Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Trace”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

BrzostekEcologyLab/CORPSE-soil-jars

Efforts to manage soils for carbon (C) sequestration remain limited by our understanding of how differences in plant traits and microbial traits mechanistically drive soil organic C (SOC) storage. Addressing this uncertainty is particularly critical in bioenergy agriculture, due to its potential to enhance soil C and provide a C neutral fuel. As such, we examined differences between two contrasting feedstocks, Zea mays (corn) and Miscanthus x giganteus (miscanthus), in the ability of their litter to form new chemically resistant particulate SOC vs. physically protected mineral associated SOC and used this data to improve the parameterization of a microbial SOC model. We tested a hypothesized conceptual model whereby easy to decompose corn litters drive greater microbial carbon use efficiency (CUE) and the formation of more mineral associated SOC over particulate SOC than more complex miscanthus litters. To do this, we performed a soil microcosm experiment where we added 13C enriched aboveground and belowground litters to soils and traced the fate of the 13C into microbial respiration and SOC pools. We found that corn litters promoted higher microbial CUE (0.37) than miscanthus litters (0.24). In turn, corn litter formed approximately 50% more mineral associated SOC than miscanthus litters. Similarly, structurally complex root litters promoted a lower CUE and formed less mineral associated SOC than leaf and shoot litters for both crops. When we used our data to parameterize the SOC model, we found that modeling microbial trait differences uniquely allowed the model to capture the fate of litter C in SOC. Collectively, we found a robust link between litter quality, microbial efficiency, and the formation of SOC. This link bridges the empirical uncertainty in how different crops can form new soil C and provides an empirical basis for modeling SOC transformations.

Ridgeway, Joanna↗

Broadband astigmatism-free Czerny-Turner imaging spectrometer using spherical mirrors

We describe the elimination of the astigmatism of a Czerny-Turner imaging spectrometer, built using spherical optics and a plane grating, over a broad spectral region. Starting with the principle of divergent illumination of the grating, which removes astigmatism at one chosen wavelength, we obtain design equations for the distance from the grating to the focusing mirror and the detector angle that remove the astigmatism to first order in wavelength. Experimentally, we demonstrate near diffraction-limited performance from 740 to 860 nm and over a 5 mm transverse spatial extent, while ray-tracing calculations show that barring finite-aperture and detector size limitations, this range extends from 640 to 900 nm and over 10 mm transversely. Our technique requires no additional optics and uses standard off-the-shelf components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evolution of the 1-mlb mercury ion thruster subsystem

The developmental history, performance, and major lifetests of each component of the present 1-mlb (4.5 mN) thruster system are traced over the past 10 years. The 1-mlb thruster subsystem consists of an 8 cm diameter ion thruster mounted on 2 axis gimbals, a mercury propellant tank, a power electronics unit, a controller/digital interface unit, and necessary electrical harnesses plus propellant tankage and feed lines.

Kerslake, W. R.↗

Aspheric concave grating spectrographs

The design of aspheric concave gratings for high-resolution spectroscopes is examined theoretically, using the requirements of the proposed Far-UV Spectroscopic Explorer (effective area 100 sq cm and lambda/delta lambda = 30,000 in the 90-120-nm range) as a concrete example and taking the limitations of current fabrication technology (straight grooves only and maximum density 6000 lines/mm) into account. The total-path function derived by Namioka (1961) for an ellipsoidal grating is subjected to aberration analysis to obtain the optical surface best suited to the design requirements; expressions for corrections to the conventional stigmatic Rowland-circle mount are obtained and shown to produce significant performance improvements; and the design advantages of coma-corrected non-Rowland geometries are explored. Ray tracings and deviation contours are provided.

Cash, W. C., Jr.↗

Advances in high chamber pressure propulsion

NASA has been involved in the development of improved high thrust booster rocket engines to meet the propulsion requirements of launch vehicles such as the Space Shuttle. Solutions that NASA/Marshall Space Flight Center pursued to accomplish the high performance, long life goals set for SSME are discussed. In addition, currently projected requirements for liquid rocket engines have identified liquid oxygen/hydrocarbon-fueled engines for booster application in the near future. These advanced hydrocarbon-fueled engines will require improvements in performance and life to be suitable for their projected missions. Raising chamber pressure to increase performance and reduce engine envelope are the key objectives in hydrocarbon-fueled engine technology. This paper traces the history of advances in high pressure rocket engine systems and the challenges it presents.

Mccool, A. A.↗

Electrostatic Discharge Effects on Thin Film Resistors

Recently, open circuit failures of individual elements in thin film resistor networks have been attributed to electrostatic discharge (ESD) effects. This paper will discuss the investigation that came to this conclusion and subsequent experimentation intended to characterize design factors that affect the sensitivity of resistor elements to ESD. The ESD testing was performed using the standard human body model simulation. Some of the design elements to be evaluated were: trace width, trace length (and thus width to length ratio), specific resistivity of the trace (ohms per square) and resistance value. However, once the experiments were in progress, it was realized that the ESD sensitivity of most of the complex patterns under evaluation was determined by other design and process factors such as trace shape and termination pad spacing. This paper includes pictorial examples of representative ESD failure sites, and provides some options for designing thin film resistors that are ESD resistant. The risks of ESD damage are assessed and handling precautions suggested.

Sampson, Michael J.↗

Microfluidic Extraction of Biomarkers using Water as Solvent

A proposed device, denoted a miniature microfluidic biomarker extractor (mu-EX), would extract trace amounts of chemicals of interest from samples, such as soils and rocks. Traditionally, such extractions are performed on a large scale with hazardous organic solvents; each solvent capable of dissolving only those molecules lying within narrow ranges of specific chemical and physical characteristics that notably include volatility, electric charge, and polarity. In contrast, in the mu-EX, extractions could be performed by use of small amounts (typically between 0.1 and 100 L) of water as a universal solvent. As a rule of thumb, in order to enable solvation and extraction of molecules, it is necessary to use solvents that have polarity sufficiently close to the polarity of the target molecules. The mu-EX would make selection of specific organic solvents unnecessary, because mu-EX would exploit a unique property of liquid water: the possibility of tuning its polarity to match the polarity of organic solvents appropriate for extraction of molecules of interest. The change of the permittivity of water would be achieved by exploiting interactions between the translational states of water molecules and an imposed electromagnetic field in the frequency range of 300 to 600 GHz. On a molecular level, these interactions would result in disruption of the three-dimensional hydrogen-bonding network among liquid-water molecules and subsequent solvation and hydrolysis of target molecules. The mu-EX is expected to be an efficient means of hydrolyzing chemical bonds in complex macromolecules as well and, thus, enabling analysis of the building blocks of these complex chemical systems. The mu-EX device would include a microfluidic channel, part of which would lie within a waveguide coupled to an electronically tuned source of broad-band electromagnetic radiation in the frequency range from 300 to 600 GHz (see figure). The part of the microfluidic channel lying in the waveguide would constitute an interaction volume. The dimensions of the interaction volume would be chosen in accordance with the anticipated amount of solid sample material needed to ensure extraction of sufficient amount of target molecules for detection and analysis. By means that were not specified at the time of reporting the information for this article, the solid sample material would be placed in the interaction volume. Then the electromagnetic field would be imposed within the waveguide and water would be pumped through the interaction volume to effect the extraction.

Amashukeli, Xenia↗

Mode Tracker for Mode-Hop-Free Operation of a Laser

A mode-tracking system that includes a mode-controlling subsystem has been incorporated into an external-cavity (EC) quantum cascade laser that operates in a mid-infrared wavelength range. The mode-tracking system makes it possible to perform mode-hop-free wavelength scans, as needed for high-resolution spectroscopy and detection of trace gases. The laser includes a gain chip, a beam-collimating lens, and a diffraction grating. The grating is mounted on a platform, the position of which can be varied to effect independent control of the EC length and the grating angle. The position actuators include a piezoelectric stage for translation control and a motorized stage for coarse rotation control equipped with a piezoelectric actuator for fine rotation control. Together, these actuators enable control of the EC length over a range of about 90 m with a resolution of 0.9 nm, and control of the grating angle over a coarse-tuning range of +/-6.3deg and a fine-tuning range of +/-520 microrad with a resolution of 10 nrad. A mirror mounted on the platform with the grating assures always the same direction of the output laser beam.

Wysocki, Gerard↗

Using High-Resolution Forward Model Simulations of Ideal Atmospheric Tracers to Assess the Spatial Information Content of Inverse CO2 Flux Estimates

Attribution of observed atmospheric carbon concentrations to emissions on the country, state or city level is often inferred using "inversion" techniques. Such computations are often performed using advanced mathematical techniques, such as synthesis inversion or four-dimensional variational analysis, that invoke tracing observed atmospheric concentrations backwards through a transport model to a source region. It is, to date, not well understood how well such techniques can represent fine spatial (and temporal) structure in the inverted flux fields. This question is addressed using forward-model computations with idealized tracers emitted at the surface in a large number of grid boxes over selected regions and examining how distinctly these emitted tracers can be detected downstream. Initial results show that tracers emitted in half-degree grid boxes over a large region of the Eastern USA cannot be distinguished from each other, even at short distances over the Atlantic Ocean, when they are emitted in grid boxes separated by less than five degrees of latitude - especially when only total-column observations are available. A large number of forward model simulations, with varying meteorological conditions, are used to assess how distinctly three types observations (total column, upper tropospheric column, and surface mixing ratio) can separate emissions from different sources. Inferences inverse modeling and source attribution will be drawn.

Pawson, Steven↗

Histogrammatic Method for Determining Relative Abundance of Input Gas Pulse

To satisfy the Major Constituents Analysis (MCA) requirements for the Vehicle Cabin Atmosphere Monitor (VCAM), this software analyzes the relative abundance ratios for N2, O2, Ar, and CO2 as a function of time and constructs their best-estimate mean. A histogram is first built of all abundance ratios for each of the species vs time. The abundance peaks corresponding to the intended measurement and any obfuscating background are then separated via standard peak-finding techniques in histogram space. A voting scheme is then used to include/exclude this particular time sample in the final average based on its membership to the intended measurement or the background population. This results in a robust and reasonable estimate of the abundance of trace components such as CO2 and Ar even in the presence of obfuscating backgrounds internal to the VCAM device. VCAM can provide a means for monitoring the air within the enclosed environments, such as the ISS (International Space Station), Crew Exploration Vehicle (CEV), a Lunar Habitat, or another vehicle traveling to Mars. Its miniature pre-concentrator, gas chromatograph (GC), and mass spectrometer can provide unbiased detection of a large number of organic species as well as MCA analysis. VCAM s software can identify the concentration of trace chemicals and whether the chemicals are on a targeted list of hazardous compounds. This innovation s performance and reliability on orbit, along with the ground team s assessment of its raw data and analysis results, will validate its technology for future use and development.

Mandrake, Lukas↗

Waypoint Following Dynamics of a Quaternion Error Feedback Attitude Control System

Closed-loop attitude steering can be used to implement alternative attitude maneuvers by using a conventional attitude control system to track a non-standard attitude profile sampled as a series of sequential commands. The idea has been employed in practice to perform zero-propellant maneuvers on the International Space Station and minimum time maneuvers on NASA’s TRACE space telescope. A challenge for operational implementation of the idea is the finite capacity of a space vehicle’s command storage buffer. One approach to mitigate the problem is to downsample-and-hold the attitude commands so that the attitude control system to follows a set of waypoints. This paper explores the waypoint following dynamics of a quaternion error feedback control law for downsample-and-hold. It is shown that downsample-and-hold induces a ripple between downsamples that causes the satellite angular rate to significantly overshoot the desired limit. Analysis in the z-domain is carried out in order to understand the phenomenon. An interpolating Chebyshev-type filter is proposed that allows attitude commands to be encoded in terms of a small set of filter coefficients. Using the interpolating filter, commands can be issued at the ACS rate but with significantly reduced memory requirements. The attitude control system of NASA’s Lunar Reconnaissance Orbiter is used as an example to illustrate the behavior of a practical attitude control system.

Mark Karpenko↗

PCBoom Version 7 Technical Reference

PCBoom is a suite of sonic boom propagation programs that applies full three-dimensional ray tracing based on geometrical acoustics. It predicts sonic boom ground waveforms and footprints from supersonic flight vehicles performing arbitrary maneuvers using a variety of built-in or user-supplied nearfield vehicle source definitions. It also computes loudness metrics, ground signature locations, and sonic boom propagation times. The nomenclature "PC" in PCBoom denotes that the programs were historically targeted to run on a personal computer. PCBoom provides a valuable contribution toward sonic boom research as illustrated by the following examples: • PCBoom allows for quick “what if” type predictions for a multitude of sonic boom scenarios, including low boom design iteration work. • The detailed flight planning capabilities allow for flight conditions and waypoints to be provided to pilots to generate booms needed for research. • PCBoom allows for post-flight analysis of as-flown trajectories with measured weather data. • PCBoom has been used in sonic boom damage claim cases to determine claim veracity.

PCBoom↗

Demonstrating SolarPILOT's Python API Through Heliostat Optimal Aimpoint Strategy Use Case: Preprint

SolarPILOT is a software package that generates heliostat field layouts and characterizes the optical performance of concentrating solar power (CSP) tower systems. SolarPILOT was developed by the National Renewable Energy Laboratory (NREL) as a stand-alone desktop application but has also been incorporated into NREL's System Advisor Model (SAM) in a simplified format. Prior means for user interaction with SolarPILOT have included the application's graphical interface, the SAM routines with limited configurability, and through a built-in scripting language called "LK." This paper presents a new, full-featured Python-based application programmable interface (API) for SolarPILOT, which we hereafter refer to as CoPylot. CoPylot provides access to all SolarPILOT's capabilities to generate and characterize power tower CSP systems seamlessly through Python. Supported capabilities include (i) creating and destroying a model instances with message reporting tools; (ii) accessing and setting any SolarPILOT variable including custom land boundaries for field layout; (iii) programmatically managing receiver and heliostat objects with varied attributes for systems with multiple receiver or heliostat types; (iv) generating, assigning, and modifying heliostat field layouts including the ability to set individual heliostat locations, aimpoints, soiling rates, and reflectivity levels; (v) simulating heliostat field performance; (vi) returning detailed results describing performance of individual heliostats, the aggregate field, and receiver flux; and, (vii) exporting Python-based model instances to multiple file formats. CoPylot enables Python users to perform detailed tower CSP analysis utilizing either the Hermite expansion technique (analytical) or the SolTrace ray-tracing engine. In addition to CoPylot's functionality, Python users have access to the over 100,000 open-source libraries to develop, analyze, optimize, and visualize CSP tower research.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Self-Adjusting Metal–Organic Framework for Efficient Capture of Trace Xenon and Krypton

The capture of the xenon and krypton from nuclear reprocessing off-gas is essential to the treatment of radioactive waste. Although various porous materials have been employed to capture Xe and Kr, the development of high-performance adsorbents capable of trapping Xe/Kr at very low partial pressure as in the nuclear reprocessing off-gas conditions remains challenging. Herein, we report a self-adjusting metal-organic framework based on multiple weak binding interactions to capture trace Xe and Kr from the nuclear reprocessing off-gas. The self-adjusting behavior of ATC-Cu and its mechanism have been visualized by the in-situ single-crystal X-ray diffraction studies and theoretical calculations. The self-adjusting behavior endows ATC-Cu unprecedented uptake capacities of 2.65 and 0.52 mmol g -1 for Xe and Kr respectively at 0.1 bar and 298 K, as well as the record Xe capture capability from the nuclear reprocessing off-gas. Further, our work not only provides a benchmark Xe adsorbent but proposes a new route to construct smart materials for efficient separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adsorption processes in spacecraft environmental control and life support systems

The environmental control and life support system on a spacecraft maintains a safe and comfortable environment in which the crew can live and work by supplying oxygen and water and by removing carbon dioxide, water vapor, and trace contaminants from cabin air. Although open-loop systems have been used successfully in the past for short-duration missions, the economics of current and future long-duration missions in space will make nearly complete recycling of air and water imperative. A variety of operations will be necessary to achieve the goal of nearly complete recycling. These include separation and reduction of carbon dioxide, removal of trace gas-phase contaminants, recovery and purification of humidity condensate, purification and polishing of wastewater streams, and others. Several of these can be performed totally or in part by adsorption processes. These processes are good candidates to perform separations and purifications in space due to their gravity independence, high reliability, relative high energy efficiency, design flexibility, technological maturity, and regenerative nature. For these reasons, adsorption has historically played a key role in life support on U.S. and Russian piloted spacecraft. Among the life support applications that can be achieved through use of adsorption technology are removal of trace contaminants and carbon dioxide from cabin air and recovery of potable water from waste streams. In each of these cases adsorption technology has been selected for use onboard the International Space Station. The requirements, science, and hardware for these applications are discussed. Human space exploration may eventually lead to construction of planetary habitats. These habitats may provide additional opportunities for use of adsorption processes, such as control of greenhouse gas composition, and may have different resources available to them, such as gases present in the planetary atmosphere. Separation and purification processes based on adsorption can be expected to continue to fulfill environmental control and life support needs on future missions.

Review, Tutorial↗

A hierarchical approach for modeling X-ray beamlines: application to a coherent beamline

Herein, different approaches to simulate a modern X-ray beamline are considered. Several methodologies with increasing complexity are applied to discuss the relevant parameters that quantify the beamline performance. Parameters such as flux, dimensions and intensity distribution of the focused beam, and coherence properties are obtained from simple analytical calculations to sophisticated computer simulations using ray-tracing and wave optics techniques. A latest-generation X-ray nanofocusing beamline for coherent applications (ID16A at the ESRF) has been chosen to study in detail the issues related to highly demagnifying synchrotron sources and exploiting the beam coherence. The performance of the beamline is studied for two storage rings: the old ESRF-1 (emittance 4000 pm) and the new ESRF-EBS (emittance 150 pm). In addition to traditional results in terms of flux and beam sizes, an innovative study on the partial coherence properties based on the propagation of coherent modes is presented. The different algorithms and methodologies are implemented in the software suite OASYS . These are discussed with emphasis placed upon the their benefits and limitations of each.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reimagining Disassembly Interfaces With Visualization: Combining Instruction Tracing and Control Flow With DisViz

In applications where efficiency is critical, developers may examine their compiled binaries, seeking to understand how the compiler transformed their source code and what performance implications that transformation may have. This analysis is challenging due to the vast number of disassembled binary instructions and the many-to-many mappings between them and the source code. These problems are exacerbated as source code size increases, giving the compiler more freedom to map and disperse binary instructions across the disassembly space. Interfaces for disassembly typically display instructions as an unstructured listing or sacrifice the order of execution. Here, we design a new visual interface for disassembly code that combines execution order with control flow structure, enabling analysts to both trace through code and identify familiar aspects of the computation. Central to our approach is a novel layout of instructions grouped into basic blocks that displays a looping structure in an intuitive way. We add to this disassembly representation a unique block-based mini-map that leverages our layout and shows context across thousands of disassembly instructions. Finally, we embed our disassembly visualization in a web-based tool, DisViz, which adds dynamic linking with source code across the entire application. DizViz was developed in collaboration with program analysis experts following design study methodology and was validated through evaluation sessions with ten participants from four institutions. Participants successfully completed the evaluation tasks, hypothesized about compiler optimizations, and noted the utility of our new disassembly view. Our evaluation suggests that our new integrated view helps application developers in understanding and navigating disassembly code.

Computer science↗

Quantification of trace iodine using laser-induced breakdown spectroscopy for real-time monitoring of nuclear off-gas streams

This study evaluated the potential of laser-induced breakdown spectroscopy (LIBS) for real-time monitoring of trace gas-phase iodine, which is an element of high significance in nuclear applications due to its long radioactive half-life (as iodine-129), volatility, and biological impact. In anticipation of iodine evolving into off-gas systems in molten salt reactor and nuclear fuel recycling applications, this research aimed to assess LIBS performance in flowing argon and helium matrices; optimize measurement parameters using a multichannel spectrometer; and perform calibrations to assess predictive capabilities and limits of detection (LODs). Experimental results successfully measured gas-phase iodine in flowing argon and helium; however, trace iodine was not detected in air. Optimal delay times were determined to be 10 µs for argon and 1 µs for helium, which are consistent with the expected shorter plasma lifetime in helium relative to argon. An emission line survey was provided with the 206.16, 804.37, 902.24, and 905.83 nm peaks, which were identified as the strongest emission peaks. Calibration models were successfully built in both helium and argon, achieving LODs down to 3 ppm in helium and 5 ppm in argon. The iodine emission at 905.83 nm emerged as the most robust for calibration and was subsequently applied to a time series dataset in argon. The predictive trace confirmed the feasibility of employing LIBS for continuous, online quantification of trace iodine in flowing gas systems.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗