Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Earth radiation budget - Results of outgoing longwave radiation from Nimbus-7, NOAA-9, and ERBS satellites

Outgoing longwave radiation (OLR) data from Nimbus-7 ERB wide field-of-view instruments are compared with results from the ERBE instruments aboard the NOAA-9 and NOAA-10 satellites. Over most regions of the globe, the agreement between the two sets of OLR results is generally to within 8 W/sq m. There are larger differences at higher latitudes and regions concentrated over land and desert. Results of daytime and nighttime differences suggest that the shortwave channels may be at fault due to their different design for Nimbus-7 and NOAA-9. Some of the differences may also be related to different viewing geometry of the two satellites.

Bess, T. D.↗

An information theory approach for evaluating earth radiation budget (ERB) measurements - Nonuniform sampling of reflected shortwave radiation

An information theory approach to examine the temporal nonuniform sampling characteristics of shortwave (SW) flux for earth radiation budget (ERB) measurements is suggested. The information gain is computed by computing the information content before and after the measurements. A stochastic diurnal model for the SW flux is developed, and measurements for different orbital parameters are examined. The methodology is applied to specific NASA Polar platform and Tropical Rainfall Measuring Mission (TRMM) orbital parameters. The information theory approach, coupled with the developed SW diurnal model, is found to be promising for measurements involving nonuniform orbital sampling characteristics.

Barkstrom, Bruce R.↗

Uncertainties in radiation effect predictions for the natural radiation environments of space

Future manned missions beyond low earth orbit require accurate predictions of the risk to astronauts and to critical systems from exposure to ionizing radiation. For low-level exposures, the hazards are dominated by rare single-event phenomena where individual cosmic-ray particles or spallation reactions result in potentially catastrophic changes in critical components. Examples might be a biological lesion leading to cancer in an astronaut or a memory upset leading to an undesired rocket firing. The risks of such events appears to depend on the amount of energy deposited within critical sensitive volumes of biological cells and microelectronic components. The critical environmental information needed to estimate the risks posed by the natural space environments, including solar flares, is the number of times more than a threshold amount of energy for an event will be deposited in the critical microvolumes. These predictions are complicated by uncertainties in the natural environments, particularly the composition of flares, and by the effects of shielding. Microdosimetric data for large numbers of orbits are needed to improve the environmental models and to test the transport codes used to predict event rates.

Mcnulty, P. J.↗

Measurements of the Downward Longwave Radiation Spectrum over the Antarctic Plateau and Comparisons with a Line-by-Line Radiative Transfer Model for Clear Skies

A 1-year field program was conducted at South Pole Station in 1992 to measure the downward infrared radiance spectrum at a resolution of 1/ cm over the spectral range 550-1667 cm-'. The atmosphere over the Antarctic Plateau is the coldest and driest on Earth, where in winter, surface temperatures average about -60 C, the total column water vapor is as low as 300 pm of precipitable water, and the clear-sky downward longwave flux is usually less than 80 W/sq m. Three clear-sky test cases are selected, one each for summer, winter, and spring, for which high- quality radiance data are available.as well as ancillary data to construct model atmospheres from radiosondes, ozonesondes, and other measurements. The model atmospheres are used in conjunction with the line-by-line radiative transfer model (LBLRTM) to compare model calculations with the spectral radiance measurements. The high-resolution calculations of LBLRTM (approx. = 0.001/ cm) are matched to the lower-resolution measurements (1/ cm) by adjusting their spectral resolution and by applying a correction for the finite field of view of the interferometer. In summer the uncertainties in temperature and water vapor profiles dominate the radiance error in the LBLRTM calculations. In winter the uncertainty in viewing zenith angle becomes important as well as the choice of atmospheric levels in the strong near-surface temperature inversion. The spectral radiance calculated for each of the three test cases generally agrees with that measured, to within twice the total estimated radiance error, thus validating LBLRTM to this level of accuracy for Antarctic conditions. However, the discrepancy exceeds twice the estimated error in the gaps between spectral lines in the region 1250-1500/ cm, where emission is dominated by the foreign-broadened water vapor continuum.

Walden, Von P.↗

Radiation Engineering Analysis of Shielding Materials to Assess Their Ability to Protect Astronauts in Deep Space From Energetic Particle Radiation

An analysis is performed on four typical materials (aluminum, liquid hydrogen, polyethylene, and water) to assess their impact on the length of time an astronaut can stay in deep space and not exceed a design basis radiation exposure of 150 mSv. A large number of heavy lift launches of pure shielding mass are needed to enable long duration, deep space missions to keep astronauts at or below the exposure value with shielding provided by the vehicle. Therefore, vehicle mass using the assumptions in the paper cannot be the sole shielding mechanism for long duration, deep space missions. As an example, to enable the Mars Design Reference Mission 5.0 with a 400 day transit to and from Mars, not including the 500 day stay on the surface, a minimum of 24 heavy lift launches of polyethylene at 89,375 lbm (40.54 tonnes) each are needed for the 1977 galactic cosmic ray environment. With the assumptions used in this paper, a single heavy lift launch of water or polyethylene can protect astronauts for a 130 day mission before exceeding the exposure value. Liquid hydrogen can only protect the astronauts for 160 days. Even a single launch of pure shielding material cannot protect an astronaut in deep space for more than 180 days using the assumptions adopted in the analysis. It is shown that liquid hydrogen is not the best shielding material for the same mass as polyethylene for missions that last longer than 225 days.

Singleterry, R. C.↗

Guideline for ground radiation testing of microprocessors in the space radiation environment

The goal of this work is to develop a guideline that is applicable to processors that are potentially useful in space. Thus, the guideline does not consider very high performance processors that are intended for server or high-performance applications where very large amounts of power are tolerated to gain performance because it would be impractical to use such high-power devices in typical space applications. This guide is intended to support insertion of these microprocessors into spaceflight applications and to recommend ground test protocols. The first guideline principle that should be followed is a serious concurrent engineering approach for down selecting space-qualified microprocessors. This requires that the design engineer seek the support of a radiation effects expert who understands total ionizing dose (TID) and single-event effects (SEEs) issues for microprocessors as applied to the system in question.

Irom, Farokh↗

Standard and goal-oriented adaptive mesh refinement applied to radiation transport on 2D unstructured triangular meshes

Standard and goal-oriented adaptive mesh refinement (AMR) techniques are presented for the linear Boltzmann transport equation. A posteriori error estimates are employed to drive the AMR process and are based on angular-moment information rather than on directional information, leading to direction-independent adapted meshes. An error estimate based on a two-mesh approach and a jump-based error indicator are compared for various test problems. In addition to the standard AMR approach, where the global error in the solution is diminished, a goal-oriented AMR procedure is devised and aims at reducing the error in user-specified quantities of interest. The quantities of interest are functionals of the solution and may include, for instance, point-wise flux values or average reaction rates in a subdomain. A high-order (up to order 4) Discontinuous Galerkin technique with standard upwinding is employed for the spatial discretization; the discrete ordinates method is used to treat the angular variable.

97 MATHEMATICS AND COMPUTING↗

Ultrafast, high resolution, phase contrast imaging of impact response with synchrotron radiation

Understanding the dynamic response of materials at extreme conditions requires diagnostics that can provide real-time, in situ, spatially resolved measurements on the nanosecond timescale. The development of methods such as phase contrast imaging (PCI) typically used at synchrotron sources offer unique opportunities to examine dynamic material response. In this work, we report ultrafast, high-resolution, dynamic PCI measurements of shock compressed materials with 3 {mu}m spatial resolution using a single 60 ps synchrotron X-ray bunch. These results firmly establish the use of PCI to examine dynamic phenomena at ns to {mu}s timescales.

36 MATERIALS SCIENCE↗

The Radiation Chemistry of CMPO: Part 2. Alpha Radiolysis

Here, Octylphenyl-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) dissolved in dodecane was subjected to α-irradiation using a He-ion beam, 244 Cm isotopic α-rays, and He and Li ions created by the n,α reaction of 10 B in a nuclear reactor. Post-irradiation samples were analyzed for the radiolytically-induced decrease in CMPO concentration, the appearance of degradation products, and their Am solvent extraction distribution ratios. The –G CMPO -value for the radiolytic degradation of CMPO was found to be very low compared to values previously reported for γ-irradiation. Additionally, isotopic irradiation to absorbed α-doses as high as 600 kGy in aerated solution had no effect on Am solvent extraction or stripping. The main CMPO radiolysis products identified in He-ion beam irradiated samples by ESI-MS include amides, an acidic amide, and amines produced by bond rupture on either side of the CMPO carbonyl group. Deaerated samples irradiated using the reactor in the absence of an aqueous phase, or with a dilute nitric acid aqueous phase showed small but measurable decreases in CMPO concentration with increasing absorbed doses. Higher concentrations of nitric acid resulted in lower decomposition rates for the CMPO. The radio-protection by dissolved oxygen and nitric acid previously found for γ-irradiated CMPO also occurs for α-irradiation. This suggests that similar free-radical mechanisms operate in the high-LET system, but with lower degradation yields due to the lower overall radical concentrations produced.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Current advances in synchrotron radiation instrumentation for MX experiments

Following pioneering work 40 years ago, synchrotron beamlines dedicated to macromolecular crystallography (MX) have improved in almost every aspect as instrumentation has evolved. Beam sizes and crystal dimensions are now on the single micron scale while data can be collected from proteins with molecular weights over 10 MDa and from crystals with unit cell dimensions over 1000 Å. Furthermore it is possible to collect a complete data set in seconds, and obtain the resulting structure in minutes. The impact of MX synchrotron beamlines and their evolution is reflected in their scientific output, and MX is now the method of choice for a variety of aims from ligand binding to structure determination of membrane proteins, viruses and ribosomes, resulting in a much deeper understanding of the machinery of life. A main driving force of beamline evolution have been advances in almost every aspect of the instrumentation comprising a synchrotron beamline. In this review we aim to provide an overview of the current status of instrumentation at modern MX experiments. The most critical optical components are discussed, as are aspects of endstation design, sample delivery, visualisation and positioning, the sample environment, beam shaping, detectors and data acquisition and processing.

59 BASIC BIOLOGICAL SCIENCES↗