Towards a Portable Open-Source Tomography Toolbox: Containerizing Tomography Software with Docker
N/A
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
N/A
Explore the source record for details and available documents.
In this paper, we report on experiments exploring X-ray emission from an X-pinch driven by a small Marx-waterline generator supplying 50 kA with a risetime of 50 ns and a peak voltage of ~250 kV. Both standard crossed wire loads and hybrid loads utilizing conical metal electrodes with a single short wire in between them were studied, and in both cases reliable modes of operation were obtained for X-ray radiography. Soft (few keV) and Hard (>5 keV) X-ray emission characteristics were observed. With standard X-pinches, soft radiation emanated from a small hot spot about 3 μm in size, along with hard radiation from a ~200 μm region close to this hot spot. With hybrid X-pinches, the hot spot was <7 μm in size. Finally, there was a clear correlation between the soft and hard X-ray emission—pinches that produced intense soft X-ray emission from a small hot spot also produced the most intense, localized hard X-ray emission.
Explore the source record for details and available documents.
Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.
We report the first optical Thomson scattering measurements inside a high electron temperature (≳1 keV) and moderate electron density (mid 10 16 cm –3 ) plasma. This diagnostic has been built to provide critical plasma parameters, such as electron temperature and density, for Advanced Research Projects Agency-Energy-supported fusion-energy concepts. It uses an 8 J laser at 532 nm in 1.5 ns to measure the high frequency feature of the Thomson scattering profile at 17 locations along the probe axis. It is able to measure electron density from 5 × 10 17 cm –3 to several 10 19 cm –3 and electron temperatures from tens of eV to several keV. Here, in this paper, we describe the design, deployment, and analysis on the sheared flow stabilized Z-pinch machine at Zap Energy named FuZE. The probe beam is aimed at an axial distance of 20 cm from the central electrode and is timed within the temporal envelope of neutron emission. The high temperature and moderate density plasmas generated on FuZE lie in an unconventional regime for Thomson scattering as they are between tokamaks and laser-produced plasmas. We described the analysis considerations in this regime, show that the electron density was below 5 × 10 16 cm –3 at all times during these measurements, and present a sample shot where the inferred electron temperature varied from 167 ± 16 eV to 700 ± 85 eV over 1.6 cm.
Explore the source record for details and available documents.
For more than a decade Monte Carlo event generators with the current matrix element algorithms have been used for generating hard scattering events on CPU platforms, with excellent flexibility and good efficiency. While the HL-LHC is approaching and precision requirements are becoming more demanding, many studies have been made to solve the bottleneck in the current Monte Carlo event generator tool chains. The novel BlockGen family of fast matrix element algorithms shown in this report, is one of the new developments that are more suitable for GPU acceleration. We report the development experience of porting BlockGen using Kokkos. Moreover, we discuss the performance of the Kokkos version in comparison with the dedicated GPU version in CUDA.
In this article, we present the design and implementation of a regional ocular telehealth network for remote assessment and management of diabetic retinopathy (DR), including the design requirements, network topology, protocol design, system work flow, graphics user interfaces, and performance evaluation. The Telemedical Retinal Image Analysis and Diagnosis Network is a computer-aided, image analysis telehealth paradigm for the diagnosis of DR and other retinal diseases using fundus images acquired from primary care end users delivering care to underserved patient populations in the mid-South and southeastern United States.
Abstract Electronic health record (EHR) algorithms for defining patient cohorts are commonly shared as free-text descriptions that require human intervention both to interpret and implement. We developed the Phenotype Execution and Modeling Architecture (PhEMA, http://projectphema.org) to author and execute standardized computable phenotype algorithms. With PhEMA, we converted an algorithm for benign prostatic hyperplasia, developed for the electronic Medical Records and Genomics network (eMERGE), into a standards-based computable format. Eight sites (7 within eMERGE) received the computable algorithm, and 6 successfully executed it against local data warehouses and/or i2b2 instances. Blinded random chart review of cases selected by the computable algorithm shows PPV ≥90%, and 3 out of 5 sites had >90% overlap of selected cases when comparing the computable algorithm to their original eMERGE implementation. This case study demonstrates potential use of PhEMA computable representations to automate phenotyping across different EHR systems, but also highlights some ongoing challenges.
We generalize the nature of the so-called beam-dump “ceiling” beyond which the improvement on the sensitivity reach in the search for fast-decaying mediators dramatically slows down, and we point out its experimental implications that motivate tabletop-sized beam-dump experiments for the search. Light (bosonic) mediators are well-motivated new-physics particles, as they can appear in dark-sector portal scenarios and models to explain various laboratory-based anomalies. Due to their low mass and feebly interacting nature, beam-dump-type experiments, utilizing high-intensity particle beams, can play a crucial role in probing the parameter space of such visibly decaying mediators—in particular, the “prompt decay” region, where the mediators feature relatively large coupling and mass. We present a general and semianalytic proof that the ceiling effectively arises in the prompt-decay region of an experiment and show its insensitivity to data statistics, background estimates, and systematic uncertainties, considering a concrete example, the search for axion-like particles interacting with ordinary photons at three benchmark beam facilities: PIP-II at FNAL, and SPS and LHC-dump at CERN. We then identify optimal criteria to perform a cost-effective and short-term experiment to reach the ceiling, demonstrating that very short-baseline compact experiments enable access to the parameter space unreachable thus far.
A realistic and detailed description of neutrinos in binary neutron star (BNS) mergers is essential to build reliable models of such systems. To this end, we present bns_nurates, a novel open-source numerical library designed for the efficient on-the-fly computation of neutrino interactions, with particular focus on regimes relevant to BNS mergers. bns_nurates targets a higher level of accuracy and realism in the implementation of commonly employed reactions by accounting for relevant microphysics effects on the interactions, such as weak magnetism and mean field effects. It also includes the contributions of inelastic neutrino scattering off electrons and positrons and (inverse) nucleon decays. Finally, it offers a way to reconstruct the neutrino distribution function in the framework of moment-based transport schemes. As a first application, we compute both energy-dependent and energy-integrated neutrino emissivities and opacities for conditions extracted from a BNS merger simulation with m1 transport scheme. We find some qualitative differences in the results when considering the impact of the additional relevant reactions and of microphysics effects. For example, neutrino-electron/positron scattering reactions are important for the energy exchange of heavy-type neutrinos as they do not undergo semileptonic charged-current processes, when μ± are not accounted for. Moreover, weak magnetism and mean field effects can significantly modify the contribution of β processes for electron-type (anti)neutrinos, increasing at the same time the importance of (inverse) neutron decays. Here, the improved treatment for the reaction rates also modifies the conditions at which neutrinos decouple from matter in the system, potentially affecting their emission spectra.
Ultra-SAXS can enhance the capabilities of existing synchrotron SAXS/WAXS beamlines. A compact ultra-SAXS module has been developed, which extends the measurable q -range with 0.0015 ≤ q (nm −1 ) ≤ 0.2, allowing structural dimensions in the range 30 ≤ D (nm) ≤ 4000 to be probed in addition to the range covered by a high-end SAXS/WAXS instrument. By shifting the module components in and out on their respective motor stages, SAXS/WAXS measurements can be easily and rapidly interleaved with USAXS measurements. The use of vertical crystal rotation axes (horizontal diffraction) greatly simplifies the construction, at minimal cost to efficiency. In this paper, the design considerations, realization and synchrotron findings are presented. Measurements of silica spheres, an alumina membrane, and a porous carbon catalyst are provided as application examples.
NWChem is one of the most widely used computational chemistry application suites for chemical and biological systems. Despite its vast success, the computational efficiency of NWChem is still low. This is especially true in higher accuracy methods such as the CCSD(T) coupled cluster method, where it currently achieves a mere 50% computational efficiency when run at large scales. In this paper, we demonstrate the most computationally efficient scaling of NWChem CCSD(T) to date, and use it to solve large water clusters. We use our recently proposed process-based asynchronous progress framework for MPI RMA, called Casper, to scale the computation on water clusters at near-100% computational efficiency on up to 12288 cores.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.