LTCC) and threaten the reactor core safety. NRC address this concern Generic Letter 2004-02. Westinghouse has evaluated the AP1000 1/4 height fuel assembly head-loss test in response to the issue. AVERA also perform the scaled 1/3 height mock-up fuel assembly test. The debris effect on the pressure drop of half-length mock-up PLUS7 fuel assembly of APR1400 were performed in KHNP. Numerical simulation by RELAP5-3D were performed for the debris-generated core blockage and full core as well as core bypass blockage condition were considered. However, the test in the works mentioned above use the scaled down FA (1/4, 1/3 or 1/2 length of a full FA), and didn't give the relationship between pressure drop and debris batches. The purpose of this study was to extend the debris effect to the full scale PWR fuel assembly, and identified batch by batch effect of debris to head loss of FA. The specific experimental procedure is concluded. The pressure drop test without adding debris is performed at the beginning and then three kinds of debris are added to the test loop step by step to test their effect on the pressure drop of fuel assembly. Two kinds of tests have been carried out, and the quantitative pressure data are obtained and analysis is provided. This work provides reliable and quantitative data for nuclear power plant (NPP) downstream effect analysis and safety analysis program, which is important to for licensing of NPP and further benchmark exercise. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗