Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Development of an Ultra-wide band Receiver for the North America Array

The North America Array (NAA), also known as the next-generation Very Large Array (ngVLA), is a concept for a radio astronomical interferometric array operating in the frequency range 1.2 GHz to 116 GHz and designed to provide substantial improvements in sensitivity, angular resolution, and frequency coverage while reducing operational costs compared to the current Jansky Very Large Array (JVLA). At JPL, we are designing a single receiver package designed to operate across the 8 to 48 GHz frequency range, in contrast to the current JVLA, which covers this frequency range with five receiver packages. Reducing the number of receiving systems required to cover the full frequency range would reduce operating costs. We are developing a prototype integrated feed-receiver package with a system noise temperature that meets the requirements of the ngVLA/NAA primary science programs, with a design that meets the requirement of low long-term operational costs. The receiver package being developed at JPL consists of a feed horn, low-noise amplifier (LNA), and down-converters to analog intermediate frequencies. We report on the status of this receiver package development.

Lazio, Joseph↗

Comparative Study of Commercial-Scale CO2 Storage Options in Single and Stacked Saline Formations in Managing Reservoir Pressure Buildup

Presentation at American Association of Petroleum Geologists (AAPG) Carbon, Capture, Utilization, and Storage (CCUS) held in Houston, Texas, April 25–27, 2023. The presentation emphasizes the importance of coordination among CO2 storage projects as CCUS deployment needs to be scaled up. The presentation focuses on findings from reservoir simulation studies in which different configurations of injection zones (a single saline formation and a stacked sequence of saline formations) are targeted for CO2 storage to accommodate the amplified storage volume needed while managing reservoir pressure buildup and interference induced by multi-well injection operations.

Wijaya, Nur↗

Gated truncated readout system

A gated truncated readout system for position sensitive or imaging detectors that improves resolution over traditional readout systems. The readout system includes two or more amplifiers that receive a multichannel output analog data from the detector. Analog gates control circuitry, included in the readout circuit, receives the signals from the amplifiers, determines a fractional value of the sum-integral of the signals, and enables analog gates operation around an area of interest, disabling all other channels where noise dominates the signal value and thereby improving interpolation accuracy of the signals centroid position and the detector resolution. Filtered signals are transmitted to a centroid interpolation signal processing device for computation of the centroid position. As a result disabling all channels where noise dominates the signal value, the gated truncated readout system provides better accuracy improved detector resolution.

Popov, Vladimir↗

Searching for Dark Matter with Superconducting Qubits

Dark matter is an enduring mystery in our quest to understand the fundamental constituents of our universe. Low mass bosons, such the axion or hidden photon, are compelling dark matter candidates. We leverage their potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon, to devise a method of detecting these candidates. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal and enable future searches, sub-SQL detection techniques are required.In this thesis, I report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum non-demolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to less than 1.68 x 10-15 in a band around 6.011 GHz (24.86 micro-eV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design, construction and evaluation of a 12.045 GHz, 2.0 kW-cw permanent-magnet focused klystron amplifier

An analytical and experimental program to demonstrate the technical feasibility of a lightweight, high-efficiency, 1-2 kW cw, permanent magnet focused klystron operating at 12.0 GHz was described. The design is based on use of a samarium-cobalt permanent magnet for focusing of the electron beam and choice of the most optimum parameters for maximum efficiency. A filter-loaded output circuit is used for the required bandwidth. The design incorporates a collector which is demountable from the tube to facilitate multistage depressed collector experiments, permitting replacement with a NASA-designed axisymmetric, electrostatic collector for linear beam microwave tubes. A further requirement is that the focusing field between the last interaction gap and the collector decay in a prescribed manner referred to as adiabatic expansion.

Nishida, J. M.↗

Low-stress creep behavior of multiple salt caverns under cyclic operations

Here, the use of multiple salt caverns for large-scale underground hydrogen storage offers a strategic solution to the growing demand for efficient and flexible energy storage, due to the inherent low permeability, high mechanical strength, and self-healing properties of the salt formation. Despite these advantages, the long-term geomechanical response of salt caverns under cyclic injection and withdrawal remains a significant challenge for ensuring operational stability. This mechanistic study highlights the critical role of low-stress creep, also known as pressure solution creep, in governing deformation of salt caverns during cyclic operations. Unlike conventional creep mechanisms that dominate under high-stress conditions, low-stress creep becomes particularly relevant under the moderate stress changes induced by repeated injection and withdrawal, which provides a previously underexplored control on cavern closure. Our three-dimensional computational model integrates the low-stress creep mechanism into the Munson–Dawson creep equation across a spectrum of operational scenarios including variations in cavern pressure cycles, injection-withdrawal frequencies, and caprock mechanical property. The low-stress creep components accelerate the cavern creep closure, which is amplified with shorter cycle frequency and larger pressure difference. Sensitivity analyses capture the complex interactions between multiple caverns and surround formations at the field scale that allows for a quantitative assessment of deformation patterns and closure rates over time and thereby informs the design and operation of sustainable underground hydrogen storage system.

Cyclic operation↗

Probing the density of states of two-level tunneling systems in silicon oxide films using superconducting lumped element resonators

We have investigated dielectric losses in amorphous silicon oxide (a-SiO) thin films under operating conditions of superconducting qubits (mK temperatures and low microwave powers). For this purpose, we have developed a broadband measurement setup employing multiplexed lumped element resonators using a broadband power combiner and a low-noise amplifier. The measured temperature and power dependences of the dielectric losses are in good agreement with those predicted for atomic two-level tunneling systems (TLS). By measuring the losses at different frequencies, we found that the TLS density of states is energy dependent. This had not been seen previously in loss measurements. These results contribute to a better understanding of decoherence effects in superconducting qubits and suggest a possibility to minimize TLS-related decoherence by reducing the qubit operation frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HEMT Frequency Doubler with Output at 300 GHz

An active frequency doubler in the form of an InP-based monolithic microwave integrated circuit (MMIC) containing a high-electron-mobility transistor (HEMT) has been demonstrated in operation at output frequencies in the vicinity of 300 GHz. This is the highestfrequency HEMT doubler reported to date, the next-highest-frequency active HEMT doubler having been previously reported to operate at 180 GHz. While the output power of this frequency doubler is less than that of a typical Schottky diode, this frequency doubler is considered an intermediate product of a continuing effort to realize the potential of active HEMT frequency doublers to operate with conversion efficiencies greater than those of passive diode frequency doublers. An additional incentive for developing active HEMT frequency doublers lies in the fact that they can be integrated with amplifiers, oscillators, and other circuitry on MMIC chips. The circuitry of the doubler MMIC (see Figure 1) features grounded coplanar waveguides. Air bridges and vias are used to make contact with the ground plane. The HEMT is biased for Class-A operation (in which current is conducted throughout each cycle of oscillation), which would ordinarily be better suited to linear amplification than to frequency doubling. Ordinarily, class-B operation (in which current is conducted during about half of each cycle of oscillation) would be more suitable for frequency doubling because of the essential nonlinearity of partial-cycle conduction. The reason for the unusual choice of class A was that computational simulations had shown that in this case, the efficiency in class B would be less than in class A. The input matching circuit of this doubler includes transmission lines that afford a good impedance match at the fundamental frequency, plus an open stub to prevent leakage of the second harmonic through the input terminals. The output circuit was designed to suppress the fundamental while providing a good match for the second harmonic.

Samoska, Lorene↗

The LCLS variable-energy hard X-ray single-shot spectrometer

The engineering design, implementation, operation and performance of the new variable-energy hard X-ray single-shot spectrometer (HXSSS) for the LCLS free-electron laser (FEL) are reported. The HXSSS system is based on a cylindrically bent Si thin crystal for dispersing the incident polychromatic FEL beam. A spatially resolved detector system consisting of a Ce:YAG X-ray scintillator screen, an optical imaging system and a low-noise pixelated optical camera is used to record the spectrograph. The HXSSS provides single-shot spectrum measurements for users whose experiments depend critically on the knowledge of the self-amplified spontaneous emission FEL spectrum. It also helps accelerator physicists for the continuing studies and optimization of self-seeding, various improved mechanisms for lasing mechanisms, and FEL performance improvements. The designed operating energy range of the HXSSS is from 4 to 20 keV, with the spectral range of order larger than 2% and a spectral resolution of 2 × 10 -5 or better. Those performance goals have all been achieved during the commissioning of the HXSSS.

Rich, David↗

Design and initial operation of multichord soft x-ray detection arrays on the STOR-M tokamak

Two miniature pinhole camera arrays for spatially and temporally resolved measurements of soft x-ray emission have been designed and installed on the STOR-M tokamak. Each array consists of a photodiode array, with one array viewing vertically and one viewing horizontally through a plasma cross section. Preamplifiers with fixed gains of 10{sup 5} V/A and custom built amplifiers with variable gains are used for signal amplification. Digitizers with 14 bit resolution and 3 MS/s sampling rate are used for data acquisition. In the initial operation, an Al foil with a thickness of 1.8 {mu}m installed for one array and Be filter of 7.6 {mu}m installed for the other array are used to test signal strength. Initial tests have identified sawtooth oscillations and 20 kHz fluctuations, which are also detected by Mirnov coils, superimposed on the sawtooth oscillations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A universal method for sensitive and cell-free detection of CRISPR-associated nucleases

A multitude of biological applications for CRISPR-associated (Cas) nucleases have propelled the development of robust cell-based methods for quantitation of on- and off-target activities of these nucleases. However, emerging applications of these nucleases require cell-free methods that are simple, sensitive, cost effective, high throughput, multiplexable, and generalizable to all classes of Cas nucleases. Current methods for cell-free detection are cumbersome, expensive, or require sophisticated sequencing technologies, hindering their widespread application beyond the field of life sciences. Developing such cell-free assays is challenging for multiple reasons, including that Cas nucleases are single-turnover enzymes that must be present in large excess over their substrate and that different classes of Cas nucleases exhibit wildly different operating mechanisms. Here, we report the development of a cell-free method wherein Cas nuclease activity is amplified via an in vitro transcription reaction that produces a fluorescent RNA:small-molecule adduct. We demonstrate that our method is sensitive, detecting activity from low nanomolar concentrations of several families of Cas nucleases, and can be conducted in a high-throughput microplate fashion with a simple fluorescent-based readout. We provide a mathematical framework for quantifying the activities of these nucleases and demonstrate two applications of our method, namely the development of a logic circuit and the characterization of an anti-CRISPR protein. We anticipate our method will be valuable to those studying Cas nucleases and will allow the application of Cas nuclease beyond the field of life sciences.

60 APPLIED LIFE SCIENCES↗

Resonant magnetic scattering with soft x-ray pulses from a free-electron laser operating at 1.59 nm

We report on a resonant magnetic scattering experiment using soft x-ray pulses generated from a free-electron laser (FEL). The free-electron laser was operated at a fundamental wavelength of 7.97 nm and radiation at the fifth harmonic originating from self-amplified stimulated emission at 1.59 nm with an average energy of 4 nJ per pulse was detected. We demonstrate the feasibility of resonant magnetic scattering at FEL sources by using a Co/Pd multilayer as prototype sample that was illuminated with 20-fs-long soft x-ray pulses tuned to the Co L{sub 3} absorption edge at 778.1 eV (1.59 nm)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low Cost Open-Path Instrument for Monitoring Atmospheric Carbon Dioxide at Sequestration Sites

In the past 48 months of the project, we have accomplished all objectives outlined in the proposal. In the first year, we demonstrated the technology for remote sensing on a bench top scale. The core electronics are designed and fabricated. We achieved results that will safely deliver the specifications outlined in the proposal. In the 2nd year, 2 major technical tasks outlined in the Statement of Objectives, i.e. Build a field test ready prototype of a long-range CO2 monitor, and characterize its performance in the short term and demonstrate that the monitor characteristics meet the goals set in the initial proposal, have been accomplished. We also conducted simulation work that defines the different deployment strategies for our sensors at sequestration sites. In the 3rd year, Specifications and Testing protocols have been developed for the CO2 monitor. 1% accuracy had been demonstrated in short period tests ({approx}1 hour). Unattended system operation and stability over a period of a week has been demonstrated with and without EDFA (laser power amplifier). The sensitivity of the instrument to CO2 leaks has been demonstrated. In the 4th no-cost extension year, we further field tested the system and the experience we accumulated give us a clear picture of what else are needed for final field deployment. These results have shown all the objectives of the project have been fulfilled. In July 2008, along with our commercial partner we won the DOE STTR phase I award to commercialize the instrument developed in this project - a testimony to the achievement of this research.

47 OTHER INSTRUMENTATION↗

RFI receiver

An S-band radio frequency interference (RFI) receiver to analyze and identify sources of RFI problems in the Deep Space Network DSN tracking stations is described. The RFI receiver is a constant gain, double conversion, open loop receiver with dual sine/cosine channel outputs, providing a total of 20 MHZ monitoring capability. This receiver is computer controlled using a MODCOMP II miniprocessor. The RFI receiver has been designed to operate at a 150 Kelvin system noise temperature accomplished by cascading two low noise field effect transistor (FET) amplifiers for the receiver front-end. The first stage low noise FET amplifier is mounted at the feed horn to minimize any cable losses to achieve a lower system noise temperature. The receiver is tunable over the frequency range of 2150 to 2450 MHz in both sine/cosine output channels with a resolution of 100 kHz.

Lay, R.↗

A pulsed CO2 Doppler lidar for boundary layer monitoring

A monostatic, master oscillator power amplifier (MOPA), CO2 pulsed Doppler lidar was constructed and tested. The system is compact (120 x 60 cm), operates at high pulse repetition rates (greater than 1 kHz) and is intended for simultaneous Doppler/Differential Absorption Lidar (DIAL) monitoring of the planetary boundary layer. Details of the system design, hard target calibrations, and aerosol returns are presented.

Pearson, Guy N.↗

Self-Amplified Optical Pattern Recognizer

Self-amplified optical pattern recognizers developed for use in recognition of patterns, in optical computing, and in optoelectronic neural networks. In recognizer, photorefractive crystal serves as medium in which one holographically records diffraction-grating filter representing pattern with which recognition sought. Apparatus "self-amplified" because signal amplified within filter to many orders of magnitude greater than in prior optical pattern recognizers. Basic principle of operation applicable to many types of correlation filters, including (but not limited to) Vander Lugt matched filters, joint-transform filters, and phase-only filters.

Liu, Hua-Kuang↗

Research and Development of Laser Diode Based Instruments for Applications in Space

Laser diode technology continues to advance at a very rapid rate due to commercial applications such as telecommunications and data storage. The advantages of laser diodes include, wide diversity of wavelengths, high efficiency, small size and weight and high reliability. Semiconductor and fiber optical-amplifiers permit efficient, high power master oscillator power amplifier (MOPA) transmitter systems. Laser diode systems which incorporate monolithic or discrete (fiber optic) gratings permit single frequency operation. We describe experimental and theoretical results of laser diode based instruments currently under development at NASA Goddard Space Flight Center including miniature lidars for measuring clouds and aerosols, water vapor and wind for Earth and planetary (Mars Lander) use.

Krainak, Michael↗

Super Photon Counters

The perfect photon detector would measure the arrival time, the energy, the polarization, and the position of every arriving quantum, but that is easier said than done. Two groups have now succeeded in doing time-resolved spectroscopy on the Crab Nebula pulsar, measuring everything but the polarization, with reports from Romani et al. at Stanford and from Perryman et al. at ESTEC. Both groups use superconducting detectors to gain the necessary speed and sensitivity. The photon can heat the electrons in a superconductor biased in the middle of its resistive transition, or break bound superconducting electron-hole pairs, which can then be collected. Three years ago, Peacock et al. reported that they had detected single optical photons with a superconducting tunnel junction (STJ), and Paresce wrote a News and Views article. A tunnel junction uses two pieces of conductive material, separated by a tiny gap of insulating material or even vacuum. If the gap is thin enough, electrons can tunnel across anyway, and if the conductors are superconductors, the junction displays very useful quantum mechanical properties and electrical nonlinearities. Amplifiers, detectors, oscillators, and computer circuits can all be made from them. Their special advantage is that they operate at very low temperatures, dissipate very little power, operate very fast, and are very small.

Mather, John↗