Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERMANENT MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Transverse forces in the CBETA v6/v6.5 magnets

These 2D transverse force calculations were done for the following Halbach magnet types in the CBETA design as it currently stands (an implementation of the April 10, 2017 lattice). These magnets are made out of two longitudinally-­stacked layers of permanent magnet blocks.

43 PARTICLE ACCELERATORS↗

Steps to achieving high-resolution NMR spectroscopy on solutions at GPa pressure

Recent theoretical advances and molecular-dynamic estimates of the dielectric constant of water have extended the HKF model for aqueous solution chemistry up to 6.0 gigapascals (GPa), which are conditions well beyond the capabilities of conventional NMR spectroscopy (Pan et al., 2013; Sverjensky et al., 2014, see also Wasserman and others, 1995). These developments provide strong motivation to design a simple NMR probe that allows experiments on solutions, at high resolution, to pressures of a few GPa (Pautler et al., 2014; Ochoa et al., 2015; 2016). Here we describe the performance of a compact NMR probe that can reach several GPa pressures. The probe is made by placing a solenoid microcoil inside of a standard piston-cylinder device used in solid-state physics. High pressures are achieved in the sample by applying force to a coaxial piston. Early designs of the probe, although useful, were limited in sample size to ~10-15μL. Here we describe modifications that allow greatly improved resolution and sensitivity, including 1H-1H NMR correlation spectroscopy, on solutions at 2.8 GPa pressure. Sample sizes can be expanded if, instead of a standard NMR spectrometer that is built around a superconducting magnet, one employs a magnetic-resonance imaging (MRI) system that is built around a permanent magnet. The MRI systems can apply larger magnetic field gradients than conventional spectrometers, and thus have more robust shimming capability, which is needed because of the juxtaposition of different alloys in the pressure cell. More importantly, these systems can have magnetic fields that are oriented perpendicular to the magnet bore, which allows rotation of the coil within the axis of the pressure cell to increase sample volumes and pressure. Sensitivity is improved by replacing the traditional, but reduced-volume, closed sample container mounted in the center of the NMR detection coil with an open NMR coil that dangles freely in solution, thus making the sample solution itself the pressure-transmission fluid. The efficacy of these modifications are demonstrated by measuring 1 H NMR spectra for ethyl alcohol and ethyl alcohol/methyl alcohol mixtures at pressures up to 2.8 GPa. As a result, further developments are discussed that will allow geochemists to acquire aqueous solution NMR spectra at higher 3-4 GPa pressures.

58 GEOSCIENCES↗

A Small Nano-Kelvin Resolution Thermometer for Low Temperature Experiments in Space

A small high resolution paramagnetic susceptibility thermometer was developed using a GdCl3 paramagnetic salt. The device uses a SQUID magnetometer to determine the temperature dependent magnetization of the salt in a magnetic field. The required magnetic field is provided by a pair of small SmCo permanent magnet disks situated inside the thermometer housing. This eliminates the use of a heavy charging solenoid in a conventional SQUID based magnetic thermometer system using a flux tube. This thermometer can resolve approximately 10(exp -9)K near the liquid-gas critical point of The (approx. 3.31K). The drift in the thermometer is less than 2 x 10(exp -13) K/s. This light weighted thermometer (approx. 7 g) is a candidate for use in future International Space Station flight low temperature experiments.

Welander, Paul↗

The NASA Inductrack Model Rocket Launcher at the Lawrence Livermore National Laboratory

The Inductrack magnetic levitation system, developed at the Lawrence Livermore National Laboratory, is being studied for its possible use for launching rockets. Under NASA sponsorship, a small model system is being constructed at the Laboratory to pursue key technical aspects of this proposed application. The Inductrack is a passive magnetic levitation system employing special arrays of high-field permanent magnets (Halbach arrays) on the levitating carrier, moving above a "track" consisting of a close-packed array of shorted coils with which are interleaved with special drive coils. Halbach arrays produce a strong spatially periodic magnetic field on the front surface of the arrays, while canceling the field on their back surface. Relative motion between the Halbach arrays and the track coils induces currents in those coils. These currents levitate the carrier cart by interacting with the horizontal component of the magnetic field. Pulsed currents in the drive coils, synchronized with the motion of the carrier, interact with the vertical component of the magnetic field to provide acceleration forces. Motional stability, including resistance to both vertical and lateral aerodynamic forces, is provided by having Halbach arrays that interact with both the upper and the lower sides of the track coils. In its completed form the model system that is under construction will have a track approximately 100 meters in length along which the carrier cart will be propelled up to peak speeds of Mach 0.4 to 0.5 before being decelerated. Preliminary studies of the parameters of a full-scale system have also been made. These studies address the problems of scale-up, including means to simplify the track construction and to reduce the cost of the pulsed-power systems needed for propulsion.

Tung, L. S.↗

Spectral characterization of flash and high flux x-ray radiographic sources with a magnetic Compton spectrometer

In this article, we present a new analysis method applied to revitalize permanent magnet Compton spectrometers used to measure photon energy spectra in the MeV range. The inversion of the measured electron distribution to determine the original photon distribution is achieved via a method of consistent coupled radiation transport and magnetic field mapping of the input photon spectra to the measured electron distribution. The method of linear least squares was used to perform the unfolding of the electron distribution to the initial photon spectra, without any assumptions made regarding the electron distribution. We present an application of this method to data from a nominal 19.4 MeV flash radiographic source (the first axis of the Dual Axis Radiographic Hydro-Test Facility) capable of generating 500 R @ 1 m in ~60 ns and a medical therapy source (a Scanditronix M22, Microtron) capable of variable energies with nominal endpoints of 6, 10, 15, and 20 MeV and an output of ~1000–2000 R/min @ 1 m. The results provide agreement between the modeled and unfolded experimentally measured photon spectra as quantified by statistical tests, from 1.5 to 20 MeV. Experimental results are presented as well as a discussion of the novel MCNP6-based simulations and methods for reconstruction of the spectra.

47 OTHER INSTRUMENTATION↗

Accelerator Physics Lessons From CBETA, the First Multi-turn SRF ERL

The Cornell-BNL ERL Test Accelerator (CBETA) has been designed, constructed, and commissioned in a collaboration between Cornell and Brookhaven National Laboratory (BNL). It focuses on energy-saving measures in accelerators, including permanent magnets, energy recovery, and superconductors; it has thus been referred to as a green accelerator. CBETA has become the world's first Energy Recovery Linac (ERL) that accelerates through multiple turns and then recovers the energy in superconducting radiofrequency (SRF) cavities though multiple decelerating turns. The energy is then available to accelerate more beam. It has also become the first accelerator that operates 7 beams in the same large-energy aperture Fixed Field Alternating-gradient (FFA) lattice. The FFA is constructed of permanent combined function magnets and transports energies of 42, 78, 114, and 150 MeV simultaneously. Accelerator physics lessons from the commissioning period will be described and applications of such an accelerator from hadron cooling to EUV lithography and from nuclear physics to a compact Compton source will be discussed.

Deitrick, K. E.↗

Quasipermanent magnets of high temperature superconductor - Temperature dependence

We report on persistent field in quasi-permanent magnets of high temperature superconductors. Magnets composed of irradiated Y(1+)Ba2Cu3O7 trapped field Bt = 1.52 T at 77 K and 1.9 T at lower temperature. However, the activation magnet limited Bt at lower temperature. We present data on Jc(H,T) for unirradiated materials, and calculate Bt at various T. Based upon data at 65 K, we calculate Bt in unirradiated single grains at 20 K and find that 5.2 T will be trapped for grain diameter d about 1.2 cm, and 7.9 T for d = 2.3 cm. Irradiated grains will trap four times these values.

Chen, In-Gann↗

Superstructure magnetic anisotropy in Fe 3 O 4 nanoparticle chains

Magnetic anisotropy is essential for many applications of ferromagnetic/ferrimagnetic materials, including permanent magnets and magnetic recording media. Attempts have been made recently to build up 3-D nanoparticle and quantum dot assemblies, however, it is not understood yet if a nanoparticle assembly can possess high magnetic anisotropy with low anisotropic materials. In this article, we report our discovery of high magnetic anisotropy resulted from Fe 3 O 4 nanoparticle chains. We started with closely-packed nanoparticle assemblies of spherical Fe 3 O 4 nanoparticles that exhibit low magnetocrystalline anisotropy and shape anisotropy, and corresponding negligible coercivity. When the nanoparticle assemblies are compressed under pressure, they form bundles or arrays that consist of Fe 3 O 4 chains with a length scale of several hundred nanometers. Magnetic measurements show that these Fe 3 O 4 chain arrays possess a high uniaxial magnetic anisotropy (K eff ~ 2.9×10 5 J/m 3 ) and significant magnetic coercivity. Our simulations reveal that interparticle magnetic dipolar interactions contribute to this type of superstructure magnetic anisotropy. This study demonstrates the feasibility and approaches to create “patterned” high magnetic anisotropy in nanoparticle superstructures/assemblies.

Mohapatra, Jeotikanta (ORCID:0000000151968626)↗

Distinct effect of Kondo physics on crystal field splitting in electron and spin spectroscopies

Magnetic anisotropy is a key feature of rare earth materials from permanent magnets to heavy fermions. Here we explore the complex interplay of Kondo physics and anisotropy, and their effect on different experimental probes of magnetic anisotropy in a minimal 𝐽=3/2 Anderson impurity model using the numerical renormalization group. While anisotropy suppresses Kondo screening, virtual valence fluctuations enhance the anisotropy. We find distinct renormalization of the magnetic anisotropy measured via dynamical spin response (inelastic neutron scattering) versus electronic excitations in the impurity spectral function (resonant inelastic x-ray and scanning tunneling spectroscopy). The two measurement types have different responses and dependencies on the temperature and Kondo scales.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Active Measurement of Plasma Parameters in Over-Dense MFE Reactor Plasma Using High Frequency Beat-Wave Resonantly Generated Thermal Bernstein Waves

UC Davis was funded to explore the combination of beat-wave excitation and laser scattering to make completely non-invasive determination of local plasma conditions. This involves the use of two high frequency mm-wave sources of differing frequencies (the pump waves) to excite plasma waves at the difference of the frequencies, which is known as the beat frequency. The difference frequency or the frequency of the beat wave is chosen so that we produce plasma waves whose fluctuating electron density is a sensitive function of plasma parameters at the location where the source waves overlap. This fluctuation can be detected from outside the plasma, by measuring the deflection of a probe beam directed at the overlap region between the two pump waves (i.e., collective scattering). This work is an extension of mm-wave frequencies of a 10 GHz beat-wave experiment conducted on the DDT toroidal device (see Fig. 1) in a magnetized plasma where the excited Langmuir wave is replaced by the magnetized upper hybrid wave. Here, two high power (> 1 kW) ~94 GHz pump sources will be employed to match the upper hybrid resonance. The primary envisioned experiment is to drive the electron Bernstein wave (EBW) in the interior of a magnetized plasma. The EBW is a hot-plasma electrostatic wave, which cannot propagate in vacuum. Roots of the EBW dispersion relation occur at frequencies slightly higher than harmonics of the electron cyclotron frequency. Use of the EBW has particular advantages for measuring plasma magnetic field in plasmas with relatively high density and low magnetic field, as is the case in spherical tokamaks. This is the “over dense” condition of future efficient high beta magnetic confinement fusion reactors such as the spherical tokamak (STs). The overarching goal of the proposed project is to demonstrate beat wave EBW excitation in low density and temperature parameters that are directly scalable to over-dense spherical tokamaks such as NSTX or MAST, where measurement of magnetic field by electron cyclotron emission (ECE) is experimentally complex, and requires models of plasma profiles in order to interpret results. In such experiments, availability of point measurements of magnetic field strength provided by a beat-wave diagnostic would serve as a powerful independent check on the ECE results, serving to validate the assumed profiles and wave-propagation models used. The first step was to assemble/modify the target chamber in which the beat-wave plasma experiments will take place. Here, the target chamber of the CTIX compact-toroid (spheromak) injector was chosen. At the time that the proposal was submitted, the aim was to conduct the experiments in the CTIX experimental facilities located at the Livermore campus of UC Davis using microwave/mm-wave equipment brought from the main campus., However, by the time DoE funds for this project were awarded, the CTIX experimental facilities located at the Livermore campus of UC Davis were in the process of being shut down due to the closure of the Livermore campus by Lawrence Livermore National Laboratory (LLNL). Consequently, the equipment needed for this project was crated up and shipped from Livermore to Davis as part of the laboratory shutdown after space on campus was secured and College of Engineering approval secured. Once it arrived in Davis on December 20, 2018, work on the project began in earnest with the initial efforts directed toward developing a new plasma target source. Because of the shutdown of the CTIX facility, the scope of the project thus had to be reduced due to the abbreviated amount of time allocated to the project once the shutdown/move had been completed. Chamber modifications have been completed, including the fabrication and installation of a 38 GHz interferometer, as described in Sec. 3. The thermionic plasma source has been tested and characterized. The magnetic field required for the EBW experiments will be generated by permanent magnets mounted on plates positioned above and below the chamber. Magnetic simulations have been performed, and show that a 3-ring magnet arrangement on each plate, with a plate separation of 50 cm, is required to achieve the ~100 G uniform magnetic field in the interaction region that we feel is necessary to ensure good EBW coupling. We proved unable to successfully revive either of Prof. Luhmann’s two high power (≥20 kW) 94 GHz millimeter-wave sources after their extended time in storage and decided to postpone further efforts and concentrate on slightly lower power sources. Consequently, we were successful in reviving a ~2 kW extended klystron amplifier (EIK), which together with a ~2 kW extended interaction oscillator (EIO) will provide the two pump sources required for the project. Safe operation of the EIO requires extensive modifications to one of Prof. Luhmann’s pulse modulators - these modulator modifications are ongoing, which has unfortunately delayed the planned beat-wave experiments. Details of this work are provided in Sec. 3. Even though project funding has now ended, we still plan to proceed to complete the EIO pulse modulator modifications, install the two ~94 GHz pump wave sources on the target chamber, and conduct unmagnetized tests of the beat-wave concept which involve coupling to unmagnetized electron plasma waves rather than magnetized EBWs. Should these experiments prove successful, we plan to submit a follow-up proposal for additional funding which would allow us to undertake the magnetized EBW experiments.

42 ENGINEERING↗

Magnetic suspension and balance system advanced study

An improved compact design for a superconducting magnetic suspension and balance system for an 8 ft. x 8 ft. transonic wind tunnel is developed. The original design of an MSBS in NASA Cr-3802 utilized 14 external superconductive coils and a superconductive solenoid in the airplane test model suspended in a wind tunnel. The improvements are in the following areas: test model solenoid options, dynamic force limits on the model, magnet cooling options, structure and cryogenic designs, power supply specifications, and cost and performance evaluations. The improvements are: MSBS cost reduction of 28%, weight; reduction of 43%, magnet system ampere-meter reduction of 38%, helium liquifier capacity reduction by 33%, magnet system stored energy reduction by 55%, AC loss to liquid helium reduced by 76%, system power supply reduced by 68%, test coil pole strength increased by 19%, wing magnetization increased by 40%, and control frequency limit increased by 200% from 10 Hz to 30 Hz. The improvements are due to: magnetic holmium coil forms in the test model, better rare earth permanent magnets in the wings, fiberglass-epoxy structure replacing stainless steel, better coil configuration, and new saddle roll coil design.

Boom, R. W.↗

Planar rotational magnetic micromotors with integrated shaft encoder and magnetic rotor levitation

Deep x-ray lithography and electroplating may be combined to form a fabrication tool for micromechanical devices with large structural heights, to 500 micron, and extreme edge acuities, less than 0.1 micron-run-out per 100 micron of height. This process concept which originated in Germany as LIGA may be further extended by adding surface micromachining. This extension permits the fabrication of precision metal and plastic parts which may be assembled into three-dimensional micromechanical components and systems. The processing tool may be used to fabricate devices from ferromagnetic material such as nickel and nickel-iron alloys. These materials when properly heat treated exhibit acceptable magnetic behavior for current to flux conversion and marginal behavior for permanent magnet applications. The tool and materials have been tested via planar, magnetic, rotational micromotor fabrication. Three phase reluctance machines of the 6:4 configuration with 280 micron diameter rotors have been tested and analyzed. Stable rotational speeds to 34,000 rpm with output torques above 10 x 10(exp -9) N-m have been obtained. The behavior is monitored with integrated shaft encoders which are photodiodes which measure the rotor response. Magnetic levitation of the rotor via reluctance forces has been achieved and has reduced frictional torque losses to less than 1 percent of the available torque. The results indicate that high speed limits of these actuators are related to torque ripple. Hysteresis motors with magnetic bearings are under consideration and will produce high speed rotational machines with excellent sensor application potential.

Guckel, Henry↗

System identification of the Large-Angle Magnetic Suspension Test Fixture (LAMSTF)

The Large-Angle Magnetic Suspension Test Fixture (LAMSTF), a laboratory-scale research project to demonstrate the magnetic suspension of objects over wide ranges of attitudes, has been developed. This system represents a scaled model of a planned Large-Gap Magnetic Suspension System (LGMSS). The LAMSTF consists of a small cylindrical permanent magnet suspended element which is levitated above a planar array of five electromagnets mounted in a circular configuration. The cylinder is a rigid body and can be controlled to move in five independent degrees of freedom. Six position variables are sensed indirectly by using infrared light-emitting diodes and light-receiving phototransistors. The motion of the suspended cylinder is in general nonlinear and hence only the linear, time-invariant perturbed motion about an equilibrium state is considered. One of the main challenges in this project is the control of the suspended element over a wide range of orientations. An accurate dynamic model plays an essential role in controller design. The analytical model is first derived and open-loop characteristics discussed. The system is shown to be highly unstable and requires feedback control for system identification. Projection filters are first proposed to identify the state space model from closed-loop input/output test data in the time domain. This method is then extended to identify linear systems from the frequency test data. A canonical transformation matrix is also derived to transform the identified state space model into the physical coordinate. The LAMSTF system is stabilized by using a linear quadratic regulator (LQR) feedback controller for closed-loop identification. The rate information is obtained by calculating the back difference of the sensed position signals. Only the closed-loop random input/output data are recorded. Preliminary results from numerical simulations demonstrate that the identified system model is fairly accurate from either time domain or frequency-domain data. Experiments will be performed to validate the proposed closed-loop identification algorithms.

Huang, Jen-Kuang↗

Modeling and Identification of a Large Gap Magnetic Suspension System

This paper presents the results of modeling and system identification efforts on the NASA Large-Angle Magnetic Suspension Test Fixture (LAMSTF). The LAMSTF consists of a cylindrical permanent magnet which is levitated above a planar array of five electromagnets mounted in a circular configuration. The analytical model is first developed and open-loop characteristics are described. The system is shown to be highly unstable and requires feedback control in order to apply system identification. Limitations on modeling accuracy due to the effect of eddy-currents on the system are discussed. An algorithm is derived to identify a state-space model for the system from input/output data acquired during closed-loop operation. The algorithm is tested on both the baseline system and a perturbed system which has an increased presence of eddy currents. It is found that for the baseline system the analytic model adequately captures the dynamics, although the identified model improves the simulation accuracy. For the system perturbed by additional unmodeled eddy-currents the analytic model is no longer adequate and a higher-order model, determined through system identification, is required to accurately predict the system's time response.

Cox, David E.↗

Simplified Analytical Model of a Six-Degree-of-Freedom Large-Gap Magnetic Suspension System

A simplified analytical model of a six-degree-of-freedom large-gap magnetic suspension system is presented. The suspended element is a cylindrical permanent magnet that is magnetized in a direction which is perpendicular to its axis of symmetry. The actuators are air core electromagnets mounted in a planar array. The analytical model consists of an open-loop representation of the magnetic suspension system with electromagnet currents as inputs.

Groom, Nelson J.↗

A New Small Nano-Kelvin Resolution Thermometer for Low Temperature Experiments

A small, high resolution paramagnetic susceptibility thermometer was developed using a GdCl3 paramagnetic salt. The device uses a SQUID (Superconducting Quantum Interference Device) magnetometer to determine the temperature dependent magnetization of the salt in a magnetic field. The magnetic field is provided by a pair of small samarium cobalt permanent magnet disks situated inside the thermometer housing. The eliminates the need for a heavy, charging solenoid used in a conventional SQUID based magnetic thermometer system. This thermometer can resolve approximately 10 (exp -9)K near the liquid-gas critical point of He-3(approximately 3.31K). The drift rate of the thermometer was measured to be less than 2 x 10 (exp -13) K per second. This light weight thermometer (approximately 7 g) is a candidate for use in future low temperature Space Shuttle and International Space Station experiments. The present thermometer design easily permits a variety of magnetic materials for use in other applications.

Welander, Paul↗

Toughening Sm–Co sintered magnets via microstructure modification with additives

We report the mechanical properties of the brittle Smsingle bondCo permanent magnets are of great practical significance. However, studies on the magnets have mostly focused on their magnetic properties. This paper reports the modified microstructure and refined unimodal grain size, enhanced flexural strength, and magnetic properties of Sm 2 (Co,Fe,Cu,Zr) 17 sintered magnets doped with La 2 O 3 , MgO, and CaF 2 fine particulates. The correlations between microstructure, phase composition, and mechanical and magnetic properties were studied. Doping of a small amount (e.g., 0.5–3 wt%) of La 2 O 3 , MgO, or CaF 2 fine particulates could significantly refine the unimodal grain sizes of the Smsingle bondCo magnets via the Zener pinning effect. Moreover, doping significantly improved the flexural strengths σ of the magnets. For example, the σ values of the magnets with 0.5 wt% MgO, 1 wt% La 2 O 3 , and 1 wt% CaF 2 were approximately 65%, 63%, and 42% higher than that of the reference magnet, respectively. Micromechanical simulations revealed that the fine particles of La 2 O 3 could deflect crack growth, while the CaF 2 particles could attract or arrest cracks during the fracture process. The mechanical strengthening effect was mainly due to grain size refinement. The Smsingle bondCo magnets with 0.5–1.5 wt% CaF2 and 0.5 wt% La 2 O 3 exhibited excellent magnetic properties while doping 1–3 wt% La2O3 and 0.5–3 wt% MgO deteriorated magnetic performance. The rational design of CaF 2 - or La 2 O 3 -doped microstructure can be an economical and effective method for producing toughened Sm–Co sintered magnets with high magnetic performance.

36 MATERIALS SCIENCE↗

Element-resolved magnetism across the temperature- and pressure-induced spin reorientation in MnBi

Rare-earth free permanent magnet MnBi (NiAs-type crystal structure) displays strong magnetic anisotropy above its 90 K spin reorientation transition (SRT). X-ray magnetic circular dichroism (XMCD) shows induced magnetism in Bi 5d band, which is strongly coupled to the magnetism of Mn. A clear increase in Bi orbital-to-spin moment ratio is observed above the SRT. Hydrostatic pressure mimics the e*ect of temperature on the SRT, and the pressure effect also leads to anisotropic lattice contraction, which is known to be induced by cooling. These results reveal that temperature and pressure can similarly induce the coupled structural and magnetic responses, suggesting the importance of the anisotropic lattice change and Mn-Bi hybridization to the magnetic anisotropy change across the SRT.

36 MATERIALS SCIENCE↗